Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-Finance | L1 | Accepted-Finance Being lowest bidder | |
| 2 | L2₹9.4 L+₹48,780 (5.45%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.6 L+₹1.7 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Adverse remarks in Work load return |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
18 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-55/2021-22 REPAIR/MAINTENANCE OF EXTERNAL/INTERNAL ELECTRIC SUPPLY AT AF STN KALUCHAK UNDER GE(AF) JAMMU
2022_MES_514592_1
CA NO GE/AFJ-55/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹21,000
Yes
4 Jun 2022
21 Mar 2022
20 Apr 2022
21 Mar 2022
18 Apr 2022
4 Apr 2022
60 days
Amount
M & L for Servicing of DG sets of capacity 75 kVA to 200 kVA including carrying out maintenance and check alongwith following repairs :- (i) Drain out the lubricating oil from sump and refilling after proper cleaning. (ii)Replace Engine Oil filter cartridge with New one. (iii)Replace fuel filter cartridge with New one. (iv)Check tightness of all nuts and bolts. (v) Check adjustment of V belt for driving engine water pump and alternator. (v) Cleaning of fuel tank as required (vi) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engineer-in-Charge. (vii)Testing of DG set after servicing as per Engineer-in-Charge. (viii) Cleaning of air cleaner filter and renew after period two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servecing where require time to time and for which no extra payment shall be permitted. (ix) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Note:-(i) Any minor parts such as screws, washers , split pin , circlip, cotton waste, etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii)The Job shall be carried out after two hundred hrs run of DG Set or as recommended by Engineer-in-Charge and contractor shall be responsible to carry out the maint/servicing where require time to time and for which no extra payment shall be permitted. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Supply Only the following parts suitable for 75 KVA to 200 KVA DG sets: -
Oil filter Cartridge Make: Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Fuel filter Cartridge pre and fine both as required. Kirloskar/Greaves/Cummins/Ruston/Micco/Fleet Guard
Air cleaner filter Cartridge, Make: Kirloskar/Greaves/ Cummins/Ruston/Micco/Fleet Guard
Radiator hose pipe, Make: Kirloskar/ Greaves/ Cummins/ Ruston
Fan belt complete for DG set. Make- Kirloskar/ Greaves/Cummins/Ruston/Fenner
Turbo oil pipe, Make: Kirloskar/ Greaves/Cummins/ Ruston
Fuel pipe heavy duty, Make: Kirloskar/Greaves/ Cummins/ Ruston
Battery terminal of brass heavy duty type as per existing sample
Solenoid Switch, Make: Kirloskar/ Greaves/TVS Lucas
Oil drain pipe heavy duty, Make: Kirloskar/ Greaves/Cummins/ Ruston
Water pump assy, Make: Kirloskar/ Greaves/Cummins/ Ruston
Self startor assy 24 volts, Make: Kirloskar/Greaves/TVS Lucas/Autolek
Copper battery lead 3 mtr long 16mm dia multi stranded, Make: Kirloskar/ Greaves/Cummins/ Ruston
DG set rubber coupling for 75/200 KVA, Make: Kirloskar/Greaves/ Cummins/Dunlop
Supply only distilled water, Make: As per the recommendation of Exide/Kochar/Amron
Supply only Coolant Make- Castrol or As per the recommendation of Kirloskar/Greaves/Cummins
Supply only Turbo lubricant oil 15W-40 Make: Castrol or as per the recommendation of Kirloskar/Greaves/ Cummins
Repair/servicing Self startor 12 volts incl replacement of wornout part such as carbon brush, bentex pinion, bushes, carbon brush holder, solinoid and refixng complete set to work of 75 KVA DG sets
Supply and fixing in repairs lead acid battery 12 Volts, 180 Ah Make-Exide/ Amaron/Tata in approved make all as directed by Engineer-in-Charge
M& L for removing bore well column pipes upto 100mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY of capacity 12.5 Hp, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling into the bore well all as specified and as directed.
M&L for disconnecting and removing the PUMP SET from its foundations/ base frame located at different locations, by disconnecting suction, delivery pipes, pump couplers and electrical connections, taking it to workshop for repair, dismantling and opening up of PUMP assembly complete, removing worn out Gland, bush, shafts, pump Housing, bearing, Gland Packing, Pin locking set, nuts and bolts, washers etc., and replacing with new parts of same make/model/type including necessary machining works as required, assembling, Balancing and refixing the pump back to its postion after getting repair and making all connections, carry out alignment, and testing for satisfactory function all as specified and as directed for centrifugal pump set of capacity 7.5Hp
Material and Labour for disconnecting and removing the MOTOR of any make/model / type, from pump sets and foundations/ base frame located at different pump houses, by disconnecting electrical connections and pump couplers, taking it to workshop for repair, dismantling stator and rotor assembly, removing burnt out winding wires complete, rewinding the stator with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding, drying up by heating , assembling back the stator and rotor including replacement of nuts, bolts, studs, Gasket, packing, locking pin, terminal blocks, and terminal bolts and nuts and misc accessories & hardware required for making motor functional, both end bearings (labour only) with same size/make complete for 3Ph, 415V, 7.5Hp motors all as specified and as directed. Note: 1. Bearing shall be measured and paid separately.
Supply and fixing antifriction heavy duty ball bearings suitable for 7.5Hp pump/Motor
Taking down old u/s starter and Supply and install star delta starter in sheet steel enclosure with single phase protection feature suitable for operation on AC, Three phase , 415 Volts, 50 Hz supply for Motor of capacity up to 10HP with relay range 9-15Amps complete Make: L&T / SIMENS/HAVELLS
S & F illuminated Push Button Projecting Head complete all as specified and directed in RED/GREEN in color, 240V AC, Cat No EG03PDL, Make: L&T/HPL with taking down old u/s push button of any type
S & F LED Indication lamp for LT Panel board RED/YELLO/BLUE, Surface Mounted Device LED technology Low Power consumption < 0.6W Low Voltage Glow Protection (LVGP) Cat No: SIL 240A-240V AC including taking down old u/s phase indication lamp Make: L&T or HPL/Havells
Supply, laying, connecting and testing Submersible flat cable 3 core 10 Sqmm PVC insulated and PVC sheatehed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
Supply and fix cam operated rotary switches 32A with 90⁰ ON-OFF operation and complete rotation of type . Cat No.61197 of Make: L&T or equivalent of Siemens/Standard
M&L for Painting of pump sets & motor assembly of capacity 5Hp to 15Hp located at various installations comprising electric Motor , pump , base frame, suction and delivery pipe lines inside & outside of pump house, valves any type and size up to 100 mm dia withTwo coat of synthetic enamel paint of approved colour including scrubbing / cleaning all metalic surfaces before painting and writing SM/MES No. etc, all as specified and as directed.
M & L for Painting with two coat of synthetic enamel paint for pipes any description, n. exc 60 cm girth including holder bats, distance pieces, etc. (length measured over bends, branches etc.)
Excavation in trenches in exc 1.5 m width and n. exc 1.5 m depth and getting out in Hard/Dense soil for laying of water pipe line etc. complete all as specified and as directed
Returning, filling in (Soils) including spreading levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated material (soil) n. exc 50 metre and depositing where directed at a level n. exc 1.5 metre above the starting point complete all as specified and as directed by Engr-in- charge
Supply and laying in trenches Galvanised steel (Gl) tubing 'Medium grade' with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) with cutting, screwing, making forged bends on piping as required. insertion of Connectors where required or directed. including cutting through walls, floors, etc. and their making good all as specified and as directed for including taking down old u/s pipe for following size of pipes : (Note : Earthwork shall be measured and paid saperately under relavent Item)
15mm bore dia
20mm bore dia
25mm bore dia
40mm bore dia
50mm bore dia
Taking down carefully unsv copper/aluminium point wiring light/fan/socket or power complete and including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site
Material and labour for point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated unsheathed cable with proper colour coding drawn in existing conduit and FRLS PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 cm deep & 2.8 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following.
(a) One light /fan/ call bell point controlled by one switch
(b) One 3/5 pin socket outlet 5 amp controlled by one 5 amp switch on the independent board
(c) One 3/5 pin socket outlet 5 Amps on same board controlled by one 5 amp switch
NOTE for Item 23:- 1. Wiring shall be done by contractor with colour coding. 2. Earth wire shall be in green colour. 3. wiring shall be carried out under repair work against the complaints received from the users and no bulk site will be handed over to the contractor.
All as per item No 23.00 here-in-before but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board for 15A socket point.
Supply and fixing PVC concealed conduit not less than 20mm dia will all accessories complete all as specified and as direced by Engineeer-in-Charge NOTE: Cutting chases in wall for removing old conduit shall be approved & have to shown to the Engr-in-Charge by the contractor before laying new conduit and wiring. 2
Supply and fixing LED slim ceiling light fitting with extruded aliminium housing and milky diffuser 36 W 2'x2' slim panel, 610x610 mm recess/surface/ suspended mounting and testing complete including dismantling and taking down old fitting of any type all as specified and as directed by Engr-in-charge Cat part No- LTCRSLM36WATT2X2 of C&S/Havells/Crompton
Supply and fixing Switch piano flush type single pole one way 5 Amps complete
Supply and fixing Bell push piano flush button single pole one way 5 Amps complete
Supply and fixing Ding-dong type electric belll AC 230 Volts single pole complete of make Anchor/Philips
Supply and fixing Switch, socket combination outlet multipurpose, 2 in 1, 3 pin, 5 Amp flush type complete
Supply and fixing Switch socket combination multipurpose 3 pin 5 Amp and 15 Amps, flush type complete
Supply and fixing Socket outlet multipurpose 2 in 1, 3 pin, 5 Amp flush type complete
Supply and fixing Socket outlet multipurpose 2 in 1, 3 pin, 5 pin and 15 Amps, flush type complete
Supply and fixing Stepped type electronic fan regulator flush type
Supply and fixing Ceiling roses 3 phase /PVC/ Polycarbonate isolated body
Supply and fixing Indoor decoraticve LED Battens -T8 tube light fitting 20 W,4 fit long white with PVC extruded batten complete in all respect incliding 20 W retrofit tube and taking out old complete all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTDCO1220E LED/WD of C&S or equal approved in Philips/Bajaj/ Havells/Crompton
S&F DB SPN 2 Way 240 volts single door, Make:- Legrand (DX³) or equal approved in Siemens (8GB32)/Schneider (Acti 9)
S&F DB SPN 8 Way 240 volts double door with 200 amps rated bus bar. rated bus bar, SPN, Make: Legrand (DX³) / Siemens (8GB32)/Schneider (Acti 9)
Supply and fix Cable 1100 volts grade heavy duty 10 sq mm flat/round twin core cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed taking out old for service connection complete all as specified and directed by the Engineer-in-charge.
Supply and fix, taking down old MCB TPN 415 Volts, C curve, 40 to 100 Amps, 10 kA, Make: Legrand (DX³)/Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fixing, taking down old MCB 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning, Make: Legrand (DX³) / Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fixing, taking down old MCB 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 to 63 AMP, in the MCB DB Complete with connection testing and commissioning, Make: Legrand (DX³) / Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fixing, taking down old MCB 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, Make: Legrand (DX³) / Siemens (Betagard-5SL4)/Schneider (Acti 9)
Supply and fixing ISI mark aluminium thimbles suitable for under ground LT cables of sizes 16 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesary earth work and reconnecting the same.
Supply and fixing ISI mark aluminium thimbles suitable for under ground LT cables of sizes 25 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesary earth work and reconnecting the same.
Supply and fixing ISI mark aluminium thimbles suitable for under ground LT cables of sizes 185 Sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesary earth work and reconnecting the same.
Supply and fixing Tinned copper fuse wire rating 20 Amp as per sample approved by Engr-in-charge.
Supply and fix, taking down old Indus series Powder coated pressure die cast aliminium compact high power LED street light fittings with heat resistant toughned glass with lens having 45 Watt with lens complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTESS 18x2.5 HP LED/LS of C&S or equal approved in Philips /Bajaj/ Havells
Supply and fix, taking down old High power LED flood lights fittings with pressure die cast aluinuim housing complete with all accessoies IP 65,120 watt , complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make: Cat part No- LTEFI120WHPLED of C&S or equal approved in Philips /Bajaj/ Havells
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 100 amps having breaking capacity of 36 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make - Cat part No 420095 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 200 amps having breaking capacity of 36 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make -Cat part No 420248 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old ISI mark MCCB 4 pole, 415 volts, thermal release range 250 amps having breaking capacity of 50 kA complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make -Cat part No 420279 of Legrand (DPX³) or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply and fix, taking down old UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make- Gloster/polycab/Havells
Supply and fix, taking down old UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 2 core complete fixed in repairs all as specified and directed by Engineer-in-Charge. Make- Gloster/polycab/Havells
Material and labour for maint/repair of existing feeder pillar Box/LT Panel, bus bar, hinge, handle, locking arrangment, foundation, thimble, loose connection including welding to door ,legs,back door etc,complete all as specified and directed by Engineer-in-Charge
Material and labour for repair to existing LED street light 30/ 45 watt of any make including replacement of driver, LED strips and other allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge
Repair/maintenacne of lifts including carrying out periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen
button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, including repair/maint of motor, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 8Passanger Lift operating for G+4 floors at SRE Bldg 23Wing AF Jammu
Note :- (a) The above service shall be made on monthly basis and as and when any breakdown arise (b) The Contractor shall be porvide authorised service personnel of Johnson company as and when required in case of any emergency occured at any time included odd hrs/sunday/Holiday and cost to this effect shall be deemed to included in quoted rates. (e) The Contractor shall visit the site before quoting the tender.
Supply only the following item of lift for making the lift serviceable completely to the entire satisfaction of the Engineer-in-Charge (Note: The fixing of these items including taking out unserviceable items shall be measured under ser item No 56.00 here-in-before): -
Car light fittings (as per sample), Make: Havells/Bajaj/C&S
Car push button (ISI Marked) (as per sample)
Back up batteries 12V 18 AH connecting terminals and copper leads for proper connecting of set of battries, maintenance free batrries complete and suitable for lift, Make:Amron/Exide
Cutting wild grasses,bushes,creepers,unwanted vegetations, etc. from surrounding power house/pump house/transfarmer/poles/stays including cleaning cripper climbed on poles as and when directed and removing the spoil and deposit where directed (size of cutting 90x90 cm around pole/stay) entire satisfaction of Engnr-in-Charge complete all as specified and directed .
Material and labour for carrying out annual maintenance of UV based water purifier make Livpure/ Aquafit by replacement of pre filter candle sleek and carbon block twice in a year and servicing twice after regular intervals, including the replacement of circuit board and any other part as required at site to make the Livpure/ Aquafit functional throughout the year.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 32 x 6 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following:(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) HDPE/FRP earth pit cover square type of size internal size not less than 300x300mm with top openable cover with handle and one side hinges (.d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. ( f) Requisite quantity of common salt and charcoal.(g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing. (c) GI Strip Beyond 7.5 Mtr Will be Measured and Paid for Separately
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S ASHOK KUMAR SURI
VIDHATA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .