Sh Devender Singh IDSE EE
GE North Bathinda Mil Stn
COMPLETION OF INCOMPLETE WORK FOR SPECIAL REPAIR TO BLDG PROVN OF TOILET and BATHROOM PROVN OF VEH SHED AND CERTAIN REV WORKS UNDER AGE BR-V AND AGE EM-V OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
2019_MES_310529_1
8934/NIT-55/19-20
Open Tender
Civil Works
Item Rate
244 days
GE North Bathinda Mil Stn
Class D
9 documents required · 9 mandatory
₹500
GE(N) Bathinda
₹95,000
Yes
17 Feb 2020
30 Dec 2019
5 Feb 2020
30 Dec 2019
3 Feb 2020
13 Jan 2020
30 Dec 2019 - 6 Jan 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.
Surface dressing not exceeding 15cm deep in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing and removing from site all grass, roots and extra soil if any complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Excavation over areas, not exceeding 1.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 1.5mtr and not exceeding 3mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 3mtr and not exceeding 4.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 4.5mtr and not exceeding 6mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Labour for earth filling under floor/plinth, around soakwell, removing, spreading, levelling in layers n exc. 25 cm thick (each layer) consolidating the surface with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge including levelling, well ramming including watering as required and consolidation complete all as specified and directed by Engineer-in-Charge. Note :- Extra Earth obtain form excavation shall be re-used.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Material and labour for Loose filling with broken bricks aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified & directed by Engineer-in- charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 50 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in foundation filling, bed block, for embedded fencing posts, coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor, under paving, plinth protection, under interlocking tiles etc over rammed earth/hard core complete all as specified and as directed by Engineer-in-charge.
Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor, under paving, plinth etc over rammed earth/hard core complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded posts & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material & Labour for 30mm thick cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate as filling in sub base of floors/tiles finished rough complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, hard standing etc, in panels size as directed with provision of expansion joints or glass dividing stripus and surface finished even & smooth with using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge. NOTE : Filling of expansion joints or glass stripus shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing 3mm thick, 38mm wide glass dividing strips inserted in position to the required design/ pattern all as specified & directed by Engineer-in- charge
Material and labour for 100mm thick cement concrete ( 1:2:4), type B-1 using 20 mm graded stone aggregate as in floor, hardstanding/paving/path etc, in panels size as directed with provision of expansion joints and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge. NOTE : Filling of expansion joints shall be measured and paid separately under appropriate item of BOQ.
Material and labour for forming 12mm thick expansion joints (thickness of concrete slab 100mm ) filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'B' including cutting extra concrete as required complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and pigment, prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary form work and using water proofing compound complete all as specified and as directed by Engineer-in- charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for antitermite treatment, treating the bottom and sides of excavation at the rate of 5.0 Litres of emulsion per square metre of surface area complete all as specified & directed by Engineer-in- charge.
Material and labour for antitermite treatment, treating the backfill in contact with foundation at the rate of 7.5 Litres of emulsion per square metre of vertical surface (area of substructure in contact with backfill to be measured) complete all as specified & directed by Engineer-in- charge.
Material and labour for antitermite treatment, treating the top surface of filled earth at the rate of 5.0 Litres of emulsion per square metre complete all as specified & directed by Engineer-in- charge.
Material and labour for antitermite treatment, treating the soil under plinth protection at the rate of 5.0 Litres of emulsion per square metre complete all as specified & directed by Engineer-in- charge.
Material and labour for antitermite treatment, treating the soil along with external perimeter of building at the rate of 2.25 Litres of emulsion per square metre complete all as specified & directed by Engineer-in- charge.
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
Form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Form work to sides of pillars , posts, struts piers, columns and stanchions and similar works rough finished complete all as specified & directed by Engineer-in- charge.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 05cm but not exceeding 10cm wide, rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in beams, cantilevers, bressummers., lintels upto 1.5 mtr span complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Material and labour for mild steel work as in rungs, hooks, rings for steps, handles of manhole covers, hold fast and small articles complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in half brick thick wall using burnt clay bricks (sub class 'B' old size burnt clay bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
Material & labour for continuous brick edging (sub class ‘B’) with width equal to the width of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified. Note : Each row shall be measured and paid separately.
Material & labour for continuous brick edging (sub class ‘B’) with width equal to the depth of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified. Note : Each row shall be measured and paid separately.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of WPC in mortar @ 3% of cement content, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 10mm thick in cement mortar (1:4) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Roughening surfaces of old concrete floor by picking and prepare the surface to receive the screed for tiling, sweeping cleaning and washing down with water to remove dust etc. and brushing neat cement slurry with 3Kg of cement per Sqm before screed complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in vertical surface such as skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (rendering) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular (same as floor tile ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) including making good excess taking down plaster area (above skirting tile ) complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 20 mm thick, Kota stone slab as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 20mm thick, Kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2010 (Part-II), fixed in opening complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face, with particle board core, door to be fixed to frame with 3 Nos extruded brass butt hinges (with S/S hinge pin) B-11 type, bright polished of size 100mm and 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR (Part-I, specifications) & shown in relevant drawing of item No. 8101 and 8103 in SSR (Part-II, rates) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges of size 100mm long x 25mm wide and 2mm thick and 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2010 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2010 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
Taking out old rusted broken window any type and size (glazed and wire guaged) and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified & directed by Engineer-in- charge. Note :- For measurement purpose single unit (sqm) shall be measured and paid i.e. glazed and wire guaged window taking out from same opening
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, 2nd class hard wood (Sal) or any other 2nd class hard wood articles not exceeding 200 cubic centimetre each as small fittings such as shaped door and window stops and the like, including necessary labour etc all as specified & directed by Engineer-in- charge
Supply only 100mm long stainless steel butt hinges heavy duty complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel barrel tower bolt stove enamelled black with bright bolt 200 mm long, fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel barrel tower bolt stove enamelled black with bright bolt 150 mm long, fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 250mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 125mm, oval type stove enamelled black complete all as specified and as directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 150mm, oval type stove enamelled black complete all as specified and as directed by Engineer-in- charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium handle cast type 100mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 125mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing Extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 100mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing aluminium anodised sliding door bolts 150mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge
Supply & fixing 3mm thick sheet glass ordinary quality in squares not exceeding 0.5sqm in each pane (for new door/window) and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 3mm thick figured glass pin head type in squares not exceeding 0.5sqm in each pane for steel or wooden doors/wondows including fixing material complete all as specified and as directed by Engineer-in- charge.
Supply and fixing stainless steel chromium plated pipe 25mm dia, heavy duty, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. complete all as specified & directed by Engineer-in- charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting of existing pipe any dia for insertaion of tee branch as required for connection complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting of existing pipe any dia for insertaion of tee branch as required complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (spun pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door complete all as specified & directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door complete all as specified & directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (suitable Nos i.e interval of 1m ) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 150mm x 150mm size salt glazed stone ware gully traps, square or round mouthed, type 'P' complete all as specified and as directed by Engineer-in- charge.
Material and labour pre-cast RCC (1:2:4) B-1 using 20 mm graded crushed stone aggregates as in pre-cast manholes cover slabs of any thickness size of shape including all necessary form work, finishing concrete surface fair and even and set in CM (1:4) at site as directed complete all as specified and directed by Engineer-in-Charge.
Material and labour cutting into existing manholes/septic tank for connecting new drain 100mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Concrete bed shall be measured and paid for separately)
Material and labour for cement concrete (1:4:8), type D2 using 40mm graded stone aggregate as in bed of drain pipe (SGSW) of size 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in bed of drain pipe of size 100mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Supply & fixing vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests (excluding flushing cistern and flush pipe ) but including CI 'P' or 'S' trap set in and including lime concrete bed for trap and under WC, including PVC pipe upto finished floor level to connect flush pipe, complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing vitreous china wash hand basin white colour, flat back of size 450mm x 300mm excluding taps, but including 32mm waste coupling and waste pipe (LDPE), including new bracket and cutting for and pinning in end of bracket or erecting, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing vitreous china wash hand basin white colour, oval shape, of size 590mm x 420mm x195mm excluding taps, but including 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part CNS-WHT-705 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement vitreous china (white) wash hand basin fancy type including pedestal and 32mm dia waste coupling and including fixing accessories including taking down any type of existing WHB complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part FNS-WHT-40801 (WHB) and FNS-WHT-40301 (Pedestal) of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing in replacement Single Lever Wall Mixer With Provision of Hand Shower, But without Hand Shower including taking down old mixer complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part KUB-35119F of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing Central Hole Basin Mixer with Popup Waste System with 450mm Long braided Hoses, 15mm Cartridge Size complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part KUB-35169FB of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing in replacement single piece WC of size 360x640x690mm with PP seat cover, hinges, fixing accessories set, jet american JS-02, cistern fittings, P-trap 180mm, including connection to drain including taking down old WC with all fittings and low level cistern complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part SLS-WHT-6851P of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in repair Stainless steel CP grating round 125mm dia with or without waste hole complete all as specified and as directed by Engineer-in-charge.
Material and labour 20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 10mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slabincluding cutting as required including cleaning and extra polishing if required complete all as specified and directed by Engineer-in-Charge.
Supply & fixing stainless steel sink made out of 1.00mm thick sheet, kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar to dwarf wall or fixing with cast iron cantilever brackets and connecting union to waste pipe; overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing PTMT tubular towel rail 450mm long between flanges fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by Engineer-in-Charge. Note :- The minimum weight of towel rail is 170 gms.
Supply and fixing MS chromium plated, soap tray approximate size 160mmx160mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engineer-in-Charge.
Supply and fixing bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing stop valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply & fixing cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply and fixing gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 15mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including out let connection complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Dismantling plain or corrugated asbestos cement sheet (corrugated / semi corrugated) including ridges as in roof covering complete all as specified & directed by Engineer-in- charge.
Dismantling wrought iron or mild steel framed work, trusses of any description not otherwise provided for complete all as specified and as directed by engr-in-charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, L- type or J -type hooks or cranked bolts and bitumen washer or fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick including ridge of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or fixed with L type or J type or cranked hooks bolts complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel rolled sections framed work, framed/truss work for fixing GI sheets (design for framing as directed by Engineer-in-charge) and using angle, tee or other section with web and flange cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for mild steel work tubular trusses, poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC (1:2:4), type B-1 using 20mm graded stone aggregate as in coping, roof kerb or mud stops, rounded or chamfered on edges, side of roof sheet & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) and efflorescence from old decorated surface of ceiling by scraping down with wire brush, stell patti, sand papering or by any other mean and preparing surfaces smooth and depression make good by applying average 1.5mm thick layer (one layer) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge) and after that applying two coats of white wash by using paint brush complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) and efflorescence from old decorated surface of walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming down and preparing the surfaces smooth and make good by applying average 3mm thick layer (1.5mm thick each in two layer application ) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge) and sanding the surface by using mechanical sander machine to make the even and smooth upto entire satisfaction of Engineer-in-charge and after that applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) and efflorescence from old decorated surface of walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down with water and preparing the surfaces preparatory to distempering applying Chalk whiting priming coat, and after preparing the surfaces applying two coats of cement base paint as approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing the new plastered surface of walls/pillars/cornices and surfaces smooth and make good by applying average 1.5mm thick layer (one layer) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge) and sanding the surface by using mechanical sander machine to make the even and smooth upto entire satisfaction of Engineer-in-charge and after that applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator, sunken boxes etc but except concealed conduit complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit, but new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall including inner and outer plates suitable for fixing the modular switches, sockets and fan regulator, wiring for light /fan/ bell point controlled by one switch (on indipendent board), fixed with brass screws including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including making good disturbed surfaces of walls by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 180 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 180 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit, but new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall, including inner and outer plates suitable for fixing the modular switches, sockets, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), fixed with brass screws including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including making good disturbed surfaces of walls by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Taking down carefully copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator including rusted/broken concealed conduit, junction and sunken boxes etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (heavy duty), with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, and new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall including inner and outer plates suitable for fixing the modular switches, sockets and fan regulator, wiring for light /fan/ bell point controlled by one switch (on indipendent board), fixed with brass screws including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (Modular switches, sockets, regulator etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 185 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. ((Modular switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 185 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. ((Modular switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (heavy duty), with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, and new Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall including inner and outer plates suitable for fixing the modular switches and sockets, wiring for one socket outlet 15/16 Amp point controlled by one switch (on indipendent board), fixed with brass screws, including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor wire1100 vpolts (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (Modular switches and sockets shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, including frame for covering the switches/socket/regulator, wiring for light /fan/ bell point controlled by one switch (on indipendent board), fixed with brass screws & cup washers including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 189 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 189 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, including frame for covering the switches/socket/regulator, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), fixed with brass screws & cup washers including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type, modular type, fantasy 5/6Amps, single pole, one way fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type, modular type, fantasy, Bell Push, 5/6Amps, single pole, one way fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose modular type, fantasy, 2 in 1, 5 pin 5/6 Amp, flush type fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type, modular type, fantasy, 15/16Amps, single pole, one way fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose modular type, fantasy, 2 in 1, 5 pin 15/16 Amp, flush type fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing stepped (1-4/5) electronic regulator 100 watt (socket size i.e. Two module, step type), modular type fixed on suitable sheet and cover complete all as specified and as directed by Engineer-in-charge. (sheet and cover shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts including LED lamp lumeno of 9 watt suitable for B-22 based holder complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4), electronic Fan regulator (tw module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan complete all as specified by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ).
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor cable continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Taking down old unserviceable DB SPN with MCB MCCB Isolator etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way (12 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 08 Way (08 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 04 Way (04 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing isolator ‘C’ curve suitable for 230/415 volts AC supply, 63 Amps, DP and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Taking down old unserviceable tube light fitting, mirror light fitting and Wall Mount Bracket Light fixture any type and capacity complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable false ceiling light fitting any type and capacity complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable street light fitting with brackets any type and capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1LT8-16 of Crompton / PHOTONULTRA 1213T8SSTL18WLED865SPC and REGALBATTENT 8UPTO1X22WSSBSWH of Havells
Supply and fixing Wall Mount Decorative Bracket Light fixture in cylindrical/doom profile made up of polycarbonate suitable for retrofit LED Lamp (B-22 base) and including LED 7/9 Watt lamp, complete fitting with lamp and all other fixing accessories including electric connection complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part No. DCWL15DF of Crompton/LHDL03160099 of Havelles
Supply and fixing LED light fiting 9/10 watt (100 lumens per watt), appx 1 feet long with in built driver, complete fitting ready to use in all respect with tube rod and all other accessories fitting arrangements including electric connection complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No LCL-07-CDL of Crompton / LHEXARP 7PN 1W009 of Havells
Supply and fixing recessed LED ceiling tile with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness LEDs 36 W (100 lumens per watt), not less than 5700K including connecting electric connection, complete all as specified and as directed by Engineer-in-Charge. Make : Cat part No. LCTLRN-36-F0-CDL of Crompton / BZRSQL 36W GZ1 CW of Bajaj / VENUS NEOHE 2X2PLR 18-42WLED857MOD of Havells
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size complete all as specified and as directed by Engineer-in-charge. Make - Cat part No LSTS-25-CDL of Crompton/ BRLEP 25W LED WH of Bajaj / ENDURA PEARL SL25W LED757 SASYTOPC of Havells
Supply and laying XLPE LT Cable of size 25 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and laying XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and laying XLPE LT Cable of size 10 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling fan 1200 mm sweep single phase, 230 volts 50 Hz double ball bearing energy efficiant having of BEE Hb Plus 5 star rating including electrical connection with round twin core flexible copper multi stranded cable white in colour of suitable size complete all as specified and directed by Engineer-in-Charge Make - Usha / Bajaj / Khaitan / Orient / Crompton
Supply and fixing exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, 04 No bolts grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the fan and making good the disturbed surface as per existing surfaces, fixing the fan by bolts and washers and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar
Disconnecting electric connection and taking down carefully serviceable ceiling fans or Exhaust Fans and keep in safe custudy. After completing the building repair work refixing /hanging the ceiling fan as directed including electric connection with and including new flexible copper wire from ceiling rose/connector to fan connector complete all as specified and as directed by Engineer-in-charge.
Supplying and fixing one twin core cable flat or circular 10Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium Stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by and including insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, complete all as specified and as directed by Engineer-in-charge.
Material & labour for earth continuity conductor or main earthing lead fixed to wall with saddles or chases or buried in ground/drawn in conduit for loop earthing, down condductor etc. or any other indicated situation as required by using 4mm dia GI wire between test point to DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down old unserviceable enclosure complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
G N CONSTRUCTIONS
V K CONTRACTOR
R K GOYAL & COMPANY
M/s Balvinder Singh Engineer and Contractors
SHARDA ENTERPRIES
M/s MITTAL CONSTRUCTIONS
M/s RAMESH KUMAR VERMA CONTRACTORS
M/s Munish Kumar Bansal Contractor
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .