EEE-III/RZ
EEE-III/RZ
Improvement / Development of E.I. AND other allied works in Community Hall P Block Mangolpuri, ward no. 55 under Rohini Zone.
2023_NDMC_143330_1
EEE-III/RZ/TC/2022-23/16.9
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹7,200
7 Feb 2023
30 Jan 2023
7 Feb 2023
30 Jan 2023
6 Feb 2023
30 Jan 2023
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc.as required. (a) 5/6 amp switch
(b) 3 pin 5/6 amp socket outlet
(c) 15/16 A switch
(d) 6 pin 15/16 A socket outlet
S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface / recessed/ PVC/ Steel conduit as reqd. (a) 3 x 2.5 sqmm
(b) 3 x 4 sqmm
(c) 3 x 6 sqmm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size in the existing masonry open duct as required. Upto 35 sq.mm
Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following size on wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) (b) 100 Amp, 16KA, TPMCCB
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply of 1200mm sweep 50 watt, Energy saver ISI Marked BEE 5 Star rating AC Ceiling fan suitable for 230 V, 50 Hertz AC supply without regulator with blades, downrod etc. complete as required.
Rewinding of AC ceiling fan of all sizes and make i/c oiling, greasing as required. New Model (LIGHT WEIGHT)
Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
Replacement of fan condenser 2.5 mfd as reqd.
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:- (a) 2 x 10 sqmm
(b) 4 x 25 sqmm
Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required
Supply and fixing 3mm thick phenolic laminated sheet i/c cutting of sheet, bolt and washer etc as required.
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: (a) Total system wattage 20 watt +/- 5% (b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd. (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
S & F of compartmentalized cubicalpanel board duly powder coated made out of 16 SWG MS Sheet with Al. bus bar i/c interconnection copper wiring arrangement for mounting for switchgears, change over switches, MCCB i/c making the foundation brick work /angle iron frame on floor/wall with proper locking arrangement etc complete as required at site. upto depth 30cm.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .