Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.4 L+₹2.5 L (8.75%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹31.6 L+₹2.7 L (9.30%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹32.0 L+₹3.1 L (10.6%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹34.6 L+₹5.7 L (19.8%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
15 Jun 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPECIAL REPAIR/REPLACEMENT OF OVER HEAD LINE TO UNDERGROUND CABLE AT CCSR IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2022_MES_525267_1
GE/EM/LKO/EXT(ELECT)/T-31 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹76,000
Yes
2 Sept 2022
20 May 2022
17 Jun 2022
20 May 2022
15 Jun 2022
3 Jun 2022
Amount
Taking down existing ACSR conductor including disconnection after taking proper written shut down from HT/ LT OH line complete all as specified and directed.
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed.
Dismantling of GI wire any type and any size complete all as specified and directed.
Dismantling of existing LT/HT insulators any types and any size complete all as specified and directed.
Excavation in trenches in soft/Loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for fly ash bricks, old size as per IS 1489 (Part I)-2002 laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
Supply, laying jointing and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. Note- Excation, earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under given items.
All as per item No 11 above but size 35 sq mm 3.5 core
All as per item No 11 above but size 95 sq mm 3.5 core
All as per item No 11 above but size 70 sq mm 3.5 core
All as per item No 11 above but size 50 sq mm 3.5 core
All as per item No 11 above but size 16 sq mm 4 core
All as per item No 11 above but size 10 sq mm 2 core
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 6 Sqmm 2 core nominal cross section complete all as specified and directed.
M&L Earth continuity conductor or main earthing lead laying to treanches & fixed to pole 4 mm dia galvanised iron wire, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor, complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
Supply and laying in trenches/Floor/road crossing or fixed to Pole/Wall GI pipe light grade ISI marked with fitting of size 100 mm bore for protection of cable including taking down existing pipe complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
S&F in replacement wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion, complete all as specified and directed.
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated Timer panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40x40x6mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50x50x6mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated LT Panel board(Dimention of Cubical/enclosure not less than 1400mmx1200mmx500mm) ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) MCCB 4 pole , 4000 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 02 Nos (ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks, rendering 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
All as per item No 30 above but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) Isolator four pole 240/415 V , 100 Amps - 05 Nos
M&L in replacement out door type busbar panel board (Dimention of Cubical/enclosure not less than 600mmx450mmx450mm) made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs complete all as specified and directed.
Unnati Engineers
Eco Creations
BHATIA ENTERPRISES
U K Enterprises
M/S Nav Jyoti Enterprises
Diamond Electric Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .