Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹21.8 LAccepted-AOC | l1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹23.6 L+₹27,300 (1.17%)Rejected-Finance ANURAGPUR PO PANAGARH BAZAR DIST BURDWAN WEST BENGAL 713 148 | PANAGARH BAZAR | BURDWAN | WEST BENGAL | 713148 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹23.7 L+₹36,020 (1.54%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹28.5 L+₹5.1 L (22.0%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹28.5 L+₹5.1 L (22.0%)Rejected-Finance | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_466647_1
8400-652/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D, Cat b (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹80,000
Yes
18 Nov 2021
10 Aug 2021
1 Sept 2021
10 Aug 2021
30 Aug 2021
23 Aug 2021
60 days
Amount
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) completer, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keetping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/floors and reuse the serviceable fittings under respective items complete all as specified and directed.
Material and labour for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers or modular cover plate with frame of suitable size and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 2.00 mentioned here-in-above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No 2.00 mentioned here-in-above but 5 Amp socket on same board with other switches. complete all as specified and directed.
Material and labour wiring for socket out let 3 pin ,15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers or modular cover plate with frame of suitable size and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Material and labour point wiring for light point/ fan point one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size , sheet top cover (ISI Marked) and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
All as per item No 6.00 mentioned here-in-above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
All as per item No 6.00 mentioned here-in-above but 5 Amp socket on same board with other switches. complete all as specified and directed.
Material and labour point wiring for one socket outlet on independent board controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated Unsheathed FRLS cables in and including suitable size PVC casing and caping (ISI marked) , including terminal switch boxes of suitable size, sheet top cover (ISI Marked) and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
S&F switch modular type 6 Amp one way, one module, single phase confirming to IS-3854-1997 complete all as specified and directed.
S&F socket outlet modular type 6 Amp 2/3 pin combined, two module, single phase confirming to IS-3854-1997 complete all as specified and directed.
S&F Switch socket Combination modular type 16A, 6 pin,three module, single phase confirming to IS-3854-1997 complete all as specified and directed.
S&F fan regulator modular step type 120 W 2 module suitable for 230 volt AC. complete all as specified and directed.
Supply and fix switch piano flush type, single pole , 6 Amps, one way ,complete all as specified and directed.
Fixing only switches of any type complete all as specified and directed. (Material obtained from srl item No 01)
Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed.
Refixing only 2 in 1, 5 Amp switch socket combination.complete all as specified and directed. (Material obtained from srl item No 01)
S&F socket outlets 2 in 1, 3 pin, 5/6 Amps for Same Board flush type 230/240 V, complete all as specified and as directed .
Supply and fix switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
Fixing only ceiling rose any type complete all as specified and directed. (Material obtained from srl item No 01)
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked, complete all as specified and directed.
S&F Bell push , flush type , 5 amp complete all as specified and directed.
S&F Buzzer, Ding dong, AC 230 Volts, single pole 230 volts complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified and directed.
S&F in repair two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F in repair two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F in repair two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC casing and caping (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
S&F in repair 01x 18 W LED batten light fittings, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as specified and directed.
S&F in repair security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including S & F 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed.
S&F in repair Surface mounted type decorative light fitting 1 x 10W LED 6k 230V AC, 50Hz complete with all accessories complete all as specified and directed.
S&F in repair Vertical distribution board (VTPN) double door TPN 6 way with IP 45 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, Neutral links complete with all accessories complete all as specified and directed.
S&F in repair Vertical distribution board (VTPN) double door TPN 4 way with IP 45 multiphase outgoing suitable for mounting 100 Amps as incomer with Bus bars, Neutral links complete with all accessories complete all as specified and directed.
S&F in repair epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed.
S&F in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed.
S&F in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed.
S&F in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed.
S&F in repair MCCB of 4 pole , 415volts of capacity 100 Amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting including necessry connection complete all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Taking down unservicable ceiling fan, Exhaust Fan, Air circulator, wall Fan of any type/ size/ Make/ Model for inspection for repairing action and deposite to E/M store yard complete all as specified and directed. Note: Cost of spair parts for repair shall be measured and paid seperately
Hanging/Fixing only ceiling fan, exhaust fan, air circulation fan, wall mounted fan, etc after necessary repair, painting complete all as specified and directed. Note: (i) Cost of spair parts for repair and painting shall be measured and paid seperately. (ii) The cost of oiling/ greasing/ replacement of rubber bush/hanging clamp etc as required are deemed to be included in the item rate.
Repair to unservicable ceiling fans, exhaust fan unscrewing nut and bolts etc and to change unservicable items for replacement including shifting of fans to workshop for overhauling, including replacement of unservicable bush/ bearing/ capcitor/ rewinding of coils with super enameled copper conductor of approved make as per existing guage of wire and numbers of turns per coils accessible to bring smooth functioning of the ceiling fan, exhaust fan etc complete all as specified and directed. Note: Cost of bearing, bush, capacitor, enamelled copper conductor coil for winding shall be measured and paid separately.
S&F of 2.5 Mfd Capacitor for Fan including taking out old unservicable one complete all as specified and directed.
S&F of 3.15 Mfd Capacitor for Fan including taking out old unservicable one complete all as specified and directed.
S&F of Bearing of size 6202 for Fan including taking out old unservicable one complete all as specified and directed.
S&F of Bearing of size 6201 for Fan including taking out old unservicable one complete all as specified and directed.
S&F copper conductor for rewinding of the coil of ceiling Fan/ Wall Fan/ Exhaust Fan etc. with super enamelled copper conductor, turn per coil, gauge with existing type including varnish for winding ,complete all as specified and directed.
S& Fgun metal bushes of any sizes for Fan any type/ size/ make/ model including taking out old unservicable complete all as specified and directed.
M&L for painting of ceiling fan/ exhaust fan /pedestal fan/ cabine fan complete with one coat of white synthetic enamel paint by spraying including filling cavities with fillerr after cleaning all dust etc including writing MES No (in block capital letter) with black paint etc, complete all as specified and directed.
S&F in repair of down rod heavy duty 15 mm dia , 1ft long for hanging of ceiling fan and fixing complete including joist of suitable size, bolts & nuts, washers, 2 nos rubber insulator including drilling hole as required complete all as specified and directed.
S&F in repair MS clamp made of flat iron size 25 x 6 mm including nuts, bolts and 'S' hook.complete all as specified and directed.
S&F in repair PVC empty transparent lid door Box of Size (600x600x170 mm), IP-65 suitable for fixing existing energy meters with gland complete all as specified and directed.
UNIQUE ENTERPRISE
BISWAS ENTERPRISE
M/S MADAN MOHAN KAKAR
M/S BISWAS AND KUNDU CONSTRUCTION
UNITED BUILDERS
Shree Jayam Enterprises
NIRMAL SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .