| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAccepted-AOC | ₹9.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹10.2 Cr+₹53.5 L (5.51%)Rejected-Finance | ₹10.2 Cr+₹53.5 L (5.51%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹11.9 Cr+₹2.2 Cr (22.2%)Rejected-Finance B 604 VASUNDHRA APARTMENTS PLOT NO 16 SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹11.9 Cr+₹2.2 Cr (22.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹12.5 Cr+₹2.8 Cr (28.6%)Rejected-Finance | ₹12.5 Cr+₹2.8 Cr (28.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹13.6 Cr+₹3.9 Cr (40.3%)Rejected-Finance | ₹13.6 Cr+₹3.9 Cr (40.3%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹9.9 Cr
EMD Value
₹8.2 L
Closing Date
5 Jun 2023, 6:00 pmClosed
HQ Chief Engineer Delhi Zone Delhi Cantt-10
HQ Chief Engineer Delhi Zone Delhi Cantt-10
CONSTRUCTION OF SWIMMING POOL AT SHANKAR VIHAR AT DELHI CANTT 10
2023_MES_583037_1
CA NO CEDZ/TOKEN-34 of 2022
Open Tender
Civil Works
Lump-sum
545 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹3,000
GE South
₹8.2 L
Yes
8 Jul 2023
4 Mar 2023
7 Jun 2023
4 Mar 2023
5 Jun 2023
22 May 2023
6 Mar 2023 - 13 Mar 2023
Amount
Total amount of Schedule 'A' Section-I (Constructionof Swimming pool & other facilities ) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-II (Site Clearance) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-III (Internal Electric Supply) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-IV (Road,Path & culvert) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-V (Area Drainage) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-VI (Sewage Disposal) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-VII (Compound wall, Gate, Fencing ) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-VIII (External water Supply) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-IX (Internal water Supply) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-X (External Electric Supply) (Ref pre priced Schedule attached seperately)
Total amount of Schedule 'A' Section-XI (Filteration Plant) (Ref pre priced Schedule attached seperately)
Description of Work / Item(s)
Amount
INTERNAL ELECTRIC SUPPLY
S & F Industrial Socket outlet, 20 amps complete all as specified and directed.
S& F10 Watt 3 star (EEL) T shape lamp capable delivering 1000 lumen having luminius efficiency not less than 115 lumen/watt starting time <.5 s CRI>80, PF>0.9,CCT 6500K input voltage range 140-270V input fequency 50-60Hz anb B22 socket complete all as specified and directed by Engineer in Charge
Supply and installation on roof of 1.2HP Pressure Booster Pump with 60L Tank Capacity with provision of suitable size shed cover including PCC/angle iron Work complete with electrical connection all as specified and directed by Engr In charge .
Suply and Fixing 5.0 KVA Inverter with Tubular Inverter Battery (150Ah) complete all as specified and directed by Engr in Charge
AREA DRAINAGE
S&F Factory made steel fibre reinforcement concrete (SFRC) cover of medium duty 70-75mm thick with perforated holes 50mm dia and set in CM 1:6 complete all as specified.
SEWAGE DISPOSAL
M&L for steel fibre reinforced concrete (SFRC) man hole cover mediun duty circular of size 600mm dia and 80mm thick with MS handle all as specified
M & L for RCC Septic tank 50 Users, conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls. Base slab, baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5meter and overall depth of 3 meter complete all as specified and directed.
M & L for soakage well of 2.4M dia and 3.0 M effective depth, excavation in any type of soil, foundation in PCC 1;3;6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC /DWC complete filled with brick bats of size complete all as specified and directed..
EXTERNAL WATER SUPPLY
M& L for cutting of existing pipe line of any size in position of inserting tee,branches of required size complete all as specified and directed by Engineer In Charge
M&L for construction of valve chamber (for sluice valves) 900mmx900mmx900 mm internal size, 100mm thick foundation using PCC 1:4:8, type D2, over 15 cm thick hard core, 20cm thick solid block masonary with blocks cast using PCC 1:3:6, type C 1, set in cement mortar 1:4, 15mm thick plaster to internal surfaces and external surface upto 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement, 1 mm thick MS sheet cover including 50mmx50mmx6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmx6mm flat iron hold fasts, handles, hinges with locking arrangements, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50mtrs complete all as specified and directed.
INTERNAL WATER SUPPLY
S&F counter hand basin of oval shape of size 550X450mm including 32mm dia PVC waste pipe & Cpwaste grating complete as all specified & directed.
S&F brass chromium plated hand shower ( Health faucet) with 8 mm dia 01 m long flexible tube and wall hook all as specified and directed.
S&F tank nipple GI 20mm bore all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel outdoor type of appropriate size and fabricated from 3.15 mm thick CRCA sheet steel with necessary MS angle iron frame work (50X50X6mm), weather proof, vermin proof, suitable rating Aluminium bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labelling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size conforming specification as per IS 5039. The panel shall have IP 57 ingress protection including necessary foundation for mounting all as specified and directed by Enginer in charge”. (Main LT panel outdoor)
Incoming
Outgoing
(i) (i) MCCB 4 pole 415 V breaking cap 25 KA , current rating 250 Amps. - 01 Nos (filteration plant panel) (ii) MCCB 4 pole 63 Amp 16 kA 415V - 01 Nos (Bldg) (iii) MCCB 4 pole 40 Amp 16 kA 415V - 02 Nos (High mast) (iv) MCB 2 pole 40 Amp 10 kA 230V - 01 Nos(Post top lantern) (v) MCB 2 pole 32 Amp 10 kA 230V - 01 Nos(S/L) (vi) Multifunction energy meter (Make: Schneider, L&T, El measure); three phase to Measure V, I, Hz, Kw, KVAr, KVA, PF, PA, I/E, KWH &KVArh, KVAh, Demand & Max Demand - A, Kw & KVA, etc. with inbuilt RS 485/MODBUS Card along with necessary CTs acc class 0.5 ,10 VA Aux Supply: 230 V :- 01 Sets (vii) Timer for Street Light (viii) Busbar: 500 Amps, System Voltage: 415V, 50 Hz, 4W +E
Supply and Installation of IS16444 Part 2 CT Operated Three Phase LT Smart Meter along with transparent polycarbonate box with the following specifications: (a) AC Three Phase Four Wire, Tamper Proof, Static meter of Class 1.0, 415 V, 50 Hz, 05-10 A (b) Meter Should support the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative import energy, cumulative export energy, cumulative apparent energy and frequency, (c) Meter should have built-in Cellular 4G Modem Modem to provide connectivity with the energy management software. MAKE: L&T, Schneider, El Measure(Quoted rate shall deemed to be including of 5 year AMC Charges )
Supply and Fixing Low Tension, Ring Type Current Transformer, Rated Burden 10 VA, Accuracy class 1.0, Frequency 50 Hz. Voltage class 660 volts effectively earthed, 60/5 A to 400/5A (as directed by the engineer) complete all as specified.
S&F HT cable path indicator made of PCC embossed with workds HT cable 11000 volts duly pointed complete all as specified and directed.
Supply and fixing of Koisk box made out of one piece moulded SMC having aluminium bus bars 63 amp single phase and neutral 240 volts with MCB SP 6 amp 10 KA complete all as specified and directed by Engr in Charge
FILTERATION PLANT
Supply, Installation, Testing and Commissioning of Multi Grade Sand Filter- Vessel Dia -3200 mm , Vessel HOS -2175 mm, Filtration Flow Rate- 185 m³/Hr ,Dishend Thickness -10mm, Shell Thickness -8mm , Made of MS internal epoxy painted with collector arms and distributers made ms heavy pipe, frontal piping with 200 mm valve for filtration ,backwash & rinse process . working pressure 2.5 Kg/cm2, desgn pressure - 3.5 kg/cm2 , Test Pressure 5.0 Kg/cm2 confirm to IS-2062. Filter Media Details along with minimum shall be as per details given below [i] Quart Z Pebbles of 1" to 3/4" not less than 100 mm thick layer [ii] Quart Z Pebbles of 3/4" to 1/2" not less than 100 mm thick layer [iii] Quart Z Pebbles of 1/2" to 1/4" not less than 100 mm thick layer [iv] Quart Z Pebbles of 1/4" to 1/10" not less than 100 mm thick layer [v] Quart silica sand of assorted sizes not less than 900 mm thick layer [vi] Back wash arrangement shall be made to facilitate the back washing system [vii] Pressure transmitter -02 Nos along with suitable instrumentation to provide backwash alarm / display [viii] Air vent system with 25 mm pipe with gun metal valve [ix] Pressure relief valve ,nut and bolt and gasket for filter [x] Suitable size of main hole and hand hole. Filter Flow Rate : 185 M³/Hr. Filtration Velocity : 20-25 M³/Hr/M² Diameter : 3200 mm Multi grade filter to be provided as per PS of filtration plant.
Supply, Installation, Testing and Commissioning of Self Priming mono block pumps in CI body, with pre filter in SS 316 as per details in SCH A Notes with matching connection size including vibration eliminating rubber bellows , Bronze Impeller , Motor shaft in Stainless steel AISI 316 with Carbon Ceramic Mechanical seal, Motor speed -1450 RPM, Asynchronous, Two Poles, Continuous Operation F class insulation, protection IP-55, Operating voltage - 380V/ 3 phase, 50HZ . (5 W + 2 SB = 07 Nos) efficiency class- IE-3 Flow Rate: 185 m3/Hr Head: 25 meter Pump shall be mounted on a concrete Foundation Projecting at least 15 cm above finished floor level”
Supply, Installation, Testing and Commissioning of Air Blower with suitable 3 Ph motor IE-3 rated , ISI marked required for filtration unit back wash process of suitable capacity but not less than discharge of 200 Cum /Hr & 0.4 bar pressure at delivery side for backwash of filter units, as given in schedules.
Supply ,install and testing and commissioning of Ozonator for pool capacity 3600 cum disinfection production of Ozone from atmospheric air of capacity 630 gm/hour having ozone concentrations 90-110 gm/cum, Feed Gas -Pure dry oxygen,Moc of ozone cell-SS 316 / Ceramic /PTFE /Quartz / Enamelled, cell cooling - inner electrode-water cooled & outer Electrode -Water Cooled, power supply - Switch mode power supply (SMPS), power amplifier - MOSFET/IGBT Technology, EHT-Ferrite based forced air cooled, Die electric - Precision enamelled / Ceramic/quartz, Enclosure-Finish RAL7035 Structure power coating. Indicator - Power +standby+Ozone ON, Variable control-25%-100% (Internal),Sevice Indicator-Non resettable hour meter,oprating temperature-20 degree C -40 degree C ,mounting /installation- Floor,Line voltage-220V AC /50Hz(180-250V) I phase / III Phase,Operation-automatic Cooling water flow sensor-Magnetic,ORP Controller-Digital Online, Oxygen humidity sensor-Digital Online,Oxygen purity meter-Digital Online,Dissolved ozone monitor-Digital Online,oxygen gas flow sensor-Magnetic/optical flow switch,protection& safety - Line voltage surge and spike, delayed soft start & soft off,Over temperature & protection, over current,under voltage,over voltage,High voltage short circuit, High voltage open circuit, & Enclosure-ULcertified & CE marked,electrical &
Electronics-IP54,Ozone cell- IP 65 , Back flow Preventor-Stainless Steel grade 304+ozone compatible and including Following Accessories Ozone mixing pump-Special ozone compatible stainless Steel -Grade /Carbide Stainless steel grade -316,Ventury-Stainless steel grade -316,static mixer-Stainless steel grade -316,Backflow Preventer-Stainless steel grade -316,Non return valve-Stainless steel grade -316,Skid-Stainless steel grade -304, Control panel-MS Power coated; IP 65 protection, O R P Monitor ± 1000 mV, Oxygen tubing MOC-polyurethane (PU)-03 Meter, Ozone tubing MOC-polyurethane (PU)-03 Meter, Enclosure -Stainless steel grade -304,ozone mass transfer Tanl-Stainless steel grade -316,Cooling System-Cooling tower / water Chiller,Air Dryer -Refrigerant Dryer/ Heatless desiccant ,Ambient ozone monitor-10-1000PPB, dissolved ozone monitor-1.0-20.0 PPM Note :- quoted rate shall be inclusive of providing necessary arrangement for the injection of ozone at the rate of 1 PPM before filter unit for coagulation & 0.2 PPM after filtration for disinfection
Design, supply, Installation, testing and commissioning of Automatic variable chemical dosing system to maintain water quality (PH-7.0 to 7.4, Residual cl -0.5 PPM, TSS < 0.5 NTU) as per details given below : Automatic Variable Chlorination dozing shall be consisting of (a) Preparation tank (500 liters), Agitator for preparation tank, gearbox for agitator (15 RPM), motor for agitator incl connected item, level gauges and level sensors ( SS 316- 02 No’s), digital flow meter and solenoid valve (Acrylic CF-8), (b) transfer pump (PP) of required capacity (c) Dosing tank (500 ltr), level sensors (low level), level gauge (01 No) Solenoid valve (F8) , Dosing pump (1W+1 SB) of required capacity (MOC PTF3) incl motor and PRV for dosing pump, (d) Drain pump of reqd capacity (PP)- 1 No (e) Residual Sensor (0-2 PPM) -01 NO and Flow cell (FC-1) of MOC-Acrylic (f) Rota meter (1/2 inch, MOC-Acrylic), Sampling (needle) valve (1/2 inch; MOC-SS 304) Flow switch (1 inch, MOC – Brass) (g) Control panel comprising of PLC, HMI, VFD Drive-02 Nos, DOL starter (03 No’s), Panel box and other connected accessories, wire (1.5 sqmm/3 core) (h) Piping system consisting of pressure relief valve (1/2)
1. Inch, MOC-PP) 02 Nos, Pressure gauge (0-10 Bar), MOC SS 316), Damper (1/2 inch, MOC- PP) Non return valve (1/2 inch, MOC - PP) Strainer (1/2 inch, MOC-PP) Pipe (1/2 inch, MOC UPVC) Ball valve (1/2 inch, UPVC) 2. Automatic Variable alum dozing system complete with membrane type dosing pump of required capacity, suitable capacity PVC tank and other accessories incl Agitator/Gear box/motor etc required as in above for mixing, alum dosing pump and all parts in contact with the liquid shall be polypropylene, viton, Teflon and PVC. The pump O/P shall have to be automatically regulated through VFD based starter as per Input received through TSS sensor to ensure TSS < 0.5 NTU. The Alum dozing system shall be complete with optimal piping, necessary foot valves with pre filter along with all required connected accessories as per details provided in Automatic chlorine dosing system described in Ser No 01 above to make system fully functional to operate Alum dosing system in Automatic mode.
3. Automatic variable Alkalinity dosing system to maintain PH between the range of 7.0 – 7.4 based on feedback of PH/Alkalinity sensor. The scheme instrumentation & Control system for Alkalinity dozing system shall be similar to Ser No 01 and 02 above. NOTE :- 1. Alkalinity in pool water should be maintained at a level between 80 to 200 mg/l (measured as CaCO3) 2. Quoted rates shall be inclusive of any additional items required to execute the chlorination / Alum dosing / Alkalinity dozing scheme to maintain requisite residual chlorine/PH/TSS in the Swimming Pool.” 3. Standby inspection facility not to be provided in Alum dosing system & Alkalinity dosing system
Supply, Installation, Testing and Commissioning of ABS plastic drain grating plate made out of UV stabilized ABS plastic with suitable supporting frame and of following sizes and having holes of required size for drainout chamber. Size:500 x 500 MM
Supply, Installation, Testing and Commissioning of Flow adjstable ABS Floor Inlet nozzles UV treated with S.S. screws to fit in the 2" UPVC sch 40 industrial grade pipes, Flow Rate- 9-12 m3/hr.
Supply, Installation, Testing and Commissioning of 300 mm wide Overflow Grating made of UV Stabilized PPG in white color. Width 300 mm Height 22 mm with gravity profile.
Supply, Installation, Testing and Commissioning of Stainless Steel 304 ladders, width: 500mm, handrails dia 42 mm stainless steel, non-slip steps provided with anchoring Socket.
(i) 3 Step Standard Ladder
(ii) 4 Step Standard Ladder
(iii) 5 Step Standard Ladder
Supply, Installation, Testing and Commissioning of Hand Rail, 1.2 meter long in Stainless Steel 304
Supply of Trolley mounted suction sweeper kit, (i)Trolly made of MS painted with wheels for smooth movement arrount the deck, (ii) Including self priming, non-clogTrolley mounted suction SP Series pump capacity 3 HP including (iii) Nylon rope & (iv) starter with sutaible size and length of submersible cable complete in all respect (V) 10 Nos. of float complete to support the hose, clips for connection
Supply of Life Boy (30")
Supply of Life Bouy Hook
Supply, Installation, Testing and Commissioning PVCu pressure Pipes Class 5 (10kg/cm2) with plain socket suitable for solvent cement jointing conforming to IS:4985/2000 & fittings conforming to IS 7834/87. Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. The pipes & fittings shall be tested to a pressure of 10 Kg/Sq.cm.Make: Supreme/Astral/Finolex/Prince or equivalent
(i) 63 mm dia
(ii) 160 mm dia
(iii) 200 mm dia
Supply, Installation, Testing and Commissioning of moulded polypropylene / PVC butterfly valve with liner made from Neoprene / EPDM / Nitride / Viton, Flanges as per ASA 150 and pressure rating 10kg / cm2 , lever with locking facility, confirming to BS standard with necessary flanges, zink coated fasteners, nuts and bolts etc. complete all as specified and directed. Make : Aqvastar/ Astral / Finolex/ Ashirvad.
(i) 110 mm dia
(ii) 160 mm dia
(iii) 200 mm dia
(iii) 250 mm dia
Supply, Installation, Testing and Commissioning of moulded polypropylene / PVC non return valve with liner made from Neoprene / EPDM / Nitride / Viton, Flanges as per IS: 778-1957 and IS 5312 and shall be tested to pressure rating 10kg / cm2, confirming to BS standard with necessary flanges, zink coated fasteners, nuts and bolts etc. complete all as specified and directed. Make : Aqvastar/ Astral / Finolex/ Ashirvad.
(i) 200 mm dia
Supply, Installation, Testing and Commissioning of Foot Valve complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes.
(i) 250 mm dia foot valve
Supply, Installation, Testing and Commissioning of following sizes of heavy duty PVC puddle flanges uPVC pipe(10 kg/cm2) fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the water body walls & Slab (As required). To be laid in between the steel reinforcement before RCC. Does not include any civil work. Make: Supreme/Astral/Finolex/Prince or equivalent
(i) 250 mm dia
(ii) 200 mm dia
Supply, installation, testing and commissioning of 450 mm Dia for suction & 400mm dia for delivery line M.S. "c" class Epoxy Coated Suction and Delivery Header including cutting, welding and making provision for different pipe connection. A. Pump Suction Header 8 meter long including provision of 5 Nos. 250 mm dia Suction line from Balancing tank, 2 Nos. 200 mm dia Drain line from swimming pool, 6 nos. of 250 mm dia connection for pump suction. B. Pump Delivery Header 6 meter long including 6 Nos. of 200 mm dia connection for Pump delivery, 5 Nos. of 200 mm dia connection to feed the filters. C. Common Delivery Header 8 meter long for Filters to connect 06 Nos. of 200 mm dia inlet pipes going towards pool with all necessery fittings, flanges, Nut bolts, gesket as required to complet the job.
Supply, laying, testing and commissioning of following size PVC insulated sheathed copper conductor 1100 V grade unarmoured cable with required size of sleeves complete as required.Make: Havells/Polycab/Finolex or equivalent
(i) 4 x 6 sq.mm
(ii) 2 x 4 sq.mm
(ii) 2 x 2.5 sq.mm
Supply, laying, testing and commissioning of following Heavy PVC insulated sheathed copper conductor flexible multistand wire complete as required.Make:Polycab/BAC/AKG or equivalent
(i) 1.5 sq.mm
(ii) 2.5 sq.mm
(iii) 6 sqmm 4 core FRLS multistranded flexible copper cable
(iv) 10 sqmm 4 core FRLS multistranded flexible copper cable
Supply, laying, testing and commissioning of following size Heavy PVC electrical conduit complete as required.
Supply, installation, testing and commissioning of GI perforated Cable Tray
(i) 150mm wide
(ii) 200mm wide
(iii) 300 mm wide
Supply, installation, testing and commissioning of G.I Earthing Wire-8 SWG
Supply, installation, testing and commissioning of MS Structure work (MS Angle, Fastners, Tie Rods) for pipe support and pump footing
Supply, installation, testing and commissioning of Pool under water integral LED Lights, model 14.4 Watt, wall mounted type working on 12 V DC, IP68 complete with built-in driver, including push in connector in 4 pole, including all fixing arrangement in swimming pool wall to accommodate pool light
Supply, Installation, testing and commissioning of ABS white plastic deck box.
Supply, installation, testing and commissioning of 2 core 2.5 sq.mm. PVC insulated copper conductor unarmoured cable Wiring from under water lights to distribution panel Make: Polycab/Havells/Finolex
Supply, installation, testing and commissioning of PVC conduit 20 mm PVC, ISI marked conduits complete with accessories such as bends, junction boxes, pull boxes etc.
Supply, installation, testing and commissioning of Distribution box for under water lights drivers and MCB
Supply, Installation, testing and commissioning of Anchor Fastener , Anchor Bracket SS 304
Supply installation and testing of Diving board with wooden with FRP covering & Fulcrum with supports of 5 .0 mtr long and 0.5 mtr width.
Supply and installation of cable tray made out of stainless steel factory fabricated heavy duty including all fixing material on wall/roof fashner heavy duty nuts, bolts, washers complete all as specified and directed Engr-in-Charge.
Supply, Installation Testing & Commissioning of Indoor type PLC (Programmable Logic Controller) /RTU (Remote terminal Unit) based Automation, Protection Panel for Pump, Valve operation, energy monitoring, backwash alarm generation, treated water flow regulation of main & diving pool, monitoring of water quality of swimming pool, priming arrangement of with feature of wireless Dual SIM Card based communication, suitable for control and monitoring of up to 7 Nos. Centrifugal Pumps, 7 Nos. Energy Meters, 2 Nos. Motorized Butterfly Valves, 01 Nos Ultrasonic level sensor, 07 Nos. Solenoid Priming Valves, 7 Nos. Solenoid Air Release Valves, 10 Nos. pressure transmitters, 07 Nos. electromagnetic Flow Meters. The panel should be of minimum size 1200 X 950 X 300 mm front opening type, fabricated from 2.00 mm thick CRCA Sheet & mounting channel 40x40x5mm made out of Angle iron with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size. The Panel should have the following functionalities complete all as specified and directed:- (a) Water Level (balancing tank), Flow monitring from each filter & treated water flow regulation of main, diving pool, Toddler pool/ Children pool & Display feature (b) Automatic Pump On/Off, Automatic Priming and Air Release( if reqd) (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps (e) Auto Change Over In Case of Pump Failure (f) Single Phasing Prevention, phase sequence corrector (g) Online UPS with battery system of adequate capacity. (h) Manual Mode Operation (all connected sub systems at filtration plant) from the RTU/ PLC based Control Panel. (j) Additionally the panel should have following specifications:- (i). Discrete Input Logic: - Sink/Source, Discrete Output Logic: - Positive Logic(Source).
(ii). Should have suitable No. of Discrete Input conforming to IEC 61131-2 Type - 1 & Discrete Output: - Relay/Transistor (iii). Protocol supported : isolated serial link: Modbus master/slave and DNP 3.0 (iv). Standard supported :- ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007 (v) Web Services: - Integrated Web Server (vi) Should have 02 Nos. isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/ 100BASE-TX. Should be able to latch with minimum number of Slave: - 64 Modbus TCP, & adequate DNP3.0 master/ slaves. (vii) RTU/ PLC shall be based on ARM based Controller with at least 600GHz clock frequency and 512MB RAM (viii) PLC/RTU shall be certified by NABL for electromagnetic compactability and radio distrubance standards as per CISPR22, IEC 61000-4-2:2008, IEC61000-4-3:2010, capable of sending data to multiple route and on precise location. (ix) Contractor shall consider in quoted rates for any changes in logic within 5 years of installation as per requirement of department. (x) There shall be 01 No. HMI - 7" Graphical Touch screen display with following specifications : (xi) 01 No. RS 485 and 01 No. USB port & Ethernet port (xii) Serial multilink, USB downloading port & Ethernet port (xiii) Support external data storage on a USB memory stick for storing production data and backing up applications. (ixx) 01 No. SMPS of 6.5A or above rating (to be decided as per panel design by the contractor) as suitable according to panel design. (xx) Suitable No. of interposing relays of 220VAC or 24VDC coil rating and 4A contact rating. (xxi) Suitable No. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.
S& F electromagnetic type flow meter suitable for 200 mm bore pipe, flow range : 0 to 200 cu .mtr/hr , liquid clean /semi clean water , wire length min 10 mtr, with IP-67 protection , 1.4 KV isolation, accuracy of less than ± 0.3% of MV , lineraity of 0.5 % of MV, mounting in horizontel position, water pressure: Nominal pressure upto 200 KPa, should account for the water hammer depending on the valve closure time, current output:4 to 20 mA,local indicatin through LCD disolay and RS 485 Modbus RTU communication protocol, capable of working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade and Humidity upto 95% with response time of less than 1 Sec,working on 90-250V AC,50Hz, Body and flanged material SS 304 or higher grade steel electrode material standard hastelloy, including necessary welding work, cutting of existing MS/DI/CI/GI piupe line and inserting new XX mm bore MS pipe with necessary MS bends and straight pipe upto 06 mtr and connecting with existing pipe line with necessary flanged , nut,bolts,gasket and DI/CI specials complete all as specified and directed.) the flow meter must have inretface with computer / laptop & should be able to monitor & control from computer,quoted rate shaa also include necessary Hardware/software) Make:Krohne, omega, onicon, E&H mgt, ABB, Siemens.
Supply, installation, testing and commissioning of ultra sonic level sensor with following specifications : Rust proof, Maintenance free suitable for up to 6 meter water level depth of OHTs/ U/G sump, with dead band of less than 0.6 metre, IP67 protection, accuracy of 0.25% of F.S and 4-20mA current output, RS485 Modbus RTU communication protocol, No of wires 4 wire, Beam angle less than 7.5 degree. Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply. Non display type, in built temperature & voltage variation compensation, vertical type mounting on top of OHTs / Sump, suitable for measuring water / waste water in Sump / OHT, with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed. Make : ABB, Endress+Hauser Mgt, Siemens, Krohne, Pepperl +Fuchs, continental, Vega grieshaber, Hans Turck, Gems sensors, Omega engineering, Keyence, Texas instruments, Migatron, Honeywell (Scope of work include all accessories required for the correct operation of the sensor)
Supply, installation, testing and commissioning of smart pressure transmitter based on micro capacitance Silicon sensor, smart microprocessor (2 core), output 4-20mA DC with digital communication RS485 Modbus RTU communication protocol, Housing Die cast aluminium alloy finished with polyester coating , protection class – IP68, welted parts - SS316, Flange / Diaphragm material SS316 mounting bracket : SS, turndown ratio – 100:1 & all as per tech specification.
Supply, installation, testing and commissioning of motor actuated butterfly valves with the following specification including all accessories as required complete all as specified and directed. Butterfly valve specification :- (a) Valve size 200 mm (b) Design pressure : PN16 (c) Operating angle : 90 degree (d) MoC : body & disc-CI, body seat ring : SS AISI 410 (e) Design & manufacturing standard : IS :13095 / BS EN 593 (BS 5155) (f) Low friction self lubricated sleeve type bearings Actuator Specification :- (i) Enclosure : IP68 watertight (ii) Power supply : 230V AC, 50Hz / 400V AC (3 Phase), 50 Hz / 24V DC (iii) Travel angle : 90 + 5 degree (iv) Casing Material : Aluminium Alloy, Dry power polyester coated (v) Motor : totally enclosed non ventilating type, insulation – IEC 85 Class F (155 degree Celsius), totally separated from lubricant filled gearing of Actuator, protected by 3 monitoring device embedded in motor winding.
(vi) Limit Switches : 2 x open / 2 x close, SPDT, 230V AC (vii) Space heater : 230V AC anti condensation; Ambient temp: - 20 to 60 degree Celsius (viii) Hand wheel for manual operation (ix) Hall sensor based absolute encoder for limit sensing with a resolution of 3 degree or better in case of power failure, Actuator shall not be equipped with battery; Make : Rotork Plc / Festo AG & Co. KG / Pentair Plc / Honey well / Emerson electric / Cameron international corporation / Marsh automation Pvt Ltd / Sdtrok / Auma actuators / Johnson Valves / Kirloskar (g) Electric actuators shall have provision for partial opening of valve as per requirement to ensure desired discharge as per requirement of pool (h) RS 485 Modbus RTU communication protocol.
Maintenance and Operation
Maintenance and operation of swimming pool at Shankar Vihar in two shifts prescribed as follows:- (a) First shift:- From 0600 hrs to 1400 hrs. FGM (Filtter General Mechanic, Skilled) - 01 No (Shift of 8 hrs) (b) Second Shift:- From 1400 hrs to 2200 hrs. FGM (Filtter General Mechanic, Skilled) - 01 No (Shift of 8 hrs) Details of equipments at swimming pool installation:- (a) Cetrifugal pump (b) Pressure sand filter (c) Chemical dosing plant Task:- (a) Maintenance of water in the water balancing tank. (b) Back washing and operation of plant. (c) Cleaning /washing the swimming pool complete before and after every season or as per requirement. (d) Maintaining of whole installation and surrounding area's cleaningness. (e) Cleaning of swimming pool including operation of suction sweeper during operation/non operation period including removing of flotting dust, cleaning of wall of swimming dust catcher every day before starting the pool operation and on nonswimming days throughly to maintain hygienically using shitable machineries in working condition including greasing , oiling complete all as directed. (f) Contractor will also ensure proper working of swimming pool and filteration plant. Working time will be as per direction of Engr-in-Charge from time to time. (g) Contractor will maintain daily water test report register with testing kit (Rate of test kit shall be deemed included int the quoted rate) (h) Contractor will maintain the swimming pool in such a way that swimming pool water always remain crystal clear, hygienic and limped by maintaining water PH level in between 7.2 to 8.0 and idle chlorine level between 0.20 to 0.50.
Supplying and mixing of alum sulphate in swimming pool installed complete all as specified and directed by Engr-in-Charge.
Supplying and mixing of soda ash in swimming pool installed complete all as specified and directed by Engr-in-Charge.
Supplying and mixing of TCC A90 in swimming pool installed complete all as specified and directed by Engr-in-Charge.
Supplying and mixing of copper suphate in swimming pool installed complete all as specified and directed by Engr-in-Charge.
M/s Innovative Coolings and Constructions
AMIT ASSOCIATES
Pooja Singla Builders And Engineers Pvt Ltd
India Guniting Corporation
KRISHNA SAHIL CONSTRUCTIONS PVT LTD
A K BANSAL AND CO
Pooja Singla Builders And Engineers Pvt Ltd
AMIT ASSOCIATES
India Guniting Corporation
KRISHNA SAHIL CONSTRUCTIONS PVT LTD
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .