Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC VILL BATABARI PO DALGAON PS DALGAON DARRANG ASSAM 784116 | DARRANG | ASSAM | 784116 | ₹2.5 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | L2₹2.7 Cr+₹15.6 L (6.15%)Rejected-Finance 304 | DHANBAD | JHARKHAND | 818142 | ₹2.7 Cr+₹15.6 L (6.15%) | L2 | Rejected-Finance Rejected as L2 |
| 3 | L3₹2.9 Cr+₹33.8 L (13.3%)Rejected-Finance HARI HAR ENCLAVE 3RD FLOOR CHRISTIAN BASTI G S ROAD GUWAHATI 781005 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781005 | ₹2.9 Cr+₹33.8 L (13.3%) | L3 | Rejected-Finance Rejected as L3 |
| 4 | L4₹3.0 Cr+₹41.3 L (16.2%)Rejected-Finance | ₹3.0 Cr+₹41.3 L (16.2%) | L4 | Rejected-Finance Rejected as L4 |
| 5 | Rejected-Technical VILL DONGARKUCHI P O SONKUCHI P S BARPETA DIST BARPETA ASSAM 781301 | BARPETA | ASSAM | 781301 | - | - | Rejected-Technical As per decision of Bid Evaluation Committee |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
14 Jul 2022, 2:00 pmClosed
Chief Engineer,(EAP) PWRD,Assam
O/o The Chief Engineer,(EAP) PWRD,Assam Fatasil Ambari,Guwahati- 781025
APART/NOCP/WAREHOUSES/DNG-05 Renovation and Up-gradation of Warehousing Facilities in existing Warehouse complex at Kharupetia (Godown 5) in Darrang District under APART.
2022_PWRDW_25964_5
CE/APART/135/2022/8
Open Tender
Civil Works - Building
Lump-sum
270 days
Darrang District
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,000
₹6.0 L
Yes
O/o The Chief Engineer,(EAP) PWRD,Assam
16 Nov 2022
14 Jun 2022
14 Jul 2022
14 Jun 2022
14 Jul 2022
14 Jun 2022
14 Jun 2022 - 24 Jun 2022
24 Jun 2022
Amount
CIVIL WORKS Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kind of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
GRANULAR SUB-BASES, BASES (NON-BITUMINOUS) AND SHOULDERS Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
Water Bound Macadam Sub-base/base Grading- III (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km.)
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification and as directed. 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
ANTI - TERMITE TREATMENT Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundation, footings, bases of columns
Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc..
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
RANDOM RUBBLE MASONRY Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (c).Stone soling of thickness 150mm.
FLOORING Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
ROOFING Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Ridges plain (500 - 600mm).
Barge board (Upto 300 mm).
Crimp curve
Extra for crimp at eave of colour coated zinc-aluminium roof , wall and tile profile sheet accessories (total coating thickness=0.5mm) including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) Crimped Eave
FINISHES 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
PLASTER OF PARIS & WALL PUTTY Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
PAINTING ON STEEL AND OTHER METAL SURFACE Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
PAINTING ON STEEL AND OTHER METAL SURFACE Painting with aluminium paint of approved brand and manufacture to give an even shade :
Steel Work: Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete . PL 16MM thick
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
ROOF TRUSS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.
COLLAPSIBLE / ROLLING SHUTTERS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete 20mm dia (1000 mm long)
Providing and fixing bolts including nuts and washers complete. 20 mm dia (600 mm long)
PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
DISMANTLING AND DEMOLISHING Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge
Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. (i) Area of door/window up to 3.00 m2
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
Soling Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Edge Soiling
PLINTH PROTECTION DRAIN Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soiling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
RETRO FITTING WORKS Chippng and breaking/cutting of loose concreate , motars etc.using Electrical chipping hammers to the satishfaction of the engineer-in -chargefor succesful execution of thr subsequent rehabitation works all heights with all leads , lift etc . Complete ith all tools and machineries required for the job ,operator, applicator ,labour, scaffolding for staging and supervision etc. Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/Choskey
Poviding and applying two coats of two component epoxy zinc rich primer like Fosroc Nitozinc Primer or equivalent on the properly cleaned reinforcement after the required chipping and cleaning of the concreate surface as per the manufacyure’s specification at a dry flim thickness of 40 micron /coat.The epoxy zinc rich primer should have a adhesive bond strength with steel greater than 1.5 N/Sqm.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and applying Providing and applying structural grade long pot life epoxy bonding agent of like Nitobond EP or equivalant prior to building up of section with any type of mortar/ concrete to ensure bond between old concrete & new concrete by brush application as per the manufacturer’s specifications.The bonding agent should remain in tacky state after application for a minimum period of 6 hours at 30 ºC. There shall not be bond failure of the specimenwhen tested by slant shear method according to BS 6319 pt 4, with concrete.
Providing and placing free flow micro concrete of approved brand after fixing slurry tight shuttering. The microconcrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state.The micro concrete in the flowable consistency should achieve a compressive strength of not less than 10N/mm2 after 24 hours, 40N/mm2 after 7 days and 50 N/mm2 after 28 days at 30ºC. Most importantly, the cured microconcrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The unrestrained expansion shall be between 1 - 4%. The flexural strength shall not be less than 5 N/mm2 @ 28 days. The microconcrete shall have a coefficient of thermal expansion similar to that of the host concrete. The mixed density of microconcrete shall exceed 2100 kg/ m3 at 27ºC.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and Sealing the cracks, in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non- sag, epoxy compound like Nitobond PC40 or equivalent inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two- component, high strength, low viscous epoxy resin system grout like Conbextra EP10 or equivalent.(inclusive of Manpower, Material and Equipment). Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Drilling 12 mm dia X100 mm hole in to the concreate surface using concreate hammer drill machine. Providing 10mm PGMs nozzles is gird of 0.25 m both and injecting cement slurry Injecting cement slurry 1:3 ( 1 Cement: 3 water ) by weight including mixing of grout compound as per manufacture specifications , in cracks/ effected approved brand till completion and refusel of gout complite as per manufactures specification. The nozzles are to be sealed off after grouting using rapid setting cement based pluging mortar of approved brand.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Crack opening should be chiselled out to approximately 20mm X 20mm , and should always be undercut to avoid formation of a V shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Single part, non shrink, cementitious, crack sealer like Fosroc Renderoc CS or equivalant for plaster, masonry and concrete as per manufactures specificationMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and Applying a two component structural grade polymer modified reinstatement mortar of approved brand up to a thickness of 10 mm over a epoxy rasin bonding agent like Fosroc Renderoc S2 or equivalent. The cured mortar shall achieve a compressive strength of 12 N/mm² in 1 day & 45 N/mm² in 28 days with Flexural strength 8 N/mm² in 28 days. Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated Electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. In addition to this percentage of water absorption should be 0.45 after 24 Hrs in immersion testMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
TURBO VENTILATOR Supplying, fitting and fixing in position turbo ventilator of Nylon made Typhonic Bearing, double top cap ensured permanent alignment in inverted cap design, corrugated foil framed of aluminium fabrication for wind driven having wind velocity 1600 exauster of effective throatal Dia 21 inch and overall dia 28 inch having overall height 17 inch as specified and directed by the Engineer-in-charge.
LOUVERS Providing & fixing louvers of size (450mmx300mm) at all heights with all leads- 3.5 mm thick toughened frosted glass louvers, 25 micron anodized aluminum sections for louver manufactured from best extruded aluminum sections from approved manufactures, the frame work fixed of jindal sections of minimum anodic coating of grade AC 15 with standard approved fastenings or hinges as per details specifications with all the sections pretreated for removal of any rust and prevention of any further rust, M.S. Grill of required size, one primary coat of red-lead/red oxide primer and two coats of enamel paint of approved brand and manufacture all complete as per specifications and direction by the Engineer-in-charge.
VDF Providing VDF flooring for top coat of floor with dewatering of concrete by vaccum pump and sprinkling non-metallic floor hardner @ 5 kg/sqm followed by a coat of cement slurry mixed with Nitobond SBR latex or equivalent @ 1 kg over 1.25 sqmtr and 67 ml. Nitobond SBR latex. Over the levelling reinforeced cement concrete base 1:1.5:3 simulteniously casted as per specification. 10mm x 12mm groove @ 5 mtr. or equally distributed pattern to be cut and filled with Polysulphide Sealent as grouting compound. Complete and finished in all respect as per company specification and Engineer-in-charge. (The R.C.C. work will be measured and paid separetly)
CEMENT PLASTERING WITH CHICKEN MESH AND CHEMICAL Repairing brick wall with cement concrete ( 1:2:4 ) of thickness varing from 25mm to 100 mm after cleaning of the surface of the brick wall applying bonding agent Nitobond EP Std./Sikadur-32 LP or equivalent product to cover up the damaged portion of existing brick wall including fixing of chicken wire netin position to hold the c.concrete if necessary. Finished and complete as per direction of Engineer in Charge.
GROOVE CUTTING AND FILLING IN WALL Cutting of groove size 10mm x 12mm on walls above DPC edge and filled with Polysulphide Sealent as grouting compound. Complete and Finished in all respect as per company specification and Engineer-in-charge.
Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge.(Cost of the reinforcement will be paid extra) 12 mm diameter of reinforcement bar as per embedment depth..
Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge.(Cost of the reinforcement will be paid extra) 16 mm diameter of reinforcement bar as per embedment depth..
Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge.(Cost of the reinforcement will be paid extra) 20 mm diameter of reinforcement bar as per embedment depth..
Waste Bin Providing 60 liters wheeled garbage bin of approved brand with best quality lid of different colours i.e. Green, Blue and Yellow.
UREA CORROSION RESISTANCE COATING Providing and applying a chemical and abrasion resistant , high build, two-pack epoxy-novolac system specially designed to provide a tough and impermeable high chemical resistant film at a thickness of 500 micron. The coating should able to resist wide range of chemicals both acid and alkaline having Ph value 1 o 14. The cured flim should have Tensile strength 30 N/mm²,Elongation 3%,flexture strength 45 N/mm²,Compresive strength 95 N/mm². Internal faces
RECRON 3S Extra over Item 2.2.1 Providing Recron 3S shall be mixed with the approved concrete and laid over prepared subbase. The work shall be carried out as per direction by Engineer-in-charge. The materials, loading, unloading, transporting to site, removing rubbish from site, all taxes etc. complete for all lead and lift. VDF concrete
Fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates (in columns and trusses), bolts and nuts complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Supplying materials and laying 25 mm thick self adhesive closed-cell nitrile elastomeric rubber insulation foam with non-porous composition, aluminium foam on one side, high thermal efficiency as well as protection from imminent condensation problems.The product should be environmental friendly and zero Ozone Depletion Potential (ODP). The self adhesived sheets are to be cutted in required size and shape should be fixed with necessary screws and rubber washers fixed to the truss members on both the direction. Including necessary accessories for fitting and fixing of sheet in position as complete as per the instruction of Engineer In Charge. The basic property of the material should be as follows : Fire rated “CLASS O” as per BS 476 Parts 6 & 7; Water vapour permeance (0 perms); Water vapour diffusion factor (> 10,000); Water absorption rate (0.06% by volume); Thermal efficiency (λ24˚ C = 0.033 W/mK; λ46˚ C = 0.036 W/mK); Temperature range (from -50˚ C to +105˚ C); Antibacterial & antifungal; Environmental friendly – ODP = 0; Low VOC emission level
Point wiring in Steel conduit, with piano type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in recess or surface Steel conduit ( to be fitted with the truss member by spot welding ) ,with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make as approvedby CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. Group A
Point wiring in Steel conduit, with piano type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in recess or surface Steel conduit ( to be fitted with the truss member by spot welding ) ,with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make as approvedby CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. Group B
Point wiring in Steel conduit, with piano type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in recess or surface Steel conduit ( to be fitted with the truss member by spot welding ) ,with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make as approvedby CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. Group C
Indoor Main External Power Disbribution Board Supply, installation, testing and commissioning of following External LT power distribution Panel Boards of 2 mm thick CRCA MS sheet steel cubical design for indoor WALL mounting factory fabricated suitable for operation on 440 V, 3 phase, 50 Hz, A.C. supply with 24 Hrs. time switch/ MCBs/ contactors, and other accessories, all in compartmentalised, cubical construction complete in all respects as per approved drawing and design including internal wiring, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs for out gogoing , cable termination gland plates, painting etc. conforming to specifications as required. The panel shall have porvision of cable entry and out going at the bottom. The bus bar shall be sized with current density of Amperage 1A/sq.mm and MCB shall be connected using FR cables of proper rating. 24 Hours time switch 1 no. 40A TP, 36KA, MCB for incoming feeder 1 no 63 A NO TP Contactor 1 no. 200 A Aluminium Bus bars with heat shrinkable color coded PVC sleeves shall be of E91E grade. Neutrar bar 25 A DP , 20KA, MCB for out gogoint 10 no
UNDER GROUND CABLE WORKS Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 3.5 Core, 120 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
Supply of Streeet light, Fitting and Fixtures Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Supply of 70 W LED W IP66 aerodynamically design made out of die cast Aluminium housing and head frame, powder coated in approved color including driver and accessories as required. . for B - block road side area Make; CGL make Ref. Cat No. Hawk Neo LSTN170 CDL AM or equivalent Siska , Panasonic, Surya, Havells as approved.
Supply of 8 mtr long galvanised octagonal pole with inbuilt JB arrangement HAVING DIN bar and Earth link bar (Top 70mm, Bottom 155mm, Thickness 3mm, Base plate 220x220x12 mm , 220 mm PCB. With single arm Make Crompton, Jindal, Niozon as approved.
TRANSFORMER 11KV Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 100 KVA,50Hz.11/0.433 KV. Oil filled copper winding transformer with Off Circuit tap change.Make ; Power Maker, Kirloskar or equivalent as approved.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Installation of Light fittings Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre
410 SP 43 Length of pole = 10.00 metre., Length of sections, Bottom = 5.20 M, Middle = 2.40 M, Top = 2.40 M, Out side dia. & Thickness Bottom = 165.10 x 4.50 mm, Middle =138.70 x 4.50 mm, Top =114.3 x 3.65 mm
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying and fitting fixing pole clamp complete as required and as directed by the department.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. For transformer grounding.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SECURITY DEPOSIT Drawing of 11KV overhead line including necessary insulators angles frames stay wires etc. as necessary and load security deposit to be deposited to concerned Power Supply Agency including ASEB check meter
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 2 way 5/6 A switch
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 150mm X 75 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
SUB POWER DISBTIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole for TPN DB incoming
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with the truss member by sport welding ) as required.. Make : conduit as approved by CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. 2 x 1.5 Sq.mm + 1 x1.5 Sq.mm earth wire for common light point wiring from Primary point to two nos. secondary points as shown in the drawing
SUB MAIN WIRING FROM SPN DB TO SB Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ( from SPN DB to Switch boards ) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 12 - way , Double door
SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 8 - way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral (16 KA)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
CEILING & EXHAUST FAN Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Earthing Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as required for out door lighting system & indoor DBs. One for VTPN and 1 for washr room and 1 for cofee house .
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing earth bus bar joint made of 20mmx3mm thick 125 mm long with 4 nos. G.I bolts , nuts, chuck nut and spring washers etc. complete as requried
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35sq. Mm
Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 2 X 6 sq. mm (19mm)
Misecellineous Items - GI Pipes Supplying and embedding following G.I pipe of medium class for cable entry / road crossing of cable etc. including bending the pipe as required shape as required. b) 40 mm dia
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Sisk / CGL/ Havells/ Surya or Panasonic as approved 1 x 20 W LED 6500K retrofitting polycarbinateT8 tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 and for batten unilite DMLN1LT8-16 or equivalent Siska or Havells , phillips, bajaj as approved. for small class room lighting
Supply and installation of angle batten holder with 12W LED NW lamp .
CEILING & EXHAUST FAN Supply and Installation of 1200 mm sweep white summer cool ceiling fan. Make ; Oirent summer cool or equivalent Havells or CGL make as approved.
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Supply of 150mm high spped exhaust fan having automatinc lovour shutter . Make ; Oirent Ventilator HS or equivalent Havells, CGL or Panasomic make as approved. For Toilets
Supply of 300 mm high spped exhaust fan . Make ; Oirent or equivalent Havells, CGL or Panasomic make as approved. For Kitchens
Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover requires for earthing point to cover.
Fire Extenguisher Supply and istallation of 4.5 Kg, Mild steel ABC, A class powder/ CO2 type fire extenguisher
UNDER GROUND CABLE WORKS Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 3 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
EXTERIOR PAINTS / COATINGS Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
CARRIAGE OF MATERIALS By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal size Cost of carriage including loading, unloading & stacking for first 50 metres. 15 KL RWH Pit
CARRIAGE OF MATERIALS By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal size Every additional lead of 50 metre or part thereof beyond 1st 50 metre 9 such additional lead. 15 KL RWH Pit
CARRIAGE OF MATERIALS By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal size and above. Cost of carriage including loading, unloading & stacking for first 50 metres. 15 KL RWH Pit
CARRIAGE OF MATERIALS By Manual Labour including loading, unloading and stacking for lead less than 0.50 KM Sand, stone aggregate below 40 mm nominal size and above. Every additional lead of 50 metre or part thereof beyond 1st 50 metre 9 such additional lead. 15 KL RWH Pit
Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : Up to 6 metres depth 15 K RWH Pit
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 90mm dia. 15k RWH pit
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
DISTEMPERING Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.
DOORS & DOOR FRAMES Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
INDIAN TYPE WATER CLOSET Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
WASH BASIN Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
MIRROR Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. (a) Parryware Make (ii) Wall Soap tray (Cat. No.C9951)
TOWEL RAIL,TOWEL RACK & TOWEL RING Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
GRATING Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 15 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 20 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 32 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 40 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal outer dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
BIB COCK Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :. 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :. 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :. 32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :. 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :. 50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110MM
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 75MM
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110MM
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75MM
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 500 litre capacity
URINAL Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110MM
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 75MM
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110MM
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75MM
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 110MM
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 75MM
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110MM
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75MM
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 110MM
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 75MM
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110MM
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 110MM
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110MM
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75MM
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75 mm x 75mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 75 mm x 75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. .(i) 110 mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. .(i)75 mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. .(i)110 mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. .(i)75 mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 110mm Dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 75MM dia
COWEL Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (iii) 90mm dia. PVC cowel of ISI make
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
CHOWKATHS Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). (a) With sal wood
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
MS GRILL Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats)
ALUMINIUM FITTINGS Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
A provisional sum of Rs 5,88,196.00 (Rupees Five Lakhs Eighty Eight Thousand One Hundred Ninety Six Only) for ESMP requirements is provided and to be operated and expended in whole or in part as per the instruction of Engineer.
GANPATI CONSTRUCTION COMPANY
POOJA ASSOCIATES(CONTRACT DIVN)
Puberun Real Estate Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .