| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 CrAccepted-AOC 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹9.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹10.1 Cr+₹65.6 L (6.95%)Rejected-Finance | ₹10.1 Cr+₹65.6 L (6.95%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹11.7 Cr+₹2.3 Cr (24.3%)Rejected-Finance | ₹11.7 Cr+₹2.3 Cr (24.3%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹11.9 Cr+₹2.4 Cr (25.9%)Rejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹11.9 Cr+₹2.4 Cr (25.9%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹12.2 Cr+₹2.8 Cr (29.4%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹12.2 Cr+₹2.8 Cr (29.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹7.3 L
Closing Date
3 Aug 2023, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
PROVN OF DEFICIENT WARDS FOR ARMY HOSPITAL (RR) UNDER GE (E/M) RR HOSPITAL DELHI CANTT-10
2023_MES_574438_1
CA NO CEDZ/TOKEN-22 of 2022
Open Tender
Civil Works
Lump-sum
455 days
Delhi Cantt
MES contractor enlisted in MES under class S cat a i having deposited Standing Security of Rs 1100000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE (E/M) (RR) HOSPITAL DELHI CANTT-10
₹7.3 L
Yes
22 Aug 2023
11 Jan 2023
5 Aug 2023
1 Jun 2023
3 Aug 2023
24 Jul 2023
11 Jan 2023 - 6 Feb 2023
Amount
INTERNAL WATER SUPPLY S&F 3-in-1 wall mixer with L band provision for overhead Shower with 115mm long bend pipe on upperside, connecting legs & wall flanges made of cast copper alloy, chromium plated fancy type, complete all as specified & directed
EXTERNAL ELECTRIC SUPPLY Supply, installation, testing and commissioning factory made (CPRI approved) LT feeder pillar box, outdoor type, powder coated, weather, dust & vermin proof made out of 3.15 mm thick CRCA MS sheet front and back openable door, with suitable size angle iron frame and locking arrangement including suitable working space in bus bar chamber, cable box chamber with cable alley suitable for 3 phase 4 wire system, 415V, 50 Hz, AC supply including 600 Amp aluminium bus bar with PVC sleeves/ tape RYB colours for phases identification, including all bus bar shall be extend upto cable box chamber fixed on fiber insulation for RYB &neutral to all out going cable and fixed on raised PCC platform with PCC 1:2:4, type B1 (20mm graded aggregate) with control / internal wiring with PVC insulated copper conductor FRLS cable of suitable size. The scope of work includes the following:-
(a) INCOMING
(i) Communicable MCCB, 4 Pole, 415 volts, AC, 50 Hz, 400 Amps, 50 kA, adjustable microprocessor release type - 01 No
(ii) Communicable Digital multifunction meter with all parameter with suitable capacity of 03 Nos CT's - 01 No
(iii) LED Indication lamp with toggle switch RYB for phase indication - 01 Set of three
(b) OUTGOING
(i) MCCB, 4 Pole, 415 volts, AC, 50 Hz, 125 Amps, 16 kA, adjustable Thermal magnetic release - 5Nos (Bldg DB – 04Nos, Spare MCCB- 01Nos)
(ii) MCCB, 4 Pole, 415 volts, AC, 50 Hz, 100 Amps, 16 kA, adjustable Thermal magnetic release -01Nos (Fire pump - 01 No)
(ii) MCCB, 4 Pole, 415 volts, AC, 50 Hz, 63 Amps, 16 kA, adjustable Thermal magnetic release -03 Nos(Lift 8 & 15 Passenger- 02 Nos&Spare - 01 No)
FIRE FIGHTING & FIRE ALARM SYSTEM Providing and fixing fire hose cabinet of size 1000 x 1650mm weather proof fabricated from 18 SWG MS sheet with double front central opening partially glazed with 4mm thick glass with locking arrangement duly painted suitable to house incl 2x15Mtr (two length) of RRL house and hose reel drum with coupling, Branch pipe one firemans axe, first aid hose reel and hydrant outlet complete all as specified & directed
M&L for road cutting of average size 0.30m x 0.60 m for laying of MS pipe, incl excavation, returning filling in, spreading, levelling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix capeting 25mm thick using ready mix patch repair work, complete all as specified & directed.
M&L of 2 core FRLS PVC insulated, unsheathed, multi stranded, copper conductor cable of size 1.5 Sqmm complete all as specified and directed
Supplying, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following:
(a) Horizontal end suction centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase 50 Hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, B855CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 70 m.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65 % of the rated head
(b) Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation of 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator.
(c) Common base plate for (a) and (b) of MS
(d) Suitable cement concrete foundation duly plastered with anti vibration pad complete as required.
Supplying, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant pump suitable for automatic operation comprising of the following:
(a) Horizontal end suction centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase 50 Hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced ) and stainless steel shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 70m and coforming to IS-12469 : 1988.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65 % of the rated head
(b) Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply, for the above pump with synchronous speed of 1450 RPM, conforming to IP 55 protection & class F insulation.
(c) Common base plate for (a) and (b) of MS
(d) Suitable cement concrete foundation duly plastered with anti vibration pad complete as required.
Supply, installation, testing and commissioning of jockey pump comprising of the following :-
(a) Vertical, multistage Centrifugal pump suitable for operation and 415 volts + 6%, 3 Phase, 50 Hz AC supply. The installation shall be complete with flexible coupling, coupling guard pressure gauge suitable for delivering 180 LPM at a head of 70 mtr.
(b) Squirrel cage induction motor TEFC type for operation on 415 volts, 3 Phase, 50 Hz, AC supply for the above pump with a synchronous speed of 2900 RPM, suitable for automatic operations.
(c) Common base frame for pump & motor.
(d) Suitable cement concrete foundation duly plastered with anti vibration pad complete as required.
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated alluminum bus bar 160 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 2.5 Sqmm. The scope of work includes the following
INCOMING
(a) MCCB 4 Pole 415 volts grade 150 Amps rating adjustable type and 10 KA rupturing capacity -01 No
(c) Indicating lamp-01 set of three
OUTGOING
(a) MCCB 4 Pole 415 volts grade 100 Amps rating and 10 KA rupturing capacity -01 No ( for F/ F pump)
(b) MCCB 3 Pole 415 volts grade 32 Amps rating and 10 KA rupturing capacity -01 No ( For Jockey pump)
(c) MCCB 3 Pole 415 volts grade 32 Amps rating and 10 KA rupturing capacity -01 No ( Spare)
(e) Two Nos Star Delta starter complete with contactors ,relay, phase preventer etc capacity 50 HP - 01 No. and 7.5 HP - 01 No with auto/manual switch for automatic and manual operation.
(f) Annunciation window consisting of indication for each fire sprinkler zone and should be interlocked with water flow switch installed in main distribution line of each sprinkler zone including electronic hooter.
Note: 1. The panel should have arrangement for interlocking pressure switches to starter for automatic operation. For automatic control any additional device or relays required is deemed to be included in quoted rates.
2. The control system shall be designed to provide following sequence: (a) The jockey pump shall start when pressure of system fall about 0.35 kgf/cm2 below normal system pressure and shut down when system pressure is reached. (b) The main fire pump shall start when pressure falls suddenly about 1 kgf/cm2 below normal system pressure and no pump shall start when main fire pump is running. (c) In case of power failure if system pressure falls suddenly about 1 kgf/cm2 below normal system pressure diesel pump shall start within 5 sec of power failure.
UPS Supply, Installation, testing and commissioning of 30 KVA/27 KW 3-Phase Input / 3- Phase Output UPS (Uninterruptible power supply), true online configuration with double conversion technology,DSP based technology with reduction in electronic components, Fully rated power (KVA=0.9KW) for maximum power availability, Possibility of enhancing UPS capacity / redundancy by operating UPS in N+X Parallel Redundant Configuration(PRS), Capability of Independent battery bank operation of the UPS when operated in PRS, UPS should be designed at Rated PF of 0.9 i.e. 30KVA /27KW UPS rating, Dual Input design, UPS should have IGBT topology for inverter, Inbuilt Isolation K Rated Transformer with SMF batteries including suitable size of steel battery rack including inter connecting cablecomplete all as specified and directed by Engineer -in-charge. It must consist the following:- (a) INPUT : Three phase AC, Four wire system, input Voltage tolerance + 20%, frequency range45-65 Hz, input power factor- 0.9,current harmonic distortion (ITHD) < 3 - 5%, compatibility to genset supply required,input protection- through 1P MCB at input of UPS suitable for full rated capacity of UPS (b) OUTPUT : Output voltage - 220/380V,230/400V,240/415V (3Phase 4 Wire), output voltage regulation +1 Nominal output frequency- 50/60 +0.05 Hz, output voltage distortion (THDu) -<2% for linear load, crest factor is 3:1, output wave form- pure sine wave, output protection- electronic protection. (c) Transient responsefor dynamic regulation for 10% to 90% step linear load is + 5% and transient recovery to steady state condition after 10% to 90% step linear load is less than 1 cycle. (d) Transfer Time (Mode of operation) shall be Zero ms from Mains mode to Battery Mode and Zero ms from Battery Mode to Mains mode. Transfer Time (Inverter to Bypass / Bypass to Inverter)<2ms (Synchronized Mode). (e) Automatic & Bi-directional static by-pass (In-built) shall be Bypass To Inverter ±10 % (Rated Voltage) Inverter To Bypass ±7 % (Rated Voltage). UPS should have manual maintenance bypass. High overload capability of static bypass (12 times for 10 milliseconds and 10 times for 100 milliseconds)
(f) Overall Efficiency(At Nominal Voltage & Resistive Load up to kW rating of UPS) (AC to AC) - Online (DoubleConversion) >93% and Overall Efficiency(AC to AC)ECO Mode (Bypass feeding the load undernormal conditions)> 98% (g) Inverter Overload capacity: 101-110%: 60min; 111-125% : 10min; 126% - ≤150%: 1 minute; >150%: 1 second (h) Display Panel (In-build LC Display & LED ): LCD shall have measurements for Input: Voltage / Frequency,Bypass: Voltage / Frequency,Output: Voltage / frequency,Battery: Remaining time / Battery Level Indicator,Load: Percentage / Load Level Indicator,Battery Voltage Capacity/Status/Test Result,System Date/Time Setting,Current Time,PFC Fuse Open,Battery Temperature Too High,Battery OverCharge,Battery Out of Date,INV Short Circuit,Output Breaker Off,kVA,kW,output current,Battery current. LCD shall haveFault Indication for Main Input Sequence Fault,Power Module General Fault,BatteryGround Fault,Bypass Static Switch Fault,Parallel Fault,System General Fault,Provide Bypass O/P Even If UPS Fault. Indications (LED)Normal-Green/Battery-Orange/Bypass-Green/Fault-Red (j) Audible Alarms for Battery Low beep / DC Fault beep/ UPS Overload beep/ o/p short ckt fault beep/ Shutdown beep (k) 30 min (26520VAH) battery backup with 384V battery bank voltage by 32 Nosof Sealed Maintenance Free (SMF) Battery, 70AH, 12 Volt with minimum three year replacement warranty and space saving MS steel open racks battery housing complete with interconnectors. Make: Exide/Amara Raja/ HBL. The charger shall be Constant Current/Constant Voltage type and should be able todeliver charging current equivalent to 10% of Battery Ah rating offered. (l) Operating Temperature - 0℃ ~ 40℃, Storage Temperature-20℃ ~ 40℃,Operating Humidity< 95%, Operating Altitude - 0 to 1000m, Type of Cooling-Forced Air, Noise level: < 65 DbA measured at 1 meter distance, Relaibility- MTBF greater than 100000 hours
(m) INTERFACES :RS2323 Port should be provided as standard in the UPS. However there should be provision for USB/SNMP port also in the UPS.Provide both onsite & remote EPO to shutdown UPS when emergency situation happens.REPO(Remote Emergency Power OFF) Port with a user-supplied switch shall be provided.UPS should be capable to carry out self test of Rectifier / Charger/Battery & Inverter module during start-up (n) Manufacturer shall have the certificationQMS: As per ISO 9001: 2015, EMS: As per ISO 14001: 2015, OSHAS: As per ISO 45001:2018 Product Safety Certifications (Mandatory) ESD:IEC 62040-1-2 General & safety requirement ;IEC EN62040-2 EMC requirements;IEC EN62040-3 Operating requirements Note:- The contractor shall submit 02 year replacement warranty of each UPS completeincluding inspection upto site service supportfromOEM and period shall be counted from the next day of actual date of completion of project.
(a) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per IS (efficiency class equivalent to IE 2) and operating gearless box with independent main sheave rim.
(b) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(c) Micro processor based VVVF type main controller with closed loop system.
(d) Car position indicator in car all fixture in SS face plate (both insided/out-side). All buttons should be with brail marking and luminous.
(e) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking & other accessories.
(f) Inbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside car to alert the persons trapped inside that they are being rescued.
(g) Provision of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology. Grooved Belt and alongwith belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator nearest landing.
(h) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(j) Door sensor not less than 74 beam, 2D infra red full length
(k) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(l) Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown.
(m) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(n) A three Pin plug socket with switch for hand lamp shall be fitted on top of the lift car for use by person working there on.
(o) Provn of 40 mm SS handrail on three side of the lift.
(p) Provn of transparent space for highlights the imp instructions and Mobile Nos.
(q) Provn of RCCB/RCBO in SS enclosure.
All as per srl item No.12 here-in-before but capacity 15 passengers (1020 Kg) at a speed of 0.5 m/sec to serve upto 5 floors (G+4 floors) and size 1000 x 2400 mm suitable for hospital stretcher.
MGPS & SIGN BOARD Supply, Installation, Testing & Commissioning (SITC) of BSI Kite Mark Certified Copper Pipes : It should be confirm and meets with BS:EN:13348:2016 copper pipes: All medical grade degreased copper pipes. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW 024A ( Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2016, Degreasing of pipe shall be such that there is less than 20 mg / m2 (0.002 mg / cm2) of hydrocarbons on the degreased surface when tested by the method specified BS: EN: 13348:2016 complete all as specified and directed. (a) SITC of BSI Kite Mark Certified Copper Pipes of 42mm.
(b) SITC of BSI Kite Mark Certified Copper Pipes of 28mm.
(c) SITC of BSI Kite Mark Certified Copper Pipes of 22mm.
(d) SITC of BSI Kite Mark Certified Copper Pipes of 15mm.
SITC of Line Ball Valves: It should fully complies and meets with the requirements of the HTM 02-01 / NFPA -99 Recomendations All ball valves as per BS 1057 are rated at 400 psig, as well as full vacuum ( 29.9" Hg). Valves go from full ON to full OFF by turning the vinyl-gripped valve handle 90 ° Locking-type handles may be ordered separately when required. Copper tubing is factory installed to help prevent valve seat damage during soldering. Main and riser valves are not required to be installed in a box unless specially noted or required. It should be duly CE markd with 4 digit notified body number or UL /ETL listed whereever applicable. All line valves - Supplied with a mechanism to enable the unit to be locked in the fully closed or fully open position complete all as specified and directed (a) SITC of Line Ball Valves of 42 mm size with pipe stub on both sides
(b) SITC of Line Ball Valves of 28 mm with pipe stub on both sides
(c) SITC of Line Ball Valves of 22 mm with pipe stub on both sides
(d) SITC of Line Ball Valves of 15 mm with pipe stub on both sides
SITC of Area Valve Service Units for 3 Service : It should fully complies and meets with the requirements of the HTM 02-01 or NFPA 99. Bidder must submitted third party CE certification I UL listed along with tender documents. Self attested certificate not valid. Adopter having opening by quarter turn of handle. The valve should be pneumatically tested as per BSEN 1057 for twice the working pressure and degreased for medical gas service before supply. Valve boxes should be equipped with components for shutting off and supervising individual /parts of central systems in hospital, laboratories and the like. They should be allowed the ward staff to allow isolating of the areas for maintenance and repair work. The pressure monitoring of the distribution system is done by pressure gauges. In case of emergency the door can be glass break opened or by un-locking using the key complete all as specified & directed
SITC of Area Alarm for 3 Gas service: It should fully complies and meets with the requirements of the HTM 02-01 standards or NFPA-99 Standards recomendations and standards mentioned under these recomendations or applicable. . It shall be provided with a copy of the certificate of origin. Area Alarms are designed to include all necessary displays, factory wiring, transformers and circuitry requiring only 230 VAC primary powers. Internal voltage should be stepped down to S VDC and 1S VDC for control circuit Power. Voltage to external pressure or vacuum transducers should be 1S VDC. The Area Alarm should have digital display facility. Area alarm panels should be modular in design. Each gas monitored should have a light Emitting Diode (LED) display to continuously indicate actual line pressure. A vertical series of LED's should further indicate relative line pressure. The LED should show Normal pressure at SO psi. Apart from Normal it should also show low risk of 40 PSI as low-pressure and 60 psi as high. High risk of 30 psi as low pressure & 70 psi as High pressure. The back box should contain factory installed copper tube extensions 6" Long, 3/8" ID (1/2"0D) , to accept installer furnished lines form the medical gas system. Each inlet tube should accept gas - specific DISS fittings for transducers, to prevent cross-connection. The power supply should be installed in the back box Power supply should include an on I off rocker switch and a fuse holder. The audible alarm tone should pulsate, 90 dBa at 2 meters. The audible signal should be cancelled only by the alarm silence button or fault correction. The display should remain illuminated to indicate the presence of the alarm condition. The alarm should automatically reset with the correction of the fault condition. Should a new alarm occur while the panel is silenced, the audible alarm should reactivate. The area alarm should store the last four alarm conditions in memory at the alarm panel. These conditions can be indicated by using the buttons on the alarm panel control module complete all as specified and directed
SITC Oxygen flow meter with humidifier bottle unit as per HTM-2022/02-01 / NFPA-99 with CE marked with 4 digit notafied body No. The graduated scale should have an oval shape which allows a "lens effect" get the scale values easy-reading in any condition of use. The flowmeter should not have less then 50 mm adjusting knob with soft grip inserts for easy handling. The humidifier should be completely made of polycarbonate / polypropylene and should be autoclavable at 121 °C for 15 min. For the inlet connection it should have some snap inserts, identified with color-code, with different threads to be chosen by the end user. An ergonomic and big size rotating nut which allows easy connecting and disconnecting the humidifier to the oxygen supply device. The 360° rolling positioning hose connector ø 6÷9 mm allowing an easy use of the humidifier. The humidifier should have an integrated relief valve. The flowmeter should have an integrated pressure reducer for the stabilization of supplied pressure at 2.8bar, to guarantee the flow accuracy of the device. The flowmeter should be useable in any area of hospital with different pressure from the plants. complete all as specified & directed
Supply, Install, testing & commissioning complete set of Swivel motorized single Arm ceiling suspended beam system with at least 1.8 m extruded aluminum profile and two vertical pendents performing the support function, incl suspension tube, End cover set and beam profile with left & right vertical service columns, can rotate upto 330 to 340 degree with adjustable stopper complete all as specified & directed incl 01 set of the fwg accessories / parts. (a) Beam profile : 01 x indirect & 01 x direct. (b) Lighting 01 x indirect light & 01 x direct light. (c) Left side vertical column (d) Service head incl slider. (e) Lighting Control. (f) Light switch g, RJ45 socket (g) Provn of nurse call socket (cut out only) (h) 3 UPS power socket. (i) 3 IPS power socket. (j) Medical oxygen outlet with probe 01 Nos (k) Air 4 outlet with prob- 01 Nos (l) Vacuum Outlet with probe - 01 Nos (m) Accessories (i) IV pole 4 Hooks (ii) Right side vertical column (iii) Service head incl Slider
SITC of vertical bed head panel should comply with HTM 02-01/NFPA, 1500mm-1800mm length with 2 channels and 2 rows (vertical length) with single side rail: it should have 6 electrical sockets multipin 6/16 Amp sockets along with earthing sockets and wiring, 2 data sockets, provn for 6 Nos gas outlets points with Oxygen outlets - 02 Nos, Air 4 bar - 01 No, and Vacuum Outlets - 01 Nos incl outlet with matching probe points complete all as specified & directed
Supply, install & testing low pressure tubing as per CE certified / UL listed for oxygen, vacuum, Air complete all as specified & directed
S&F hospital sign bd of different types and size i.e. illuminated and others for depition of various wards, deptts, centres, services and other locations in the hospital incl day and night signs and patient guidence system complete all as specified & directed
M & L for cutting existing Oxygen/Air and Vacuum gas pipe line placing the controll valve as per the requirment and making leakage free gas pipe line complete all as specified & directed. Note- Valve of any description should be mesured separatly.
AUTOMATIC DRYER AND HAND SANITIZER S&F of compact size wall mounted Automatic hand dryer machine 1800 Watts having motor speed 2400 r/min, 220V, wind speed (>15m/s), touch free operation and blowing volume of 162 m3/h complete all as specified & directed
S&F wall mounted touch free liquid soap Automatic Hand Sanitizer Dispenser of capacity 600ml complete all as specified and directed
NURSE CALL SYSTEM S&F Wireless Multi Service Bed Unit for Three Service Call (For Patients’ Bed at wards) complete as required. Supply and fixing of wireless multiservice for three service call ( Nurse Calling, House Keeping and Code Blue) Bed unit and reset with Optional wireless door indicator, with built-in RFAF, environment condition, operating temp 0 degree centigrade-50 degree centigrade( 32 degree F - 122 degree F) operating voltage humidity 10%-90% without congealment power requirement, operating voltage 12 Voltage battery operating current -standby< 10 mA, working status < 10 mA packing contents wireless bed unit button with handset DC 12V battery screws and mounting plate including fixing accessories, complete all as specified and directed.
S&F Wireless Display System (For Nurse Station Area) complete as required. Supply and fixing of wireless display unit with human voice address and built-in RFAF frequency attention filter , having the following specification complete all as directed :- (i) Capacity : Max 50 beds, 7 seg LED display max, 2 digit for one bed receiving 3 LED indicators ( Nurse Calling, House Keeping and Code Blue), (ii) Power requirement : AC 230 V, 5Amps, 50 Hz (iii) Operating Temp : 0 to 50 degree ( 32 degree F - 122 degree F) (iv) Operating Humidity: 10%-90% without congealment (v) Operating Voltage : 05 volt DC-12 volt DC (vi) Operating current : 200mA, Standy<30mA, Full load<35mA (vii) Startup current : 600 mA (viii) Speaker : Full duplex (ix) Impedance : 8C + 15% (x) Max output Power : 0.5 W (xi) Distribution Rate : 5% Max (xii) Max dB : 89 + 3dB (xiii) Frequency Range : 433 KHz
SS&F 2 Mtr Wired handset for Three Service Calling, Reset Facility and Optional Door Indicator complete all as specified & directed
HOT WATER SUPPLY S&F Hot water storage(Geyser)25 Ltrs capacity,BEE 5 star rated,vertical type with suitable size of fastener and including provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure, having heating element 2 KW and minimum two year warranty on product, minimum 3 years warranty on heating element complete all as specified and directed
SUMMER APPLIANCES S&F refrigerator of capacity 165 Ltr single door/double door ,single phase electric driven 230 Volt ,50 Hz five star rated including stand for refrigerator all as directed and specified
Supply and installation and commissioning of water cooler stainless steel body eletric driven (Single Phase) having storage caoacity of 80 Ltr and nominal cooling capacity 40 Ltr per hours (40/80) complete all as specified & directed
AIR CONDITIONING S&F air cooled split unit air conditioner inverter type hot and cold, indoor and outdoor unit with provision of extra copper pipe and sleeve insulation as required, electric driven, Copper Coils, cordless remote, non-CFC refrigerant with initial charge of refrigerant, drain pipe for condensed water to nearest drain, single phase of capacity of 1.5 TR, BEE 4 star rated split AC,complete all as specified and directed Note: 1. T&P, crane/hydra required to install AC is deemed to be included in quoted rates. 2. Outdoor unit shall be fixed either on slab or wall, necessary frame for mounting outdoor unit on wall/slab is deemed to be included in quoted rates. 3. In case of unavailability of above mentioned star rate one lower star rating shall bt procured at no extra cost
Supply, Installation Electronic Voltage Stabilizer metallic body and connecting with split AC having multi-protection Advance Technology with Transformer Single Phase Naturally Air Cooled Indoor type Wall mounted and designed for Input variation 130 Volt to 300 Volt with Output Voltage stabilized at 230 Volt with accuracy of (+) 2.5% and of capacity 5.0 KVA, complete all as specified and as directed
Description of Work / Item(s)
Amount
Total amount of REVISED Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of REVISED Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of REVISED Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road, Path & Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of REVISED Sch 'A' Section VIII (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of REVISED Sch 'A' Section IX (Fire Fighting & FIRE ALARM SYSTEM E/M WORKS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of REVISED Sch 'A' Section X (UPS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (Lift) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (LIGHTENING PROTECTION) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Demolition & Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
Global Enterprises
G and G Infratech Private Limited
AMIT ASSOCIATES
R K GOEL ABHEY KUMAR JAIN
SOOD ASSOCIATES PVT LTD
Ktech Engineer Builders Co. Pvt. Ltd
Global Enterprises
AMIT ASSOCIATES
SOOD ASSOCIATES PVT LTD
G and G Infratech Private Limited
R K GOEL ABHEY KUMAR JAIN
Ktech Engineer Builders Co. Pvt. Ltd
Bidder Name
AMIT ASSOCIATES
Ktech Engineer Builders Co. Pvt. Ltd
Global Enterprises
SOOD ASSOCIATES PVT LTD
R K GOEL ABHEY KUMAR JAIN
Siya constructions
G and G Infratech Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .