Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC 1st Lowest and reasonable | |
| 2 | L2₹13.0 L+₹2.0 L (18.6%)Rejected-AOC | L2 | Rejected-AOC 2nd Lowest | |
| 3 | L3₹13.7 L+₹2.7 L (24.9%)Rejected-AOC | L3 | Rejected-AOC 3rd Lowest | |
| 4 | L4₹14.7 L+₹3.7 L (34.0%)Rejected-AOC | L4 | Rejected-AOC 4th Lowest | |
| 5 | L5₹15.0 L+₹4.1 L (37.2%)Rejected-AOC | L5 | Rejected-AOC 5th Lowest |
Tender Value
Refer Docs
EMD Value
₹43,860
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Raiwala
AGE(I) Raiwala cantt
MANNING AND OPERATION OF POWER HOUSE EXTERNAL ELECTRIC SUPPLY AT RAIWALA AND NARENDRA NAGAR UNDER AGE(I) RAIWALA
2021_MES_415905_4
8853/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Raiwala and Narender Nagar
As per tender documents
8 documents required · 8 mandatory
₹500
AGE(I) Raiwala
₹43,860
Yes
6 Apr 2021
8 Mar 2021
24 Mar 2021
8 Mar 2021
22 Mar 2021
10 Mar 2021
60 days
Amount
Providing services for daily running , maintenance and operation for 11 KV MRS RAIWALA with trained / qualified manpower given below with working experience upto HT 11 KV supply network for proper electric supply to users as directed by Engineer in charge as per following requirement :- (a) The 11 KV MRS shall be operated round the clock with One Electrician in each shift for three shifts in a day including holidays & Sundays. (b) Proper recording of all operating parameter in the prescribed log book/Register shall bedone all as directed by Engr-in-Charge. (c) The electrician employed shall be ITI qualified with minimum of 05 years relevant experience. (d) The installation including following :- (i) 11 KV VCBs - 04 Nos (ii) Transformer 11/0.433 KV, 315 KVA (iii) LT panel (iv) Two pole structure (v) UPCL metering system
Note : (i) The manning includes routine maintenance of all installed panel / machinery, replacing HT fuseof HT poles,replacing jumpers of almn conductor, resetting relay after tripping etc any material required for HT fuse, grease/ lubricant, insulation tape, aluminium conductor, nut bolts,washers for minor repair in side MRS campus shall be provided by contractor. The quoted rates are inclusive of such provision. (ii) Cleaning of complete MRS building and premises, all installed machinery, panels and gardening, sweeping of area and toilets as per directed. (iii) The electrician deployed shal be well conversant with 11 KV switch gears and shall be responsible for any normal maintenance of installations (iv) The rate also includes / regular greasing and oiling of mechanical part of switch gears, tightening of all termination points, checking all connections and tightening any loose connections, insulationg any exposed conductor, (v) The operators shall be responsible for the complete security of the MRS installation including necessary watch and ward etc. (vi) Successful operation of the plant to the entire satisfaction of Engr-in-charge/AGE (I) shall be sole responsibility of contractor.
(vii) Shift member in each shift shall be equipped with mobile phone, NO of Mob Phone be displayed at MRS and AGE E&M office , JE incharge. (viii) The recovery from the contractor shall be made @ of Rs 1000/- Per shift in case of non operation of installation due to absent of electrician of the contractor or in proper rutine mainetnance. (ix) All shift members should maintain healthy decorum and shall be fully conversant with the any visiting officer and office staff. The should have proper uniform with MES logo and name plate on uniform dress as approved by AGE (I) (x) Operator will be responsible for timely information to AGE E&M and JE incharge for any fault beyond his control in installed machinery. (xi) Operator will immediately inform to Engr in charge if recorded demand shoots about 95% of CMD (xii) Operator will immediately inform to Engr in charge if recorded Power factor come down from 95%. (xiii) Operator will strictly follow the shut down procedure explained by Engr in charge and maintain a record for this purpose as directed by engr in charge (xiv) All stationery required for log sheet and attendence register / duty roster, Maintain register, Shut down register, Handing Taking register at MRS shall be provided by contractor
(xv) All protective gadgets shall be provided by the contractor (xvi) All T&P required shall be provided by the contractor (xvii) During any shut down / Break down from UPCL, operator will contact telephonically with UPCL and will give feed back to JE/AGE E&M (xviii) Proper Handing Taking of Installation and installed items be done between JE incharge and Contractor, before commencement of work and after completion of work duly countersigned by Engr in charge (xix) Payment be done through bank account of operator and monthly evidence be provided to department by the contractor in this regards (xx) All operators shall be insured for risk cover, ESI/EPF be maintained by the contractor as per existing rules of Govt of India
Providing services for daily running , maintenance and operation for 11 KV MRS NARENDRA NAGAR with trained / qualified manpower given below with working experience upto HT 11 KV supply network for proper electric supply to users as directed by Engineer in charge as per following requirement :- (a) The 11 KV MRS shall be operated with One electrician in each shift for Two shifts in a day from 0600 hrs to 2200 hrs including holidays & Sundays. (b) Proper recording of all operating parameter in the prescribed log book/Register shall be done all as directed by Engr-in-Charge. (c) The electrician employed shall be ITI qualified with minimum of 05 years relevant experience. (d) The installation including following :- (i) 11 KV VCBs - 04 Nos (ii) Transformer 11/0.433 KV, 200 KVA (iii) LT panel (iv) Two pole structure (v) UPCL metering system
Note : (i) The manning includes routine maintenance of all installed panel / machinery, replacing HT fuseof HT poles,replacing jumpers of aluminium conductor, resetting relay after tripping etc any material required for HT fuse, grease/ lubricant, insulation tape, aluninium conductor, nut bolts,washers for minor repair in side MRS campus shall be provided by contractor. The quoted rates are inclusive of such provision. (ii) Cleaning of complete MRS building and premises, all installed machinery, panels and gardening, sweeping of area and toilets as per directed. (iii) The electrician deployed shall be well conversant with 11 KV switch gears and shall be responsible for any normal maintenance of installations (iv) The rate also includes / regular greasing and oiling of mechanical part of switch gears, tightening of all termination points, checking all connections and tightening any loose connections, insulationg any exposed conductor, (v) The operatiors shall be responsible for the complete security of the MRS installation including necessary watch and ward etc. (vi) Successful operation of the plant to the entire satisfaction of Engr-in-charge/GE shall be sole responsibility of contractor.
(vii) Shift member in each shift shal be equipped with mobile phone, NO of Mob Phone be displayed at MRS and AGE E&M office , JE incharge. (viii) The recovery from the contractor shall be made @ of Rs 1000/- Per shift in case of non operation of installation due to absent of electrician of the contractor or in proper rutine mainetnance. (ix) All shift mambers should maintain healthy decorum and shall be fully conversant with the any visiting officer and office staff. The should have proper uniform with MES logo and name plate on uniform dress as approved by AGE (I) (x) Operator will be responasble for timely information to AGE E&M and JE incharge for any fault beyound his control in installed machinery. (xi) Operator will immediately inform to Engr in charge if recorded demand shoots about 95% of CMD (xii) Operator will immediately inform to Engr in charge if recorded Power factor come down from 95%. (xiii) Operator will strictly follow the shut down procedure explained by Engr in charge and maintain a record for this purpose as directed by engr in charge (xiv) All stationery required for log sheet and attendence register / duty roster, Maintenance register, Shut down register, Handing Taking register at MRS shall be provided by contractor
(xv) All protactive gagets shall be provided by the contractor (xvi) All T&P required shall be provided by the contractor (xvii) During any shut down / Break down from UPCL, operator will contact telephonically with UPCL and will give feed back to AGE E&M (xviii) Proper Handing Taking of Installation and installed items be done between JE incharge and Contractor, before commencement of work and after compeation of work duly countersigned by Engr in charge (xix) Payment be done through bank account of operator and monthly evidence be provided to department by the contractor in this regards (xx) All operators shall be insured for risk cover, ESI/EPF be maintained by the contractor as per existing rules of Govt of India
janta tradrers
Sanjay Associates
R P G ELECTRONIC REGD
DOON DIESEL SALES AND SERVICE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .