| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.8 CrAccepted-AOC | ₹4.8 Cr Quoted ₹5.0 Cr | L-1 | Accepted-AOC Work awarded due to lower rates quoted |
| 2 | L-2₹5.3 Cr+₹31.9 L (6.44%)Rejected-Finance | ₹5.3 Cr+₹31.9 L (6.44%) | L-2 | Rejected-Finance Rejecteddue to lower rates |
Tender Value
₹4.7 Cr
EMD Value
₹9.5 L
Closing Date
20 Nov 2025, 6:00 pmClosed
SOMVIR
Assistant Soil Conservation Officer Rohtak
Reclamtion of Water Logged and Saline Soil through Sub Surface Drainage Technology Project in the village Kiloi Khas, Block and District Rohtak
2025_HRY_482302_1
20258D2241B3 9A8B 4E06 99E0 B324CA9738062106AGR
Open Tender
Civil Works
Works
550 days
KILOI KHAS
Terms and Conditions mentioned in the DNIT
4 documents required · 4 mandatory
₹16,180
₹9.5 L
Yes
13 Jan 2026
10 Nov 2025
21 Nov 2025
10 Nov 2025
20 Nov 2025
10 Nov 2025
10 Nov 2025 - 12 Nov 2025
Amount
Perforated Corrugated PVC Pipes 178id/200od mm Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.Estimated weight 1690 gm/m( Without GST)
Perforated Corrugated PVC Pipes 144id/160 od mm Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS:9271:2004.Estimated weight 1140gm/m( Without GST)
Perforated Corrugated PVC Pipes 258/294mm Specifications as per IS:9271-2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.Estimated weight 2500 gm/m( Without GST)
Couplers( Jointer) 200 mm for Perforated Corrugated PVC Pipes 178 mm id/200mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 1690 gm/m( Without GST)
Couplers( Jointer) 160mm for Perforated Corrugated PVC Pipes 144id/160 outer dia mm Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 1140 gm/m( Without GST)
Couplers( Jointer) 294 mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 2500 gm/m( Without GST)
Saddle Bend 80mmX 294 mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Saddle Bend 80mmX 200 mm for Perforated Corrugated PVC Pipes 178 mm id/200 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Saddle Bend 80mmX 160 mm for Perforated Corrugated PVC Pipes 144 mm id/160 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Saddle Tee Combined 80mmX 160 mm for Perforated Corrugated PVC Pipes 144 mm id/160 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Saddle Tee (Combined) 80mmX 80mmX200mm for Perforated Corrugated PVC Pipes 178 mm id/200 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Saddle Tee (Combined) 80mmX 80mmX294mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST)
Couplers for Corrugated PVC Pipes 72/80mm Specifications as per IS-9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.
End Caps for Corrugated PVC Pipes 72/80mm Specifications as per IS-9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.
Control Panel Steel Box with lock Size 0.60 mtr x 0.50m x0.45 mtr of 6 mm G.I metal
Flange for pvc pipe
Rubber Jain Thickness not less than 3mm
Nipple for 100mm PVC pipe length 15 cm
Plastic Thread for Wrapping of filter around 80mm dia lateral pipes
Painting and Writing Name of SSD Blocks on Iron Doors of Fencing
Labour for staking, joints,cutting of pipe,changing of boom, following of trencher, connection of pipe to the mainholes, sump, carriage of pipes for manholes, unloading of pvc pipe etc
Wrapping, pulling the nylon sock of different size over the collector pipe for SSD Work
Wrapping the filter around the lateral pipe
1200 mm dia RCC Pipe with bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing (
1200 mm dia RCC Pipe without bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing (
900 mm dia RCC Pipe without bottom plugged, of length of 1.25 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing
900 mm dia RCC Pipe with bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing
Nylon Socks for Perforated Corrugated PVC Pipes 160 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with minimum overlap 25%
Filter Material for 80mm outer dia lateral pipe Specifications – the material should be non woven polypropylene, minimum thickness shall be 2.6mm confirming to thickness test prescribed in IS 13162(part5) at 1992, mass per unit area will be 300g/mm2, the strip width shall be 31cm ,the O90 apparent opening size may vary from 350-500 microns
Corrugated PVC Pipes 80mm. Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.Estimated weight 340 g/m
Nylon Socks for Perforated Corrugated PVC Pipes 160 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with maximum 4 % overlap
Nylon Socks for Perforated Corrugated PVC Pipes 200 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with maximum 4 % overlap
Nylon Socks for Perforated Corrugated PVC Pipes 294 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with maximum 4 % overlap
Installation of Sump RCC Pipes 1200 mm dia(2 pieces of length 2.5m each)vertically as per specification given in design
Installation of Manhole RCC PIPES 900mm DIA(2 pieces of length 2.5m and1.25m) vertically as per specifications given in design
3 HP DC Surface Solar Photovoltaic Water Pumping System (SPWPS) As per HAREDA Guidelines
-Installation/ Laying of Perforated Corrugated PVC Pipes 160mm outer dia Collector pipe in given slope as per specifications given in design at depth varying from 6 feet to 10 feet in village Asan
Installation/ Laying of Perforated Corrugated PVC Pipes 294mm outer dia Collector pipe in given slope as per specifications given in design at depth varying from 6 feet to 10 feet
Installation/laying of perforated corrugated PVC PIPES 200mm outer dia collector pipe in given slope as per specifications given is design at depth variying from 6 feet to 10 feet
Installation/laying of perforated corrugated PVC PIPES 80mm outer dia collector pipe in given slope as per specifications given is design at depth variying from 4 feet to 9 feet
SHREEKRISHNA MALLESHAPPA KONGI CIVIL CONTRACTOR TANGADAGI (BID ID -1370813)
SHREEKRISHNA MALLESHAPPA KONGI CIVIL CONTRACTOR TANGADAGI (BID ID -1370813)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_560294.xls
BOQ • 0.32 MB
OT0138477.pdf
Other Document • 1.13 MB
AgreementSSDRithalNarwal.pdf
Tender Documents • 3.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .