Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.2 L+₹2.1 L (33.8%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹8.4 L+₹2.2 L (35.6%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹10.0 L+₹3.8 L (62.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹19,700
Closing Date
21 Sept 2020, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF SMOKE DETECTOR AT UNIT CHOK LAB AND AFNET EQUIPMENT ROOM AT CTI AF STN JALAHALLI
2020_MES_361709_2
85173
Open Tender
Civil Works
Item Rate
150 days
Jalahalli Bangalore
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (M) (AF) Jalahalli
₹19,700
Yes
9 Dec 2020
1 Sept 2020
23 Sept 2020
1 Sept 2020
21 Sept 2020
9 Sept 2020
1 Sept 2020 - 7 Sept 2020
Amount
Supply & fix smoke and heat detectors, photoelectric / optical type certified to EN 54 addressable with self built intelligent with connected accessories complying with optical chamber, cover, case molding, photodiode (transducer), infrared LED all as specified and directed. NOTE:- i).Metal junction box of suitable size for detector made of 16 SWG sheet steel is to be provided for mounting of detectors in the concrete mother ceiling / surface along with necessary gland and boxes duly painted with two coats of super enameled paint over a coat of red oxide primer. ii) Rate of metal boxes shall be including in quoted rate of items.
Supply ,installation ,testing and commissioning 2 core solid conductor of size 1.5 sqmm, as per IS-1554 PVC insulated & PVC sheathed, armoured cable FRLS down through non metallic PVC conduit of suitable size shall be properly clamped to the ceiling / surfaces and 'S' loop shall also be left where cables connect to sounders, panels and all the cables and wires shall be tagged for proper identification complete all as specified and directed.
S & F microprocessor based automatic fire alarm control panel complying with BSEN54 Single loop panel input volatage 230V AC (+-- 10% TO 15 %), 50Hz , output 21.5-28.5 V DC, with battery microprocessor based automatic fire alarm control panel complying with BSEN54 single loop panel provide battery with box backup upto 24hrs. in standby mode and 15 minutes in alarm condition, 4KV surge protection complete the control panel capable for 99 detectors and 99 module upto 200 detector complete all as specified and directed
S & F of response indicator complying in ABS housing small with dual LED indicator, input volts 24V complete all as specified and directed by Engineer in Charge
S & F of manual call box flush / semi flush with operating temperature 30 to 70 degree Celsius , IP rating 24V, 15V to 30V max , integral LED, integaral loop isolation re-settable operating element option complete all as specified and directed by Engineer In Charge
S & F hooter (addressable sounder) medium intensity supply voltage 15 to 24V DC operating temperature 25 to70 Deg C with volume setting for high, medium, low and ingress protection IP65 complete all asa specified and directed by Engineer In Charge.
devan enterprises
M/S SRI BALAJI ENTERPRISES
B5BUILDING SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .