| 1 | L1₹26.6 LAccepted-AOC ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹29.9 L+₹89,990 (3.10%)Rejected-Finance VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹33.5 L+₹4.5 L (15.5%)Rejected-Finance 1551 5 CHARANJEEV COLONY KAITHAL 1551 5 CHARANJEEV COLONY KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹33.5 L+₹4.6 L (15.7%)Rejected-Finance SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹34.3 L+₹5.3 L (18.3%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
24 Apr 2023, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR/MAINTENANCE OF WATER HEATERS PVC TANKS PPR UPVC PIPES AND ITS CONNECTED ITEMS IN OLD AND NEW NAVY NAGAR AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2023_MES_587227_1
8244/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and category a(ii)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹98,000
Yes
22 Jun 2023
27 Mar 2023
25 Apr 2023
27 Mar 2023
24 Apr 2023
17 Apr 2023
27 Mar 2023 - 24 Apr 2023
Amount
Disconnecting carefully water and electric connection from storage type geyser of 25 ltr capacity of any make and dismantling for repair/maintenance by taking out Siphon/geyser assembly, thermostat, heating elements, indication lamps and all necessary accessories and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geysers after cleaning & servicing including replacement of flexible 3 core PVC insulated and PVC sheathed copper cable of size 2.5 Sqmm up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note :- (a) Heating element, thermostat, indication lamps, safety valve, PVC cable, PVC plug top 15 Amps, steel tank & Siphon/geyser assembly shall be measured and paid separately under relevant item of sch as supply only. (b) The quoted rate includes the soldering/brazing/control wiring, air release valve, glass wool of superior quality, gaskets as required at site. (c) Only one time shall be paid to the contractor per particular geyser instead of number of times attending for repair/replacement of materials.
Supply only heating element of capacity 1500 watts suitable for any type/make of (triangle type/Circular type) existing 15/25 ltr geysers complete all as specified and directed.
Supply only thermostat suitable for 25 ltrs capacity water storage geyser with automatic thermal cut out fixed including testing complete all as specified and directed.
Supply only Copper Siphon assembly suitable for 25 ltr capacity water geyser with rubber packing and automatic thermal cut out complete all as specified and directed
Supply only safety valve for geysers chromium plated brass 15 mm dia complete all as specified and directed.
Supply only indication lamps suitable for water geyser 25 ltr capacity including testing complete all as specified and directed.
Supply only PVC connection pipe heavy duty suitable for hot water supply of size 15 mm with PTMT nuts ib both ends of length 450 mm with two washers suitable for Geyser 25/50 ltr capacity complete all as specified and directed.
Supply only PVC insulated and PVC sheathed flexible copper conductor cable of size 3 core 2.5 sqmm including testing complete all as specified and directed.
Supply only PVC plug top three pin 15 Amp, 240 Volts complete all as specified and directed.
Supply only steel cylinder suitable for Geyser of 25 ltr capacity, ISI marked complete all as specified and directed.
Attending ,repair of internal water supply complaints in old and new navy nagar area ,repair, replacemnt of unservicable bib tap,stop cock removal of airlock,tightening of leaking pipes/valves ,repair to concealed pipe line and other work pertains to internal water supply all as directed by Engr-in-charge.
Note: (a) Major items required to be replaced will be measuered and paid separtely under revelant schedule. (b) Complaints should be taken from complaint cell or also through telephone by JE E/M and AGE W/S by your representative every day. (c) Complaints should be attended immediately ans shall report the JE E/M/Engr-in-charge after completion with 6 Hours. (d)In case the nature of job is such that the work cannot be completed within a period of 6 hours then the same shall be brought to the notice of the AGE W/S /GE and the period for the completion of the complaints shall be decided by the GE/Engr-in-charge. (e) Contractor representative /Engieer will report to JE E/M in charge or AGE E/M at forenoon and afternoon to collect routine urgent works till completion of the CA . (f) The transportation /T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same. (g) Contractor should provide regular team attending complaints.
S&F in repair PVC water storage Tank 5000 ltr capacity 2 layers , ISI marked, hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed.
S&F in repair PVC water storage Tank 3000 ltr capacity 2 layers , ISI marked, hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed.
S&F in repair PVC water storage Tank 2000 ltr capacity 2 layers, ISI marked,hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed.
S&F in repair PVC water storage Tank 1000 ltr capacity 2 layers, ISI marked,hosting and fixing in position at any location removing existing tank disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection including replacement of tank nipples and GI fittings as required at site complete all as specified and directed.
Disconnecting of existing water supply pipe lines from PCC tanks, Cutting and removing the existing 5000 Ltrs PCC tank with concrete cutting machine carefully without any damage to existing structure of the buildings and providing PCC foundation not less than 30 cm height, supply and fixing new PVC water storage Tank 5000 ltr capacity, 2 layers , ISI marked, hosting and fixing in position on PCC platform and making all incoming & out going connections,GI nipples, fittings as required at site, testing all as specified and directed. Note :- 1. Removing of old PCC material from the station is also in the contractor's scope and rate included in the item rate. 2. The rate also includes the disconnecting of Motor actuated butterfly valves and sensors carefully and its refixing in PVC tank, testing complete.
Taking up or down steel tubing/CPVC/PPR Pipe and connections complete of the following sizes all as specified and directed :- Note :- Serviceable tubes shall be re-used, measured and paid for separately under relevant item of sch 'A'
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Supply and Fixing in repair of internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, clamps, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge of following sizes :-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Supply & Fix in repair 3 layer PP-R (polypropylene random co poloymer) pipes ,green and blue colour ,SDR 11UV stablized and antimicrobial welded having thermal stablity for hot and cold application including all PPR fittings, unions, clamps to walls,ceilings or shaft of building up to G+15 all specfied and directed by Engineer-in-charge of following sizes:-
(a) 16 mm bore (20 mm outer dia)
(b) 20 mm bore (25 mm outer dia)
(c) 25 mm bore (32 mm outer dia)
(d) 40 mm bore (50 mm outer dia)
(e) 50 mm bore (63 mm outer dia)
Supply & Fixing in repair to concealed unplasticised PVC pipes of pressure rating 10 kg/Cm2 fixed complete to wall ,ceilings or in floor etc with clamps.any type of pipe of following size:-
(a) 15 mm bore (Inner dia)
(b) 20 mm bore (Inner dia)
(c) 25mm bore (Inner dia)
(d) 40 mm bore (Inner dia)
Refixing old water tubing of any size, any nature and connection in new or old position (walls,ceiling,floor,etc) after cleaning including all fittings and fixtures of following sizes complete all as specified and directed :-
(a) 15 mm bore
(b) 25 mm bore
(c) 40 mm bore
Supply & fix in replacement of PVC loft tank (LDPE) of capacity 275 ltrs with complete fitting including 03 Nos adapter with washer for inlet/outlet,over flow nipples as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair/replacement PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
Supply and fix in repair/replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out in high raised buildings on plain wall with necessary bamboo scaffolding /safety measures complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs CP bib tap with crutch or butterfly handle screwed both ends suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified .
Supply and fix in repairs CP stop cock , screwed down high pressure with crutch or butterfly handle screwed both ends suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified .
Supply and fix in repairs concealed type stop cock for GI tubing 15 mm dia or 20 mm outer dia CPVC pipe including necessary fittings,clamp & saddles etc all as specified.
Supply and fix in repairs angle cock for GI tubing 15 mm dia or 20 mm outer dia CPVC pipe including necessary fittings,clamp & saddles etc all as specified.
Supply and fix in repairs CP Brass mixer of size 15 mm for mixing hot & cold water screwed down for iron pipe including necessary fittings,clamp & saddles etc all as specified.
Dismantling of existing connection and taking out pressure reducing valve of size 25 mm bore cleaning servicing and refixing at existing location in upto buildings (G+14) including provision of fittings, I.e. union, elbow, bend, nipple, etc. complete to make the line functional all as specified.
Supply and fixing in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms including necessary GI fittings as required at site i.e. elbow, reducer, nipple etc complete all as specified and directed for the following sizes :-
Supply and fix in repair gun-metal, gate valve in existing line in position with iron wheel head class I, made out of brass, screwed both ends for GI pipe with union, ISI marked complete all as directed of the following size :-
(a) 15 mm bore
(b) 40 mm bore
(c) 50 mm bore
S&F in repairs shower rose CP 125mm dia swivel type suitable for 15mm bore GI tubing complete
S&F in repairs Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour complete all as specified and directed
Checking of over head tanks of any capacity , making arrangement of mosquito proofing of the tank from overflow side with new GI tank nipples, socket, barrel nipple , elbow, MS wire net, locking the existing tank cover to avoid entry of lizards, mosquitos inside the tank, tightening of all inlet and out let connections to make the tank no leaking of water complete including painting with white colour paint on base coat and writing the letters of black colour of the following details all as specified and directed :- (a) Date of cleaning (b) Date of Next due (c) Tank capacity
S&F in repair FRP lid cover for PVC water storage tank complete accessory for closing and locking arrangement suitable for various capacitys as approved by BMC
(a) For capacity of 5000 litres
(b) For capacity of 3000 litres
Supply and fixing in repairs, Cross arms, bracings, supports, clamps for pipe lines, ladders, staging for water tanks, sheets for chamber covers/for staging and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of pain complete all as specified and directed.
M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water and providing sticker showing the date of cleaning complete all as specified. Note : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost.
Cleaning of PVC and RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completly and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land and complete all as specified and as directed by Engineer-in-charge . Note: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified.
(a) OH Tank of capacity 5000 Litres
(b) OH Tank of capacity 3000 Litres
(c) OH Tanks of capacity 10000 Litres
Disconnecting of electrical connections of 400 KVA DG set at Asvini area carefully from LT Panels complete , including shifting of DG set 400 KVA & AMF panel with the help of Hydra for Loading and unloading and suitable truck for carrying the DG set from Asvini area to MT section of GE(NW) Navy Nagar and fixing of DG set on PCC platform, AMF panel with cable connections with suitable lugs and glands, testing complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
M&L in replacement for earthing complete with galvanized earth plate 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level connecting with 32 x 6 mm GI strip by means of bolts nuts, check nuts and washers of galvanized iron all shown in electrical plate No 03 of SSR Part-I including necessary excavation earth work using PCC 1:2:4 for earthing pit and pit cover with handle of 8mm dia MS rod and connected to test point all as specified and directed. Note : (a) The item rate inclusive of fixing of earth continuity conductor from earth plate upto 7.5 mtr. (b) The item rate inclusive of provisioning necessary charcoal and salt upto the level of the earth plate in alternate layers.
Rama Construction Co
m/s riya construction co.
Haryana EngineerService
BOB ENTERPRISES
P LAXMI AND CO.
M/S V N ENTERPRISES
SHREE JAGDISH FURNITURE CO.
S S ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .