Station Development
ELEC. GENL
15 conditions · 4 needing a document upload
The contractor shall hold a valid Electrical Contractor License issuedbythe competent State Electrical Licensing Board / ChiefElectricalInspectorate, duly authorizing the execution of Low Tension(LT)electrical installation works up to 650 Volts, including 415 V threephasesystems.Submission of a valid electrical contractor license alongwiththe bid is mandatory. Failure to upload the same shall render theofferliable for rejection.
As per Note (ii) of 5. Bid security Part I of Instructions to Tenderers(ITT) of GCC April 2022, "Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above". Bid security exemption cannot be claimed with Documents other than this and such offers will be summarily rejected.
Annexure VI B format of GCC April 2022 attested by Chartered Accountant has to be attached Mandatorily by tenderer along with Audited Balance sheet if the Advertised value of tender is Rs. 50 Lakhs and more.
Para 14 of Instructions to Tenderers of GCC April 2022 must be adhered by Tenderer and all the documents mentioned there has to be attached mandatorily according to the type of Constitution of business like Sole proprietorship, Company, LLP etc.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
33 conditions · 4 needing a document upload
The Stores materials which are supplied by Railways shall be collected from SSE/E/Works/SA stores duly transporting the same to the site by own cost borne by the contractor only. The released Railway materials if any should be handed over to the maintenance concerned SSE/Power stores duly getting forwarding acknowledgement from SSE/E/Works concerned.
I/We also hereby agree to abide by the updated Regulations of Tendersand Contracts and General Conditions of Contract issued by theEngineering Department of Indian Railways along with correction slipsissued from time to time and to carryout the work according to the SpecialConditions of Contract and specifications of materials and works as laiddown by Railway in the Annexed Special Conditions / Specifications,Schedule of Work for the present contract.
All rates quoted in the tenders shall be deemed to be inclusive of CGST,SGST, IGST etc., payable by the contractor to the Government or anypublic body and no additional amount/rate or claim will be entertained onthis account by the Railways. Also no claim whatsoever will be accepted byRailways on account of revision of tax rates, new taxes of statutory natureby State/Central Govt.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We have read the various conditions to tender attached hereto and agree to abide by the said conditions
I/We also agree to keep this tender open for acceptance for a period of 60 days from the date fixed for opening the same
I/We offer to do the work for Divisional Electrical Engineer, Electrical Operations, Salem Division, Salem, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of commencement of work of the tender. The amount as stipulated in the tender document is herewith forwarded as Earnest Money. Full value of the earnest Money shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if :(a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC 2019 as detailed in general instructions.(b) I/We do not commence the work within seven days after receipt of LOA/orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
The Contractor shall submit a statement to the effect that noretired Engineer or retired Gazetted Officer is associated withthe tenderer as per Appendix-D. Tenders without the informationabove referred to or a statement to the effect that no suchretired Engineer or retired Gazetted Officer is so associated withthe tenderer, as the case may be, shall be rejected.
All the tenderers/Contractors have to deposit full earnest money and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards only. On failing which offer will be summarily rejected.
The Tenderer should submit a copy of GST/PAN and NEFT Form.
Payment of EMD and Tender form cost should be made on line only.
GCC 2022- All GCC clauses (updated including with all correction slips on date) are applicable.
i)For all the tenders having advertised cost of Rs. 10 lakh or above, thecontractor shall have the option to take payment from Railways through aletter of credit (LC) arrangement. (ii)This option of taking payment through LCarrangement has to be exercised in IREPS (Indian Railway ElectronicProcurement System - the e-application on which tenders are called byRailways) by the tenderer at the time of bidding itself, and the tenderer shallaffirm having read over and agreed to the terms and conditions of the LCoption.(iii)The option so exercised, shall be an integral part of the bidder'soffer.(iv)The above option of taking payment through LC arrangement, onceexercised by tenderer at the time of bidding, shall be final and no change shallbe permitted, thereafter, during execution of contract.(v)In case tenderer optsfor payment through LC, following shall be the procedure to deal release ofpayment through LC:(a)The LC shall be a sight LC.(b)The contractor shallselect his Advising/Negotiating bank for LC. The incidental cost towards issueof LC and its operation thereof shall be borne by the contractor.(c)SBI, NewDelhi, Main Branch will be the nodal branch for issue of LCs based on onlinerequests received from Railway Accounts Units for tenders opened in financialyear 2019-20. SBI branches where the respective Railway Accounts Office hasits Account (local SBI branch) will be the issuance/reimbursing branch for LCissued under this arrangement. The Bank shall remain same for this tender tillcompletion of contract. The incidental cost @ 0.15 % per annum of LC value,towards issue of LC and operation thereof shall be borne by the contractorand shall be recovered from his bills.(d)The LC shall be opened initially forduration of 180 to 365 days in consultation with contractor. The LC shall beextended time to time as per the progress of the contract, on the request ofthe contractor. The value of LC to be opened initially as well as extendedthereafter shall be finalised by the engineer in consultation with the contractoron the basis of expected progress of work.(e)The LC terms and conditionsshall inter-alia indemnify and save harmless the Railway from and against alllosses, claims and demands of every nature and description brought orrecovered against the Railways by reason of any act or omission of thecontractor, his agents or employees, in relation to the Letter of Credit (LC). Allsums payable/borne by Railways on this account shall be considered asreasonable compensation and paid by Contractor.
(f)The LC terms and conditions shall inter-alia provide that Railways will issue a Document of Authorisation after passing the bill for completed work, to enable contractor to claim the authorized amount from their bank. (g)The acceptable, agreed upon document for payments to be released under the LC shall be the Document of Authorisation. (h)The Document of Authorisation shall be issued by Railway Accounts Office against each bill passed by Railways. (i)On issuance of Document of Authorisation, a copy of Document of Authorisation shall be posted on IREPS for download by the contractor. A digitally signed copy of Document of Authorisation shall also be sent by Railway Accounts Office to Railway's bank (Local SBI Branch). (j)The contractor shall take print out of the Document of Authorisation available on IREPS and present his claim to his bank (advising Bank) for necessary payments as per LC terms and conditions. The claim shall comprise of copy of Document of Authorisation, Bill of Exchange and Bill. (k)The payment against LC shall be subject to verification from Railway's Bank (Local SBI Branch). (l)The contractor's bank (advising bank) shall submit the documents to the Railways Bank (Local SBI Branch). (m)The Railway's bank (issuing bank) shall, after verifying the claim so received w.r.t. the digitally signed Document of Authorisation received from Railway Accounts Office, release the payment to contractor's bank (advising bank) for crediting the same to contractor's account. (n)Any number of bills can be dealt within one LC, provided the sum total of payments to contractor is within the amount for which LC has been opened. (o)The LC shall shall be closed after the release of final payment including PVC amount, if any, to the contractor. (p)The release of performance guarantee or security deposit shall be dealt directly by Railway with the contractor i.e., not through LC
Deployment of Qualified Engineers at Work Sites by the Contractor - TheContractor shall employ 1 No. of qualified Graduate Engineer for works Rs. 200Lakh or more and 1 No. of Diploma Engineer for works costing more than Rs. 25Lakh, but less than Rs 200 Lakh
Salem Division -Provision of Facade lighting for Tiruppur (TUP) station under Amrit Bharat Station Scheme -Electrical arrangements.
SA-E10-2026-27-W2~SR
SA-E10-2026-27-W2
Open
Works - General
6 Months
Salem, Tamil Nadu
₹0
₹94,800
7 Aug 2026
7 Aug 2026
17 Aug 2026
61 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 47,39,970 | ||
| — | 95.00 | — | — | ||
| Supply, installation, testing, and commissioning of exterior BIS registered 24W 24V DC RGBWLinear LED Wall Washer luminaire for facade lighting with extruded aluminum housing, powder-coated finish, andClear toughened glass. With all LEDs ON, minimum system lumen efficacy equal to or greater than 62.9 lm/w.The luminaire shall be capable of producing dynamic color- changing light with 16 million colors as the light fixtureshould be programmable using 8-bit control DMX512 protocol / Ethernet based control. Luminaire should becomplete with a dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of differenttypes such as narrow, medium, wide or elliptical as per the site requirement. The fixture should be erected withthe necessary required brackets and should have constant locking hinges for simple position control from variousangles without special tools. Fixture shall be suitable to operate at an ambient temperature range of -30°C to50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70@ 25C @ 50000burning hours at 25°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS/ LUMILEDS/CREE/LEDNIUM/ AVAGOmake. The product should be BIS approved with R number mentioned on product label. To be supported withProduct test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixtureincluding weather proof connection cables, water proof connectors etc. as required. This includes crane chargesif any for height work. (Warranty Period of 5 years). All test reports and technical data sheets to be submitted tothe competent authority for approval. After installation, assembling and commissioning contractor should ensurethat all parts of the light are properly fixed and put it into running condition. The entire work should be carried outas per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for aminimum period of 1 week. | — | — | — | 7,79,760 | |
| — | 90.00 | — | — | ||
| Supply, installation, testing, and commissioning of exterior BIS registered 36W 24V DC RGBWLinear LED Wall Washer luminaire for facade lighting with extruded aluminum housing, powder-coated finish, andClear toughened glass. With all LEDs ON, minimum system lumen efficacy equal to or greater than 62.9 lm/w.The luminaire shall be capable of producing dynamic color- changing light with 16 million colors as the light fixtureshould be programmable using 8-bit control DMX512 protocol / Ethernet-based control. The luminaire should becomplete with a dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of differenttypes such as narrow, medium, wide, or elliptical as per the site requirement. The fixture should be erected withthe necessary required brackets and should have constant locking hinges for simple position control from variousangles without special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to50°C and the complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70@ 25C @50000 burning hours at 25°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS/LUMILEDS/CREE/LEDNIUM/AVAGO make. The product should be BIS approved with R number mentioned onproduct label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaireshall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessoriesrequired for proper working of fixture including weather proof connection cables, water proof connectors etc. asrequired. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports andtechnical data sheets to be submitted to the competent authority for approval. After installation, assembling andcommissioning contractor should ensure that all parts of the light are properly fixed and put it into runningcondition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures tobe done in the presence of Site Engineer for a minimum period of 1 week. | — | — | — | 14,04,360 | |
| — | 32.00 | — | — | ||
| Supply, installation, testing & commissioning of 200 watt DC 24V Constant Voltage driver to operate lighting systems having multiple LED modules connected in parallel, hence to make architectural lighting systems with a very slim form factor and seamlessly integrated into various structures. The driver should be commissioned with all necessary electrical connections and have following features: DC24V Constant Voltage Switch Mode Power Supply, Waterproof IP65 or above ingress protection, efficiency more than 85%. Operating temperature: -30 to +65 degree centigrade, THD less than 20% with necessary connections, Warranty : 5 Years, Electrical Safety Class: Class 1. (The work to be executed as per direction of engineer in charge at site. If any other items have been omitted but required for efficient working for facade lighting it would be responsibility of contractor to supply and provide such items. However the quoted rate shall be inclusive of those items) | — | — | — | 61,184 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of 90W Narrow Beam RGBW LED Projector Lights , DC 24V with IP 65 Protection, Cast Aluminium Double powdered paint, 4mm safety glass IP 68 Connectors, Luminaire efficacy required minimum guaranteed 50 lumen/watt, CRI > 80, Projecting Distance 30 Mtr, Control mode in DMX switchable dimmable / tunable, static Lighting. The product should be BIS approved To be supported with Product test reports and LEDs Test Reports. Luminaire shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. This includes crane charges if any for height work.(Warranty Period of 5 years). All test reports and technical data sheets to be submitted to the competent authority for approval. After installation, assembling and commissioning contractor should ensure that all parts of the light are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for a minimum period of 1 week. | — | — | — | 19,904 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing, and Commissioning of exterior BIS registered 125W LED RGBW floodlighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum systemlumen efficacy equal to or greater than 50lm/w. The luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDEapproved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical asper the site requirement. Fixture with constant locking hinges for simple position control from various angleswithout special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°Cand the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burninghours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/ LEDNIUM/AVAGO make.DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67potted driver and capable of operating at line voltage from 90- 305 Vac, 50Hz with power factor > 0.9. The productshould be BIS-approved with the R number mentioned on the product label. To be supported with Product testreports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5)and shall be complete with all necessary accessories required for the proper working of the fixture includingweatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any forheight work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to thecompetent authority for approval.After installation, assembling, and commissioning contractor should ensure thatall parts of the light are properly fixed and put it into running condition. The entire work should be carried out asper the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for aminimum period of 1 week. | — | — | — | 1,50,720 | |
| — | 13.00 | — | — | ||
| Supply, Installation, Testing, and Commissioning of exterior BIS registered 90W LED RGBW floodlighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum systemlumen efficacy equal to or greater than 50lm/w. The luminaire shall be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDEapproved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical asper the site requirement. Fixture with constant locking hinges for simple position control from various angleswithout special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°Cand the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burninghours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS/ LUMILEDS/CREE/LEDNIUM/AVAGO make.DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The productshould be BIS-approved with the R number mentioned on the product label. To be supported with Product testreports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5)and shall be complete with all necessary accessories required for the proper working of the fixture includingweatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any forheight work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to thecompetent authority for approval. After installation, assembling, and commissioning contractor should ensure thatall parts of the light are properly fixed and put it into running condition. The entire work should be carried out asper the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for aminimum period of 1 week. | — | — | — | 5,45,519 | |
| — | 5.00 | — | — | ||
| Supply, Installation, Testing, and Commissioning of exterior BIS registered 55W LED RGBW floodlighting luminaire for facade lighting with Die-cast aluminum housing, powder-coated finish, minimum systemlumen efficacy equal to greater than 50 lm/w. The luminaire shall be capable of producing dynamic colorchanging light with 16 million colors as the light fixture should be programmable using 8-bit control DMX512protocol / Ethernet-based control. The luminaire should be complete with a dedicated Lens made up of UL/VDEapproved PC for each LED, offering beam angles of different types such as narrow, medium, wide, or elliptical asper the site requirement. Fixture with constant locking hinges for simple position control from various angleswithout special tools. The fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°Cand the complete luminaire shall be IP66 and IK07 rated. LED Lifetime shall be at least L70B50 @ 50,000 burninghours at 50°C. LED should be of NICHIA/OSRAM/SEOUL/PHILIPS LUMILEDS/CREE/LEDNIUM/AVAGO make.DMX enabler circuit should be inside the Luminaire only. Luminaire shall be complete with integrated BIS IP 66/67potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. The productshould be BIS-approved with the R number mentioned on the product label. To be supported with Product testreports - LM79, BIS Report, and LEDs Test Reports. Luminaire shall conform to BIS i.e. IS 10322 (Part 5/Sec 5)and shall be complete with all necessary accessories required for the proper working of the fixture includingweatherproof connection cables, waterproof connectors, etc. as required. This includes crane charges if any forheight work.(Warranty Period of 5 years). All test reports and technical data sheets are to be submitted to thecompetent authority for approval. After installation, assembling, and commissioning contractor should ensure thatall parts of the light are properly fixed and put it into running condition. The entire work should be carried out asper the instructions of Site Engineer. Testing of the fixtures to be done in the presence of Site Engineer for aminimum period of 1 week | — | — | — | 1,72,005 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing & commissioning of Sky cove LED RGB flexible strip light strip 5 mtr long (1 roll) with 7.2 watt per meter with driver Model, LED strip should have 30 nos LEDs per meter through out the length with the silicon cover. The strip should have IP 68 protection and should have cover Glue Injected with polyurethane.The nominal voltage should be DC 24V, working temperature range should be between -20 deg C to +50deg c. work should be completed with necessary factory made weather proof cable, lenses and external power and data supply[if any]. suitable fixing arrangement as required complete in all respect as per direction of engineer in charge, warranty:-5 years, electrical safety class: class 1 (The work to be executed as per direction of engineer in charge at site). | — | — | — | 20,440 | |
| — | 320.00 | — | — | ||
| Supply Erection testing and commissioning of DMX signal cable / shielded Cat. 6 or better data cable shall be used for digital communication networks. Size and quantity of cable shall be as per site requirement and as directed by SSE Incharge. Copper lugs, glands of proper size shall be used for connections | — | — | — | 84,160 | |
| — | 227.00 | — | — | ||
| Supply Erection testing commissioning of male-Female sets for connecting DMX cable of RGB fitting with 5-pin DMX XLR connectors for lighting cables and Effects,Set includes one male connector and one female connector, Gold pins for optimum signal transfer,Stranded Tinned Copper Conductors,PVC Jacket, Length - 6 inches | — | — | — | 1,75,471 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of DMX Splitter with Input Voltage range : 100- 240V 50-60Hz AC, Power Consumption 4W/8W max. Housing is made of polycarbonate with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature -17°C to +55°C, 5 Output with 5pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 5 DMX output per universe/10 DMX output for double rack versions. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment. All test reports and technical data sheets to be submitted to the competent authority for approval. After installation, assembling and commissioning contractor should ensure that all parts of the DMX splitter are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the DMX splitter to be done in the presence of Site Engineer for a minimum period of 1 week. The make of the cable used shall be approved by Railways | — | — | — | 1,46,124 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing and Commissioning, of DMX Controller for the system including all other accessories required for the running of the system Controller should have Input Power 5-12V DC and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet. DMX controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It must have sufficient DMX512 RJ45 ports and sufficient RS-232 - pin serial ports. It must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presets and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C. OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad/Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta; clamp to mount on wall. Facade lighting product and its driver should be compatible with DMX controller. To be provided with IP 66 polycarbonate enclosure. (Warranty Period of 5 years). All test reports and technical data sheets to be submitted to the competent authority for approval. After installation, assembling and commissioning contractor should ensure that all parts of the DMX controller are properly fixed and put it into running condition. The entire work should be carried out as per the instructions of Site Engineer. Testing of the DMX controller to be done in the presence of Site Engineer for a minimum period of 1 week | — | — | — | 1,77,372 | |
| — | 10.00 | — | — | ||
| Supply at site fixing testing and commissioning of 5 Watts IP66 Protected COB LED spike light to be offered in Mono - Red (or) Green (or) Blue (or) Warm White Colour based on the site condition. Should have environmental friendly, compact, light weight, energy saving The Spike light should be Offered Warm White Colour. Multi purpose application like column lighting, tree up- lighting, statue accentuation etc. can be and toughened glass Adjustable mounting bracket with spike is provided for easy focus on the object , constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection Luminaire is wired with inbuilt driver with 4.5kV surge protection and wiring by 3 C x 1.0 sq.mm PVC insulated & sheathed round flexible copper cable in an approved manner as directed section Engineer in charge at site | — | — | — | 24,640 | |
| — | 20.00 | — | — | ||
| Supply at Site fixing testing and commissioning of 9W landscape Bollard of height 1m made up of Graphite grey powder-coated GI Pipe housing. Sample to be submitted for approval before supply, The luminaire shall have opal acrylic diffuser with IP65 protection is fixed in a die-cast aluminium base for pleasant light output LEDs mounted on a die-cast aluminium base Luminaire is available with colour temperature: Warm White (WW): 3000K 250K Luminaire is wired with an inbuilt driver with 4.5kV surge protection device, having constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection. And Installation of the above bollard fixtures complete with pole of height 1m or above compatible for the above bollard with terminal connections & mounting accessories suitable and concrete foundation alongwith wiring by 3 C x 1.0 sq.mm PVC insulated & sheathed round flexible copper cable in an approved manner as directed section Engineer in charge at site | — | — | — | 65,500 | |
| — | 20.00 | — | — | ||
| Design, supply, installation, testing and commissioning of aesthetically designed IP65 type LED Post Top Lantern of 45 Watts, with symmetrical light distribution, spun aluminium top cover landscape luminaire with high-power LEDs as light source, complete with 4.0 mtr high suitable decorative post, provided with suitable base plate along with four foundation bolts, brackets/adaptors and all necessary accessories, with inbuilt driver, 4.5 kV surge protection device and constant-current electronic driver having operating voltage range of 140-280 V AC, with high- voltage, open-circuit and short-circuit protection; sample of the luminaire shall be submitted for approval before supply. The work shall include installation of the above post-top fixture complete with suitable RCC/concrete foundation for the pole, including excavation, reinforcement, four foundation bolts, base plate, grouting and all associated civil works, wiring by 3C x 1.0 sq.mm PVC insulated and sheathed round flexible copper cable, including necessary glands, lugs, connectors and accessories, complete in all respects with transportation, labour, tools, tackles, testing and commissioning, as directed by the Section Engineer-in-Charge at site and to the approval of the Engineer-in-Charge. | — | — | — | 1,80,180 | |
| — | 5.00 | — | — | ||
| Supply Erection testing and commissioning of LED Aesthetically designed, decorative strip light for decorative & cove lighting applications 22W /5 Mtrs with necessary driver,3M adhesive tape on the back for fixing | — | — | — | 1,345 | |
| — | 10.00 | — | — | ||
| Supply at site fixing testing and commissioning of decorative wall mounting light 20 Watts made up of Polycorbonate diffuser with Graphite powder coated die-cast aluminium alloy fitting suitable for outdoor use with high material resistant to discoloration working on 220 V AC Supply, Colour of LED : Cool white/Warm white, Luminaire is wired with inbuilt driver with 5kV surge protection, Constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection duly fixing in the wall and wiring by 3 C x 1.0 sq.mm PVC insulated & sheathed round flexible copper cable in an approved manner as directed section Engineer in charge at site | — | — | — | 16,160 | |
| — | 1410.00 | — | — | ||
| Supply and laying of 4CX2.5sqmm XLPE insulated armoured copper cable suitable for Rated Voltage of 1100V grade and conforming to IS 7098 part I with amendment number 1 2 and 3 reaffirmed 2005 or latest and IS 8130 with latest amendments and with ISI marking. Cable shall be supplied by the OEM or their authorized dealer duly producing dealership certificate Cable shall be tested by CPRI ERDA NABL or any other laboratories recognized by the Govt. of India test certificate and OEM warranty certificate shall be produced by the supplier along with the supply of the cable. | — | — | — | 2,15,730 | |
| — | 149.00 | — | — | ||
| Supply and termination of Polyamide cable glands & copper lugs suitable for terminating 4C x 2.5 sqmm XLPE Insulated armoured copper cable. Cable Glands - Cable shall be terminated using double compression type cable glands. Testing requirements of Cable glands shall conform to BS:6121 and gland shall be of robust construction capable of clamping cable and cable armour (for armoured cables) firmly without injury to insulation. Cable glands shall be made of heavy duty brass machine finished and nickel chrome plated. Thickness of plating shall not be less than 10 micron. All washers and hardware shall also be made of brass with nickel chrome plating Rubber components shall be of neoprene or better synthetic material and of tested quality. Cable glands shall be suitable for the sizes of cable supplied/erected. Cables to be terminated - Unarmored HT power cables, Armoured and Unarmored LT power cables, unarmored Control cables and unarmored Screened (instrumentation) cables 2. Cable Lugs - Cable lugs for power cables shall be tinned copper solderless crimping type suitable for copper compacted conductor cables. Cable lugs and ferrules for control cables shall be tinned copper type. All power cable lugs shall be Single hole type. The cable lugs for control cables and screened/instrumentation cables shall be pin type and shall be provided with insulating sleeve. Cable lugs and ferrule shall conform to DIN standards. | — | — | — | 17,582 | |
| — | 1410.00 | — | — | ||
| Supply Erection testing commissioning of 14 SWG GI Earth wire including binding with 16 SWG GI wire complete Hard drawn GI, 14 SWG shall be erected at site as per requirement and is should be bind with 16 SWG GI wire in proper manner, nuts check nuts to be fixed from underside the bottom bracket with one set of nut on the top and other set of at the bottom to keep the wire in position for supporting/ terminating of the guard wire. The work shall be done in an approved manner as per the site conditions and instructions of field Engineer | — | — | — | 5,640 | |
| — | 117.00 | — | — | ||
| Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRP JB (IP 65) Size: 139x119x70 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm XLPE armoured cable,The junction box be 2.7 mm thick with electrically insulated body shock proof, connector leads and control equipped with 1 nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight. The junction box shall be vermin proof having rubber bushes at cable entry. The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size. Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer | — | — | — | 1,06,236 | |
| — | 32.00 | — | — | ||
| Supply and Installation of Junction Boxes, Pipes & flexible conduit of FRP JB (IP 65) Size: 260x210x116 mm with stud type terminal suitable for terminating 4c x 2.5 sq.mm armoured cable & housing 1 driver,The junction box should be 2.7 mm thick with electrically insulated body shock proof, connector leads and control equipped with 1 nos.16 amps rewireable fuse and its neccessary cutout. The box should be of front door opening with rubber gasket to make it water tight. The junction box shall be vermin proof having rubber bushes at cable entry. The junction box shall be mounted on pole/ wall etc at the height of 1.50 mtrs or as per site condition by providing MS clamps of suitable size. Color of junction box shall be got approved before erection. The junction box shall be erected in an approved manner as per the site condition and instructions of field Engineer | — | — | — | 35,808 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, installation, testing and commissioning of 25 Watts all-in-one solar street light (LED based), comprising white LED luminaire (LED + driver) of suitable rating as per the approved configuration, complete with Solar PV module(s), LiFePO4 battery of specified capacity, necessary control electronics, interconnecting wires/cables, module mounting structure and all other required accessories, suitable for automatic operation from dusk to dawn. The LED street light shall conform to the technical specifications specified in Annexure-I and shall be submitted for approval before supply. The complete unit shall be mounted on a 4.0 mtr high, suitable rust-resistant decorative post, provided with a suitable base plate, foundation bolts, brackets/adaptors and all necessary accessories. The work shall include a suitable RCC/concrete foundation for the pole, including excavation, reinforcement, foundation bolts, base plate, grouting and all associated civil works, along with wiring by 3C x 1.0 sq.mm PVC insulated and sheathed round flexible copper cable, including necessary glands, lugs, connectors and accessories, complete in all respects with transportation, labour, tools, tackles, installation, testing and commissioning, as directed by the Section Engineer-in-Charge at site and to the approval of the Engineer-in-Charge. | — | — | — | 2,18,680 | |
| — | 50.00 | — | — | ||
| Supply of MS work of miscellaneous size and for cable tray etc including painting complete. | — | — | — | 3,550 | |
| — | 50.00 | — | — | ||
| Fabrication fixing and erection of MS work of miscellaneous size,riveted, bolted or welded in built up sections including cutting, grinding and straightening, drilling, riveting, handling, hoisting and fixing in position etc. including applying a priming coat of approved steel primer etc. and duly painted with fine finish with contractors steel and materials. The work shall be done as per the site requirement in an approved manner and as per the instructions of field supervisor. | — | — | — | 500 | |
| — | 70.00 | — | — | ||
| Supply and concealing of rigid PVC conduits of 25 mm Dia (IVORY colour) confirming to IS 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0mm along with the all accessories and including cutting the wall/ceiling/chipping or elsewhere and making good the same as directed by Engineer in charge at site. | — | — | — | 3,500 | |
| — | 1410.00 | — | — | ||
| Supply and fixing of PVC conduits (IVORY colour) of 25 mm Dia confirming to IS:9537/P3/1983 or latest(ISI Marked) with wall thickness not less than 2.0 mm along with, all accessories on wall surfaces and clamped at regular intervals, as directed by Engineer in charge at site | — | — | — | 84,600 | |
| — | 25.00 | — | — | ||
| Supply and wiring (Single phase) including termination by using 2 Nos. of 4.0 sq.mm PVC insulated FRLS type flexible copper cable conforming to IS.No:694, 1100 V grade with 1 No. of 14 SWG tinned copper wire/4.0 sq.mm flexible copper cable through the PVC pipe already laid.Color coding shall be followed as directed by Engineer incharge at site. (2 Nos. of 4.0 Sq.mm Copper cable and 1 No. of 14 SWG tinned copper wire shall be taken as 1 Mtr. for measurement purpose) | — | — | — | 3,900 | |
| — | 60.00 | — | — | ||
| Supply and wiring of 2 Nos. of 2.5sqmm PVC insulated flexible copper wire & 1 No. of 1.5 Sq.mm PVC insulated multi strand copper wire including supply and fixing of PVC conduit/casing and capping with all accessories like round block, ceiling rose, flexible wire for connecting lights,fan fittings etc as per specification. (2 Nos. of 2.5 Sq.mm Copper cable and 1 No. of 1.5 Sq.mm PVC insulated multi strand copper wire shall be taken as 1 Mtr. for measurement purpose). PVC conduit/casing and capping to be used as per site condition | — | — | — | 7,800 | |
| — | 2.00 | — | — | ||
| Supply, erection and testing of L.T. Earthing arrangements duly stenciling of earth resistance value along with date as per Drg. no. CEE/CN/MS/16-2004, including supply and spreading of salt and charcoal 5 kgs in each for earth treatment etc , including supply / leading / laying /burying and concealing of 4 SWG GI wire from earth electrode to proposed MDB / SDB or elsewherein an approved manner as directed by Section Engineer in charge at site. | — | — | — | 11,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Booklet
ATTACHMENT
Drawings_I_merged.pdf
ATTACHMENT
Solarannexure.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
TenderDocument-below50LakhsPL.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].