Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹50.2 L+₹2.0 L (4.05%)Rejected-Finance 10 324 17 BALAJI NAGAR ARUVANKADU COONOOR THE NILGIRIS TAMIL NADU 643202 | COONOOR | THE NILGIRIS | TAMIL NADU | 643202 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.8 L+₹2.6 L (5.33%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹51.1 L+₹2.9 L (5.93%)Rejected-Finance 5 127 16 GANESH GARDEN KADAMPADI SULUR COIMBATORE TAMILNADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.1 L+₹3.9 L (8.01%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,200
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF MODERN ACCESSORIES, PARTITION WALL INCLUDING ADDITION / ALTERATION AND MINOR WORK AT AFS SULUR
2023_MES_618028_1
8607/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,200
Yes
21 Oct 2023
9 Sept 2023
2 Oct 2023
9 Sept 2023
30 Sept 2023
22 Sept 2023
9 Sept 2023 - 19 Sept 2023
Amount
SCHEDULE A BOQ
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
M&L PCC 100 mm thick in 1:4:8, type D-2 using 40 mm graded stone aggregate, as in sub base flooring complete all as specified and directed.
M&L PCC 40 mm thick in 1:2:4, type B-0 using 12.5 mm graded stone aggregate, as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
S & F copper strips of size 20 x 3 mm as in grid of size 300x300mm centre to centre over concrete sub floor for antistatic flooring including exothermic welding in all joints complete all as specified and directed
M&L treating cement concrete or granolithic concrete surfaces with three dressings of sodium silicate solution complete all as specified and directed.
S & F 3 mm thick glass dividing strips of width 38mm inserted in position and conform to design complete all as specified and directed.
S & F 600x600x10 mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet of size suitably placed in false ceiling grid made of G.I. complete all as specified and directed.
S & F powder coated Gl frame work of grid size 605x605mm for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S & F Hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed
S & F aluminium powder coated door frame of size 101.6x44.45x3.00mm (section No 20067) weighing 2.342Kg/m, shutter with vertical member of size 47.62x44.45x2.02 mm (section No 19569) weighing 1.052 Kg/m, Top horizontal frame of size 47.62x44.45x1.74mm (section No 19528) weighing 0.881 Kg/m, bottom horizontal frame of size 95.25x44.45x1.70mm (section No 19529) weighing 1.301 Kg/m, middle horizontal member of size 49.91x44.45x1.6mm (section No 19575) weighing 0.882Kg/m with glazing clip for shutter including fabrication to required size and partly panelled with 5mm colour tinted float glass at top portion, 12mm thick both side decorated prelaminated particle board at bottom portion including with necessary fittings, like powder coated decorative aluminium handles, hinges, glazing clips, rubber neoprene packing, snap beading screws, mortise lock heavy duty, and door stopper etc complete all as specified &directed by Engr-in-charge.
S & F aluminium powder coated two track sliding window frame top & sides of size 62x29.5x1.5mm (section No 21138) weighing 0.807 Kg/m, frame bottom of size 62x29.5x1.5mm (section No 21139) weighing 0.902 Kg/m, shutter with vertical members of size 39x20x2mm (section No 21093) weighing 0.643Kg/m, shutter interlock vertical member of size 39x20x2mm (section No 21094) weighing 0.743Kg/m, shutter top & bottom horizontal member of size 40x20x1.5mm (section No 20551) weighing 0.484Kg/m with one or more rebates without sash bar including 5 mm thick tinted float glass with rubber neoprene packing, handles, snap beading scews etc complete all as specified and as directed.
Note for item No 14 & 15 :- The minimum thickness of powder coating shall be 50 micron
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty all as specified and directed.
S&F framed work such as grills , grating ,etc with ends of bars shouldered and or reveated for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways railing framed work for water tanks similar work confirming to Fe -290 Gde E-165 complete all as specified and as directed.
M&L rendering 10 mm thick on brick or concrete wall surfaces, in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Note for item No 21 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
Demolition of brick work built In cement mortar,including all quoin, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets of spacing not exceeding 15 cm complete all as specified and as directed.
Dismantling of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified or as directed
Excavation over areas not exceeding 1.5m deep and getting out in hard and dense soil complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and as directed.
M&L PCC 1:4:8, type D-2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
S&F High strength corrosion resistant TMT steel bars of Grade Fe–500 of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and directed.
M & L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished flat surfaces of concrete complete all as specified and as directed.
M & L formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc., vertical or to batter with rough finished flat surfaces of concrete complete all as specified and as directed.
M & L reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in footing, foundation beams, plinth beams, bases for columns etc and mass concrete etc complete all as specified and as directed
M & L reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like with any thickness, above top of footings, including attached pilasters and buttresses etc complete all as specified and as directed
M & L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L PCC 100 mm thick in 1:3:6, type C-2 using 40 mm graded stone aggregate, as in sub base flooring complete all as specified and directed.
M&L PCC 100 mm thick in 1:2:4, type B-1 using 20 mm graded stone aggregate, as in flooring complete all as specified and directed.
S&F in repairs double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty all as specified and directed.
S & F vitrified ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
M&L Fly ash brick work using old size bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L Rendering 15 mm thick on brick or concrete wall surfaces, in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L applying two coats of cement based paint over one coat of primer including preparation over newly plastered wall surfaces of any description, complete all as specified and as directed.
M&L Preparation of newly plastered surfaces of wall and applying two coats distemper oil emulsion over a coat of primer and 3mm thick wall care putty complete all as specified and directed.
S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
Note for Item No 57:- (Pre-painted coloured Galvalume roofing) :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt, welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified and directed.
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 11 to 15mm complete all as specified and directed.
S & F Mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, gusset plates, wind ties etc conforming to Fe 410-w (Gde E-250) quality B complete all as specified and directed.
Removing demolished building materials to a distance exceeding 1.5 KM but not exceeding 5KM and depositing where directed complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed.
S&F Decorative laminates of 0.90 mm thick type 1 of surface finish, colour and pattern as approved and fixed with approved adhesive complete all as specified and as directed.
S & F 18mm thick, 7 ply, plywood, grade BWR, type BB fixed to wooden frame work in wall with nails complete all as specified.
S & F Stainless steel spring hinges of size 150mm of approved pattern and make suitable for base/wall unit of modular kitchen complete all as specified and as directed.
S&F Magnetic catches with 8mm dia steel ball and brass body and striking plate complete all as specified and directed.
S&F Stainless steel telescopic slider of 500 mm of approved pattern and make suitable for drawer in base unit of modular kitchen complete all as specified.
S&F Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete all as specified and as directed.
S&F stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen complete all as specified and as directed.
S & F 65 mm brass, 4 lever, cupboard lock complete all as specified and directed.
S&F 40 mm dia cupboard knobs fixed with nut, screw and washer of brass polished complete all as specified and as directed.
S&F Plate rack of size 65 cm x 96 cm made of stainless steel complete all as specified and directed.
M&L 18/19mm thick Prelaminated particle board, interior Grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
M & L framed second class hard-wood clean sawn timber in scantlings complete all as specified and directed.
M & L for second class hard wood plain fillets square, rectangular or triangular in section exc 3sqcm and not exc 6sqcm, clean sawn, secured with nails or brads complete all as specified and directed.
M & L for second class hard wood plain fillets bull nosed, splayed, chamfered or rounded on one edge or face, not exc 3sqcm, clean sawn, secured with nails or brads complete all as specified and directed.
M & L preparation of new wooden surfaces of any description, width or girth exc 10 cm and applying two or more coats of french polishing over a coat of wood filler on new works complete all as specified and directed.
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps, Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed.
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment. (Fe 410 -W (Gde- E-250) quality -A complete all as specified and as directed.
S & F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Supply, installing, testing and commissioning of wall mounted split type AC of capacity 1.5 TR, (indoor/outdoor unit complete) with 5 star rating and EER 3.2, inverter technology and cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality complete all as per specified and directed
Note for Item No 85:- Copper tube, insulation materials, clamps, out door unit stand and water pipe from condenser unit etc as required shall be arranged by the contractor and cost for the same is deemed to be inclusive in this item.
Supply and fixing and testing of 4 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as per manufacturers instructions and directed by Engineer-in-Charge.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size non metallic PVC conduit / casing capping and all accessories fixed to wall / floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 88:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit/ casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply & fix industrial type metal clad plug top & socket single pole and a neutral link earth enclosure with one MCB SP 32 Amp complete all as specified and directed
Supply & fix single pole MCB 10 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified and directed.
S & F Digital 2 AC wall mounting type cyclic timer for automatic change over with two heavy duty 30 Amp relay output capable to take load of AC-1 and AC-2 up to 2 Tons complete with following technical specification as per manufacturers instructions and directed by Engineer-in-Charge.
Note for Item No 93 :- (i) Operating Voltage Range :- 90 V to 440 V AC, 50 Hz
(ii) Maximum contact rating :- 30 A @ Unity PF
(iii) Technology :- Advanced Micro - Controller with Memory Backup
(iv) Mounting :- Wall or board mountable
(v) Display :- 16 Characters x 2 lines Multi- info LCD with Back-light
(vi) Setting :- Simple 3 buttons to set AC-1, AC-2 ON and OFF Times independently
(vii) Modes :- Auto & Manual Modes
(viii) Memory Backup :- Up to 7 Years for the setting done for AC-1 & AC-2 by way of replicable coin cell
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achieve earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanently welded to the copper bounded rod to avoid any kind of connectivity loss. The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (cost for copper strip up to 7.5m is deemed to be inclusive in quoted rate). Any additional requirement will be paid and measured separately under relevant item here-in-below
(xv) The acceptable earth resistance at earth bus bar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
S & F Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed.
Note for Item No 121 :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed.
S & F copper strips of size 50mm x 5 mm as earthing lead from antistatic flooring to earth pit including exothermic welding in all joints complete all as specified and directed
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through stove enamelled steel conduit fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly complete all as specified and directed for the following:-
one light point/fan point controlled by one switch
All as per item No. 125 here in before but for One 3 pin socket outlet 5 Amp on the independent board
All as per Sl No 125 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket outlet independently
S & F modular switch 1 way 6 amp.1 module complete all as specified and directed.
Supply and fixing switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed
Supply and fix modular socket 6 A, 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix modular switch 1 way 16A, 1 module complete all as specified and as directed.
Supply and fix modular metal flush box 3 module complete all as specified and as directed.
Supply and fix modular white cover plate 3 module complete all as specified and as directed.
Supply and fix modular metal flush box 2 module complete all as specified and as directed.
Supply and fix modular white cover plate 2 module complete all as specified and as directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and including 32 mm steel conduit and all accessories fixed to wall / floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 138:- (a) 4 runs of 4 sqmm cable along with 2 run of 4 sqmm cable for earth conductor and 32 mm steel conduit shall be measured as one length.
S&F factory made powder coated distribution board SPN, 4 way single door including 200 Amp rated bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
Supply & fix single pole MCB 6 to 32 amp, 240 v, 50 Hz AC suitable for ‘B’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix single pole neutral, MCB 32 amp, 240 v, 50 Hz AC suitable for ‘B’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply and fixing LED light fitting 1X30watt flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all specified and as directed.
Taking down aluminum point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid separately) and making good the disturbed plaster surfaces of wall, floor, ceiling complete all as specified and directed.
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing and capping fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly complete all as specified and as directed for the followings complete all as specified and directed.
One light point/fan/bell point controlled by one switch
All as per item No. 145 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 145 above but Wiring with 4 Sqmm copper multi-stranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix in repair modular switch 1 way 6 amp.1 module complete all as specified and directed.
Supply and Fix in repair modular switch 1 way 16 amp.1 module complete all as specified and directed.
Supply & fix in repair modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix in repair modular Socket, 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply & fix in repair modular white cover plate with frame, 3 module complete all as specified and directed.
Supply & fix in repair modular white cover plate with frame, 6 module complete all as specified and directed.
Supply & fix in repair modular white cover plate with frame, 8 module complete all as specified and directed.
Supply & fix in repair modular Metal flush box, 3 module complete all as specified and directed.
Supply & fix in repair modular Metal flush box, 6 module complete all as specified and directed.
Supply & fix in repair modular Metal flush box, 8 module complete all as specified and directed.
Supply & fix in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
Supply & fix in repairs ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified and directed.
Supply and fixing in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in repairs round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed.
S & F in repairs LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in repairs LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F in repairs factory made powder coated distribution board SPN, 12 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
Supply & fix in repairs single pole neutral, MCB 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix in repairs single pole MCB 10 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified and directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including PVC casinng and capping of suitable size and all accessories fixed to wall / floors along with 1 run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly Including taking down existing submain wiring complete all as specified and as directed.
Note for Item No 168:- (a) 2 runs of 6 sqmm cable along with 1 run of 6 sqmm cable for earth conductor and PVC casing and capping shall be measured as one length.
M & L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised iron earth wire 4mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 15mm bore (dia) medium grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6, type C-1 using 20mm graded stone aggregate and Pre-cast RCC Cover Slab of size 300x300x40 mm in Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, returning, filling in and removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on Completion including taking down old unserviceable one, complete all as per specified and directed.
Note for Item No 170:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone without extra cost to Govt till desired result is obtained.
M & L sand filling under floors or in foundations including watering and consolidation completa all as specified and directed.
M SUNDARARAJAN
NAVEEN ENTERPRISES
CAK Enterprises
S KUMARAN
Neptune Engineers and Builders
M/s.Sai Agency
D.R ASSOCIATES
KUMAR AGENCIES
N SARAVANAN
T C KARUNANITHI
NLK Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .