Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.0 L+₹3.0 L (22.9%)Rejected-Finance FLAT NO 8 205 SNO 296 2 DIVINE HOMES PORWAL ROAD KSHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹18.6 L+₹5.6 L (42.9%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹20.4 L
EMD Value
₹40,700
Closing Date
24 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
PROVISION OF CERTAIN LBW, REV AND MINOR WORKS AT CME
2021_MES_455673_1
8194/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class E a(i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹40,700
Yes
22 Nov 2021
29 Jun 2021
26 Jul 2021
29 Jun 2021
24 Jul 2021
11 Jul 2021
30 Jun 2021 - 10 Jul 2021
60 days
Amount
Surface excavation n.exc (not exceeding) 30cm deeep and averaging 15 cm, deep and getting out in hard/dense soil complete all as specified and directed.
M & L for excavation in trenches not exc 1.50m wide and not exc 1.50m depth for foundation etc n. exc 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
M & L precast solid block masonry of block 1:3:6 type C-1 wall exceeding 10 cm in width and built in cement mortar 1:4 complete all as specified and directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layerws n.exc. 15cm thick spread, leveled and rammed including watering complete all as specified and directed.
M & L hardcore using broken stone boulders not exceeding 63mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified and directed.
M & L 75mm PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M & L 100mm thick cement concrete type B2 1:2:4 (40mm garded stone aggregate) with out using extra cement finishing concrete surface even and smooth as in floor complete all as specified and directed.
M & L forming construction joint 30mm deep x 10mm wide filled with sealing compound garde 'A' complete all as specified and directed.
M & L 15mm thick plastering on concrete surface in CM 1:4 finsihed even and smooth without using extra cement complete all as specified and directed.
M & L preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M & L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
M & L for fine aggregate (crushed sand) for sand cousioning complete all as specified and directed.
M & L machine pressed precast concrete interlocking pavour block with grey cement and pigment any shape and sizeconforming to IS 15658-2006 of 60mm thickness M-35 grade with glossy finish colour shade complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed.
Removing excavated material n.exc 50m and deposting where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for providing & fixing 12 mm thick gypsum board in ceiling (two or three stages if reqd) including GI U-section 50 mmx35mmx7mm & edge side GI U-section size 30mmx25mmx15mmx7mm fixed with screw gypsum board and frame grid suspended with soffit cleat to roof slab for hanging 4 mm dia GI hanger rod with adjustable level clips, after fixing of gypsum board joints/junction of gypsum board ceiling to be covered with 50 mm to 100mm corner strips, Rounds at fan & Lights, cut for cassette AC indoor unit and light complete all as specified and as per manufacture’s instruction and applying two coats of Luster Paint over 3 mm POP to visible side of gypsum board ceiling shade/tint complete all as specified and directed by Engr-in-charge.
S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed.
M&L preparing New Steel and Iron Surfaces of any descriptions, over 100mm in width or girth and applying Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M & L cutting hole in brick walls/stone walls exc half brick but not exc one bricks for any purpose and making good dismantled portion in cement mortar 1:3 or cement concret 1:2:4 type B-1 as required complete all as specified and directed by Engineer-in Charge.
Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
Supply, laying jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 4 core complete all as specified and directed.
Supply and fix Servo Voltage stabilizer for automatic operation, three phase, naturally air cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 20 KVA Make: Bluestar/V-Guard/ Brent Ford/ Vinitec/ Automatic Electric or other equivalent make as approved by Engineer-in-charge.
S&F MCB distribution board TP&N Vertical Loadline (Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates without MCCB) suitable for TP/FP ‘A FRAME’ MCCB - 250A double door 415 volts 12 way of Cat Part No DHDLVDRWAOFO12 of Havells and making good to disturbed surfaces of floors walls all as specified and directed by Engineer-in-charge
Supply and fix 4 pole MCCB of 250A capacity with S.C. rating of 20kA,adjustable thermal and fixed magnetic setting with provided leads on iron frame/lamination board all as specified and directed .
Supply and Fix Recess mounted LED downlighter 21/25 W elegantly designed pressure die-cast Al. heat shrink for efficient heat dissipation and separate replaceable electronic driver compatible for Analog/DAIL Dimming of ceiling cutout dia 180mm, height 68mm of Cat part No: ENDURANEODLR25WLED857M & ANALOGDRIVERNM21/25W of Havells incl taking down old unserviceable one of any size and any type all as specified and directed by Engineer-in-charge
S&F ‘C’ Series MCB 63A TPN 240 V/415 V, 50 Hz, 10 kA Cat part No DHMGCTNF063 of Havells or equivalent of Indoasian/Standard/HPL complete all as specified and directed.
S&F ‘C’ Series MCB 4 pole rated capacity 6 to 32 Amp, 240 V/415 V, 50 Hz, 10 kA Cat part No DHMGCFPF006-032 of Havells or equivalent of Indoasian/Standard/HPL complete all as specified and directed.
S&F of MCB single pole rated capacity 6 to 32 Amp, 240 V breaking capacity 9kA, C series complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, Ceiling rose, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
M&L for point wiring for light/fan/Bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC non metallic rigid conduits 20 mm or higher dia as required at site, totally concealed in walls / floors /ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cupwashers, for mounting of switches, sockets fan regulators etc; complete all as specified and directed for one light point controlled by one switch & making good to disturbed surface of wall etc complete all as specified and directed.
All as per item No 31 above but for 5 pin 5 amps socket outlet on same board with other switches
All as per item No 31 above but for 5 pin 5 amps socket outlet on independent board with other switches
All as per item No 31 above but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent board.
S&F Modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
S&F socket modular 6A/16A, 2/3 pin combined 2 module with suitable plate and cover complete all as specified and directed
S& F Flexible led strips with uniform light distribution and long lasting adhesive for perfect cover lighting solution, lamp type Flexion Led Strip 24 W 6000 K,code LHEHCPP7NN1W024 of Havells or equivalent with Constant Voltage 12 V 2 A DRIVE all as specified and directed by Engineer-in-charge
M & L for Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for following sizes :-
25 mm external dia
40 mm external dia
S&F Modular switches one way and 6 Amp, 1 module, 230 volt complete all as specified and directed.
S&F switch modular one way 16 amps, 1 module with suitable plate and cover complete all as specificed and directed
S & F triple pole and earth sheet metal encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 A for 4 TR cassette type AC all as specified and directed by Engineer-in-charge.
Supply and fix single point air termination aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed.
M&L for earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Supply & fix aluminium strip 25 mm x 3.15 mm complete with saddles and fixing screws complete all as specified and directed.
Supply & fix GI strip 32 mm x 6 mm burried in ground complete all as specified and directed.
Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 block size 250 x 250 x 300 mm for holding GI pipe post for air terminal complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for GI Strip around the bldg and getting out in soft/loose soil complete all as specified and directed.
M&L for 40 mm dia galvanised pipe light grade fixed to wall or ceiling incl all fittings for holding air termination rod complete all as specified and directed.
BSK Construction
UNIQUE ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .