Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹6.2 L+₹3,209.60 (0.52%)Accepted-Finance | L2 | Accepted-Finance ok | |
| 3 | L3₹6.2 L+₹4,189 (0.68%)Accepted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | L3 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹16,500
Closing Date
5 Mar 2024, 2:30 pmClosed
EE (EnM) HP-II
OFFICE OF THE EXECUTIVE ENGINEER (EnM) HP-II DELHI JAL BOARD GOVT OF NCT OF DELHI HAIDER PUR WATER WORKS, DELHI 110085
Improvement of Internal and External Lightening arrangements and Electrification work in Filter House (North ) HPWW-II.
2024_DJB_254877_4
NIT 9 (2023-24) HP-II
Open Tender
Miscellaneous Works
Item Rate
60 days
DJB, WTP Haiderpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DELHI JAL BOARD
₹16,500
Yes
16 Mar 2024
28 Feb 2024
5 Mar 2024
28 Feb 2024
5 Mar 2024
28 Feb 2024
Wiring for lightpoint/ fanpoint/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C ( As per DJB SOR (E&M) 2022, 31.10.3)
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.DSR(2021-22)/ 31.14 2X1.5sq.mm+1 X1.5sq.mm earthwire ( As per DJB SOR (E&M) 2022, 31.14.1)
2X2.5sq.mm+1 X2.5sq.mm earthwire ( As per DJB SOR (E&M) 2022, 31.14.2)
2 X 4 sq. mm + 1 X 4 sq. mm earthwire ( As per DJB SOR (E&M) 2022, 31.14.3)
2 X 6 sq. mm + 1 X 6 sq. mm earthwire ( As per DJB SOR (E&M) 2022, 31.14.4)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (As per DJB SOR (E&M) 2022, 31.24) 5/6 A switch ( As per DJB SOR (E&M) 2022,31.24.1)
15/16 A switch ( As per DJB SOR (E&M) 2022,31.24.3)
3 pin 5/6 A socket outlet ( As per DJB SOR (E&M) 2022,31.24.4)
6 pin 15/16 A socket outlet ( As per DJB SOR (E&M) 2022,31.24.5)
Supplying and fixing of 8way(4+24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. Asrequired.(But without)MCB/RCCB/Isolator).DSR(2021-22)/ 32.4.3)
Providing and fixing of 63A TP&N capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.DSR(2021-22)/ 32.1.2
Providing and fixing of 100 A, 16KA, TPMCCB rating and breaking capacity and pole MCCB with thermo magnetic release and terminal providing and fixing following rating and breaking capacity and spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required DSR(2021-22)/ 32.2.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.DSR(2021-22)/ 32.10.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required DSR(2021-22)/ 32.10.3
Supply of Ceiling fans (1200mm sweep) 230volt 50hz upto 80watt power ratting as required at site. Make: Bajaj, Havells, Crompton any other make approved by DJB SOR 20.1.2
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up-to 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.DSR(2021-22)/31.45
Supply and fixing extra conduit own rod of 20cm length GI pipe 15 mm dia. heavy gauge including painting etc. as required. (Note: More than 5cm lengths hall be rounded to the nearest 10 cm and 5 cm Or less shall be ignored)DSR(2021-22)/ 31.48
Supply of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. (AS per DJB SOR (E&M) 2022, 19.10.6)
Installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC Insulated, copper conductor, single core cable and earthing etc. as required.DSR(2021-22)/31.41
Supply of 50 sq.mm 4 core aluminium conductor armoured cable as required at site
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and up-to 95 sq. mm (clamped with 25x3mm MS flat clamp) of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required( As per DJB SOR DSR(2022)/ 37.1.2)
ASHMITA ENGINEERS AND TRADERS
Devraj Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .