SE ETC-I, Kanpur
SE ETC-I, Kanpur
Work
2020_UPTCL_541924_1
ET-124/ETC-I(K)/2020-21
Open Tender
Electrical Works
Fixed-rate
90 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹236
PNB Account No 0727002100004177
₹4,000
1 Jul 2021
30 Dec 2020
25 Feb 2021
30 Dec 2020
25 Feb 2021
30 Dec 2020
120 days
Amount
Safe carriage of 40 MVA T/F control & Relay Panel (Siemens make) from 132 KV S/S Jainpur to 132 KV S/S Pukhrayan Kanpur Dehat by private carrier (approximate distance 45 Km.). The job includes shifting, loading & unloading work etc. by crane safely & carefully.
Dismantaling of old and used (ABB make) Control & Relay panel in control room after opening of cable connections and cutting of earthing strip including shifting of panels up to substation store at 132 KV S/S Pukhrayan.
Shifting of 40 MVA T/F Control & Relay panel (Siemens make) from S/S store to control room safely & carefully by manual labour approximate distance 30mtr. at above S/S. Grouting also to done if required.
Erection of Siemens make 40 MVA T/F Control & Relay panel at above dismantled place as per proper alignment and direction of incharge engineer with making earthing by M.S. flat (25x6mm/50x6mm) as per site requirement.
Making termination of all control cable alongwith proper feruling and proper fastening of cable glands of proper size of above control panel. (Cable glands & ferrules etc. shall be arranged by contractor at his own cost)
Checking of all wiring cabling, indication, alarm by matching the same with protection/indication including proper testing of panel for commissioning.
Dismantling of old & used double feeder (132 KV Kalpi & Sikandra) control panel after opening of cable connection and cutting of earthing strips including shifting of panels up to substation store (Approx. distance 400mtr.)
Shifting of new double feeder panel from S/S store to control room safely & carefully by hyadra and manual labour approximate distance 400 mtr.
Erection of double feeder control panel (Kalpi feeder & Sikandra feeder) at above dismantled place as per proper alignment and direction of Engineer incharge with making earthing by M.S. flat 25x6/50x6mm
Making connection feeder wise as per cable schedule with providing gland and ferrules after drilling of hole in base plate of panel and commissioning work.
Dismantling of old and used defective 33 KV triple feeder panel in control room after opening of cable connections and cutting of earthing strip including shifting of panels up to substation store.
Shifting of new 33 KV triple feeder panel from S/S store to control room safely & carefully by manual labour approximate distance 20 mtr.
Erection of new 33 KV triple panel feeder at above dismantled place as per proper alignment and direction of Engineer incharge with making earthing by M.S. flat 25x6/50x6mm
Making connection feeder wise as per cable schedule with providing gland and ferrules after drilling of hole in base plate of panel and commissioning work.
B.S. ENTERPRISES
R.K.ENGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .