Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹28.6 L+₹87,078.75 (3.14%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹32.4 L+₹4.7 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹39.8 L+₹12.0 L (43.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹41.4 L+₹13.7 L (49.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹49.0 L
EMD Value
₹97,960
Closing Date
13 Oct 2021, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/REPLACEMENT OF UNSERVICEABLE STREET LIGHTS, PERIMETER LIGHTING, POST TOP LAMPS, GARDEN LIGHTS AND OTHER E/M REPAIRS UNDER AGE E/M NO-1 AT GE (I) R AND D KANCHANBAGH, HYDERABAD
2021_MES_475422_1
GE I KBAGH TOKEN 47 OF 2021 2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹97,960
Yes
12 Nov 2021
15 Sept 2021
15 Oct 2021
15 Sept 2021
13 Oct 2021
29 Sept 2021
16 Sept 2021 - 23 Sept 2021
Amount
Repair / maintenance of internal/ Building light fittings/ street lights/ security lights of any type like tube lights / wall bracket light fittings / ceiling lights / mirror lights/ high& Medium bay lights in its position, testing all the component's / parts, wiring etc, identifying and replacing the defective components like, LED tube, driver, fixtures, holders, bulbs etc all as directed. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like, capacitor, lamp holder, connector, connection wire, LED tube, Bulbs etc, replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective lights fittings and will submit the completion report as per complaints received on the same day before 1730hrs to the JE E/M.
(iv) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for different areas by engaging seperate team of electricians / technicians for DRDO Qtrs area DMRL area & DLRL area in order to ensure prompt & timely rectification of defects. (v) Contractor shall arrange requisite and cost sufficient number of transport and vehicle mounted hydraulic ladder at his own cost wherever required. (vi) The contractor shall maintain proper record of repair / maintenance in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maintenance record register to Engineer-in-charge for inspection on every Monday or as and when asked for. (vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and department shall not be responsible for any kind of mishap / accident / injury to workmen.
S&F in repair GI pipe bracket, made out of 40 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls as directed.
All as per item No. 2 above but made out of 25mm bore pipe.
Supply only 2 core, 4 sqmm LT 1100 volts grade, PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Supply only 2 core, 6 sqmm LT 1100 volts grade, PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Supply only 2 core, 10sqmm LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt in service connections etc all as directed.
Cutting/ trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights LT panel board/ LT over head lines in such a way that the clearance between LT panel board/ LT over head lines Street light pole and tree branches should not be less than 3 mtrs around the Pole/LT over head line complete all as directed. Note: 1. Quoted rate is deemed to include necessary hydraulic ladder arrangement and tree cutting machine and tools required at site. 2. One span shall be 35RM towards LT over head lines.
S&F in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: THREE phase load of 5-8KW, Contactor Rating 20 Amps per phase, MCB FP 63Amps. Make:- CAT Part no Healer Swadeep-02EC-5KW3P or equivalent in Nature Switch -Kakatiya Energy systems/Bajaj Contactors:-BCH/L&T/Schenider MCBs:- (input-output)
S&F in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: THREE phase load of 8-12KW, Contactor Rating 32Amps per phase, MCB FP 63Amps. Make:- CAT Part no Healer Swadeep-02EC-8KW3P or equivalent in Nature Switch -Kakatiya Energy systems/Bajaj Contactors:-BCH/L&T/Schenider MCBs:- (input-output)
S&F in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: Single phase load of 5-8 KW, Contactor Rating 40Amps per phase, MCB DP 40Amps. Make:- CAT Part no Healer Swadeep-02EC-3KW1P or equivalent in Nature Switch -Kakatiya Energy systems/Bajaj Contactors:-BCH/L&T/Schenider MCBs:- (input-output)
S&F in replacement of automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take: single phase load of 3-5KW, Contactor Rating 25Amps per phase, MCB DP 32Amps. Make:- CAT Part no Healer Swadeep-02EC-5KW1P or equivalent in Nature Switch -Kakatiya Energy systems/Bajaj Contactors:-BCH/L&T/Schenider MCBs:- (input-output)
Material & labour for Unbinding ACSR conductor and insulators from the poles and restretching/restringing & fixing the same ACSR conductor of any size on same poles and binding the same with & including the new 2mm dia aluminium binding wire and making/tightening of jumpers at appropriate place to ACSR conductor complete all as specified and directed by the Engineer in Charge. Note :- Four conductors between poles shall be considered as one length. Distance between pole to pole shall be considered as length of wires for the purpose of payment.
S&F in repairs SMC junction boxes (weather proof) IP 66, on street light poles made out of thermoplastic of size not less than 295mm x 195 mm x 100 mm size with connector for connecting incomming and outgoing of cable including provision of 01 No of MCB SP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flat for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as directed. Make:- Sintex/Hensel or as approved by the GE
Supply only electric driver for LED type fitting of following :-
50 Watt Driver
75 Watt Driver
100 Watt Driver
150 Watt Driver
Supply only LED street light IP 65, 230 Volt with all connected acessories required as directed by Engr-in-charge
Supply only LED flood light with IP66 protection with all necessary accessories required for fitting as directed by Engr-in-charge.
Supply, Laying, in replacement including Testing and Commissioning LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of following size complete all as specified and directed.
10Sqmm, 2Core
16Sqmm, 4Core
25Sqmm, 4 Core
Excavation in trenches, trenches not exc 1.5 M wide and not exc. 1.5 M in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in soft/loose. all as specified and directed by Engineer-in-charge.
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in any type of sand.
Removal of excavated material to distance 50 m and deposing where directed at a level not exceeding 1.5 m above the starting point.
Supply and filling dry clean sand in trenches for cushioning of underground cable including punning down all as directed.
M&L for laying of common burnt bricks, sub class 'B', old size 230 x 115 x 75 mm in trenches for cable protection complete all as directed.
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed
M&L for writing the pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background and white synthetic enamel painted letters. Note:- The numbers and words shall be all as directed by the Engineer-in-charge.
S&F retro reflective tape strips of red,white and yellow of 2 inch width fixed to Street light Poles as directed. Note:Three strip (One strip of red, white & Yelow) round the pole will be measured as one job.. Make: 3M/ DURASTRIP/ EURO
S&F cable jointing kit upto 50Sqmm for straight through joint (epoxy) for 1.1 KV grade XLPE, PVC insulated and sheathed aluminium conductor under ground cable including thimbles, nuts & bolts, washers etc and testing after jointing complete all as directed. Make: M-seal/Raychem/Transeal/Denson
S&F in replacmenet MCCB with rating of 125 Amps,415Volts 3 pole with 16kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) with inbuilt Display for Current Metering with accuracy of class 1. MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed. Make HAVELLS/STANDARD/SCHIENDER/LEGRAND
M&L for steel tubular swaged pole in replacement , type 410, SP-31 (9.0 meter long) complete with CI base plate and errection of pole including excavation and earth work and PCC (1:3:6) type D2 for foundation base and for foundation and coping with PCC (1:2:4) type B1 and painting with two coats of aluminium painting over a coat of red oxide primer & white wash for PCC coping including taking down old pole complete all as directed. Make: National tubing co.,/India Tubes co.,/ Bharat Poles. Note:- Crane charges for erection shall be deemed to be included in quoted rate.
M&L for cleaning the poles of 9/11 mtrs long of any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer including white wash to the coping and complete all as directed. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPER LAC)/ BERGER (LUXOL)
S&F in repairs of ballast copper wounded type of capacity 70W suitable for HPSV light fitting complete all as directed.
All as per item No.30 here in before but 150 Watts complete all as directed.
All as per item No.30 here in before but 250 Watts complete all as directed.
All as per item No.30 here in before but 400 Watts complete all as directed.
S&F in repairs Lamp tubular suitable for HPSV 150W fitting
S&F in repairs Lamp tubular suitable for HPSV 250W fitting
S&F in repairs Lamp tubular suitable for HPSV 400W fitting
S&F in repairs MH Lamp suitable for 150 Watt
S&F in repairs ignitor for HPSV/HID fittings 70/150/250/400 W
S&F in repairs lamp holder suitable for HPSV/MV/Halogen lamp upto 125W screw/Pin type complete all as directed.
S&F in repairs lamp holder suitable for HPSV/MV/Halogen lamp upto 150/250/400 complete all as directed.
UNITY ENGINEERING TRADERS
S.S.ENGINEERING CORPORATION
Bismi Engineering
M/s Kasturi Pedda Subbaiah Enterprises/M/s K.P.S Enterprises
M/S SRIDEVI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .