Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDER | |
| 2 | L2₹21.4 L+₹43,588 (2.08%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹23.4 L+₹2.5 L (11.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹23.4 L+₹2.5 L (11.8%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹24.8 L+₹3.8 L (18.3%)Rejected-Finance 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Mar 2020, 6:00 pmClosed
SH M V SANKAR SE CWE
CWE NAVY VASCO
RENEWAL OF OLD LIGHTS AND FITTINGS INTO ENERGY EFFICIENT LED LIGHT AND FITTINGS AT NIH GOA UNDER GE GOMANTAK VASCO
2020_MES_329760_1
85238/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK
₹70,000
Yes
13 May 2020
28 Feb 2020
23 Mar 2020
28 Feb 2020
20 Mar 2020
13 Mar 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc complete all as specified and as directed.
Material and labour for point wiring complete as specified with 1100 V grade 1.5 Sq mm single core PVC insulated unsheathed multi stranded copper conductor cable FRLS grade, conforming to relevant IS, drawn through and including PVC casing and capping of suitable size with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls for housing switches, socket, regulator etc including 1.5 sq mm single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing for ceiling fan, wall mounted fan, tube light complete all as specified and as directed for the following.
All as per serial Item No 2 here in before but for one 5 pin switch socket outlet 5 Amps on independent board controlled by one switch all as specified and as directed.
All as per Item No 2 here in before but for one 6 pin socket outlet 15 Amps independent/metal plug and socket with cables 4 sq mm size copper PVC insulated cable multi stranded and 4 sq mm cable conductor for earth wire all as specified and as directed.
S&F Modular switch one way 6 Amp 1 module all as specified and as directed.
S&F Modular switch one way 16 Amp 1 module all as specified and as directed.
S&F Modular socket , 6 A -2/3 pin combined 2 module all as specified and as directed.
S&F Modular socket , 15 A -2/3 pin combined 2 module all as specified and as directed.
S&F Modular white cover plate with frame ,1/2 module all as specified and as directed.
S&F Modular white cover plate with frame ,3 module all as specified and as directed.
S&F Modular white cover plate with frame ,4 module all as specified and as directed.
S&F Modular white cover plate with frame ,6 module all as specified and as directed.
S&F Modular white cover plate with frame ,8 module all as specified and as directed.
S&F Metal flush box 1/2 module all as specified and as directed.
S&F Metal flush box 3 module all as specified and as directed.
S&F Metal flush box 4 module all as specified and as directed.
S&F Metal flush box 6 module all as specified and as directed.
S&F Metal flush box 8 module all as specified and as directed.
S&F in repairs batten 24W, 4 ft LED fitting , complete etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
S&F in repairs 36W Recess mounting fully diffused LED Luminiare (595X595mm) , complete etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
M&L for sub main wiring with 10 sq mm 4 Runs of single core multi stranded PVC FR LS insulated unsheathed cable 1100 Volts with copper conductor drawn in and including PVC Casing and capping with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 10 sq mm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to existing main switch board \ Distribution Board and testing on completion including taking down old sub main wiring and type of conduct complete all as specified and as directed. Note: Five runs of 10 sq mm and one run of PVC casing and capping shall be measured as one unit length.
M&L for sub main wiring with 6 sq mm 4 Runs of single core multi stranded PVC FR LS insulated unsheathed cable 1100 Volts with copper conductor drawn in and including PVC Casing and capping with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 6 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to existing main switch board \ Distribution Board and testing on completion including taking down old sub main wiring and type of conduct complete all as specified and as directed. Note: Five runs of 6 sq mm and one run of PVC casing and capping shall be measured as one unit length.
M&L for sub main wiring with 4 sq mm 2 Runs of single core multi stranded PVC FR LS in related unsheathed cable 1100 Volts with copper conductor drawn in and including PVC Casing and capping with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 4 sq mm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to existing main switch board \ Distribution Board and testing on completion including taking down old sub main wiring and type of conduct complete all as directed. Note: Three runs of 4 sq mm and one run of PVC casing and capping shall be measured as one unit length.
M&L for sub main wiring 2 runs of 6 sq mm PVC FR LS insulated, unsheathed, single core, multi stranded, 1100 volts copper conductor cable and one run of 6 sq mm PVC insulated, unsheathed, single core, multi stranded copper conductor cable through PVC Casing & Capping including all accessories all as specified and as directed. Note : Three runs of 6 Sq mm cable and 1 run of PVC Casing & Caping wide shall be measured as single run.
M&L for sub main wiring 2 runs of 10 sq mm PVC insulated, unsheathed, single core, multi stranded, 1100 volts copper conductor cable and one run of 10 sq mm PVC insulated, unsheathed, single core, multi stranded copper conductor cable through PVC Conduit including all accessories all as specified and as directed. Note : Three runs of 10 Sqmm cable and 1 run of PVC Casing & Capping wide shall be measured as one unit length.
M&L for submain wiring with 1.5 sq mm 2 Runs of single core multi stranded PVC FR LS in related unsheathed cable 1100 Volts with copper conductor drawn in and including 25 mm wide PVC Casing and Capping with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 1.5 sq mm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to Existing main switch board \ Distribution Board and testing on completion including taking down old sub main wiring and type of conduct complete all as specified and as directed. Note : Three runs of 1.5 Sq mm cable and 1 run of PVC Casing & Capping wide shall be measured as one unit length.
S&F MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA all as specified and as directed.
S&F MCB, single pole and neutral, 6-32 Amp, 240 Volts, 'C' Curve 10 KA all as specified and as directed.
S&F MCB, Triple pole and neutral , 63 Amp, 415 Volts, 'C' series 10 KA all as specified and as directed.
S&F Sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door with 100 Amp rated Copper bus bar with IP 54- IK 09 complete all as specified and as directed. Note:- Empty space will be fixed with blanking plate and the rate of blanking plate is deemed to be included in the quoted rates
S&F Sheet metal enclosure (VTPN DB) for MCCBs, 100A 4 way, triple pole and neutral, 415 Volts, double door with Copper bus bar with IP 54- IK 09 Complete all as specified and as directed. Note:- Empty space will be fixed with blanking plate and the rate of blanking plate is deemed to be included in the quoted rates
Supply and fix sheet metal enclosure (VTPN DB) for MCCBs, 250A 4 way, triple pole and neutral, 415 Volts, double door (Metal door) with Copper bus bar with IP 43- IK 09 Complete all as specified and as directed. Note:- Empty space will be fixed with blanking plate and the rate of blanking plate is deemed to be included in the quoted rates
S&F in repairs MCCB 415V, 3 phase 50 HZ FP 100 Amps breaking capacity 10KA all as specified and as directed. Note :- MCCB Should be suitable for accommodating in VTPN DB
S&F in repair MCCB 415V, 3 phase 50 HZ FP 250 Amps breaking capacity 10KA all as specified and as directed Note :- MCCB Should be suitable for accommodating in VTPN DB
S & F in Ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
M&L for earthing complete with copper plate earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top connected to Copper earth strip 20 x 3mm by means of bolts, nuts, check nuts and washers of brass and earth lead connected to main DB panel /meter box panel with including necessary and earth work and excavation including PCC chamber 1:3:6 and RCC cover all as specified and or shown in electric plate No 3 of SSR-1 all as specified and as directed.
S&F in repairs modular fan regulater electronic step type 120 W-2 module all as specified and as directed.
S & F in repairs LED Street light 60W high grade pressure die cast aluminium housing street light luminaries with IP66 including suitable size of GI pipe 1.2 m long bet to required shape making electrical connection to the fitting with suitable size of service wire including GI elbow with proper clamp nut & bolt all as specified and as directed.
S&F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 16/20 Amps, 240 Volts complete all as specified and as directed.
M/S SURINDER KUMAR MAHAJAN
BROTECH
SLB Enterprises
SURAT SINGH AND SONS
N K CONSTRUCTION
NATIONAL ENGINEERING CORPORATION
M/s VEEJEE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .