Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC VILL SHYAMTHAIBARI PO KHUNGRING PS RUNIKHATA DIST CHIRANG PIN 783375 | CHIRANG | ASSAM | 783375 | L1 | Accepted-AOC accept | |
| 2 | L2₹28.8 L+₹395 (0.01%)Rejected-AOC | L2 | Rejected-AOC reject | |
| 3 | L3₹28.9 L+₹1,057 (0.04%)Rejected-AOC C O LT MAAHANTA NARZARY W NO 5 TENGAPARA P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | L3 | Rejected-AOC reject |
Tender Value
₹28.8 L
EMD Value
₹28,845
Closing Date
22 Feb 2022, 2:00 pmClosed
SE Kokrajhar Bldg Circle Kokrajhar
SE Kokrajhar Bldg Circle Kokrajhar
Construction of Auditorium hall at Khungring High School in Chirang District TN-601/1
2022_BoTC_24316_1
TN-601-1
Open Tender
Civil Works - Building
Works
180 days
Chirang
Please refer Tender documents.
5 documents required · 5 mandatory
₹865
the Principal Secretary BTC Kokrajhar
₹28,845
Yes
28 Mar 2022
11 Feb 2022
23 Feb 2022
11 Feb 2022
22 Feb 2022
11 Feb 2022
11 Feb 2022 - 22 Feb 2022
Amount
(A) Const. of Auditorium Hall: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceedig 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth leadupto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level l:3:6 (l Cement : 3 coarse sand (zone-lll): 6 graded stone.
Steel reinforcement for RCC work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C. 1 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.5.9 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, pillars, piers, abutments, posts and struts
5.19 Weather shade, Chajjas, corbels etc. including edges
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay modular bricks designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15* landings, balconies, shelves, chahjjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor level, excluding the cost of centering, shuttering, finished and reinforcement with 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm ominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor level, excluding cost of centering, shuttering, finishing and reinfocement: 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.2 With Modular bricks
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1- Hot finished welded type tubes.
Providing corrugated G.S. Sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. Limpet washers or with G.I. Limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surface), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1.1.00 mm thick with zinc coating not less than 275gm/m2
Providing ridges or hips of width 60 cm overall width plain G.S. Sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. Limpet and bitumen washers complete. 12.4.1 0.80 mm thick with zinc coating not less than 275gm/m2
15mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasker etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including/cleat angle, Aluminium snap beading for glazing/panelling and dash fasteners to be paid separately): 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. Brass/stinless steel screws etc.complete as per architectural drawing and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1cement:4 coarse sand) : 11.16.4 Ordinary cement without any pigment
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. Sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. intermediate channel with connectingclips made out of 2.64 mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling foxed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably. 12.45.1 12.5 mm thick tappered edge gypsum plain board conforming to IS: 2095-(Part-I) : 2011 (Board with BIS certification marks)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: 13.98.1 One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade: 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20mm, nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation necessary excavation, levelling & dressing & finishing the top smooth.
(B) Electrical Works: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.1 Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.2 Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.3 Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.1 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.3 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.4 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.5 6 pin 15/16 A socket outlet
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / lsolator) 2.3.3 12 way Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 2.12.1. 40 A
Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering PiPe etc. with charcoal/ coke and salt as required'
Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing as required.
Supplying with fitting fixing of AC ceiling fan complete with all accessories like down rod, canopy etc. 1200mm sweep (Usha/Bajaj) make
Supplyingwith fitting fixing of 20 Watt LED tube light luminaries.
Supplying with fitting fixing of 9 Watt LED bulb luminaries
NIBOL NARZARY
DHARAMSING NARZARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .