Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-AOC | ₹7.9 Cr Quoted ₹10.0 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹10.9 Cr+₹89.1 L (8.94%)Rejected-Finance | ₹10.9 Cr+₹89.1 L (8.94%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹10.9 Cr+₹90.0 L (9.02%)Rejected-Finance H NO 282 GREEN CITY II BATHINDA | BATHINDA | PUNJAB | 151001 | ₹10.9 Cr+₹90.0 L (9.02%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹11.0 Cr+₹1.0 Cr (10.3%)Rejected-Finance SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹11.0 Cr+₹1.0 Cr (10.3%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹11.1 Cr+₹1.1 Cr (11.0%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹11.1 Cr+₹1.1 Cr (11.0%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹8.9 Cr
EMD Value
₹7.7 L
Closing Date
2 Dec 2021, 6:00 pmClosed
Chief Engineer
HQ CE Bathinda Zone
AUGMENTATION AND IMPROVEMENT OF WATER SUPPLY SYSTEM INCLUDING SCADA FOR PUMPING AND WATER TESTING AT BATHINDA MIL STN
2021_MES_471659_1
CE BTZ/BTD/TOKEN-17 OF 2021-22
Open Tender
Civil Works
Lump-sum
365 days
Bathinda Mil Stn
As per NIT
10 documents required · 10 mandatory
₹3,000
GE (U) Bathinda
₹7.7 L
Yes
16 Dec 2021
1 Sept 2021
4 Dec 2021
2 Sept 2021
2 Dec 2021
16 Nov 2021
Amount
Lump sum price worked out by the tenderer for "Building Work" as listed in Schedule ‘A’ Section - I.
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Section-II (Part-I)
Sch 'A' Sec - II (Part-II) (INTERNAL ELECTRIFICATION WORK)
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches/socket, wiring for one light point/fan point /bell point controlled by one switch, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of Sch A/BOQ).
All as per Srl No.4.00 here-in-before but for socket outlet 5 Amps on the same board. (switch/socket shall be measured and paid separately under appropriate item of Sch A/BOQ).
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switch and socket combination, wiring for one socket out let 15 Amps point controlled by one switch (on independant board), including provn of 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (combination switch/socket shall be measured and paid separately under appropriate item of Sch A/BOQ).
Supply and hanging/fixing ceiling fan BEE approved, minimum 2 star rating 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 240 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed), including capacitor 2.5mfd, canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with and including PVC insulated PVC sheathed copper conductor flexible cable 1.5 sqmm, 3 core from connector to fan complete all as specified and as directed. Note :- (i) Srl Number of ceiling fan and GE office name shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number shall be issued by Engineer-in-Charge.
Supply and fixing exhaust fan BEE approved, energy saver/energy-efficient, 450 mm sweep matal body with louvres, 240V, 50Hz, single phase, mounted on wall in suitable opening arrangement with 4 Nos steel fastners 12mm dia 100mm long and making good the disturbed surface including making electrical connection with and including PVC insulated PVC sheathed copper conductor flexible cable 1.5 sqmm, 3 core from connector to fan complete all as specified and as directed. Note :- (i) Srl Number of exhaust fan and GE office name shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number shall be issued by Engineer-in-Charge.
Supply and fixing LED complete fitting including batten and T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and as directed.:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED street light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications, and all as directed. (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Minimum 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Material and labour for Brackets made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x5 mm for fixing of bracket on wall / poles with suitable nuts and bolts including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing (concealed in wall) factory made DB (made out of CRCA sheet duly powder coated) SPN, 6 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting/provision of RCBO / MCB / Isolator etc, as incomer and outgoing, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and as directed. Note :- RCBO / MCB / Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers, protected by 15 mm bore GI medium grade pipe upto and including test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto test point from top of earth plate i.e. minimum 7.5 metre shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II) (EXTERNAL WATER SUPPLY WORKS)
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 500mm confirming to IS : 8329, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 300mm confirming to IS : 8329, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 200mm confirming to IS : 8329, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 150mm confirming to IS : 8329, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 bore 100mm confirming to IS : 8329, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9 confirming to IS : 8329 of bore 80 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7 confirming to IS : 8329 of bore 250 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7 confirming to IS : 8329 of bore 200 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7 confirming to IS : 8329 of bore 150 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7 confirming to IS : 8329 of bore 100 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7 confirming to IS : 8329 of bore 80 mm, spigot & socketed ends centrifugally cast suitable for rubber tyton joints complete all as specified and as directed. Note : (a) Earth work and DI specials/ fittings shall be measured and paid separetly. (b) Cost of joints (push on tyton joints) including jointing materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supplying & fixing Ductile iron specials/ fittings of any size, any type like Bends, tapers, increasing, decreasing sockets, tees (Single and double branch), tail pieces and collars etc complete all as specified and as directed. Note:- Make of DI fittings shall be same make as that of DI pipe or of make recommended by manufacturer of pipe.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 500 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 300 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 200 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 150 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 100 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.6 (long body ) ISI marked confirming to IS:14846-2000 suitable for 80 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.0 (long body ) ISI marked confirming to IS:14846-2000 suitable for 250 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.0 (long body ) ISI marked confirming to IS:14846-2000 suitable for 200 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.0 (long body ) ISI marked confirming to IS:14846-2000 suitable for 150 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.0 (long body ) ISI marked confirming to IS:14846-2000 suitable for 100 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1.0 (long body ) ISI marked confirming to IS:14846-2000 suitable for 80 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron Air Valves with two air outlets (ISI marked), confirming to IS:14845-2000 suitable for 150 mm bore pipe, flanged ends, drilled, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron Air Valves with two air outlets (ISI marked), confirming to IS:14845-2000 suitable for 100 mm bore pipe, flanged ends, drilled, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Material and labour for cutting of road/dismantling of interlocking paver blocks from pathways including excavation and earth work upto required depth complete all as specified and as directed. Note :PCC and interlocking tiles for making good disturbed surface will be measured and paid separetely.
Supply and laying 80 mm thick (M40 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over and including 25mm thick layer of sand and filling the interstices etc with sand complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Supply, installation, commissioning and testing of pumping set centrifugal horizontal split casing type mounted on common base plate foundation having discharge 5296 LPM and 60 mtr head directly coupled with and including electric motor minimum capacity of 100 HP, 3 phase, 415 volts, 50 Hz, 1440 RPM complete including PCC foundation, copper conductor cable of suitable size including protection flexible pipe for cable from starter to motor terminal, Suction line pipe CI & fitting flanged, Foot Valve, Pressure Guage and Air Vent pipe, Fitting Accessories required complete all as per manufacturer's recommendation/Design. Complete all as directed with all accessories and comprising of the following:-
Delivery line of pump set using flanged type DI pipe class k9 of suitable size from pump to delivery header including DI flanged fittings and joint with nuts, bolts, washers etc complete.
Cast iron non return valve PN 1.6, ISI marked confirming to IS:5312-2004 suitable size, flanged ends, drilled, complete including jointing material such as nuts, bolts, washers and rubber sheet etc
06 runs of Single core cable PVC insulated copper conductor, multistranded, 1100 volts grade of suitable size drawn through and including PVC flexible pipe from motor to starter panel for each pump set complete connection with copper lugs, cable glands etc.
PCC foundation in CM 1:2:4 type B-2 using 40 mm graded aggregate 20 cm above GL and 30 cm below GL including grouting of eye bolts nuts etc for pump set/motor of adequate size as per manufactureres reccommendations.
Common base frame suitable for above pump set as per manufacturers recommendation.
Note :- (i) Cost of alignment with dial guage and making necessary adjustments including shim packing etc and NRV with each pump including jointing material shall deemed included in unit rate quoted by contractor. (ii) Sluice valve of suitable size shall be measured and paid seperately under respective item of Sch.
Supply, installation, commissioning and testing of monoblock pumping set Discharge 1.9 LPS to 0.4 LPS with 14 to 28 mtr head with and including electric motor capacity of 1 HP, 230 volt, 50 Hz including making water connection and electric connection complete all as directed.
Material and labour for installing and construction of 'Fire Point' at approved location, including MS work as shed and stand, platform and associated civil works, painted white inside and red outside and black on the bottom inscribed with letters "FIRE" in black and gold, painting etc complete all as specified and shown on drawings and comprising with the following items:- (a) Fire Buckets 13.5 ltrs made out of 24 gauge galvanised steel - 04 Nos (b) Sand buckets 13.5ltrs-04Nos (c) Fire Hooks-01 No (d) Fire beater-01 No (e) Fire Alarm Bell-01 No (f) Felling Axe - 01 No (g) Axe-01 No (h) Shovel - 01 No (j) Fire extinguisher CO2 type - 01 No. (k) Fire extinguisher Mechanical foam - 01 No. (l) Pick Axe - 01 No.
Supply and fixing online multiple parameter sensor with common contoller complete all as directed and comprising with the following :-
Chlorine analyser
Turbidity
PH Electrode
TDS ( Conductivity Electrode)
Sc 1000 common controller for above all parameter
Make :- HACH/Thermo Fisher/Shimadzu
Notes :- (i) All fixing arrangements shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Installation shall be carried out by authorised rep of manufacturer. (iii) Modification if any required in existing system shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supply and fixing Multiple parameter Lab spectro photometer complete all as directed and comprising with the following :-
Hach lab spectrophotometer
Fluoride reagent solution ,500 MI total number of test 125 numbers range 0.02 to 2 Mg/l
Iron method Name: Ferrozine number of tests:50, Parameter : Iron Qty :50/p Range :0.009-1.400 mg/l Fe
Sulphate Method : 8051 method: Sulfa Ver 4, Number of tests:100, Parameter : Sulfate, Platform:Powder Pillows Qty : 100/pk, Range : 2-70 Mg/l SO 42
Nitra Vere 5 Nitrate Reagent, Powder Pillows-10 ml pk/100 Nitrate 100 test range 0.3-30 Mg/L NO3-Nt
Make :- HACH/Thermo Fisher/Shimadzu
Notes :- (i) All fixing arrangements shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Installation shall be carried out by authorised rep of manufacturer. (iii) Modification if any required in existing system shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supply and fixing full bore Electromagnetic flow meter of size 500 mm (Product code:FM-15) complete all as directed and comprising with the following :- Operating Temp=0 to 85°C, Max Speed=10m/sec, Sensor part=IP-67, Metering tubes S.s 316, Electrode SS 316L, Hard Rubber lining, Turn down ratio 1:10 Flanged ends #150, PU painted, Transmitter : Power Supply 230 VAC 4-20 Ma Output, pulse output RS 485 communication port, 8 digits display with resettable totalizer, LED backlight with LCD display, SS tag plate, IP-65 Enclosure Accuracy=0.5%, Internal type display (Qty 02 Nos for Pumping main PPH to SPH and 02 Nos for Pumping main to Shivaji Pump house)
Make :- Federal/Genco/Jyoti/Paras/Blento/Kranti/Sant
Notes :- (i) All fixing/jointing arrangements and materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Installation shall be carried out by authorised rep of manufacturer. (iii) Modification if any required in existing system shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supply and fixing full bore Electromagnetic flow meter of size 600 mm (Product code:FM-15) complete all as directed and comprising with the following :- Operating Temp=0 to 85°C, Max Speed=10m/sec, Sensor part=IP-67, Metering tubes S.s 316, Electrode SS 316L, Hard Rubber lining, Turn down ratio 1:10 Flanged ends #150, PU painted, Transmitter : Power Supply 230 VAC 4-20 Ma Output, pulse output RS 485 communication port, 8 digits display with resettable totalizer, LED backlight with LCD display, SS tag plate, IP-65 Enclosure Accuracy=0.5%, Internal type display (Qty 01 No for Old Raw water Jackwell, 01 No for New Raw water Jackwell and 01 No for Raw water for FP No:04 )
Make :- Federal/Genco/Jyoti/Paras/Blento/Kranti/Sant
Notes :- (i) All fixing/jointing arrangements and materials shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Installation shall be carried out by authorised rep of manufacturer. (iii) Modification if any required in existing system shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame made from angle 50x50x6mm, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at new pump room at secondary pump house :-
Busbar chamber with copper bus bar of capacity 400 Amps mounted on procelain insulations and shall be provided with inspection covers - 04 Nos
MCCB 4 Pole 250 amps, 415 Volt of breaking capacity not less than 36 KA with adjustable thermal and magnetic release - 01 No
MCCB 4 Pole, 125 amps, 415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable thermal release 0.64 to 1.0 & adjustable magnetic release 3.5 to 10.0 In - 02 Nos
Automatic star delta starter suitable for 100 HP motor - 02 Nos
Chage over switch 04 pole 415 volts of capacity 250 Amps - 02 Nos
Single phase preventor - 02 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
MCB 10 Amp, - 01 No
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame of suitable size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at old Secondary Pump house :-
Busbar chamber with Copper bus bar of capacity 1200 Amps mounted on porcelain insulators and shall be provided with inspection covers - 04 Nos
Fixed type ACB 4 Pole 800 amps , 415 Volt of breaking capacity not less than 50KA electrical release - 01 No
MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 02 Nos
Automatic star delta starter suitable for 125 HP motor - 02 Nos
Starter suitable for 5 HP Submersible pump including MCB TPN 32 Amps -01 No
Single phase preventor - 03 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame of suitable size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at old Secondary Pump house :-
Busbar chamber with Copper bus bar of capacity 1200 Amps mounted on porcelain insulators and shall be provided with inspection covers- 04 Nos
Fixed type ACB 4 Pole 800 amps,415 Volt of breaking capacity not less than 50KA electrical release - 01 No
MCCB 4 Pole, 630 amps , 415 Volt of breaking capacity not less than 50 KA, Ics=100 % of Icu, adjustable thermal release 0.64 to 1.0 & adjustable magnetic release 3.5 to 10.0 In - 01No
MCCB 4 Pole, 400 amps, 415 Volt of breaking capacity not less than 50 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 No
MCCB 4 Pole, 250 amps, 415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 02 Nos
Automatic star delta starter suitable for 125 HP motor - 02 Nos
Single phase preventor - 02 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame of suitable size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at New Secondary Pump house :-
Busbar chamber with Copper bus bar of capacity 1200 Amps mounted on porcelain insulators and shall be provided with inspection covers - 04 Nos
Chage over switch 04 pole 415 volts of 800 Amps capacity - 02 Nos
MCCB 4 Pole 250 amps , 415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 04 Nos
Automatic star delta starter suitable for 125 HP motor - 04 Nos
Single phase preventor - 04 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame of suitable size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at MAP pump house at PPH :-
Busbar chamber with Copper bus bar of capacity 1200 Amps mounted on porcelain insulators and shall be provided with inspection covers - 04 Nos
Chage over switch 04 pole 415 volts of 800 Amps capacity - 02 Nos
Fixed type ACB 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50KA electrical release - 01 No
MCCB 4 Pole, 250amps, 415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) adjustable thermal release 0.64 to 1.0 & adjustable magnetic release 3.5 to 10.0 In - 02 Nos
MCCB 4 Pole 200 amps, 415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 03 Nos
MCCB 4 Pole 100 amps, 415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 04 Nos
Automatic star delta starter suitable for 75 HP motor - 02 Nos
Automatic star delta starter suitable for 40 HP motor - 03 Nos
Automatic star delta starter suitable for 15 HP motor - 04 Nos
Single phase preventor - 09 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Supply, installing, commissioning and testing of factory made LT panel board (indoor type for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size dust, weather and vermin proof made out of CRCA powder coated paint with seven tank process for treatment of degreasing, pickling and two coats primer before being given the stove epoxy finish sheet 2 mm thick machine pressed and angle iron pedestal frame of suitable size, including provision of thimble and cable entry boxes with cable glands. pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated, Panel should covered from all sides with front and back door openable with hinges including locking arrangements complete with separate bus bar chamber, including painting to MS angle frame with two coats synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed and comprising with the following installed at New Raw water pump house :-
Busbar chamber with Copper bus bar of capacity 600 Amps mounted on porcelain insulators and shall be provided with inspection covers - 04 Nos
Chage over switch 04 pole 415 volts of 800 Amps capacity - 02 Nos
MCCB 4 Pole 400 amps, 415 Volt of breaking capacity not less than 50 KA (Ics=100 % of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 No
MCCB 4 Pole, 250 amps, 415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) adjustable thermal release 0.70 to 1.0 & adjustable magnetic release 3.5 to 10.0 In - 03 Nos
Automatic star delta starter suitable for 75 HP motor - 03 Nos
Single phase preventor - 03 Nos
Indicating lamps LED type (RYB, set of three) - 01 set
CT for Ammeter 0-15VA
Interconnection of MCCBs and motor starters with suitable size and rating copper strips
Control wiring with suitable size of copper/aluminium conductor cable.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Disconnecting the exishing cables of any size and type and reconnecting back to newly installed LT starter panels at appropriate terminals with suitable sizes of lugs, glands etc. without any extra cost to department.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTIC WORKS" as listed in Schedule ‘A’ Section - IV (Part-I)
Sch 'A' Sec - IV (Part-II), (EXTERNAL ELECTIC WORKS)
Sand cushioning, with dry and clean local tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. (Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Material and labour for Cable path indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8 mm thick with provision of 600 mm long (minimum) single leg/stand of angle iron 25 x 25 x 3 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of size 300mm x 300 mm x 200 mm complete all as specified and as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip of size 32 x 6 mm flat by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe upto and including test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) and all as directed. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto test point from top of earth plate and further upto the body of electric equipment shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Subtotal
Sch 'A' Sec - V, (DG SET WORKS)
Supply, installation, commissioning and testing diesel engine driven, water cooled, silent Generating Set 128KW/160 KVA capacity, 1500RPM, suitable capacity of BHP to give output 160 KVA, with electronic governor, 3 phase, 415 volts, 50 Hz, power factor 0.8 applicable for supplying power to varying electrical load for unlimited hours with 10% over load capacity, complete with self starting system with AMF panel (automatic starting of main failure control panel), including common base plate, floor mounted with anti vibration pads, factory asembled complete fitted in acoustic enclosure (sound proof canopy of authorised OEM of manufacturer's of DG set given in appendix 'B' ) approved by National Physical laboratory as per CPCB latest norms/regulation, including PCC foundatin/platform for generating set as per manufacture's instruction, complete including accessories, equipment control panel etc and confirming to condition under IS-4722 BS 5514/2613/5000/10001/10002/13664 complete all as specified and as directed and comprising with the following :-
Alternator:- 128 KW output at 0.8 PF AC 3 phase 4 wire 415 volts 50 C/S, brush less, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces, class 'H' insulation with IP-23 protection and voltage regulation +/- 1.5% as per IS-4722 or BS 2613 -1970
Diesel engine : Diesel engine multi cylinder 4 stroke, water cooled electric start suitable capacity to drive above alternator independently, coupled directly through flexible coupling, cold starting, speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump preheaters etc
Control panel :- The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for the followings- (i) Gen set controller microprocessor based multifunctional with LED display for engine water temperature, Lub oil pressure, Engine RPM, Engine shut down display, total Hours run and suitable for protection against high water pressure, low lub oil pressure, over speed and battery charger failure. (ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as Voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port complete with appropriate CTs and control wiring. (iii) MCCB 4 pole 415 volt AC of suitable capacity not less than 250 Amps all as required complete with copper bus bar all as per standard engineering practice and as per manufacturer recomendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc.
Electric Starter Equipment :- The equipment will comprise the followings:- (i) Start Stop push button. (ii) Maint free Battery duly initial charged & Battery lead of adequate capacity (iii) Starter motor (iv) Starter gearing (v) Alternator/ dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut
Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is off position.
Note :- (a) Cost of maintainance free batteries as per recoomondations of manufacture shall deemed included in unit rate quoted by contractor (b) Cost of PCC foundation as per reccomondations of manufacturar shall deemed included in unit rate quoted by contractor. (d) Pre commissions test shall be carried out by rep of accepting officer. All necessary equipments, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor.
Subtotal
Lump sum price worked out by the tenderer for “Excavation and Earth work" as listed in Schedule ‘A’ Section - VI
Sch 'A' Sec - VII (DISMANTLING/DEMOLITION WORKS)
Dismantling and taking up/down old unserviceable CI pipe 500mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 300mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 250mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 200mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 150mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 100mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI pipe 80mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable PVC pipe 75mm bore any class complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 500 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 300 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 250 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 200 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 150 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 100 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI Sluice valve 80 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI ARV 150 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI ARV 100 mm dia complete all as directed.
Dismantling and taking up/down old unserviceable CI/DI Special of any size complete all as directed.
Dismantling and taking down old unserviceable LT Panel any type and size complete all as directed.
Note for item No 72 to 89 :- Excavation and returning filling shall be measured and paid separately under appropriate item of Sch A section-VI. Extra earth to the extent required for leveling the ground shall be brought from item No 4 of Sch 'A' section-VI . Cost for extra lead if any shall be deemed to be included in the same.
Subtotal
M/S N.K BUILDERS
M/s Azure Infrastructure Construction Co.
ENGINEER CONSTRUCTION PVT. LTD.
M K ENGINEERS CO.
FRIZO INDIA PVT LTD
ASHISH JINDAL BUILDERS PVT. LTD.
Jagdish Prashad and Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .