Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32.6 LAdmitted-Finance | -2.01% | ₹32.6 L | L1 | Admitted-Finance |
Tender Value
₹33.3 L
EMD Value
₹66,590
Closing Date
2 Jan 2026, 2:00 pmClosed
AGM CE
FCI RO BHUBANESWAR
Construction of Fire Fighting Reservoir of 50000 Litres capacity at FSD Balijhori, FSD Attabira, FSD Rourkela and FSD Jharsuguda under DO Sambalpur Odisha Region ... 3rd call.
2025_FCI_890886_3
NIT- 06/2025-26
Open Tender
Civil Works
75 days
FSD Balijhori, FSD Attabira, FSD Rourkela and FSD
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹66,590
20 Jan 2026
23 Dec 2025
3 Jan 2026
23 Dec 2025
2 Jan 2026
23 Dec 2025
FSD Balijhori
Earth work in excavation by mechanical means ( Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 50 m and for all lifts, disposed earth to be leveled and neatly dressed. All Kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC. Work including straightening ,cutting bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more
Centering and shuttering including strutting,propping etc. and removal of form for, Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting,propping etc. and removal of form for, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.: FOR RCC WALL
Centering and shuttering including strutting,propping etc. and removal of form for, Lintels, Beams, plinth Beams, girders, bressumers and cantilevers: FOR BEAM
Centering and shuttering including strutting,propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m. and for all lift.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means , including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge , beyond 50 m initial lead, for all leads including all lifts involved.
FSD Attabira
Earth work in excavation by mechanical means ( Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 50 m and for all lifts, disposed earth to be leveled and neatly dressed. All Kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC. Work including straightening ,cutting bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more
Centering and shuttering including strutting,propping etc. and removal of form for, Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting,propping etc. and removal of form for, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.: FOR RCC WALL
Centering and shuttering including strutting,propping etc. and removal of form for, Lintels, Beams, plinth Beams, girders, bressumers and cantilevers: FOR BEAM
Centering and shuttering including strutting,propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m. and for all lift.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means , including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge , beyond 50 m initial lead, for all leads including all lifts involved.
FSD Rourkela
Earth work in excavation by mechanical means ( Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 50 m and for all lifts, disposed earth to be leveled and neatly dressed. All Kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC. Work including straightening ,cutting bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more
Centering and shuttering including strutting,propping etc. and removal of form for, Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting,propping etc. and removal of form for, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.: FOR RCC WALL
Centering and shuttering including strutting,propping etc. and removal of form for, Lintels, Beams, plinth Beams, girders, bressumers and cantilevers: FOR BEAM
Centering and shuttering including strutting,propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m. and for all lift.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means , including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge , beyond 50 m initial lead, for all leads including all lifts involved.
FSD Jharsuguda
Earth work in excavation by mechanical means ( Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 50 m and for all lifts, disposed earth to be leveled and neatly dressed. All Kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC. Work including straightening ,cutting bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more
Centering and shuttering including strutting,propping etc. and removal of form for, Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting,propping etc. and removal of form for, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.: FOR RCC WALL
Centering and shuttering including strutting,propping etc. and removal of form for, Lintels, Beams, plinth Beams, girders, bressumers and cantilevers: FOR BEAM
Centering and shuttering including strutting,propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m. and for all lift.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means , including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge , beyond 50 m initial lead, for all leads including all lifts involved.
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
MTF_FFR_Sambalpur_merged.pdf
Tender Documents • 1.75 MB
BOQ_936403.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid