| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹11.9 L (7.61%)Admitted-Finance | ₹1.7 Cr+₹11.9 L (7.61%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹18.1 L (11.5%)Admitted-Finance 3 238 VENKATESA LAYOUT S V MILLS POST UDUMALPET 642 128 | UDUMALPET | TIRUPPUR | TAMIL NADU | 642128 | ₹1.8 Cr+₹18.1 L (11.5%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical BQR conditions B, C and E not satisfied |
| 5 | Rejected-Technical | - | - | Rejected-Technical BQR conditions B, C and D not satisfied |
| Sl No | Description | Qty | Unit | ROBERT WILSON L1 | C ILANGAMANI L2 | vasanthaconstructions L3 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation in hard stiff clay, stiff black cotton hard red earth, shales, muram, gravel, stoney earth and earth mixed with small size boulders with an initial lead, lift, etc, complete | 600 | Cum | - | - | - |
| 2.00 | Earthwork excavation in SDR not requiring blasting with an initial lead of 10m and lift of 2m etc complete | 150 | Cum | - | - | - |
| 3.00 | Earthwork excavation in MR and DMR not requiring blasting.with an initial lead of 10m and lift of 2m etc complete | 150 | Cum | - | - | - |
| 4.00 | Removing hard rock by wedging, chesselling and trimming to proper shape where blasting is prohibited. | 40 | Cum | - | - | - |
| 5.00 | PCC 1:3:6 mix using 40mm HBS machine crushed metal for foundation without form work including cost of all labour, materials, lead, lift, curing etc., complete | 940 | Cum | - | - | - |
| 6.00 | PCC 1:3:6 mix using 40mm HBS machine crushed metal for foundation with form work including cost of all labour, materials, lead, lift, curing etc., complete | 390 | Cum | - | - | - |
| 7.00 | Plastering with CM 1:3 mix, 12mm thick for plinth including cost of all materials, labour, lead, lift, watering, curing etc., complete | 805 | sq m | - | - | - |
| 8.00 | Colour washing two coats with approved quality of colour pigments over one coat of white cement including cost of all materials, labour, lead & lift etc., complete. Structure Plinths | 805 | sq m | - | - | - |
| 9.00STEELS: Supply of Iron & Steel as per latest IS 2062 wherever required as directed by the field engineer . | ||||||
| 9.01 | RSJoist 200 X 100mm | 21.2 | MT | - | - | - |
Tender Value
₹1.8 Cr
EMD Value
₹1.8 L
Closing Date
20 May 2020, 2:00 pmClosed
CE/TP-II/Trichy
Chief Engineer, Transmission Projects-II, TANTRANSCO, Mannarpuram, Trichy-20
Providing foundation concrete for various structural and equipment plinths, supply and erection of tower and of steel for 230KV and 110KV structures, Erection of Strung bus, etc., for the establishment of Nanguneri 230/110KV AI Substation
2020_EB_162030_1
CE/Tp-II/TRY/E-20/19-20
Open Tender
Electrical Works
Works
150 days
Nanguneri
As per tender specification
4 documents required · 4 mandatory
₹0
₹1.8 L
Yes
1 Oct 2020
31 Mar 2020
21 May 2020
31 Mar 2020
20 May 2020
31 Mar 2020
Amount
Earth work excavation for foundation in hard stiff clay, stiff black cotton hard red earth, shales, muram, gravel, stoney earth and earth mixed with small size boulders with an initial lead, lift, etc, complete
Earthwork excavation in SDR not requiring blasting with an initial lead of 10m and lift of 2m etc complete
Earthwork excavation in MR and DMR not requiring blasting.with an initial lead of 10m and lift of 2m etc complete
Removing hard rock by wedging, chesselling and trimming to proper shape where blasting is prohibited.
PCC 1:3:6 mix using 40mm HBS machine crushed metal for foundation without form work including cost of all labour, materials, lead, lift, curing etc., complete
PCC 1:3:6 mix using 40mm HBS machine crushed metal for foundation with form work including cost of all labour, materials, lead, lift, curing etc., complete
Plastering with CM 1:3 mix, 12mm thick for plinth including cost of all materials, labour, lead, lift, watering, curing etc., complete
Colour washing two coats with approved quality of colour pigments over one coat of white cement including cost of all materials, labour, lead & lift etc., complete. Structure Plinths
STEELS: Supply of Iron & Steel as per latest IS 2062 wherever required as directed by the field engineer .
RSJoist 200 X 100mm
MS Angle 100X100X8mm
MS Angle 65X65X6mm
MS Angle 50X50X6mm
MS Channel 125X65mm
MS Channel 100X50mm
Supply of Reflector sticker of reputed make for colour coding of all equipments and structures as per field requirement and as directed by the field engineer.
Supply and provision of M8, M10, M12 and M16 (full / Half thread) G.I bolt and nuts of various sizes including plate/spring washers as required and as directed by the field engineer
POWER CONNECTORS: Supply of Aluminium Power Connectors/Clamps/Fittings with SS Bolts and Nuts, frieght ,including modification if any etc., confirming to IS as per the drawing and specification
6 Bolt Tension fitting
Switch End Clamp for Zebra
Switch End Clamp for 75mm Bus
Switch End Clamp for Panther
Switch End Clamp for Mink
T Clamp for 75mm Bus to Zebra
T.Clamp for Zebra to Zebra
T.Clamp for Panther
Free End clamp for 75mm Bus
3" bus bar jointing Clamp
3" busbar expansion clamp
PG clamp for Zebra
PG clamp for Panther
Corona Bell 75 mm
Spacer Clamp (225mm spacing)
Labour, machinery, Consumables for the Fabrication for steel structures
Heavy section (14 kg/m and above)
Light section (below 14 kg/m)
Labour for the Erection of the Fabricated Steel Structures
Heavy section (14 kg/m and above)
Light section (below 14 kg/m)
Supply and fabrication and erection of eye bolts/grout bolt with 20/22 mm rod confirming to IS with proper threading and 2 nos MS Nuts as directed by the field Engineer
Grout Bolt
Eye Bolt
Labour for the Erection of Strung bus and all related hardwares, fittings, clamps including Meggering, hoisting of insulators, and consumables and as directed by the field engineer
230 KV Double Conductor Strung Bus/phase
110 KV Double Conductor Strung Bus/phase
Labour for the erection of Insulator single pole stack for supports Uprights/Underhang including Meggering & other consumables and as directed by the field engineer
Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field engineer
75 mm (1 length)
75 mm with bend (1 length)
Labour for the Erection of Jumper/Droppers using Moose/Zebra/panther Double Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field engineer
Supply and labour charges for providing GI chain link fencing wire of size 50-60 square of 10 swg
PAINTING: Supply of paint of reputed make and Labour,consumables for first primer coat using red oxide Paint and first finish coat of Painting using Aluminium Paint including consumables, after proper surface preparation using appropriate machinery to remove rust/scales etc as directed by the field engineer
Supply of paint of reputed make (ie Asian, Dulux, Nerolec paint) and Labour for Second coat of Painting using Aluminium paint including consumables
Supply & Labour charges for two coats of enamel painting in any substation structures, steels, etc and wherever required including the cost of reputed make paints and other consumables as directed by the field engineer
SGST & CGST (If applicable quote the value, if not enter '0')
IGST (If applicable quote the value, if not enter '0')
C ILANGAMANI
vasanthaconstructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
BOQ_193851.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .