Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹50.6 L+₹97,079 (1.96%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹50.9 L+₹1.3 L (2.57%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹51.7 L+₹2.1 L (4.17%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹51.9 L+₹2.3 L (4.60%)Rejected-Finance NETAJI SUBHAS ROAD SUBHASPALLY SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
24 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
REPAIR AND MAINTENANCE TO DUCTABLES ACs, MEGA SPLIT ACs, VARIOUS TYPES OF COOLING APPLIANCES AND CONNECTED ITEMS AT 20 WING AND 273SU AF STN UNDER GE (AF) BAGDOGRA
2022_MES_561595_2
8449/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹94,000
Yes
31 Dec 2022
9 Dec 2022
26 Dec 2022
9 Dec 2022
24 Dec 2022
17 Dec 2022
Amount
Sch 'A' Part-I Taking out unserviceable each blower motor from existing location of 3TR (Mega Split type) capacity of Split AC, Window AC, mega split/ductable outdoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enameled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing of existing and size and reassembling the blower motor and fixed complete all as directed by Engr -in - Charge. Note:- The retrieved burnt copper winding wire shall be handed over to MES store and RV obtained.
All as per item No 1 above, but capacity of 1.5 TR (Split/window type).
All as per item No 1 above, but capacity of 2 TR (Split/window type).
All as per item No 1 above, but capacity of 4.5TR (Mega Split type).
All as per item No 1 above, but capacity of 5 TR (ductable).
All as per item No 1 above, but capacity of 5.5 TR (ductable).
All as per item No 1 above, but capacity of 7.5 TR (ductable).
All as per item No 1 above, but capacity of 11.6 TR (ductable).
Taking out unserviceable blower motor from existing location of 3TR (Mega) capacity of Split AC Indoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enameled copper wire, varnishing heating and testing including replacement of unserviceable 2 nos. bearing and reassembling the blower motor and fixed complete all as directed by Engr -in - Charge:- . Note:- The retrieved burnt copper winding wire shall be handed over to MES store and RV obtained.
All as per item No 9 above, but capacity of 1.5 TR (Split/window type).
All as per item No 9 above, but capacity of 2 TR (Split/window type).
All as per item No 9 above, but capacity of 4.5TR (Mega).
All as per item No 9 above, but capacity of 5 TR (ductable).
All as per item No 9 above, but capacity of 5.5 TR (ductable).
All as per item No 9 above, but capacity of 7.5 TR (ductable).
S&F Aluminium fan blade each suitable for outdoor unit of 4.5TR capacity for split /mega ductable split type AC including taking down unserviceable one.
All as per item No 16 above, but capacity of 5/5.5 TR (ductable).
All as per item No 16 above, but capacity of 7.5 TR (ductable).
All as per item No 16 above, but capacity of 11.6 TR (ductable).
All as per item No 16 above, but capacity of 3TR (Mega).
All as per item No 16 above, but capacity of 1.5 TR (Split).
All as per item No 16 above, but capacity of 2 TR (Split).
S&F capacitor of 2.5 MFD capacity including taking down unserviceable one. (Make- Sarda/ Universal/Usha).
All as per item No 23 above, but capacity of 4 MFD.
All as per item No 23 above, but capacity of 8 MFD.
All as per item No 23 above, but capacity of 10 MFD.
All as per item No 23 above, but capacity of 12.5 MFD.
S&F running dual capacitor of 36+6 MFD capacity including taking down unserviceable one. (Make- Sarda/ Universal/Usha)
All as per item No 28 above, but capacity of 40+6 MFD.
All as per item No 28 above, but capacity of 45+6 MFD.
All as per item No 28 above, but capacity of 50+6 MFD.
All as per item No 28 above, but capacity of 60+6 MFD.
S&F 3 Pole power contactor of 9 Amps capacity including taking down unserviceable one.
All as per item No 33 above, but capacity of 25 Amps.
All as per item No 33 above, but capacity of 32 Amps.
All as per item No 33 above, but capacity of 40 Amps.
S&F MCCB 3 pole of breaking capacity 25 KA of following type complete all as specified and directed:- Thermal release type of Cap 63 Amp.
All as per item No 37 above, but Thermal release type of Cap 100 Amp.
S&F MCCB 4 pole of breaking capacity 25 KA of Thermal release type of Cap 125 Amp type complete all as specified and directed.
All as per item No 39 above, but Thermal release type of cap 160 Amp.
Dismantling unsv remote control assembly and replacing unsv items such as IC,PCB,Transformer and magnetic coil suitable for indoor 1.5 TR (Split/Window Type) capacity split type AC and reassembling the same after testing complete.
All as per item No 41 above, but capacity of 2.0 TR (Split/Window).
All as per item No 41 above, but capacity of 3 TR (Mega Split Type).
All as per item No 41 above, but capacity of 4.5 TR (Mega Split Type).
All as per item No 41 above, but capacity of 5/5.5 TR (ductable).
All as per item No 41 above, but capacity of 7.5 TR (ductable).
All as per item No 41 above, but capacity of 11.6 TR (ductable).
Dismantling the condensing coil and supply and fix the new condensing coil made of copper pipe of 1.5 TR Capacity Split AC/ Window type AC.
All as per item No 48 above, but capacity of 2 TR Capacity Split AC/ Window type AC
M&L for detecting leakage of Air conditioning system rectifying the leakage and testing complete all as specified and directed by Engr -in Charge of capacity 1.5 TR Split AC.
All as per item No 50 above, but capacity of 2 TR Split AC.
All as per item No 50 above, but capacity of 3 TR Mega Split AC.
All as per item No 50 above, but capacity of 4.5 TR Mega Split AC.
All as per item No 50 above, but capacity of 5 TR (ductable).
All as per item No 50 above, but capacity of 7.5 TR (ductable).
All as per item No 50 above, but capacity of 11.6 TR (ductable).
S&F V- Belt Size- A- 28 including taking down unserviceable one. (Make – Nirlon/ Fenner/Dunlop)
S&F suction/Discharge valve including taking down unserviceable one:- 1 1/8" (Make B/M/KEM/ Castle).
All as per item No 58 above, but of size 5/8" each.
All as per item No 58 above, but of size 1/2" each.
All as per item No 58 above, but of size 3/8" each.
All as per item No 58 above, but of size 1/4" each.
Supply & filling refrigerant gas R-22 for charging of 1.5 TR to 11.6 TR capacity split, mega split and ductable split type AC.
Supply only suitable refrigerant gas R-410a for charging of 1.5 TR to 11.6 TR capacity mega and ductable split type and VRF type Air Conditioner.
Supply only suitable refrigerant gas R-134A for charging of water cooler and refrigerators.
Attending the complaints as directed by the Engineer-in Charge for carrying any nature defects complete of Window type AC, Split, Mega split, Ductable Split AC specified and as directed. Note: (i) Supplying of new accessories/components required for the system shall be measured & paid separately as supply only. (ii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge. (iii) Completion of job will be considered only after complete rectification of defect upto satisfaction of Engineer -in - Charge (iv) Complaint shall be attended on the same day of obtaining complaints & intimate to JE in charge by evening. (v) Rate for necessary stationary for complaint register & complaint slips shall be deemed to include in quoted rate.
Dismantling of defective Window type AC/ Split type Air conditioner indoor/outdoor unit of any make of 1.5 TR capacity for thorough checking / repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed by Engineer – In – Charge including transportation to workshop and back. Note: (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after as supply only. (ii) Replacement of sealed compressor unit, painting etc shall be measured and paid separately. (iii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.
All as per item No 67 above, but capacity of 2TR.
S&F compressor rotary energy efficient/ reciprocal in replacement of old compressor having any No of cuts of same size , capacity and connecting with existing system testing to leakage including recharging of refrigerant gas after installation sealed unit with the split type AC of 1.5 TR capacity commissioning complete all as specified and directed. (Make- Hitachi/ Blue star/Carrier/ LG). (Note:- unserviceable compressor shall be the property of contractor)
All as per item No 69 above, but capacity of 2TR. (Make- Hitachi/ Blue star/Carrier/ LG).
Dismantling of window type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including brick work, plaster and making good by painting with existing color at old and new location complete all as specified and as directed.
Dismantling of Split type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including necessary civil work complete all as specified and as directed.
Disconnecting the electric connection and taking out AC of any capacity conditioner any capacity from wall overhauling and servicing the window type AC by help of Blower gun, Soap water etc, oiling greasing as required and painting the AC including outer cover after work the machine refixng in original position and reconnecting the electric connection and making serviceable and recharging the refrigerant gas. If required:- (a) Window type AC 1.5 TR/ 2TR. Note: If required extra refrigerant gas will be measured & paid separately as supply only.
All as per item No 73 above, but Split type AC 1.5 TR/2 TR.
S&F Copper refrigerant pipe of following size:- 3/8”
All as per item No 75 above, but size of 1/4”.
All as per item No 75 above, but size of 1/2”.
All as per item No 75 above, but size of 5/8“.
S&F Insulation for cooling line.
S& F Starting relay for 1.5 TR / 2 TR capacity of window / split type AC. (Make- Sriram/Annapurna/ Hi-teck)
S&F Sheet metal enclosure for SPN, with two pin earth plug and socket complete with one SP, MCB 20Amps including taking down.
Dismantling the u/s 15mm drain water pipe and supplying and fixing including provision of saddles/clamps upto 100 mm above the ground level.
S&F Air filter of suitable size for Split AC 1.5 TR type of AC unit.
All as per item No 83 above, but Split AC 2.0 TR.
S&F Air filter for Window AC 1.5/2.0 TR.
S&F Compressor suitable for following capacity and type of split type AC including taking down unserviceable one:- 3 TR reciprocal compressor Suitable for 3TR Mega split AC. (Make- Hitachi/ Blue star/Carrier/ LG). (Note:- unserviceable compressor shall be the property of contractor)
All as per item No 86 above, but 4.5 TR reciprocal compressor Suitable for 4.5TR Mega split AC. (Make- Hitachi/ Blue star/Carrier/ LG).
All as per item No 86 above, but 5 TR reciprocal compressor suitable for ductable type. (Make- Hitachi/ Blue star/Carrier/ LG).
All as per item No 86 above, but 5.5 TR scroll compressor ductable type. (Make- Hitachi/ Blue star/Carrier/ LG).
WATER COOLER Servicing to water cooler capacity 40/80, 60/120 & 150 ltrs for thorough checking including all accessories and components replacement of defective accessories/ components & testing complete all as specified and as directed. Note: (a) New accessories / components required shall be measured and paid separately. Labour charges for fixing are deemed to be included in the unit quoted rate. (b) Repair, overhauling, rewinding motor, replacement of sealed compressor unit re- charging of compressor oil and refrigerant gas etc shall be measured and paid separately. (c) old serviceable accessories / components removed shall be refixed as directed by Engr - in charge rate for fixing shall be deemed to be included in the unit rate of item above.
Supply only Aluminium fan blade suitable for water cooler of capacity 40 / 80 Ltrs).
Supply only aluminium fan blade suitable for water cooler of capacity 120 & 150 Ltrs.
Supply only wiring set complete of PVC insulated cable stranded copper conductor connecting clip etc suitable for any capacity of water cooler.
Supply only thermostat with plastic regulator knob suitable for any capacity water cooler.
Supply only relay switch for water cooler suitable for (As per sample) any capacity of water cooler. MODEL – 412/ 412Y.
Supply only over load protector type 1022 for any capacity of water cooler.
Supply only self closing chromium plated brass bib tap/ push tap 15mm dia suitable for any type / capacity of water cooler.
Supply only 15 mm dia Float valve synthetic metal along with PVC ball and AI connecting rod complete with all accessories.
Supply only running capacitor 25 Mfd 415 Volts AC, 50 Hz.
Supply only starting capacitor 80-100 Mfd 415 Volts AC, 50 Hz.
S&F compressor rotary energy efficient /reciprocal for water cooler and connecting with existing system testing for leakage including re-charging of refrigerant gas after installation sealed unit with the water cooler of following capacity commissioning including dismantling unserviceable one complete all as specified and directed:- 40/80 litres. (Make- Hitachi/ Blue star/Carrier/ LG). Note:- Refilling of R-134a gas shall be measured & paid separately.
All as per item No 101 above, but capacity of 60/120 litres. (Make- Hitachi/ Blue star/Carrier/ LG).
Recharging of refrigerant gas R-134a after vacuuming dehydration leak testing for the system as per standard practice and rectifying / arresting the same by brazing to copper tubing for proper cooling and satisfactory performance complete all as specified and as directed for water cooler of following capacity:- 40/80 ltr/hrs. Note:- Supply only for Gas R-134a shall be measured & paid separately.
All as per item No 103 above, but capacity of 60/120 Ltr/hrs.
Opening blower motor of any type / make cutting removing of the worn out copper wire cleaning the armature, rewinding the same with existing size of super enamel, copper wire including necessary insulating tubes and replacement of bush and testing complete:- 40/80 litres. Note:- The retrieved burnt copper winding wire shall be handed over to MES store and RV obtained.
All as per item No 105 above, but capacity of 60/120 Ltr/hrs.
All as per item No 105 above, but capacity of 150 litres.
REFRIGERATOR Dismantling of defective refrigerator of any make and any type capacity for through checking of all accessories and components, repair & reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed. Note : (a) New accessories / components required shall be measured and paid separately labour charges for fixing shall be included in the unit rate. (b) Replacement of sealed compressor unit Gas charging painting etc. shall be measured and paid separately. (c) Old serviceable accessories / components obtained after dismantling shall be refixed as directed and labour charges for refixing shall be deemed to be included in the unit rate
Supply only Cooling coil chamber including cooling coil for 175/210 ht refrigerator.
All as per item No 109 above, but capacity of 280/335 Ltr.
Supply only Thermostat defrost type including plastic regulating knob.
Supply only Relay switch.
Supply only Lamp screwed / pin type including 15 Watts lamp 220 Volts.
Supply only Timer.
Supply only Bimetal relay.
Supply only Condenser coil.
S&F compressor rotary energy efficient/reciprocal for Refrigerator of following capacity of original manufacturer and connecting with existing system testing to leakage including recharging of refrigerant Gas after installing sealed unit to refrigerator of following capacity commissioning including dismantling unserviceable one complete all as specified and directed:- 175-210 litres. (Make- Hitachi/ Blue star/Carrier/ LG).
All as per item No 117 above, but capacity of 280-335 Ltr. (Make- Hitachi/ Blue star/Carrier/ LG).
DEEP FREEZER Dismantling of defective deep-freezer capacity 205 to 500 ltrs for through checking including all accessories and components reassembling the same after repair/ replacement of defective accessories/ components & testing complete all as specified and as directed Note: (a) New accessories / components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate. (b) Repair of over hauling rewinding compressor motor, repair/ replacement of sealed compressor unit recharging of compressor oil and refrigerant gas etc shall be measured and paid separately. (c) old serviceable accessories / components removed shall be fixed as directed for fixing shall be deemed to be included in the unit rate.
Supply only the Blower motor fan blade for deep freezer 205 to 320 litres.
Supply only Wiring set complete of PVC insulated cable stranded copper conductor connecting clip for deep freezer.
Supply only Thermostat which including plastic regulator knob for deep freezer. Make – INDFOSS/WHIRPOOL/ ANNAPURNA.
Supply only Relay switch for deep freezer. Make : SHRIRAM/ ANNAPURANA.
Supply only Overload protector for deep freezer. Make: SHRIRAM/ RANUTROL/HI-TECK.
S&F compressor rotary energy efficient/reciprocal and capacity of original manufacturer and connecting with existing system testing to leakage including recharging of refrigerant Gas after installing sealed unit to refrigerator of following capacity commissioning including dismantling unserviceable one complete all as specified and directed. 205 to 320 Ltrs Capacity. (Make- Hitachi/ Blue star/Carrier/ LG).
Dismantling of defective mega split and ductable split unit of any make of following capacity for thorough checking / repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed by Engineer – In – Charge including transportation to workshop and back:- 4.5 to 11.6 TR mega split. Note : (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after. (ii) Supply of sealed compressor unit, painting etc shall be measured and paid separately. (iii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.
S&F MCB TPN of following capacity including taking down unserviceable one:- 25 Amps. (Make- Havells/ Legrand/ Seimens/ L&T).
All as per item No 127 above, but capacity of 32 Amps.
All as per item No 127 above, but capacity of 40 Amps.
S&F following components suitable for existing VRF unit of capacity 10HP and 12HP complete all as specified and directed:- Cordless controller.
All as per item No 130 above, but Corded controller.
All as per item No 130 above, but Y-joint / Distribution joint.
S&F Copper refrigerant pipe of following size:- 1 1/8”.
All as per item No 133 above, but size of 3/8”.
All as per item No 133 above, but size of 5/8“.
Sch 'A' Part - II Comprehensive maintenance of ductable / Mega split type Air conditioner of following capacity of any make .The job includes as under;- (i) Inspection, checking, cleaning with soap water and carbon tetra chlorite to the cooling coil and condenser unit (ii) Inspection, checking and repair of all electrical components (iii) Servicing of blower motors by greasing, oiling and servicing by cleaning thoroughly air filter iv) During the servicing of the unit existing refrigerant (Gas) shall be pump down and to kept safe custody for re use Note : (a) Above job shall be carried out once in a every Qtr (b) Unserviceable item involving the above job shall be measured and paid separately (a) 8.5 TR to 11.6 TR (indoor unit 14 Nos & Out door unit 14 Nos)
Comprehensive maintenance of VRF type Air conditioner of any make.The job includes as under:- (i) Inspection, checking, cleaning with soap water and carbon tetra chlorite to the cooling coil and condenser unit. (ii) Inspection, checking and repair of all electrical components. (iii) Servicing of blower motors by greasing, oiling and servicing by cleaning thoroughly air filter. (iv) During the servicing of the unit existing refrigerant (Gas) shall be pump down and to kept safe custody for re use. Note: (a) Above job shall be carried out once in a every Qtr. (b) Unserviceable item involving the above job shall be measured and paid separately.(a)TXR Bldg (Indoor and outdoor units).
All as per item No 137 above, but GCA Bldg (Indoor and outdoor units).
(c) Base Ops (Indoor unit Ductable type, Cassette units , Hi-wall unit and outdoor unit).
Comprehensive maintenance of ductable / Mega split type Air conditioner of any make. The job includes as under:- (i) Inspection, checking, cleaning with soap water and carbon tetra chlorite to the cooling coil and condenser unit. (ii) Inspection, checking and repair of all electrical components. (iii) Servicing of blower motors by greasing, oiling and servicing by cleaning thoroughly air filter.B183 iv) During the servicing of the unit existing refrigerant (Gas) shall be pump down and to kept safe custody for re use. Note : (a) Above job shall be carried out once in a every Qtr. (b) Unserviceable item involving the above job shall be measured and paid separately.(a) GCA,PAR (Indoor and outdoor units).
All as per item No 140 above, but WSA (Indoor & Out door units).
All as per item No 140 above, but Signal Sec HQ (Indoor and outdoor units).
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
M/S East India Traders
KD SAHA and CO.INDIA
M/S BIJAY KUMAR SHIVA
SARKAR ENGINEERING CO.
M/S SARKAR ELECTRIC
M/S ANNI ENTERPRISE
M/S POWER ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .