Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹50.0 L+₹4.5 L (9.82%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹56.2 L+₹10.6 L (23.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹59.4 L+₹13.9 L (30.5%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L4 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Chinmaya Enteprises L3 | Paragon Electrotechnics L2 | SONA LAKSHMI ASSOCIATE L1 | M/S. ELECTROPOWER TECHNOLOGIES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area size 16 Sqmm 4 core all as including testing after laid and jointed complete all as specified and directed.
Note:- Excavation and earth work, cable protection shall be measured and paid separetely. | 150 | RM | 215 ₹32,250 | 205 ₹30,750 | 180 ₹27,000 Lowest | 280 ₹42,000 |
| 2.00 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area size 10 Sqmm 4 core complete all as specified and directed. | 100 | RM | 200 ₹20,000 | 195 ₹19,500 | 140 ₹14,000 Lowest | 225 ₹22,500 |
| 3.00 | Excavation in trenches in any type of soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed. | 54 | Cum | 275 ₹14,850 | 250 ₹13,500 | 200 ₹10,800 Lowest | 350 ₹18,900 |
| 4.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. | 48.16 | Cum | 55 ₹2,648.8 | 50 ₹2,408 | 40 ₹1,926.4 Lowest | 120 ₹5,779.2 |
| 5.00 | Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed. | 5.84 | RM | 55 ₹321.2 | 50 ₹292 | 40 ₹233.6 Lowest | 100 ₹584 |
| 6.00 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50 mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. | 237.5 | RM | 70 ₹16,625 | 60 ₹14,250 | 50 ₹11,875 Lowest | 60 ₹14,250 |
| 7.00 | Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 240 Sqmm.
Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately. | 2 | Each | 3,100 ₹6,200 | 3,000 ₹6,000 Lowest | 3,000 ₹6,000 Lowest | 5,800 ₹11,600 |
| 8.00 | Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm all complete as specified and directed.
Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately. | 2 | Each | 2,700 ₹5,400 | 2,700 ₹5,400 | 2,500 ₹5,000 Lowest | 5,200 ₹10,400 |
| 9.00 | Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable size 10 Sqmm to 50 Sqmm all complete as specified and directed.
Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately. | 2 | Each | 2,500 ₹5,000 | 2,500 ₹5,000 | 2,000 ₹4,000 Lowest | 5,000 ₹10,000 |
| 10.00 | Supply and fix thermoplastic cable entry junction boxes of size 250 x 220 x 135 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 6-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. | 30 | Each | 1,800 ₹54,000 | 1,500 ₹45,000 | 900 ₹27,000 Lowest | 1,200 ₹36,000 |
Tender Value
₹46.4 L
EMD Value
₹92,740
Closing Date
27 Oct 2025, 6:00 pmClosed
Garrison Engineer
Military Engineer Services, Garrison Engineer, Cantt Area, Kamptee 441001
SPL REP/ REPLACEMENT OF OLD U/S ELECTRIC POLE, LT PANEL, APFC PANEL AND CONNECTED ITEMS AT SF MD ACCN AREA, R LINE AREA, T LINE AREA AT MIL STN KAMPTEE AND PROVN OF SOLAR STREET LIGHTS WITH POLE AND CONNECTED ACC IN MIL STN KAMPTEE UNDER GE KAMPTEE
2025_MES_733782_1
8821/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
All as per NIT
8 documents required · 8 mandatory
₹500
GE Kamptee
₹92,740
Yes
8 Dec 2025
6 Oct 2025
29 Oct 2025
6 Oct 2025
27 Oct 2025
20 Oct 2025
Amount
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area size 16 Sqmm 4 core all as including testing after laid and jointed complete all as specified and directed. Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area size 10 Sqmm 4 core complete all as specified and directed.
Excavation in trenches in any type of soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50 mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 240 Sqmm. Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm all complete as specified and directed. Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable size 10 Sqmm to 50 Sqmm all complete as specified and directed. Note :- Any Excavation and earth work, Returning and filling, Removing involved shall be measured and paid separately.
Supply and fix thermoplastic cable entry junction boxes of size 250 x 220 x 135 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 6-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed.
Supply and fix bracket for street light fittings made out of 32 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size all as specified and as directed.
Supply, erecting & fixing in replacement of steel tubular swaged pole complete with base plate, pole cap, nut bolt washer etc type 410 SP-31 (9.00 meters long) swaged poles conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint through out internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and Numbering of poles as directed including excavation /earth work, PCC 1:4:8 type D-2 using 40mm aggregate for pole foundations of size 600x600x1500mm height upto ground level and using PCC 1:2:4 B-1 for coping with size 450x450x300mm including necessary formwork complete with including taking down old unserviceable pole all as specified and as directed.
Materials and labour for Earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including GI wire 4.0 mm as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 32 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (a) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
S & F 1100 Volts grade Copper conductor, PVC insulated, round sheathed (flexible), industrial cable, 1.5 sqmm 3 core for connection from street light fitting to OH line or junction box, fixing accessories and complete all as specified and directed.
Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar of size 30 cm x 30 x 30 cm in ground with and including necessary foam work and making on board MES 1100 Volt LT Cable with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed.
PCC 1:2:4 (B1) with 20 mm aggregate in lintels upto 1.5m clear span, for coping of damged foundation of existing pole or filling in road cutting or hard standing, cills, steps, seismicand other similar bands, plinth courses, string courses, lacing courses, parapets andrailings upto 60 cm in height, copings, complete all as specified and directed.
M&L rendering 15 mm thick plaster on fair faces of brickwork or concrete sur faces or making good surface as per existing in CM 1:4 all as finishing the surface complete all as specified and directed.
Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired, outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate, fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type, all as specified and as directed. CONTD.../
CONTD TO ITEM NO. 18.00 Note : (iii) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (iv) SLD diagram for LT Panel shall be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (v) Rate for the same deemed to include in the quoted rates. Location : T Line MAP Main Panel at New Sub Stn comprising of the following :- (a) Busbar chamber for 3 phase & nuetral of capacity 1500 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos (c) One set of pilot lamp. (d) Incoming ACB 1000 Amps 4 Pole, 415 volts with Microprocessor release setting type, 50 KA - 01 Nos . (e) Outgoing MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -03 Nos. (f) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -03 Nos. (g) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (h) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : T Line Pump House Outside Panel (a) Busbar chamber for 3 phase & nuetral of capacity 1250 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos (c) One set of pilot lamp. (d) Incoming ACB 800 Amps 4 Pole, 415 volts with Microprocessor release setting type, 50 KA - 01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 250 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (f) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (g) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -04 Nos. (h) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -04 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : JN Road Main Panel (a) Busbar chamber for 3 phase & nuetral of capacity 1250 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming ACB 800 Amps 4 Pole, 415 volts with Microprocessor release setting type, 50 KA - 01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu = 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (f) Outgoing MCCB, 4 pole having current ratings 125 Amps, AC 415 Volts, with Icu = 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (g) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu = 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (h) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu = 25 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -06 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : Children Park JN Road & near Shopping complex gate (a) Busbar chamber for 3 phase & nuetral of capacity 1000 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming MCCB 630 Amps 4 Pole, 415 volts, with Icu= 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (f) Outgoing MCCB, 4 pole having current ratings 125 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (g) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (h) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -04 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : Duty / Depot Coy GRC Back side. (a) Busbar chamber for 3 phase & neutral of capacity 1000 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming MCCB 630 Amps 4 Pole, 415 volts, with Icu= 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu = 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (f) Outgoing MCCB, 4 pole having current ratings 125 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty - 01 Nos. (g) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (h) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -06 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : GRC JCOs Mess (a) Busbar chamber for 3 phase & nuetral of capacity 1000 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos (c) One set of pilot lamp. (d) Incoming MCCB 630 Amps 4 Pole, 415 volts with Icu = 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Onload Changeover switch 630 Amps, 4 Pole, AC 415 Volts - Qty -01 Nos. (f) Outgoing MCCB, 4 pole having current ratings 250 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (g) Outgoing MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (h) Outgoing MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. CONTD../
CONTD ITEM NO. 24.00 (j) Outgoing MCCB, 4 pole having current ratings 125 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (k) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (l) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : JN Road backside Bldg No. 5 (a) Busbar chamber for 3 phase & nuetral of capacity 800 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming MCCB 400 Amps 4 Pole, 415 volts with Icu= 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (f) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -06 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : Army Public School Sub Stn Main Panel (a) Busbar chamber for 3 phase & nuetral of capacity 800 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming MCCB 400 Amps 4 Pole, 415 volts with Icu= 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -02 Nos. (f) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu= 25 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -03 Nos.
All as per item No. 18 here-in-before but comprising of the following :- Location : Near RO Plant backside of Central Cook House GRC (a) Busbar chamber for 3 phase & nuetral of capacity 800 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Multifunctioning meter to measure Voltage, Ampere, KWH, PF - 01 Nos. (c) One set of pilot lamp. (d) Incoming MCCB 400 Amps 4 Pole, 415 volts with Icu= 50 KA , Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos. (e) Outgoing MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 36 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -03 Nos. (f) Outgoing MCCB, 4 pole having current ratings 63 Amps, AC 415 Volts, with Icu = 25 KA, Ics = 100% of Icu, with adjustable type overload setting (Min 70% to 100%) - Qty -05 Nos.
M&L for Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I). Notes for srl Item No. 3.06 & 3.07. (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. CONTD.../
CONTD ITEM NO. 29.00 (c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account. (d) Earthing work will be carried out in presence of MES representative.
CONTD ITEM NO 31.00 (a) APFC panel 240 KVAR panel with Incommer MCCB 400 Amps, 50. KA, 4 pole, contactor suitable for capacitor rating &MPP-H capacitor banks. The APFC controller should have Auto on/off capacitor banks in the step of (5x1+10x1+25x1+50x4) KVAR MPP-H capacitor banks rating and accessories are as under :- i) Power capacitor for two branch 01 No of capacity 5 KVAr each ii) Power capacitor for two branch 01 No of capacity 10 KVAr each iii) Power capacitor for two branch 01 No of capacity 25 KVAr each iv) Power capacitor for three branch 4 Nos of capacity 50 KVAr each v) Switching device for 2 KVAr capacitor Branch = MO C5 (1 NO aux contacts for each branch) vi) Switching device for 3 KVAr capacitor Branch = MO C 20 (1 NO aux contacts for each branch) vii) Switching device for 5 KVAr capacitor Branch = MO C15 (1 NO aux contacts for each branch) viii) Switching device for 10 KVAr capacitor Branch = MO C12.5( 1 NO aux contacts for each branch) ix) Switching device for 20 KVAr capacitor Branch = MO C12.5( 1 NO aux contacts for each branch) x) Accessories for switching device = 1 Normally closed + normally opened side add-on lock for each Branch xi) protection for each branch tripple pole MCB of rating not less than 2 times the charging current of indiusal stage. xii) APFC microprocessor Controller = 5 Star APFC Relay
M&L for Spray painting to existing LT Panel of any capacity / size / type including mounting angle with two coats of approved colour synthetic enamel paint complete including dusting, cleaning of existing dust before applying synthetic enamel paint and writing feeder name with approved colour synthetic enamel paint complete all as specified and directed.
Supply and fixing Solar based LED street light fitting 40 watt including 6 Mtr Steel Octagonal welded pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor etc complete all as specified and as directed and brief specifications of light fitting as under :- (a) 6 meter long Octagonal Pole complete including suitable bracket for hanging of Solar light, base plate, foundation nuts bolts including RCC foundation as per manufacturer foundation drawing to withstand the said pole and fixing arrangements for installation of street light all as per IS 4759/ IS 2629, BSEN 10025 and ISO 14001. (b) Type- AII IN ONE solar street light 40 watt (c) Colour Temp. (CCT) -5700 to 6500k (d) System Power(W) - 40 W (e) System Lumens (lm) - 4800 lm (f) Colour of Fixture - White (g) Autonomy - 2 days / 24 Hr (h) Battery- 12.8V 24 to 36AH Lithium Ferro Phosphate (Li-FePo4) Rechargeable, Integrated inside the fitting (j) Watt peak (Wp)- 65 to 100 WP (k) IP65 (l) PIR motion sensor for Auto on /off and Dimming feature (m) Indication - Green Stable-Battery Charging , Green Blinking- Battery Full Charge, Red Stable- Battery low voltage. Note:- The quoted rate shall deemed to be included for the following :- (a) Excavation, earth work and PCC work for embedding pole (b) Pole upto 1.5m top of coping shall be marked with 3M tape of black and yellow strips alternate 30 cm each. (c) Poles shall be numbered.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 25,450.00]
Paragon Electrotechnics (BID ID -3469352)
Chinmaya Enteprises (BID ID -3463702)
M/S. ELECTROPOWER TECHNOLOGIES (BID ID -3463044)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tenderdocument8821.pdf
Tender Documents • 0.77 MB
BOQ_821598.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .