Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.6 LAccepted-AOC | L-1 | Accepted-AOC ok | |
| 2 | L-2₹28.0 L+₹26,845.50 (0.97%)Rejected-AOC | L-2 | Rejected-AOC ok | |
| 3 | L-3₹29.6 L+₹1.8 L (6.61%)Rejected-AOC R O VILL NARAIN P O SHARONTHA TEHSIL TIKKAR DISTT SHIMLA HP | SHIMLA | HIMACHAL PRADESH | 170009 | L-3 | Rejected-AOC ok | |
| 4 | L4₹34.7 L+₹7.0 L (25.1%)Rejected-AOC N A | NA | NA | 121004 | L4 | Rejected-AOC ok | |
| 5 | Rejected-Technical | - | Rejected-Technical Machinery not Sufficient |
Tender Value
₹25.2 L
EMD Value
₹45,400
Closing Date
5 Dec 2019, 6:00 pmClosed
Executive Engineer
Division HPPWD Bharwain
Construction of link road Kharoh to Bhatehar km 000 to 3500 SH Construction of 6 meter span RCC slab culverts at RD 2810 and 900mm dia Hume pipe culvert at RD 2880 under SCCP
2019_PWD_32961_1
LR Kharoh to Bhatehar Under Bharwain Divn
Open Tender
Civil Works
Item Rate
180 days
Bharwain
Tender documents
4 documents required · 4 mandatory
₹1,500
EE Bharwain
₹45,400
25 Jun 2020
28 Nov 2019
6 Dec 2019
28 Nov 2019
5 Dec 2019
28 Nov 2019
Amount
Earth work in excavation for all type of road structure such as retaining walls, breast walls, culverts and drains etcetera in all type of classification of soil comprising of ordinary soil, ordinary rock, hard rock, chiselling/wedging out rocks( where blasting is prohibited ) as per drawings and M.O.R.D. technical specification clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all leads, lifts including dressing of sides and bottom and back filling in trenches with excavated suitable approved material to the original surface in layers not exceeding 150mm ( one hundred fifty millimeter) compacted thickness including shoring and strutting and pumping and bailing out water ( surface and sub soil water ) upto any depth and any quantum of water including cleaning of slush which may arise out during dewatering as per the direction of the Engineer-in-charge including carriage of material within all leads, lifts and other incidentals. The rates are inclusive octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying mechanically mixed and vibrated concrete for plain/reinforced concrete in open foundation for all type of structure complete of plain cement concrete grade M-10 (M-Ten) on ground or under water and curing complete including pumping or bailing out water, dewatering removal of slush as required at site which may arise at the time of laying under water complete for all heights/ depths including the cost of form work as per drawings and M.O.R.D. technical specification Clause 802, 803, 1202 and 1203 as per the direction of the Engineer-in-charge , including carriage of materials within all leads, lifts and other incidentals. The rates are inclusive octroi, royalty, Malkana, toll tax , goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying mechanically mixed and vibrated concrete for plain/reinforced concrete in sub structure for all type of structure complete of plain cement concrete grade M-15 (M-fifteen) design mix cement contents not less than 275 kg per cubic meter on ground or under water and curing complete including pumping or bailing out water, dewatering removal of slush as required at site which may arise at the time of laying under water complete for all heights/ depths including the cost of form work as per drawings and M.O.R.D. technical specification Clause 802, 804, 805, 806, 807,1202 and 1204 as per the direction of the Engineer-in-charge , including carriage of materials within all leads, lifts and other incidentals. The rates are inclusive of octroi, royalty, Malkana, toll tax , goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying mechanically mixed and vibrated reinforced cement concrete mix design to obtain minimum compressive strength of grade M-20 (M-twenty) design mix cement contents not les than 330 kg per cubic meter on ground in bed plate, dirt wall, pillar and wheel guards etecetra upto all heights in super structure including curing complete as per drawing and M.O.R.D. technical specification Clause 800, 1205.4 and 1205.5 including cost of form work but excluding the cost of reinforcement for reinforced concrete work in superstructure as per the entire satisfaction as per the direction of Engineer-in-charge including carriage of materials within all leads, lifts and other incidentals. The rates are inclusive octroi, royalty, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying mechanically mixed and vibrated reinforced cement concrete in super structure as per drawing and M.O.R.D. technical specification Clause 800, 1205.4 and 1205.5 designed to obtain the minimum strength of grade M-25 (M twenty five) design mix cement contents not less than 404 kg per cubic meter and curing complete including cost of form work but excluding the cost of reinforcement for reinforced concrete work in superstructure as per the entire satisfaction as per the direction of Engineer-in-charge including carriage of materials within all leads, lifts and other incidental. The rate including octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawings and technical specifications Clauses 1002, 1005, 1010 and 1202 including cutting, bending, binding and placing in position complete in all respect including cost of binding wire upto all heights including carriage of materials within all leads, lifts and other incidentals . The rates are inclusive octroi, royalty, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying cement concrete wearing course RCC grade M-30 (M-thirty) with cement contents not less than 420 kg per Cum ( Four hundred twenty kilogramme per cubic meter ), aggregate size not exceeding 20mm (twenty millimeter ) and including form work and reinforcement complete as per drawing and technical specification clause 800 and 1206.3 as per the direction of the Engineer-in-charge including carriage of materials within all leads, lifts and other incidentals. The rate is including of octroi, royality, Malkana, toll tax , goods service tax, labour cess or other taxes imposed by the Government.
Back filling with granular material behind abutment, wing wall and return wall complete as per drawing, direction of Engineer in charge and MORD technical specification clause 1204.3.8 including carriage of materials/machinery required to execute the work in all leads, lifts including other incidentals. The rates are inclusive octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Proving weepholes in brick masonry/ stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100mm (one hugoods service tax, labour cess ndred millimeter s) dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7 as per direction of Engineer-in-charge including carriage of materials with in all leads, lifts including other incidentals. The rate including octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government. .
Providing and fixing 20mm (twenty millimeter ) thick compressible fibre board in expansion joint complete as per drawing and technical specification as per the direction of the Engineer-in-charge including carriage of materials within all leads, lifts and other incidentals. The rate is including of octroi, royality, Malkana, toll tax , goods service tax, labour cess or other taxes imposed by the Government.
Construction of R.C.C. railing of M 25 (M-twenty five)grade in cast-in-situ with 20 mm (twenty millimeter s) nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm (two thousand millimeter s) as per drawing and technical specifications Clauses 800, 900 and 1208.3 and as per the direction of Engineer-in- Charge including carriage of materials within all leads, lifts and other incidental . The rates are inclusive octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Drainage spouts complete as per drawing and technical specification clause 1209 and as per the direction of Engineer-in- Charge including carriage of materials within all leads, lifts and other incidental . The rates are inclusive octroi, royality, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Providing and laying ( to level or slope) 900mm dia (nine hundred millimeter ) diameter reinforced cement concrete heavy duty non pressure pipes IS Class NP-2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1 : 2 ( One cement : two sand) but excluding the cost of excavation, protection works, back filling, concrete and masonry work in head walls and parapets as per drawing and technical specifications clause 1106 and as per direction of Engineer – in- Charge including carriage of materials within all leads, lifts and other incidentals . The rates are inclusive octroi, royalty, Malkana, toll tax, goods service tax, labour cess or other taxes imposed by the Government.
Gaurav Kumar
Mohit Sharma
Ajmer Singh Govt. Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .