Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.0 CrAccepted-AOC 7 3 PUDUMARAPPANUR ARIYUR POST NAMAKKAL 637 015 TAMIL NADU | NAMAKKAL | TAMIL NADU | 637015 | ₹87.0 Cr Quoted ₹91.5 Cr | L1 | Accepted-AOC Lowest Rate Quotated by L1 Tenderer accepted |
| 2 | L2₹93.2 CrRejected-AOC 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹93.2 Cr | L2 | Rejected-AOC highest Rate Quotated by L2 Tenderer |
| 3 | L3₹95.0 CrRejected-AOC NAMAKKAL | ₹95.0 Cr | L3 | Rejected-AOC highest Rate Quotated by L3 Tenderer |
Tender Value
₹87.1 Cr
EMD Value
₹43.7 L
Closing Date
5 Sept 2023, 1:00 pmClosed
Joint Commissioner/Executive officer
ARULMIGU SUBRAMANIA SWAMY TEMPLE, THIRUCHENDUR - 628215
REDEVELOPMENT OF INFRA STRUCTURE FACILITIES AROUND ARULMIGU SUBRAMANIA SWAMY TEMPLE, THIRUCHENDUR - THOOTHUKUDI DIST
2023_HRCE_354169_1
4334/2019/A3
Open Tender
Civil Works - Buildings
650 days
Tiruchendur
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹43.7 L
Yes
15 Dec 2023
3 Aug 2023
5 Sept 2023
4 Aug 2023
5 Sept 2023
4 Aug 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Upto 2 Metre depth below average ground level.
Upto 2 Metre to 3 Metre depth
Upto 3 Metre to 3.5 Metre depth
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling basement with conveyed earth from 10 km
Supplying and filling with GRAVEL including cost and conveyance of gravel and all labour charges for filling ramming etc.,complete with standard specifications.
SHUTTERING WORKS
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Footing and Grade beam Shuttering
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
CONCRETER
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 10 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification.
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
In foundation and basement
In Ground floor
In First floor
In Second Floor
In Third Floor (Terrace)
In Fourth floor
In Fifth f floor
Plain Cement concrete, 1 : 2 : 4 ( One cement, two sand and four jelly) using 20 mm size hard broken granite stone jelly for flooring base including consolidating as per standard specification, rendering the top surface rough to recive the floor finish and curing etc., complete complying with standard specification.
IRON AND STEEL WORKER
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
MASONRY WORKS
Brick work using Fly Ash bricks of size 230 x 110 x 70mm (visually the blocks shall be sound compact and uniform in shape free from visible cracks, warpage, flaws and organic matter. The bricks shall be solid with frog on one of its bearing side). Class designation not less than 140 Kg/sq. cm average compressive strength in Cement Mortar 1:6 (one cement and six sand) including neat finishing, curing, etc, complete complying with standard specification.
for foundation and Basement CM 1:5
In Ground Floor CM 1:6
In First Floor CM 1:6
In Second Floor CM 1:6
In Third Floor CM 1:6
In Fourth Floor CM 1:6
In Fifth Floor CM 1:6
Brick work Partition using Fly Ash bricks of size 230 x 110 x 70mm (visually the blocks shall be sound compact and uniform in shape free from visible cracks, warpage, flaws and organic matter. The bricks shall be solid with frog on one of its bearing side). Class designation not less than 140 Kg/sq. cm average compressive strength in in Cement Mortar 1:3 (one cement and three sand) including fixing hoop iron reinforcement if found necessary, finishing and curing, etc., as directed by the departmental officers. (Cost of hoop iron reinforcement will be paid separately). 11.50 cm thick
In Ground Floor
In First Floor
In Second Floor
In Third floor
Fouth floor
PLASTERING WORKS
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12 mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
WATER PROOFING
Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime in the proportion of brick jelly to lime being 32 to 12 1/2 by volume and laid over the RCC roof slab in a single layer and consolidated to the finished thickness by beating the concrete with wooden, beaters of approved pattern keeping the surface constantly wet by sprinkling jaggery and lime water etc. complete complying with standard specification.
Finishing the top of roof with one course of approved first quality Machine Pressed Tiles of size 230mm x 230mm x 20mm thick of approved quality laid in Cement Mortar 1:3 (one cement and three sand) 12mm thick mixed with water proofing compound confirming to Indian standard as approved by the departmental officers at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same mortar mixed with the water proof compound and red oxide etc. complete complying with standard specification.
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixedinto the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. M - 0625
PAINTING WORKS
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing zinc cromate priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Engineer before use on works.)
WOOD AND JOINERYS
Supplying and fixing Solid Core Flush Shutters 35 mm thick with teak wood lipping alround the door with teakwook lipping etc., complete complying with standard specifications.
Supplying and Erecting Pull and Push Type RollingShutter with ISI make of approved size and sectionusing 18 GI sheet. The shutter shall be painted withone coat of red oxide primer and the rate is inclusive ofhood covers, transportation charges etc
ROLLING SHUTTERS (WITH ISI MONOGRAM) .
a Manually Operated (up to 8 sqm. Area)
Supplying and fixing in position C . W . Scantlings upto 4 m in length including Labour wrought and put up in position of frames inclusive of fixing holdfasts for doors, windows, ventilators etc.,.as directed by officers incharge .
Supplying and fixing in position T . W . Scantlings over 2 m & below 3 m in length including Labour wrought and put up in position of frames inclusive of fixing holdfasts for doors, windows, ventilators etc.,.as directed by officers incharge .
Supplying and fixing in position T.W fully panelled foldable door Shutters size 3.00 x 2.40 M
Supplying and fixing of fibre reinforced polymer shutter with F.R.P.door frames made out of F R P sheets of 3 mm thick of overall size 65 mm x 50 mm with rebate suitably reinforced using M S angles / flats cost of holdfasts and solid core F R P shutter panel of 5 mm thick and hpllow core frames of 3 mm wall thickness for styles and rails etc, and overall provision for hinges with core filling either with agro based materials (or) fibre proof foam (in case of lights weight) and the shutters provided with good quality seasoned treated hard wood cleats wherever found necessary for fixing furniture fittings like, alu. hinges, alu. tower bolts, alu. aldrop (to match finish of the door shutter) etc., complete complying with standard specifications. The rate shall be inclusive of all alu. fittings. and labour charges.-Single leaf.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work sqm. 7482.00
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing mild steel grills for windows, ventilators, rtc., including priming coat
Supply and erection of Double Leaves Fire Rated Door with Frame having the dimension of 1800mm x 1400mm with following specification: a. Door Frame 1.6mm: Galvanized 120 GSM branded make JSW b. Door Leaf 1mm: Galvanized 120 GSM branded make JSW c. Shutter Thickness: 46mm d. Honeycomb: In-fill e. Glue Macroplast UR-7221 f. Door Hinges: 4" x 3" x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS 304 - Finish SS g. Door Closer with Standard Arm Finish: Silver h. Lock Set: Dead Lock with both side key i. Door Orientation: To be confirmed by client j. Mounting of door: Brick wall mounted k. Powder Coating: Powder coated in standard RAL paint colour of PO Red (60 to 90) Microns l. Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalent m. Dead Lock with both side key: Make Assa Abloy Yale or Equivalent n. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame o. Rated Glass Schott Pyran with Frame p. Anchor Bolt with Endcaps The above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, pastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers
Manufacturing supplying and fixing of steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete.
Fabrication, supply and fixing in position of 'N' type ventilators using M.S. angle of size 25 x 25 x5 mm for frame and M.S. Flat of size 20 x 3 mm for fixing the weld mesh and using 25 x 22 x3 mm 'T' section for frame glass. Special type of Hold fast welded to the frame of 45 degree inclined towards centre for wall and fxing the weldmesh 25mm square including cost of 3mm thick pinheaded glass panes for all panels and fixing the glass panels with necessary clips & putties with required bolts, nuts and washers and one coat of red oxide primer etc. including necessary dismantling, making holes in RCC columns, beams, masonry wherever necessary with power drill to the extend required and made good to the original conditions after fising as directed by the departmental officers.
Supplying and fixing of PVC Sliding door with Roller manual sliding door of size 1000 mm x2100 mm
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed
FLOORING WORKS
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Flooring with following joint free rectified ceramic tiles of size 305 x 305 x 8 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best quality Double charged vitrified Tiles of size 600 x 600 x 8 mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20 mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by the Engineer in charge before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 4' x 2' and above of 18 to 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Engineer concerned before use on work, etc., complete as per standard speicification.
Dadooing the walls with joint free ceramic tiles of all colours of approved quality and brand (colour/shade of the ceramic tile should be got approved by the departmental officers concerned before use on work) of size 300 x 450 x 8 mm set in cement mortar 1:2(One cement and two sand) 10mm. thick and pointed with colour cement at the rate of 0.4 kg/sqm. (white cement mixed with colouring pigment) to suit the colour and shade of the ceramic tiles used neatly and fixed in position without any air gap in between the ceramic tiles etc., complete complying with standard specification and as directed by the departmental officers.
Dadooing walls with granite tiles of synthetic grey, paradise, and similar varieties of suitable sizes of Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2'0" x 1'0" or 1'0" x 1'0" or 1'0" x 0'6" of 10 mm thick best approved quality, set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 40 mm thick
FALSE CEILING
Supply and installation of Anutone (or) Euivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm,length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15.Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directe by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication. M-0622
TRUSS WORK ROOF
Design,Supplying, fabricating and fixing in position inserts comprising edge angle, MS angles, plates, tees, flats and other structural steel sections, holding down bolts, anchor bolts, anchor plates, pipe sleeves etc., in all cement concrete works at all levels and heights above finished floor level in foundation, trenches, pits, tunnels, lift pits etc., below finished floor level including cutting, bending to shape fabricating, drilling, threading, welding lugs etc., with all tools, tackles and labour as per design or as directed including a coat of primer of approved quality and painting the exposed surface with two coats of synthetic enamel paint of approved quality and colour etc., all complete as per drawings and as directed.
ROOF SHEETING - COLD WELL -1 PUFF PANEL for 50 mmMicro Ribbed finish on inner and outer sheet. with micro ribbed GI Sheet with CFC Free pentane Blown Polyurethane foam as the core
Supplying and Fixing of Rigid PUF Cold well panel made out of Inner and outer in micro ribbed GI Sheet with CFC Free pentane Blown Polyurethane foam as the core which is injected between the 2 sheets with highly sophisticated computer controlling foaming machine .The Panel is manufactured by using continuous foaming method COLDWELL PUFF-1PANEL PREFABRICATED Polyurethane sandwich panels comprising of exterior and interior with micro ribs and 1000 mm cover width made out of top 0.5mm /0.5 mm bottom PPGL-550Mpa/150GSM/RMP stregth colour coated galvanized steel,120 GSM Zinc coating with 20 microns polyester paint Core- CFC/HCFC free Pentane BlownPolyurethane foam density of 40 Kg/m3 in 50 mm thick shall be supplied in 1 mtr width.
PLUMBING AND SANITARY FITTINGS
Supplying and fixing in position best Indian make wash hand basin of size 550mm X 400mm and approved brand and quality with a pair of C.I. Brackets fixed to wall with necessary teakwood plugs and brass screws one No. of 15mm C.P. Pillar tap, 32mm C.P. Waste coupling, rubber plug and chain, 32mm G. I. Union, 32mmG. I. Waste pipe, 15mm dia G. M. Wheel valve 15mm brass nipple and nylon connection including cost of white lead TW Plugs clamps, rubber washer, etc., complete. (The wash hand basin should be got approved from the Engineer before use on works). White glazed earthern ware wash hand basin without pedestal
Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Engineer before use on woks)
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Engineer before use on works).
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Engineer before use on works).
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap short body (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Engineer before use on the works)
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Engineer before use on works above Ground level
External water supply arrangements.
50 mm dia. U P V C. Pipe
40 mm dia U.P.V.C pipe
Internal water supply arrangements.
40 mm dia U.P.V.C pipe
32 mm dia. U P V C. Pipe
25 mm dia. U P V C. Pipe
20 mm dia. U P V C. Pipe
100 mm dia C.P.V.C pipe
80 mm dia C.P.V.C pipe
65 mm dia C.P.V.C pipe
50 mm dia C.P.V.C pipe
40 mm dia C.P.V.C pipe
32 mm dia. C P V C. Pipe
25 mm dia. C P V C. Pipe
20 mm dia. C P V C. Pipe
Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve / Wheel Valve heavy type with ISI mark of the following sizes including cost of shellac, thread, including labour charges for cutting and threading of GI pipes as directed by the departmental officers etc., complete complying with standard specification for both internal and external water supply arrangements. The gate valve/ wheel valve should be got approved by the departmental officers before use on works.
65 mm dia Gun Metal Gate Valve
50 mm dia Gun Metal Gate Valve
40 mm dia Gun Metal Gate Valve
32 mm dia Gun Metal Gate Valve
25 mm dia Gun Metal Gate Valve
20 mm dia Gun Metal Gate Valve
Supplying and fixing in position the following U P V C specials of best approved quality and heavy type and good variety excluding fixing charges, but including cost of cutting and threading the Pipes for jointing the Specials etc., complete complying with standard specification.
80 mm dia Bend.
65 mm dia Bend.
50 mm dia Bend.
40 mm dia Bend.
32 mm dia Bend
25 mm dia Bend
20 mm dia Bend.
Reducer Elbow .
50 X 40 mm dia Reducer Elbow
32 X 25 mm dia Reducer Elbow
25 X 20 mm dia Reducer Elbow
20 X 15 mm dia Reducer Elbow
Coupler .
65 mm dia coupler
50 mm dia coupler
40 mm dia coupler
32 mm dia coupler
25 mm dia coupler
20 mm dia coupler
Hex Nipple .
50 mm dia Hex Nipple
40 mm dia Hex Nipple
32 mm dia Hex Nipple
25 mm dia Hex Nipple
20 mm dia Hex Nipple
65 mm dia Tee.
50 mm dia Tee.
40 mm dia Tee.
32 mm dia Tee.
25 mm dia Tee.
20 mm dia Tee.
Elbow .
50 mm dia Elbow
32 mm dia Elbow
25 mm dia Elbow
20 mm dia Elbow
Reducer
80 X 65 mm dia Reducer Tee.
80 X32 mm dia Reducer Tee.
65 X 50 mm dia Reducer Tee.
65 X 40 mm dia Reducer Tee.
65 X 32 mm dia Reducer Tee.
50 X 40 mm dia Reducer Tee.
50 X 32 mm dia Reducer Tee.
50 X 25 mm dia Reducer Tee.
40 X 32 mm dia Reducer Tee.
32 X 25 mm dia Reducer Tee.
32 X 15 mm dia Reducer Tee.
25 X 20 mm dia Reducer Tee.
20 X 15 mm dia Reducer Tee.
Supplying and fixing in position best approved quality PVC Nahini trap of 110 mm x 75 mm size with stainless steel gratings of approved quality fixed over a bed of lime concrete.1:2:5 (one lime two sand and five brick jelly) using 40mm broken brick jelly including dismantling the flooring concrete / Brick masonry wherever necessary and redoing the disturbed portion to the original condition and giving in connection to the PVC soil (stacks) pipe as directed etc., complete complying with standard specifications. (The PVC Nahini trap should be got approved from the Engineer before use on works).
Supplying and fixing in position PVC Pipe of 6 kg per sq.cm. best approved quality and make conforming to ISS of the following diameter and providing leak proof joints etc., including fixing to the wall with necessary teakwood plugs, brass, screws, mild steel clamps, etc., and giving connections to the sanitary fitting including dismantling brick masonry RCC floor or roof slab etc., wherever necessary and redoing the disturbed portion to the original condition complete complying with standard specification (The PVC pipe should be got approved from the Engineer before use on works).
110 mm dia PVC pipe - Above ground level
75mm dia PVC pipe - Above ground level
50mm dia PVC pipe - Above ground level
160 mm dia PVC pipe - Above ground level
160 mm dia PVC pipe - below ground level
200 mm dia PVC pipe - below ground level
Supplying and fixing in position 100 x 75 mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150 mm and 230 x 230 mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three crushed stone sandand Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Engineer before use on works.
Supplying and fixing in position best approved of ISI quality of PVC rain water down fall pipes having a pressure of 4 Kg./sq.cm including cost of necessry PVC shoe, PVC bend, gratings of required diameter and special clamps, brass screws, nails, etc. and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc. complete. The rate shall be inclusive of cast of removable iron grating. The PVC pipe shall be fixed in wall with special type of clamps. Special type of "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0 M pipe length complying with standard specification.
110 mm dia.
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
supplying and fixing if marble of 0.61*1.22m.,18/20mm thick in all floors for urinal partition including for labour charges for fixing and polishing etc.,
CP Two Way Bib Cock with Health Faucet
Supplying and fixing SFRC manhole cover with SFRC frame, cover weighing not lesser than the following and being a size of 600 x 600 mm for under ground sump including painting with two coats of anticorrosive paint over a coat of primer etc. Rate shall include providing and fixing locking arrangements as per specification and as directed.
600 x 600 mm Size
ROAD & PAVEMENT WORKS
Providing and laying Granular sub-base (GSB) in layers of not exceeding 250 mm compacted thickness on the prepared sub grade using approved graded hard broken stone jelly to the grading conforming to Table-400-2 of MOST to give a minimum soaked CBR value of 30 including sceening, spreading in uniform layer with grader, watering and premixing at optimum moisture content, compacting with power and vibratory rollers of 80 to 100 KN static weight to not less than 98% of the maximum laboratory dry density as per IS-2720 (Part8) and fine dressing to required grade and cross slope as shown on the drawing or as directd by the Engineer, including obtaining and transporting all materials from approved quarry site to work site with all lifts and lead by mechanical trasport head load or any other method of transportation, including labour, tools, equipment, safety measures, testing and incidentals necessary to complete the work as per technical specifications and as directed by Engineer.
Providing and laying Wet Mix Macadam in two layers of 75mm thickness to a specified total thickness of 150mm, compacting each layer with 8-10ton vibratory power roller. Each layer shall be rolled including premixing in well graded crushed stone aggregate, with watering and spreading to required profile and compacting with vibratory roller including all material, labour, machinery with all leads and lifts etc.complete. The mix shall be spread either by paver finisher or motor grader, compacting each layer with 8-10 ton vibratory power roller to obtain the 98% of modified proctor density including all labour charges, testing charges and including hire charges of all tools and plants employed and all the incidental charges etc; unless otherwise specified rest of all complete as per MORTH-IV specifications (table 400-11).
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. 16.54.1 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity 50 mm Thick
Providing and laying Bituminous concrete (Modified bitumen) on prepared surface with specified graded stone aggregate for wearing course including loading of aggregate with loader, hot mixing of stone aggregate, filler and bitumen in hot mix plant capacity not less than 30/40 TPH with electronic controls, transporting the mixed material by tippers to paver and laying the mixed material with paver finisher fitted with electronic sensing device to the required level and grade, rolling with vibratory roller of 80 to 100 KN static weight or by 3 wheeled road roller to achieve the desired density including preparation of base, geosynthetics, stress absorbing layer, mixture design, spreading, opening to traffic, surface finish, quality control, arrangments for traffic, any lead, including making good the undulations etc. Rate shall be inclusive of dewatering, cost of materials, labour, transportation, loading and unloading, tools & plants, watering, all other incidental charges etc., Work shall be carried out as per the instructions of Engineer-in-charge and in accordance to drawings, technical specifications and MORT&H specification section 509 & 521.30 mm/ 40mm thickness as per GFC. compacted thickness with bitumen of 80/100 grade @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of total mix)30 mm thick
Providing and laying Prime Coat over WBM/ WMM surface using 7 Kg of Emulsion Bitumen (SS1) per 10 sqm for preparatory to another bituminous construction over it, including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc.,complete as perClause 502 of MORTH Rev-5
Providing and laying bituminous Tack coat with bituminous emulsion as per IS:8887 all complete as per Technical Specification Clause 503 cleaned with mechanical broom on granular surface @ 0.25 to 0.30 Kg/Sqm
Kerb and Pavement works
Supply and fixing of Pre-cast concrete kerbs of 600 x 450 x 150 mm thick Grey color, curved edge, Matte finish with 4mm wide, 2mm deep recessed ponted groove joint in cement morter 1:4, make: Super pavers or equivalent on cement concrete base of 1:2:4mix as per dwg, cost including all materials at site, all labour charges and other necessary charges to complete.
Providing and laying of Precast concrete pavers of size 200mmx100mmx63 mm thick, shot blasted, Approved colour as given in below, approved make interlocking pavers laid over 50mm thk 'M' sand bed and compacting with plate vibrator having 3tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final evel. pattern as per landscape architects details. The cost including of all materials at site, all labour charges, cutting the pavers using machine tools at ends or trims and other charges as required to complete.
Providing and fixing in position of 20mm thick, size not less than 600 mm x 600 mm or 900 x 900 mm, grey colour flammed granite, flame finish machine cut straight edge, set in 50mm thick cement mortar 1:5 as per approved pattern/design including finishing the joints with cement slurry. The rate shall be including the cost of all materials, labour charges and other necessary charges required to complete.
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact. 2000 ltrs
Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confiriming to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation with continous S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP (above 20 HP). The motor offered should be of energy efficient motors. PAge 110 TWAD
Construction of valve chamber as per consultant drawing & river sand etc. complete.Cost included for civil materials and other plumbing materials,sand,stone and cement.Chambers shall be in brick work as per the following specification.Earth work excavation in all type of soil except hard rock with initial lead and lift, river sand filling, P.C.C.1:4:8 for foundation using 40 mm metal jelly, R.C.C.1:1.5:3 using 20 mm metal jelly for foundation bed concrete thickness as per the drawing, Brick work in CM 1:4 mix for walls thickness as per the drawing given,work including scaffolding ,shuttering charges for all R.C.C.works, wall plastering with CM 1:3, mix 15 mm thick for inside and outside wall.bed benching with P.C.C.1:2:4 mix using 20 mm metal jelly,thickness as per the drawing given.over the bed benching water proof compound mix plastering in CM 1:3 , 15 mm thickness. Approved FRP / GRP make Medium duty Frame with cover.
1500x600x1000mm deep & Manhole cover(750x600- 2 nos)
1500X900 X1000 mm deep & Manhole cover(750x900- 2 nos)
1500x1200x1000mm deep & Manhole cover(750x600- 4 nos)
Construction of inspection chamber as per the following specification. Contractor shall submit the details and drawings for the approval of Project Manager prior to execution. Masonry: First class Brick work 1:5 Wall thickness : 230mm upto 1.5m depth & 345mm more than 1.5m depth Bed concrete: PCC 1:4:8 & 200mm thick upto 1 to 2m depth and 300mm thick for more than 2m depth Plastering : 20mm thick,1:3 inner & outer side of the chamber wall Benching : Provide benching with PCC 1:3:6 Steps : Insulated Cast iron steps with the interval of 300mm if the depth is equal or more than 0.8m Water proofing : If the water table is high, two layer of water proofing need to do in inner & outer side of the chambers Constrction : Providing opening for manhole cover frames, excavation & backfilling around the chamber with the same material. Including SFRC Manhole cover
600x600 depth upto 800 mm
750x750 depth Above 800 to 1500mm
900X900 1500 upto 2000 mm
Providing, laying, jointing and testing socketed and spigotted RCC pipes (NP3 class) conforming to IS:458 collars jointed with stiff mixture of cement mortar in the proporation of 1:2 (1 cement : 2 find sand) laid to correct levels below ground in trenches upto required depth including excavation in all kind of soil (hard / soft), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required.
For road crossing areas:
300 mm dia R.C.C. Pipe
SEWAGE SUBMERSIBLE PUMP
Supply and delivery of submersible centrifugal sewage non-clog pumps, vertical spindle type pump , wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction, Liquid passages shall be finished smooth and designed as to allow free passage to solids. Pump Impeller should be of Non-clog semi open type , single vane / multi vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided to protect the motor from ingress of sewage along the shaft. The critical speed of the rotor shall be at least 30% above the operating speed. Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, duck foot bend, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 9600 rpm for high duty pumps and 960/1450 rpm for low duty pumpsets. Casing and impeller should be of CI Gr. FG 260 :IS210 more preferably with hardened impeller.Shaft should be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410.The submersible motor shall be operated with 3ph, 415 V(+or– 10%), 50Hz(+or-5 %) dry induction type. Motor shall be capable of giving rated output without reduction in the expected life span when operated continuously. The rotating assembly shall be dynamically balanced as per standards. The starting current of the motor shall not exceed 200% of rated full load current for Star / Delta or ATS starting under any circumstances .The motor shall be suitable for full voltage star delta / ATS starting. The locked rotor current of the motor shall not exceed 600% of full load current unless otherwise specified. Motor shall be designed to withstand 120% of rated speed for two minutes without any mechanical damage, in either direction of rotation. The motor vibration shall be within the limit specified in applicable standards . Motor should be of IE2, explosion proof compatible for VFD operation together with star-Delta /ATS starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shall be provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit.
Insulation class shall be of “Class H” and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC insulated and PVC sheathed, copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air. The control cable of PVC insulated, PVC sheathed, flexible for stator winding temperature sensor 3core x 1.5 sq.mm copper conductor and for bimetallic switches 2core x 1.5 sqmm copper conductor shall be provided. Motor shall be supplied with 10m of round submersible copper cable of suitable size. The non clog submersible pumpset shall be provided with suitable starter control panel having all protections as mentioned above. (upto 5 HP - DOL Starter, above 5 HP to 25 HP -Star Delta Panel and beyond 25 HP shall be ATS)
Discharge 300 to 400 M3/hour 1 No TWAD 22-23 Page 30
WATER TREATMENT PLANT
Raw water Transfer pump (FILTER FEED PUMP)
Supply, Delivery, erection and commissioning of Batch type electro chlorinator using common salt as raw material, consisting of electrolyzers cell made of Titnium with coating mixed metal oxide such as Anabium, Cadmium, etc, capable of producing sodium hypochlorite solution within time span of 8 hours, having adjustable metering cum dosing pump capable of dozing the prepared sodium hypochlorite solution in water supply system with sensor having auto shut down when the storage if FRP tank gets empty. The storage vessel and electrolyzer tank (hypo procesing tank)must be made of FRP tank coated inside with hypothalic -BIS standard, having capacity to store required quantity of hypochlotrite solution, water and common salt for electrolysis process respectively. The eclectrochlorinator must have power source or control module for producing necessary DC current for electrlyser process from 440v, 3 phase / single phase AC supply and must have auto cut off after batch time of 8 hours. For all power connection, copper cables should be used. Page 94 TWAD 2022-2023
Sthapathy Works
Ornamentel 'Brick work in Combination Mortar 1:4 (one of cement , and Four sand) using best quality Chamber bricks of size 8 3/4" x 4 1/4"x 2 1/4" for all Varivargams, moulds, sthambams, mukapathrams,koodu,Nasi and all ornamental works complete all pancharams,agaris, karnakoodus etc.,
(a) Vimanam / Gopuram of height up to 15' 0'' ( excluding kalkaram)
Providing Vargapoochu over the core walls of Rajagopurams / Vimanams with in Combination mortar 1:4 (one of cement ,and Four sand) complete including shaping the Mugapathrams, Mahanasi, Koodu, all Ornamental works to proper shape complete for Vimanams upto 100' 0" Height The lime used should be sourced from Pollachi which is highly iron fortified and suitable for structural and masonry works ..
(a) Vimanam / Gopuram of height up to 15' 0'' ( excluding kalkaram)
Providing New Sudhai Vigrahams in the Vimanams and Rajagopurams with Galvanised Iron Rod reinforcement of suitable dia with binding wire wherever necessary shaping the core with broken bricks set in C.M. 1:3 fininshing the same with C.M.1:3, bringing to the correct shape (Lakshana) in confirmity with silpa sastra inclusive of special ornaments, weapons, peedam etc., complete and providing C.M. Nayamtheervai wherever necessary, inclusive of cost and conveyance of all materials, such as cement broken bricks, sand, G.I.rods, binding wire, all labour for working in heights , curing lifting of materials etc., complete including Panchavarna Painting 3 coats (Each Vigraham is accountable with One Head, Four Handas, with weapons, Ornamental costumes etc., as per Prathima Lakshana, Vigraham height is measurable from the crown top to the bottom of foot only. If Peedam is provided the rate with Peedam may be adopted as detailed here under)
Sudhai Vigrahams of size above 2' 6" and Upto 3' 6"
Sudhai Vigrahams of size above 3' 6" and Upto 4' 6"
Providing Scaffolding for Gopurams / Vimanams with Casurina posts, Coconut or palm trees wherever necessary for main form work complete
(a) Vimanam / Gopuram of height up to 15' 0'' ( excluding kalkaram)
MISCELLANEOUS WORKS
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Supplying and fixing of SS Sink of size 1200 x 550 x 180mm
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
Pre-cast plain cement concrete slab in C.C 1:2:4 (One cement two sand and four aggregate) using 20mm gauge machine broken granite jelly for precast slab of following thickness including moulding casting finishing curing fixing in position true to alignment and pointing with cement mortar 1:3 (One cement and three sand) to full depth of slabs etc., complete
50 mm Slab
75 mm Slab
SECTION - 1: FIRE PUMP AND ACCESSORIES WORKS
All the pumps shall be factory assembled and factory tested. The main pumps and diesel engine driven pumps shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency cicumstances, coupled with 11 KW / 15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the Departmental Officers (Kirloskar make KDS 1555+ or Equivalent)
Supply and laying of 4 core 10 sq.mm. armoured copper cable for power wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthing, providing in wall with suitable size GI clamps, screws, wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers
Supply and laying of 2 core 1.5 sq.mm. armoured copper cable for control wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthing, providing in wall with suitable size GI clamps, screws, wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers.
Design, Supply, Erection, Testing and Commissioning of 50 x 6 mm GI flat run along the cable tray.
Design, Supply, Erection, Testing and Commissioning of 8 gauge bare copper wires for Gland earthing, loop earthing in the existing surface/recessed steel conduit, pump earths and other equipment body earthing as required.
Supply and Erection of suitable size electrical rubber mats tested to 433V, with grooved ISI Mark. The mat shall be provided to equal length the panels with a width of 1 meter. (IS 15625).
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height
Supply and Erection of following sizes GI Perforated type cable tray made out of 16G GI sheet folded to required shape with adequate number of supports. Rate shall be inclusive of suitable hanging support etc.
100mm x 50mm x 2.0mm
SECTION - 2: PIPES, FITTINGS & VALVES
The pipes shall be Mild Steel (MS) Heavy class conforming to relevant IS:1239 upto 150NB dia and IS:3589 for 200NB & above dia pipe. Factory rolled pipes between 200NB and 400NB diameter shall have min 6.0mm wall thickness. Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: HGURU / ISI MAKE / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: KIARTAR / OMEX / EQUIVALENT)
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
HYDRANT
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
PORTABLE FIRE EXTINGUISHERS WORKS
Supply and Erection of following types of extinguisher as per IS:2190 / IS:15683 guidelines with provision of wall bracket (fixed with anchor fastener) / MS powder coated floor stand / Trolley as per the specifications. All extinguishers should have the in-built pressure gauge. All extinguishers shall be free from CFC / HCFC. 0851 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
PORTABLE FIRE EXTINGUISHERS WORKS
Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent)
Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent)
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Mass Excavation by mechanical means and by manual means if required in all types of soil including dense soil, disintegrated / weathered / soft rock (except hard rock) including necessary manual excavation for dressing the edges & leveling, all leads and lifts. Rate to include disposing and stock the earth within the site wherever specified. The rate also include the cost of dewatering of both ground and surface water, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, struting, required for keeping the earth in position etc,. excavating loose pockets and compacting the same. Note: Permission to be obtained from the project manager for operate the item with premeasurement approval.
Providing and laying required thickness of plain cement concrete of PCC1:3:6 grade using 20mm and down size coarse graded hard stone aggregate for levelling course in foundation at any mass concrete and other similar works at all levels and heights, elevations, mechanical mixing, transporting and placing at all lifts, vibrating, compacting, levelling, curing, shuttering, dewatering wherever necessary, the cost of all materials, labour, leads and lifts, tools and plant, machineries etc., complete as per specifications.
Saucer Drain: Supply and fixing of Pre-cast concrete Saucer drain channels of 600 x 300 x 125 mm thick, smooth finish with 4mm wide, 2mm deep recessed ponted groove jointin cement morter 1:4, make: Super Paver or equivalent on cement concrete base of 1:2:4mix as per dwg, cost including all materials at site, all labour charges and other necessary charges to complete.
Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 x 305 x 15mm for Vision Impairment Person
Size of 300 x 300 mm , 35 mm thick, shot blasted/coated finish grey.
ELECTRICAL WORKS
LIGHTING DISTRIBUTION BOARD
8 Ways 7 Segment MCB DB - LPDB Supply, fixing, testing and commissioning of single/double door type compartmental 6way 7segment Three phase MCB DB in flush with wall and making good of the concealed portion with earth connection comprising of the following : Incomer: 1No. 63A FP MCB Sub Incomer : 3 Nos. 40A, 30mA, DP RCCB/ELCB Outgoing : 18 Nos. 6A to 32A SP MCB
6 Ways 7 Segment MCB DB - LPDB
Supply and fixing of 12 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 4 nos. 32A 3P MCB,24 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End
Supply, fixing, testing and commissioning of single/double door type 8 Way 7 segment three phase MCB DB in flush with wall and making good of the concealed portion with earth connection comprising of the following : Incomer: 1No. 63A FP MCB Sub Incomer : 3 nos. 40 A, 30mA,DP Outgoing : 24Nos. 6A to 32A SP MCB
8 Ways SPN MCB DB - MELDB
Supply, fixing, testing and commissioning of single/double door type 8 Way SPN MCB DB in flush with wall and making good of the concealed portion with earth connection comprising of the following : Incomer: 1No. 20A DP MCB Outgoing : 6 Nos. 6A DP MCB
8 Ways SPN MCB DB - ELDB-1 TO 3
Supply, fixing, testing and commissioning of single/double door type 8 Way SPN MCB DB in flush with wall and making good of the concealed portion with earth connection comprising of the following : Incomer: 1No. 20A DP MCB Outgoing : 6 Nos. 6A SP MCB
DOR- MAIN - DB
6 Way Three phase Vertical MCCB DB
Supply, fixing, testing and commissioning of single/double door type VTPN MCCB DB comprising of the following 6 way VTPN DB Incoming- 125A 4P MCCB - 1 No. Outgoing: 63A TP MCB - 6No`s 'C' curve
Supply and clamping of 3.5x70 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps As per Annexure I
Supply and run of 4 of 16 sq.mm.(101 / 0.45) PVC insulated SC unsheathed copper conductor of 1100V grade in 32mm Dia PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour
Supply and run of 4 of 16 sq.mm.(101 / 0.45) PVC insulated SC unsheathed copper conductor of 1100V grade in 32mm Dia PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and clamping of 3.5x300 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 3.5x120 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 3.5x95 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 3.5x70 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 3.5x50 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 3.5x25 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Supply and clamping of 2 x16 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supplying and laying of 25 x 6 mm GI Flat
Supplying and laying of 25 x 3 mm Cu. Flat
300 x 50mm height Ladder tray
Supply and fixing of 2 Module Modular type Steeped Electronic regulator in suitable modular GI box flushing in the wall with complete connected accessories.
Supply and fixing of 6A 3 pin modular switch and socket in suitable modular metal box GI box flushing in the wall with complete connected accessories.
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Supply and run of 2 of 2.5 sq.mm. (36 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with Modular Cover Plate and GI Metal Box with 6A Modular Switch with continuous earth wire connection 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) (5 Points per coil)
Supply and Installation of 15W LED Type Surface Mounted Downlight fitting for Similar to Make Havells Model No. - INTEGRANEOSURFACEDLS15WLED840S
Supply and Installation of 40W LED Type Surface Mounted Industrial Light fitting for Similar to Make Havells Model No. - MAGNUMGRANDNEOIP6640WLED857SPC
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
Supply, installation, testing and commissioning of 2kVA UPS system Minimum 2 Hours Battery backup with single phase input and single phase output with necessary accessories and tools as required as per site condition.
Supply, installation, testing and commissioning of 3kVA UPS system Minimum 2 Hours Battery backup with single phase input and single phase output with necessary accessories and tools as required as per site condition.
Supply, installation, testing and commissioning of 5kVA UPS system Minimum 2 Hours Battery backup with single phase input and single phase output with necessary accessories and tools as required as per site condition.
Supply & Installation of 25mm Dia. Rigid PVC Conduit pipe for point wiring
Supply & Installation of 50mm/38mm Dia. HDPE pipe for wiring
Supply & Installation of shock treatment chart in English and Local language. Shock treatment chart to be printed & framed with glass front size 300 x 600.
Supply & Installation of first aid box with first aid medicines
Supply & Installation of first aid kit with wall mounting iron stand.
Supplying 415V Gloves in wooden box sprayed with dry chalk powder ISI branded.
Supply & fixing of '4 hour fire rated fire retardant material sealing all electrical cutouts/ducts and openings made in the slab / wall / partition to take conduits / cable trays / raceways etc as required complete / as directed by the site incharge.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with GI Flush mounting box ,plastic combined cover plate and 6A One way modular type (one module) switch with light / fan marking and making good of the concealed portion with suitable color for PVC light point (All switches ,cover plate and GI mounting box should be higher end company make (For light points) (Data-1)
Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with 1 modular plastic box with cover plate and 6A modular switch (two way) with painting of suitable colour for open PVC staircase light point (Data-2)
Supply and fixing of single box type 4'20W LED fitting with TW round blocks on wall or ceiling with with PVC unsheathed copper leads from terminals to the fitting (LED fittings should be of Higherend company make like philips / cromption etc) (Data -3)
Supply and fixing of 4'20W LED fitting complete with 1.5 mt conduit pipe suspension from the ceiling PVC unsheathed copper leads from terminals to the fitting (Data-4)
Supply and fixing of 4'20W LED fitting complete with 2 mt conduit pipe suspension from the ceiling PVC unsheathed copper leads from terminals to the fitting (Data-5)
Supply and fixing of chandlier fitting with LED bulb with connection (MR)
Supply and fixing of 2ft x 2 ft (600mm x 600mm) square type LED light fitting with chain link connection (Philips make) (Data-7)
Supply and fixing of fancy lamp fittings with 9W LED bulb on wall with connections (Data - 8)
Supply and fixing of 18W LED square type recessed fitting on ceiling with PVC unsheathed copper leads from terminal to fitting (Data-2)
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete without provision of holes in the wall
Supply and fixing of louvers shutters arrangements for 375mm (15") sweep light duty AC Exhaust fan
Supply and fixing of 9W WT bulk head fitting on wall or ceiling with PVC unsheathed copper leads from terminal to fitting (Data-3)
Supply and clamping of 2 x 10 sqmm PVC LTUG armoured cable on wall with MS clamps SD 216
Supply and Fixing of 9W LED bulb for BH Point (Data 3)
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate(plastic) on suitable module concealed Box (GI ) in flush with wall with connections Higher End (SD-476)
Supply and fixing of Entry/Exit light board with connection (Data-9)
Supply and fixing of 48W LED street light fitting with pressure diecase Aluminium housing with IP 65 Protection with 25 mm dia G.I. pipe and bend class-B complete on wall with PVC unsheathed copper leads MS clamps and Aluminium painting LED fittings should be Higher end /philips make(Data-10)
Supply and fixing of 48" AC Ceiling fan complete with stepped electronic 300w regulator with 1mt downrod and existing clamp (SD-107)
Supply and fixing of 750mm (30") sweep 30" sweep AC wall mounting air circulator with suitable clamp and connection (Data-11)
Supply and fixing of 450mm (18") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall (SD-118)
Supply and fixing of louvers shutters arrangements for 450mm (18") sweep exhaust fan (SD-123)
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall (SD-114)
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fanl (SD-120)
Supply and fixing of 1no 6A plug mounted in suitable 1 module Metal surface mounted box with suitable plastic combined cover plate with Connections (Data-14)
Supply and fixing of 1no 6A switch mounted in suitable 1 module Metal surface mounted box with suitable plastic combined cover plate with Connections (Data-15)
Supply and fixing of 1no 16A plug mounted in suitable 1 module Metal surface mounted box with suitable plastic combined cover plate with Connections (Data-16)
Supply and fixing of 1no 16A switch mounted in suitable 1 module Metal surface mounted box with suitable plastic combined cover plate with Connections (Data-17)
Supply and fixing of 6 module flush mounting box with combined cover plate plastic fixed with 1no 6A 1 way switch and 1no 6A Universal Plug with connections (Data-18)
Supply and fixing of 6 module flush mounting box with combined cover plate plastic fixed with 1no 16A 1 way switch and 1no 16A Universal Plug with connections (Data-19)
Supply and fixing of 20A DP MCB Switch in suitable 2 pole sheet steel enclosure with earth connection (Data-7)
Supply and fixing of 40A DP MCB Switch in suitable 2 pole sheet steel enclosure with earth connection (Data-8)
Supply and fixing of 32A TP MCB Switch in suitable 4 pole sheet steel enclosure with earth connection (Data-9)
Supply and fixing of 63A 8 way horizontal type 3 phase MCB DB with metal door cover with IP42 protection with 1 no 63A FP MCB switch as incoming and 7 nos 32A TP MCB switch and 3 nos 6A to 32A SP MCB switches as outgoing in flush with wall and making good of the concealed Portion with earth connection only(Data-10)
Supply and fixing of 8 way vertical type triple pole and neutral MCB Sheet steel enclosure distribution board with double door (metal) with 1no 63A four pole MCB switch as incoming and 4 nos 32A TPMCB, 12 nos 6A-32A SP MCB as outgoing in flush with wall with earth Connection only (Data-8)
Supply and fixing of 8 way vertical type triple pole and neutral MCB Sheet steel enclosure distribution board with double door (metal) with 1no 100A four pole MCB switch as incoming and 3 nos 63A TPMCB, 15 nos 6A-32A SP MCB as outgoing in flush with wall with earth Connection only (Data-9)
Supply and fixing of 63A MCB Switch in suitable 4 pole sheet steel enclosure in flush with wall with earth connection (Data-17)
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board of double door type with metal door with IP-43 protection with 1no 32A DP MCB as incoming and 10 nos 6A to 32A SP MCB outgoing flush with wall and making good of the concealed portion with earth connection only(The MCB DB and MCB's should be Legrand or Higher end make)(Data-25)
Supply and fixing of horizontal 3 phase MCB DB with Acrylic Door cover with IP42 protection with 1 no 63A TP MCB switch as incoming and 4 nos 40A DP MCB switch and 16 nos 6A to 32A SP MCB switches as outgoing in flush with wall and making good of the concealed Portion with earth connection only(Data-11)
Supply and fixing of vertical 3 phase 4 way MCB DB with Acrylic Door cover with IP42 protection with 1 no 100A FP MCCB switch as incoming and 4 nos 63A TP MCB switch as outgoing in flush with wall and making good of the concealed Portion with earth connection only(Data-12)
Supply and run of 2 of 2.5 sqmm (36/0.3) PVC insulated single core unsheathed Copper conductor of 1100V grade in Suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire and making good of the concealed portion with suitable colour (Data-19)
Supply and run of 2 of 4 sq.mm (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire and making good of the concealed portion with suitable colour (Data-20)
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 2.5 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(Data-30)
Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(sd 441)
Supply and run of 4 of 10 sqmm (101/0.45) PVC insulated Single Core unsheathed Copper Conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(SD 446)
Supply and clamping of 3-1/2 x 95 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (SD-226)
Supply and laying of 3-1/2 x 95 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-208)
Supply and run of 1 of No.8 SWG copper conductor on suitable PVC rigid pipe on wall with painting of suitable colour for earth connection (Data -33)
Supply and fixing of foot lamp on wall with connections(Data-6)
Supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch(SD-105)
Supply and fixing of LED mirror lamp fitting with bulb (Data-7)
Supply and fixing of 10W WT bulk road fitting (Data-8)
Supply and fixing of surface mounted 5W LED fitting on wall or ceiling with connections(Data-9)
Supply and fixing of 1500W automatic electric water heater of 35 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire,but without plumbing work (SD-103)
Supply and fixing of 20A DP MCB Switch in suitable 2 pole sheet steel enclosure in flush with wall with earth connection (Data-12)
Supply and fixing of 1 module G.I flush mounting box concealed in wall with 1no 1 way 16A modular switch with combined cover plate(plastic) with Connections (Data-13)
Supply and fixing of 2 module G.I flush mounting box concealed in wall with 1no 6A/16A modular socket (plug) with combined cover plate(plastic) with Connections (Data-14)
Supply and fixing of 6 module G.I flush mounting box concealed in wall with 2nos 6A modular switch and 2nos 6A universal socket with combined cover plate(plastic) with Connections (Data-15)
Supply and fixing of 1no 20A DP 1way switch with indicator in suitable 2 module Metal flush mounted box with suitable plastic combined cover plate with Connections (Data-16)
Supply and fixing of 12 way triple pole and neutral MCB sheet steel enclosure horizontal distribution board of double door type with metal door with IP42 protection concealed in wall with 1 No 32A FP MCB as incoming and 36 Nos 6A to 32A SPMCB outgoing on wall with earth connection (The MCB DB and MCB's should be Legrand make) (Data-17)
Supply and fixing of 4 way triple pole and neutral MCB sheet steel enclosure horizontal distribution board of double door type with IP42 protection with 1 No 32A TP MCB as incoming and 12 Nos 6A to 32A SPMCB as outgoing in flush wall with earth connection (The MCB DB and MCB's should be Legrand make) (Data-18)
Supply and fixing of 4 way triple pole and neutral MCB sheet steel enclosure vertical distribution board of double door type with IP42 protection with 1 No 63A FP MCB as incoming and 4 Nos 32A TPMCB as outgoing in flush wall with earth connection (The MCB DB and MCB's should be Legrand make) (Data-19)
Supply and fixing of 4 way triple pole and neutral MCB sheet steel enclosure vertical distribution board of double door type with metal door with IP42 protection with 1 No 63A FP MCB as incoming and 2 Nos 32A TPMCB, 6 Nos 6A to 32A SPMCB as outgoing in flush wall with earth connection (The MCB DB and MCB's should be Legrand make) (Data-20)
Supply and run of 4 of 10 sqmm (140/0.3) PVC insulated Single Core unsheathed Copper Conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(Data-24)
Supply and run of 4 of 16 sqmm (101/0.45) PVC insulated Single Core unsheathed Copper Conductor of 1100V grade in suitable PVC rigid pipe concealed on wall and ceiling with continuous earth wire connection of 1 of 1.5 sq.mm (22/0.3) PVC copper wire with painting of suitable colour(Data-25)
Supply and clamping of 4x25 sq.mm. PVC/XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps As per Annexure I
Supply and fixing of brass cable gland with termination for 4CX25sq.mm. PVC armoured LTUG cable with earth connection As per Annexure I
Supply and fixing of brass cable gland with termination for 3.5CX70sq.mm. PVC armoured LTUG cable with earth connection As per Annexure I
Supply and fixing of 32A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection
Supply and clamping of 3-1/2 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (SD-229)
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection (SD-193)
Supply and fixing of brass cable gland with termination for 3.5CX16sq.mm. PVC armoured LTUG cable with earth connection As per Annexure I
Supply and fixing of brass cable gland with termination for 3.5CX300sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland with termination for 3.5CX120sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland with termination for 3.5CX95sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland with termination for 3.5CX70sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland with termination for 3.5CX50sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland with termination for 4X16sq.mm. PVC armoured LTUG cable with earth connection
Supply and fixing of 6/16A modular switch and socket in suitable modular metal box GI box flushing in the wall with complete connected accessories.
Supply and fixing of 6A 3 pin modular switch in suitable modular metal box GI box flushing in the wall with complete connected accessories.
Supply and fixing of 6A 3 pin modular switch and socket in suitable modular metal box GI box flushing in the wall with complete connected accessories.
Supply and run of 3 of 4 sq.mm. (54 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with Modular cover plate with GI Metal Box and 5A Modular Switch and making good of the concealed portion with suitable colour with with continuous earth wire connection 14 SWG TC wire for for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.)
Supply and Installation of 10W LED Type Surface Mounted Downlight fitting for Similar to Make Havells Model No. - INTEGRANEOSURFACEDLS10WLED840S
Supply and fixing of side holder
Supply and fixing of 10W WT bulk head lights
supply and fixing of 1400mm (56") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 600mm down rod on the exisitng fan clamp
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. . SSB CFL PANELIncomer: 1No. 400A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS)(96 x 96mm size) 1set - 400A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 400A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 8Nos. 63A 4P MCCB 25kA 8 set-ON,OFF,TRIP 8 set - Control MCB with Neutral link.
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. . SSB CBL PANEL Incomer: 1No. 400A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS)(96 x 96mm size) 1set - 400A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 400A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 2Nos. 125A TPN MCCB 25kA 12Nos. 63A TPN MCCB 25kA 2Nos. 32A TPN MCCB 25kA 18 set-ON,OFF,TRIP 18 set - Control MCB with Neutral link.
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. . SSB CBL PANEL Incomer: 1No. 125A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS)(96 x 96mm size) 1set - 125A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 125A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 1No. 100A TPN MCCB 25kA 6Nos. 63A TPN MCCB 25kA 7 set-ON,OFF,TRIP 7 set - Control MCB with Neutral link.
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. . SSB DB PANEL (Dormitory 1 & 2) Incomer: 1No. 400A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS) (96 x 96mm size) 1set - 400A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 400A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 1No. 200A TPN MCCB 25kA 1No. 160A TPN MCCB 25kA 1No. 125A TPN MCCB 25kA 7Nos. 63A TPN MCCB 25kA 1No. 32A TPN MCCB 25kA 11 set-ON,OFF,TRIP 11 set - Control MCB with Neutral link.
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. . UG SUMP PANEL (PHASE - 2) Incomer: 1No. 200A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS)(96 x 96mm size) 1set - 200A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 200A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 1No. 125A TPN MCCB 25kA 1No. 100A TPN MCCB 25kA 1Nos. 63A TPN MCCB 25kA 1No. 32A TPN MCCB 25kA 4 set-ON,OFF,TRIP 4 set - Control MCB with Neutral link.
Design, Supply, testing and commissioning of cubicle type floor mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. SSB - KM PANEL Incomer: 1No. 400A,4P MCCB 36kA with all connected accessories. Metering for Incomer: 1 No. Multifunction meter (KWH+KW+A+V+F+MD with RS - 485 port, MODBUS)(96 x 96mm size) 1set - 400A ,5VA, CL 0.5, CT's for metering. 1 set - RYB LED type indicating lamps. 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP Bus bar:1 set - 400A, 4Wire, 36KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC Busbar supports. Outgoings: 1No. 100A TPN MCCB 25kA 4Nos. 63A TPN MCCB 25kA 3No. 32A TPN MCCB 25kA 8 set-ON,OFF,TRIP 8 set - Control MCB with Neutral link.
Supply, Erection, Testing, Commissioning and Handing over of 1 no 10 persons capacity passenger lift as per following technical specifications including all taxes and duties. ( WITH MACHINE ROOM) Technical Specifications: 1. Location : Cottage 1 and 2 in Arulmigu Subramaniyasamy Temple at Thiruchendur in Thoothukudi District 2. No of Lift : One No 3. Type of Lift : Passenger lift 4. Capacity of Lift : 10 Persons Passenger(680Kgs) 5. Speed : 1.00 mtr/Sec 6. Type of Drive : Microprocessor based specific variable voltage variable frequency V3F Drive with enhanced ride comfort and near zero leveling functions 7. No of floor : Ground +2 floors 8. Total Travel: 10 Mtrs approximate 9. Leveling Accuracy : High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel Hairline finish No.4 hair line finish & panels with direct lighting and new beautiful single tile false ceiling with tubular handrail and mirror. 11. Position of Machine: Directly above the lift well. 12. No of Landing Entrance: One in front 4 Nos only. 13. No of Car Entrance: One in front only. 14. Car Entrance Door: Centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel. 15. Landing Entrance Door: Center opening automatic power door with stainless steel No. 4 hair Line finish with view panel. 16. Lift well: 2000mm (width) x 2700mm (depth) available size.
17. Lift pit depth available: 1600mm 18. Car size: 1100mm wide x 1600mm deep x 2300mm height (Part 1-2000). 19. Car clear opening: 800 mm x 1600 mm (as per IS 14665 (Part-1)-2000). 20. Lift machine room: As per standard specification. 21. Power supply: 415V, 3 phase, 50 cy /sec A.C supply for power and 230V, 50 Hz single phase AC supply for light. 22. Control: Micro processor computer based - simplex collective full collective logic system with / without attendant mode. 23. Car fittings 4 Nos 8W LED recess mount fixture lighting with cross flow fan 24. Lift Well: RCC construction with brick masonry. 25. Indication: Up/Down Digital Direction scroll type and position indicator for all landing and in car. 26. Emergency Alarm Bell: Batteryoperated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift contractor. 31. Stainless Steel sill angles and facia Plates: To be provided by lift contractor. 32. Steel for lift Machinery: To be provided by lift contractor. 33. Servicing and Maintenance: Free Comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Provision of 1+3 EPABX intercom with phone to be provided at the following places,vide i.Lift
switch, main suspension ropes, counter weights, lifting joint joist for mounting the machineries. 40. Guarantee: Guarantee for the materials & workmanship of equipments complete should be offered by the Lift firm for a period of not less than one year. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over.
Supply, Erection, Testing, Commissioning and Handing over of 1 no 13 persons capacity passenger lift gearless type without machine room as per following technical specifications including all taxes and duties.( WITH MACHINE ROOM ) Technical Specifications: 1. Location : Cottage 1 and 2 in Arulmigu Subramaniyasamy Temple at Thiruchendur in Thoothukudi District 2. No of Lift : One No 3. Type of Lift : Passenger lift 4. Capacity of Lift : 13 Persons Passenger(1105Kgs) 5. Speed : 1.00 mtr/Sec 6. Type of Drive : Microprocessor based specific variable voltage variable frequency V3F Drive with enhanced ride comfort and near zero leveling functions 7. No of floor : Ground +1 floors 8. Total Travel: 10 Mtrs approximate 9. Leveling Accuracy : High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel Hairline finish No.4 hair line finish & panels with direct lighting and new beautiful single tile false ceiling with tubular handrail and mirror. 11. Position of Machine: Directly above the lift well. 12. No of Landing Entrance: One in front 4 Nos only. 13. No of Car Entrance: One in front only. 14. Car Entrance Door: Centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel. 15. Landing Entrance Door: Center opening automatic power door with stainless steel No. 4 hair Line finish with view panel. 16. Lift well: 2100mm (width) x 2000mm (depth) available size.
17. Lift pit depth available: 2700mm 18. Car size: 2000mm wide x 1100mm deep x 2300mm height (Part 1-2000). 19. Car clear opening: 800 mm x 1600 mm (as per IS 14665 (Part-1)-2000). 20. Lift machine room: As per standard specification. 21. Power supply: 415V, 3 phase, 50 cy /sec A.C supply for power and 230V, 50 Hz single phase AC supply for light. 22. Control: Micro processor computer based - simplex collective full collective logic system with / without attendant mode. 23. Car fittings 4 Nos 8W LED recess mount fixture lighting with cross flow fan 24. Lift Well: RCC construction with brick masonry. 25. Indication: Up/Down Digital Direction scroll type and position indicator for all landing and in car. 26. Emergency Alarm Bell: Battery operated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift contractor. 31. Stainless Steel sill angles and facia Plates: To be provided by lift contractor. 32. Steel for lift Machinery: To be provided by lift contractor. 33. Servicing and Maintenance: Free Comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Provision of 1+3 EPABX intercom with phone to be provided at the following places,vide i.Lift
Head Room, ii. Reception Room and iii. Inside the Lift, by lift contractor. 35. Lift License: Preparation of drawing, Payment of charges to CEIG and Insurance policies if any and obtaining CEIG safety certificate and lift license as per lift act should be done by lift contractor. 36. Automatic rescue device - To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charges inverter under voltage protection system etc. 37. Floor annunciation system with music. 38. Special futures: (a). Infra red door sensor withFull height screen. (b). Full width half height rear panel Mirror. (c).Voltage stabilizer for circuit control. (d). Tubular Stainless Steel hand rail three sides in car. (e). Signal Fixtures (f). Vandal proof S.S. button with S.S. (g). Stainless steel door frames (h). V3F door operator (i) Call register signal (j) Pit ladder (k). Braille buttons (l).Stainless steel facia for car operating panel and landing fixtures. (m). ON-OFF switch for fan and light. (n) Over load warning indicator. (0) Fire rating: 60 Mins. 39. Over speed governor, phase failure and phase reversal relay, alarm bell, Guide brackets for car and counter weight, rubber padding under winding unit, Motor of adequate capacity, single reduction worm gear, electromagnetic brake with compression springs, car safety gears, buffer, electro mechanical door locks, emergency key, side supporting angles, motor over load protection devices, final limit
switch, main suspension ropes, counter weights, lifting joint joist for mounting the machineries. 40. Guarantee: Guarantee for the materials & workmanship of equipments complete should be offered by the Lift firm for a period of not less than one year. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over (Data-34)
Supply and fixing of 100A four pole MCB switch as incoming in suitable power coated 16 SWG CRCA cubical panel with the outgoing switches of 6nos 63A four pole MCB switches with suitable copper bus for 3 phase and neutral with earth connection and phase indicator lights (Data-25)
Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good (SD-750)
Supply and laying of 3-1/2 x 70 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-432)
Supply and clamping of 3 1/2 x 95 sq.mm PVC aluminium LTUG armoured cable through HDPE pipe on post or on wall with MS clamps (Date-26)
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection (SD 190)
Supply and fixing of 100A TPN sheet double break switch with HRC fuse and neutral on suitable angle iron framework with MS cable entry boxes and with PWD earthing (SD 168)
Supply and fixing of erection and commisioning 400 amps dust vermin proof floor mounting cuical type metering panel board size 20 ft x 7.5 ft x 1.5 ft made of 16 Swg CRCA sheet steel for outer body and suitable angle frame work 2" x2" x 1/4" with copper as of size 25 mm x 6 mm for three faces and neutral on synthetic molded compound support with hylem sheet seperation following MCP swithes and fuse unit INCOMING : 400 A TPN switch disconnected fuse unit HRC fuses double break 1 no 500 Amps porcelien fuse units 3 units 3 nos OUT GOING: 32 A DP MCP Swicth 41 nos 32 A porceliln 41 nos 32 A FP MCB switch -1 no
Supply and fixing of erection and commisioning 315 amps dust vermin proof floor mounting cuical type metering panel board size 9 ft x 6 ft x 1.5 ft made of 16 Swg CRCA sheet steel for outer body and suitable angle frame work 2" x2" x 1/4" with copper as of size 25 mm x 6 mm for three faces and neutral on synthetic molded compound support with hylem sheet seperation following MCP swithes and fuse unit nd 300A fuse unit 3 phaseTNEB Meter inside the cubical panel INCOMING : 315 A TPN switch disconnected fuse unit HRC fuses double break 1 no OUT GOING: 63 A DP MCP Swicth disconnector fuse unit interior oly with HRC fuse double break 12 nos
Supply and fixing of erection and commisioning 315 amps dust vermin proof floor mounting cuical type metering panel board size 9 ft x 6 ft x 1.5 ft made of 16 Swg CRCA sheet steel for outer body and suitable angle frame work 2" x2" x 1/4" with copper as of size 25 mm x 6 mm for three faces and neutral on synthetic molded compound support with hylem sheet seperation following MCP swithes and 300A fuse unit 3 phaseTNEB Meter inside the cubical panel INCOMING : 315 A TPN switch disconnected fuse unit HRC fuses double break 1 no OUT GOING: 1.100 A DP MCP Swicth-1 no 2.40 A DP MCB switch 24 nos
Supply and fixing of erection and commisioning 315 amps dust vermin proof floor mounting cuical type metering panel board size 9 ft x 6 ft x 1.5 ft made of 16 Swg CRCA sheet steel for outer body and suitable angle frame work 2" x2" x 1/4" with copper as of size 25 mm x 6 mm for three faces and neutral on synthetic molded compound support with hylem sheet seperation following MCP swithes and 300A fuse unit 3 phaseTNEB Meter inside the cubical panel INCOMING : 315 A TPN switch disconnected fuse unit HRC fuses double break 1 no OUT GOING: 1.100 A DP MCP Swicth-1 no 2.40 A DP MCB switch 33 nos
Supply and fixing of 12 mtrs minimast with 6 nos 150 W LED fittings complete with all accessories control panel and gear box arrangements
Supply and laying of 2 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good
Supply and laying of 2 x 16 sq.mm PVC armoured LTUG cable in a post and walls with MS Clamps
Supply and fixing brass Cable gland of 2 x 16 sq.mm PVC armoured LTUG cable with earth connection
Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC LTUG armoured cable with earth connection
Supply and fixing brass Cable gland of 4 x 16 sq.mm PVC armoured LTUG cable with earth connection
Supply and laying of 4 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good
Supply and laying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good
Supply and laying except 3-1/2 x 240 sq.mm. PVC LTUG armoured cable post or on wall with MS clamps SD -230
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. PVC armoured LTUG cable with earth connection SD -194
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection SD 76
Supply and fixing of 4nos.6A two module 5 pin socket , 4 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB Isolator as incoming and 24 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and Run of 2 of 1.5 sq.mm. (22/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling and making good of the concealed portion with suitable colour
Supply and Laying of 3-1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good (SD-754)
Supplying and clamping of 3-1/2 x 240 Sqmm PVC LTUG armoured cable through HDPE Pipe an post or on wall with MS clamps (Data - 17)
Supply and Run of 4 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour (SD-428)
Supply and erection of 1.5 Ton 5 star rated Split type airconditioners (4800 cal)/hr GI sheet (ABS ,HIPS plastic fitted with hermerically ,scales compressors operating refrignt R-22 / non CFC suitable for( floor mounting and ceiling mounting ) confirming to IS 1391 ( part 2 ) 92 ( AMDT .1)suitable operation on 230 V,50 HZ single phase AC supply .a.mounting / filtering indoor & outdoor units at their respective location b.Laying Refrigrnt ppe line of reequired lengh connecting both units after drilling holes in the wall thickness copper tube shall be not less than 0.7mmc.insulating the suction pipe with expanded polyurithene foam 5 mm tubeing d .laying 15 mm dia flexvle pvc drain pipe to throw out the condensate water being formed in the indoor e.Leak testing the entire system unit f. Charging refrigent gas the unit g. Suitable electric wiring & swith should be provided with in the 3 meters of the location of uniit Carrier or equivant make
Supply and installation of 4 KVA capacity automatic voltage Stabilizer with time delay relay
Supply and laying of 5/8" and 3/8" copper pipe ( extra beyond 3 m supply with AC unit)
Supply and fixing of MS stand for fixing outdoor unit
Supply and fixing of Drain pipe arrangements for all the AC units with 3/4" PVC pipe with proper connection
GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column "BB" for all works in this package} (Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
ABIRAMI ENGINEERING CONSTRUCTION AND CO
GRM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid