| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | ₹18.2 L Quoted ₹18.5 L | L1 | Accepted-AOC Being Lowest L1 |
| 2 | L2₹20.0 L+₹1.4 L (7.73%)Rejected-Finance | ₹20.0 L+₹1.4 L (7.73%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹22.6 L+₹4.1 L (22.1%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹22.6 L+₹4.1 L (22.1%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹24.0 L+₹5.5 L (29.6%)Rejected-Finance VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | ₹24.0 L+₹5.5 L (29.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹28.5 L+₹9.9 L (53.7%)Rejected-Finance | ₹28.5 L+₹9.9 L (53.7%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
4 Sept 2021, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
CLEANING AND MAINTENANCE OF SEWAGE LINE, MAN HOLE, SEPTIC TANK, WATER TANKS, REPAIR TO FENCING, DRAINS AND ROADS AT AIR FORCE STATION DALHOUSIE
2021_MES_466005_1
8420/GE/PAF-30/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE (AF) PATHANKOT
as per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹60,000
Yes
13 Oct 2021
7 Aug 2021
6 Sept 2021
7 Aug 2021
4 Sept 2021
21 Aug 2021
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for sewage pipe line not exceeding 10 Sqm on plan for man holes and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m in depth getting out in hard/dense soil complete, all as specified and directed by Engineer-in-Charge.
Excavation in post holes not exceeding 0.5 cum each getting out , returning filling in and ramming earth around in layers not exceeding 25 cm each all as specified in hard/dense soil including removalof surplus soil upto 50 mtrs distance complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete, all as specified and directed by Engineer-in-Charge.
Removal of excavated and demolished material to a distance exc. 1.50 km but n exc. 5 km and depositing complete all as specified and directed by Engineer-in-Charge.
PCC 1:3:6 Type C2 40mm graded stone aggregate as in Surface channels and drains complete all as specified and as directed by the Engineer-in-Charge.
Demolition of RCC cover slab reinforcement cut to facilitate demolition, complete all as specified and directed by Engineer-in-Charge.
Pre-cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate in cover slab and the likes and set in cement mortar 1:4 complete including necessary form work and demolition of existing cover slabs reinforcement cut as required to faciliate complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or Stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and as directed by the Engineer-in-Charge.
Brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
All as per item No. 10 above, but except brick, complete all as specified and directed by Engineer-in-Charge.
Brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 12 above but except bricks complete all as specified and directed by Engineer-in-Charge.
TMT bars 8 mm dia cut to length, bent to shape, required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick in cement mortar 1:4 on brick surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
S & F as in repair triple layer 500ltr capacity rotational moulded polythyelene water storage tanks (cylindrical vertical with threaded closed top) hoisted and fixed in position with all its fittings and fixing complete brass float valve and its items including dismantling existing tank complete all as specified and directed by Engineer-in-Charge.
S & F as in repair triple layer 1000ltr capacity rotational moulded polythyelene water storage tanks (cylindrical vertical with threaded closed top) hoisted and fixed in position with all its fittings and fixing complete brass float valve and its items including dismantling existing tank complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes(any type), jointed in cement mortar and taking out trenches, complete all as specified and as directed by the Engineer-in-Charge.
100mm dia cast iron sand cast pipe waste or vent pipe in any length with or without ears with cement joints laid in trenches complete all as specified and directed by Engineer-in-Charge.
100 mm dia cast iron sand cast pipe waste or vent pipe in any length with or without ears with lead joint fixed to wall complete all as specified and directed by Engineer-in-Charge.
All as per Srl Item No 20 above but 75 mm, complete all as specified and directed by Engineer-in-Charge.
100 mm bore of pipe cast iron bends (any radius) diminishing pieces or traper (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
All as per Srl Item No 22 above but 75 mm complete all as specified and directed by Engineer-in-Charge.
100 mm branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed by Engineer-in-Charge.
All as per Srl Item No 24 above but 75 mm, complete all as specified and directed by Engineer-in-Charge.
Cast ion 100mm dia floor trap, with grating including jointing to waste pipe fixed in cement concrete Type B-1 (1:2:4),including dismentlinng/ removing old floor trap all as specified and as directed by the Engineer-in-Charge
All as per Srl Item No 26 above but 75 mm, complete all as specified and directed by Engineer-in-Charge.
Cast ion 100mm dia nahani trap, with grating including jointing to waste pipe fixed in cement concrete Type B-1 (1:2:4),including dismentlinng/ removing old floor trap all as specified and as directed by the Engineer-in-Charge
All as per Srl Item No 28 above but 75 mm, complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (salt glazed ware or AC or reinforced concrete) 150 mm set in cement mortar complete all as specified and directed by Engineer-in-Charge. (Excavation work will be measured and paid seprately).
Salt glazed stone ware drain pipes 150 mm dia laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
Cement concrete (1:3:6) type C-2 to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia bore of pipe complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drain, making good to pipe, rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for pipe for internal dia 150 mm complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for removing existing branch drain making good in walling and rendering cutting out branch and making goodbenching for pipe for internal dia 150 mm complete all as specified and directed by Engineer-in-Charge.
Cleaning of sewer lines of various sizes by rodding from manhole to manholes 150mm dia complete all as specified and as directed by the Engineer-in-Charge.
Cleaning of sewer lines of various sizes by rodding from manhole to manholes 100mm dia complete all as specified and as directed by the Engineer-in-Charge
Cleaning of manholes n exc 1m deep complete all as specified and as directed by the Engineer-in-Charge
Cleaning of manholes exc 1m deep complete all as specified and as directed by the Engineer-in-Charge
Desluging and cleaning of septic tank/manholes of various capacity and sizes and burying the sludge in a pit waste materials in borrow pits os suitable sixe & covering the same by spreading earth & spresading bleaching powder on it (The rates includes for making borrow pits with in 100mtr & removing, surplus soil upto 50mtr distance) complete all as specified and as directed by the Engineer-in-Charge. Note:- (i) Road side septic tank should be cleaned by mechanical method. (ii) De-slugged material of septic tank and manholes should be disposed outside the campus area.
Hand packing broken stone (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed by Engineer-in-Charge.
PCC Type D-2 (1:4:8) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
PCC bond stone Type C-2 (1:2:4) for stone walling in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Walling of random rubble, uncoursed, well bonded, bedded in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 43, above but except stone complete all as specified and as directed by the Engineer-in-Charge.
Demolition of concrete of any description and in any position not otherwse specifically provided
PCC 1:3:6 Type C1 20 mm graded aggregate as in wall or retaining wall, any thickness, size or shape including pilasters buttresses columns, pillars boundary pillars andposts (including caps and bases) complete all as spefcified and as directed by the Engineer-in-Charge.
Preparation of new steel surfaces applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10 cm in width or grith, not otherwise described complete all as specified and directed by Engineer-in-Charge.
Preparation of new surfaces and two coats of exterior acrylic paint of any shade over a coat of primer as approved by GE over new plastered surfaces of walls as per manufacturer’s instructions complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron of mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
Mild steel work conforming to Fe 290 GdeE-165 as in angle iron posts with swan neck (horn) and struts fencing including cutting tops to shape also directed drilling holes notching for wire etc necessary drilling bolting as welding / riveting etc complete all as specified and directed by Engineer-in-Charge.
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-Charge. (each line wire to be measured
Restraining and resecuring including making good staples etc. as in galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-Charge. (each line wire to be measured).
Dismantling fencing wire mesh, any type, complete all as specified and directed by Engineer-in-Charge.
S & F 4 mm dai galvanised steel wire 150x100 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after fitting complete all as specified.
Machine pressed coloured precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 grade after spreading and levelling in layers n exc. 25 cm thick sand cushioning properly levelled to existing gradient complete all as specified and as directed by Engineer-in-Charge.
Dismatling of floor tiling including cement mortar bedded but not backing complete all as specified and directed by Engineer-in-Charge.
Chequered cement concrete tiles 22 to 25mm thick, set jointed and pointed in neat cement slurry in floors, with grey cement and no pigment and including Screed bed or bedding layer of mortar 15mm thick in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge
Demolotion of concrete in ground floor not exceeding 15cm in thickness below or above ground level including floor finish such as tiles of any thickness and any description etc complete all as specified and directed by Engineer-in-Charge.
PCC 1:2:4 type B-2, 100 mm thick (using 40mm graded aggregate), spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified as in floors complete all as specified and directed by Engineer-in-Charge
Roshan Lal Thakur
Vijay Kumar Contractor and Engineers
Havish Construction
M/S Ajay Kumar Mahajan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .