| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹17.0 L+₹1.7 L (11.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹18.0 L+₹2.8 L (18.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹19.5 L+₹4.2 L (27.6%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹19.9 L+₹4.7 L (30.7%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Dec 2024, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF CEILING FAN EXHAUST FAN AND OTHER CONNECTED WORKS MD AND OTM ACCN AT SI LINES AND SUKHI SEWANIA UNDER GE BHOPAL
2024_MES_686259_1
8322/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹50,000
Yes
10 Feb 2025
29 Nov 2024
27 Dec 2024
29 Nov 2024
25 Dec 2024
13 Dec 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Dismantling of ceiling fans AC single phase, 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per item No.1.00 here-in-before but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts.
All as per item No.1.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts.
All as per item No.1.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts.
All as per item No.1.00 here-in-before but wall / pedestal fan, of any sweep and capacity Note for Item No. 1.00 to 5.00 (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before star work (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
S&F in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed.
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement flexible copper conductor stranded 1100 Volt PVC insulated cable three core 23/0.0076 size complete all as specified and directed.
S&F in replacement fan condenser 2.5 Mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 3.15 Mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 4.0 Mfd, 230 volts complete all as specified and directed.
Supply only the following items for fixing against defective parts of fan taking down under item No 1.0 here-in-before complete all as specified and directed.
(a) Bearing No 6201'ZZ'
(b) Bearing No 6202'ZZ'
(c) Bearing No 6203'ZZ'
(d) Bearing No 6204'ZZ'
Taking down ceiling / wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i.e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i.e. connector/condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re-fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long 19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long 19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement Exhaust fan metal blade duly powder coated suitable for 450 mm/380mm sweep as per existing complete all as specified and directed.
S&F in replacement Exhaust fan metal blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1400 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan (any sweep) of make, colour and pattern as per existing model complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of ceiling fan upto 1200/1400 mm sweep with two coats of DUCO paint (ISI grade) white using spray machine. Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under item No. 1 here-in-before.
All as per item No. 27.00 here-in-before but for exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
S&F of ceiling fan regulator electronic, step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and directed.
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nut and bolt, etc and reassembling, re-fixing and testing the fan complete all as specified and directed.
Removing unserviceable fan / bearing shaft (of any type & fan) and shaft welding broken area and threading in lathe machine at appropriate size and refixing in ceiling fan, any type complete all as specified and directed.
Taking down unservicable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for concealed, point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and directed. Note: Cost of cutting chase and making good shall be included in the quated rates.
All as per item No. 36.00 here-in-before but for one switch socket combination 5/6 Amp on independent board.
All as per item No. 36.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches.
All as per item No. 36.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per item No. 36.00 here-in-before but for one switch socket combination 6 pin 5/15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.
M&L for Casing caping/conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and directed. Note: Cost of cutting chase and making good shall be included in the quated rates.
All as per item No 41.00 here-in-before but for one switch socket combination 5/6 Amp on independent board
All as per item No 41.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches
All as per item No. 41.00 here-in-before but for one switch socket combination 6 pin 5/15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per item No. 41.00 here-in-before but for one switch socket combination 6 pin 5/15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.
S&F in replacement building security light fitting complete with 36 watt LED, type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector complete all as specified and directed.
S&F of switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1 having provision for 3 pin, 6 Amp piano flush type, 230 volt AC complete all as specified and directed.
S&F of switch socket combination, multipurpose, 3 pin, 5-15 Amp, flush type, ISI marked complete all as specified and directed.
Dismantling geyser of 25 ltrs capacity and of any description and M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of sch (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares as required shall be measured and paid seperately.
All as per item No. 50.00 here-in-before but geyser of capacity 50 Ltrs.
S&F of 1.5 KW capacity Heating element (ISI marked), round type/thread/triangle/Push/Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F 2.0 KW capacity Heating element (ISI marked), round type/thread/triangle/ Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F electronic Heating element (ISI marked) fitted with auto cut thermostat 1.5/2.0 KW suitable for 25/50 ltr geyser including making electrical connection complete all as specified and directed.
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement Indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of Geyser 25 ltr capacity with two coats of DUCO paint (ISI grade) white using spray machine spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos complete all as specified and directed.
All as per item No. 65.00 here-in-before but of Geyser 50 ltr capacity
S&F in replacement single pole and neutral, sheet metal enclosure with two pin and earth, plug and socket, suitable for single phase 240 V,complete with and including one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top complete all as specified and as directed.
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in replacemnt PVC connections 15 mm size Nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified & directed.
S&F in replacement LED decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed.
S&F in replacement coral post top lantern fitting 25 Watt, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories all as specified and directed.
S&F in replacement LED tube light complete fitting, surface mounted luminanaires, 40 watt, 240V, decorative ultra slim round/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed.
S&F in replacement of warm white LED Tube light fitting two feet 10 Watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fittting connector complete all as specified and directed.
S&F of PVC insulated unsheathed, ISI marked FRLS copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F of PVC insulated unsheathed, ISI marked FRLS copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S&F of modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular Bell Push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
S&F of modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
S&F of modular fan regulator, 5 step, high speed complete all as specified and directed.
S&F of modular metal flush box of 6 module complete all as specified and directed.
S&F of modular metal flush box of 4 module complete all as specified and directed.
S&F of modular metal flush box of 3 module complete all as specified and directed.
S&F of modular white cover plate with frame of 6 module complete all as specified and directed.
S&F of modular white cover plate with frame of 4 module complete all as specified and directed.
S&F of modular white cover plate with frame of 3 module complete all as specified and directed.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including MCCB/MCB and wooden boards complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 Amps rated busbar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and directed. Note:- MCB shall be measured and paid seperatly.
S&F of factory made epoxy powder coated distribution board TPN, 4 ways (VTPN, MCCB DB) and space for MCCB as incomer with metal door (IP-54 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed. Note:- MCCB shall be measured and paid seperatly.
S&F of sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, IP 43 ISI marked 200 amps bus bar dust and vermin proof (IP-54 protection) suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid separately.
S&F of sheet metal enclosure double door type surface mounted concealed in wall, 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof IP-54, suitable for incorporation MCBs and isolators etc complete all as specified and directed. Note:- MCB shall be measured and paid separately.
S&F of MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 40 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SPN suitable for 240 volts, 'B' curve,AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
S & F in repairs MCB SPN suitable for 240 volts, 'B' curve, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve,AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve,AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed.
Dismantling water tanks of capacity exc 250 litres but nexc 500 litres and removing to store complete all as specied and directed
Dismantling water tanks of capacity exc 500 litres but nexc 1000 litres and removing to store complete all as specied and directed
S&F 500 ltrs capacity rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed
S&F 1000 ltrs capacity Rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 including20mm dia tank nipple complete all as specified and directed
S&F in repair to 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc
S&F in repair to 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of TerbacG5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend terbac G65/ Inoxi-60/ NB-69. Note:-(i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity exceeding 500 Ltr but not exceeding 1000 ltrs of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of Terbac G5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend terbac G65/ Inoxi-60/ NB-69. Note:-(i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
S&F of factory made RCC earth pit chamber with cover of size 450mm x 450 mm x 150 mm, 50 mm thick complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 51376.00
Makewell Enterprises (BID ID -3198413)
MODI CORPORATION (BID ID -3190749)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3198470)
S S TRADERS (BID ID -3192462)
UMESH ENTERPRISES (BID ID -3197723)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .