Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr Quoted ₹1.9 Cr | L1 | Accepted-AOC Lowest Bid L1 rank is competitive and reasonable during Scrutiny amongst bidders |
| 2 | L2₹1.9 Cr+₹5.6 L (3.03%)Rejected-AOC 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | ₹1.9 Cr+₹5.6 L (3.03%) | L2 | Rejected-AOC Being not lowest |
| 3 | L3₹2.0 Cr+₹16.9 L (9.05%)Rejected-AOC | ₹2.0 Cr+₹16.9 L (9.05%) | L3 | Rejected-AOC Being not lowest |
| 4 | L4₹2.1 Cr+₹21.4 L (11.5%)Rejected-AOC 0 00 NEAR KRISHNA PETROL PUMP GEEDAM ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | ₹2.1 Cr+₹21.4 L (11.5%) | L4 | Rejected-AOC Being not lowest |
| 5 | L5₹2.1 Cr+₹21.6 L (11.6%)Rejected-AOC | ₹2.1 Cr+₹21.6 L (11.6%) | L5 | Rejected-AOC Being not lowest |
Tender Value
₹3.0 Cr
EMD Value
₹3.7 L
Closing Date
11 May 2024, 6:00 pmClosed
CWE
CWE AF BAMRAULI
SPECIAL REPAIR OF MAIN BUILDING OF KENDRIYA VIDYALAYA AT AF STATION BAMRAULI
2024_MES_649888_1
87361/E8
Open Tender
Civil Works
Item Rate
273 days
BAMRAULI PRAYAGRAJ
Class B Category a i and other criteria as per Tender Doc and NIT
8 documents required · 8 mandatory
₹2,000
GE(AF) BAMRAULI
₹3.7 L
Yes
1 Jun 2024
11 Apr 2024
13 May 2024
11 Apr 2024
11 May 2024
4 May 2024
11 Apr 2024 - 18 Apr 2024
Amount
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking up or down steel tubing pipe with fittings connections 15mm bore complete all as specified and directed.
Taking up or down steel tubing pipe with fittings connections 20mm bore complete all as specified and directed.
Demolition and breaking up 100mm dia salt glazed stone ware/ RCC drain pipes jointed in cement mortar and taking out of trenches removing the debries from site complete all as specified and directed.
Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc,cement concrete of any description & in any position not otherwise specifically provided for.
Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
Demolition of PCC in ground floor n.exc 15cm thickness below or above ground level complete all as specified and directed.
Demolition to reinforced cement concrete of roofs, floors ( other than ground floors )beams staircases,landing,chajjas and similar suspended work complete all as specified and directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated , etc) sheets n roof coverings. complete all as specified.
Dismantling of cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trences if required complete all as specified and directed.
S & F steel windows or ventilators, fixed type, with glazing bars as per ref drg complete all as specified and directed. Note: Ref drg No. CE/ALD/TD-172
S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including supply & fixing lugs,125 mm size MS hinges, lock strike plate complete all as specified and directed.
S & F 35mm thick flush shutter , solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F factory made single etrudded WPC (wood polymer composite) solid door/ window frames/ chowkhat of size 45 X 70mm comprising of virgin PVC resin of 'K' value 58-60 (suspension grade) calcium carbonate and natural fibre (wood powders/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density 750Kg/cum and screw withdrawal strength of 2200N (face) & 1100N (edge), minimum compressive strength 58 N/Sqmm, modulus of elasticity 900N/ sqmm and resistance to spread of flame of class A category with property of being termite / borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast of required dia and length all as specified and directed by Engr-in-Charge.
S & F factory made 100% solid WPC (wood polymer composite) solid decorative on both side flush door shutter of required size comprising of virgin PVC resin of 'K' value 57-60 (suspension grade) calcium carbonate and natural fibre (wood powders/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density 650Kg/cum and screw withdrawal strength of 1800N (face) & 900N (edge), minimum compressive strength 50 N/Sqmm, modulus of elasticity 850N/ sqmm and resistance to spread of flame of class A category with property of being termite / borer proof, water/ moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 micron thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with SS butt hinges of required size with necessary full body threaded screws complete all as specified and directed by Engr-in-Charge. Note- SS butt hinges and necessary SS screws will be paid separately.
S & F Butt hinges, 100 mm long extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and directed.
S & F aluminium anodised, 200mm length of bolt and fixed with screws, complete all as specified.
S & F 150 mm size, aluminium anodised handle and fixed with screws complete all as specified.
S & F 300 mm long aluminium anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy and fixed with screws complete all as specified.
S & F floor door stopper aluminium anodised overall length of cover plate of size 140 mm long with hard drawn steel spring complete all as specified and directed .
S & F Mild steel powder coated 1 mm thick built in cupboard shutter with frame of approved colour ,cupboard frame should be 150x20mm size domestic type and fixed with (i) Hold fast of as per requirement for frame (ii) 1 No. handle in each shutter (iii) 1 No. Mortice lock in each cupboard (iv) Peg set of three pegs fixed with each shutter.complete fixed in repairs i.e, incl taking down and removal of old unserviceable wooden or steel built-in-cupboards incl frame from site complete all as specified and directed.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
M & L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for preparation of old steel surface of any description exc. 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M & L for preparation of old wooden surface of any description exc. 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
S & F aluminum section powder coated of colour as approved door with frame and shutters partially glazing 5.5mm thick one side plain/colour glass and PVC composite board 5mm thick fixed with aluminium clip beeding. door section of aluminium door shutter as under complete and all as specified and directed (I) Frame 100x40x2mm (ii) shutter style 85x44.45x3mm thick section (iii) Top rail 95.25 x44.45x1.7mm thick (iv) middle rail 83.50x44.75x1.7mm thick (v) Bottom rail 114.30X44.15X1.7mm thick section (vi) Glazing clip 0.7mm thick (vii) 2 Nos Handle Powder coated Aluminium 200mm long as approved (viii) Tower bolt 9.90mm dia and 200mm long (ix) Mortice lock 100MM 7 LIVER (x) Hold fast aluminium 100mm long (xi) Reinforced with 2 No 10mm dia MS bar with bolt complete on top and bottom rail of door complete all as specified and directed. (Note: PVC/rubber lining brush for alround door).
S & F Aluminium anodised powder coated frame (minimum thickness of powder coating 50 micron) of colour as approved by GE for frame for doors, windows, ventilators with one or mor rebate including jointing cleat for fixing, etc. complete all as specified and directed.
S & F in repair fancy type decorated Stainless Steel curtain hanging rods 20 mm dia,and fixed to stainless steel bracket for hanging curtain complete all as specified and directed.
S & F Stainless Steel brackets having screw for tighting of curtain rod of 20mm dia for fixing of curtain rod, complete all as specified and directed.
S & F Stainless Steel bright color decorative corner/end cap for Curtain rod complete all as secified and directed.
S & F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed .
S & F in repair CP vitreous china soap dish fancy type complete all as specified and directed.
S & F in repair Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
S & F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed.
S & F in repair Vitreous china premium/1st quality wash down water closet pattern incl all necessary accessories like rag bolts/gel gasket etc. (excluding flushing cisteran & flush pipe) complete all as specified and directed.
M & L for PVC water closet seat cover , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flush ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
S & F in repair Vitreous China wash basin, table top white, including 32mm dia pvc waste pipe excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed. Make : Cera Cat No S2020177 or equivalent
S & F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed.
S & F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed.
S & F in repairs for 15 mm bore pillar taps CP fancy type screwed down high pressure with long shanks and fly nuts screwed for iron pipe Hot or Cold with long screwed and fixed complete all specified and directed. Make : Cera Cat No F2014104 or equivalent
S & F in repair PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
S & F 1000 ltr Rotational moulded polythene water storage tank white coloured triple layered (cylindrical vertical with closed top) hoisted and fixed in position on roofs complete as per SSR Part-1 complete all as specified and directed.
S & F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed.
S & F CI Gate valve, 20mm bore, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or unions complete all as specified.
S & F CI Gate valve, 15mm bore, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union complete all as specified.
Cutting chases , pinning in, making good to facing where required to and pointing in cement mortar 1:3 for concealed water tubing and making good complete all as specified and directed.
Refixing old 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
Refixing old 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
S & F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including taking up or down old steel tube complete all as specified and directed.
S & F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including taking up or down old steel tube complete all as specified and directed.
M & L for post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed.
S & F in repairs 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.
S & F in repairs 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S & F in repairs 75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.
S & F in repairs 75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement complete all as specified and directed.
S & F in repairs PVC (SWR) junction single, (Single T 110mm), equal or unequal with access door complete all as specified and directed.
S & F in repairs PVC (SWR) junction single, (Single T 75mm), equal or unequal with access door complete all as specified and directed.
S & F in repairs PVC(SWR) bends, for 110mm bore pipes, with access doors, all as specified.
S & F in repairs PVC(SWR) bends, for 75mm bore pipes, with access doors all as specified.
S & F 110 mm PVC (SWR) vent cowl Complete all as specified and directed.
M & L PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified directed.
M & L For cutting out cracks to v-section in existing roofs or terraciv cleaning grouting with cement and sand slurry 1:1 complete all as specified and directed.
M & L For cutting grooves in brick wall 75mm wide and 65mm deep & shaping horizontal face of groove with cement complete all as specified and directed.
M & L PCC 1:3:6 type B-1(using 20mm graded stone aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
M & L for rendering or bedding layer 15mm thick in cement mortar (1:4) over concrete surfaces of roof, mixed with WPC as per manufacturer's instruction including finishing surfaces even and fair without using extra cement complete all as specified and directed.(Note: WPC will be measured and paid separately).
M & L for preparation of new surface and applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed.
M & L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer complete all as specified and directed.
S & F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type of colour as approved, aluminium section weighing not less than 0.55 mm kg/m including necessary jointing cleats, fixing of glass panes, glazing clips, rubber neoprene packing, powder coated aluminium snap beading, screws and locking arrangement etc complete all as specified and directed. Note: Glass pane shall be measured and paid separately as supply only in respective item.
S & F heat resistance terrace tiles (300mm X 300mm X 9-10 mm thick) with SRI (Solar refractive index) >78 solar reflection>.70 and intial emittance >0.75 on waterprof and sloped surface of terrace laid on 15 mm thick cement sand mortar in the ratio of 1:4 and grouting the joints with mix of white cement & WPC as per manufacturer's instruction complete all as specified and directed.
Roughening of existing PCC floor surface by picking,sweeping, clean and washing down with water to remove dust to receive cement mortar for tiling, incl brushing neat cemet slurry with 3.0 Kg of cement per sqm complete all as specified and directed.
M & L for machine cut Kota stone slab flooring 18-20 mm thick in flooring, treads, landings of stair case etc. over cement screed bed laid and jointed wilth grey cement slurry mixed with pigment to match the shade of the slab lincluding & grinding polishing over and including screed bed 20mm thick in cm (1:6) complete all as specified & directed.
M & L for 18 to 20 mm thick machine cut Kota stone slab as in skirting, risers , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 10 mm thick in cm (1:3) complete all as specified and directed.
M & L for 18-20mm thick granite work table rubbed and polished for wall lining /kitchen platform over 12mm thick cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for 18- 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for Acid registant tiles 15 mm thick vitreous ceramic unglazed ,set, jointed and pointed in chemical resistant mortar , resin type in floors over 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed.
M & L for Glazed ceramic tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match on vertical surface such as skirting , dado etc. over 10 mm thick backing coat plaster in CM 1:4 complete all as specified and directed.
M & L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded agg) for plinth protection complete all as specified.
Supply only liquid integral water proofing compund. Make Dr Fixit/ Pidipfoor/ LW+.
M & L for sunkan portion incl demolation of existing PCC,WC,P/S Trap and removing the material out side MD land.& (a) preparation of RCC surface of sunken slab (floor) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- 1. continuty with cementitious water treatment beyond sunken portion in toilet shall be maintaned.
M & L for cement concrete type E2 1:5:10 (40mm graded stone aggregate) as lean concrete in filling / Mass concrete complete all as specified and directed.
M & L for Brickwork with subclass "B" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of using class designation 100 of bricks in lieu of 75 all as specified and as directed.
M & L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC as per manufacturer's instruction, surfaces finished even and fair without using extra cement complete all as specified and directed. Note : WPC measured separatly respective item.
M & L for rendering 5mm thick in CM 1:3 finished even and smooth without using extra cement in ceiling complete all as specified and directed.
M & L for preparing new plaster surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of new plaster surfaces of walls and applying two coats of 1st quality acrylic emulsion paint of approved manufacturer, of required shade and colour incl providing and applying Birla putty 1-2 mm thick over a coat of primer complete as per manufacturer's specification complete all as specified and directed.
M & L for Preparation of new plastered surface of wall and finishing the walls with acrylic smooth exterior paint of required shade two coats applied @ 3.28 ltr / 10sqm over and including priming coat of exterior primer applied @ 2.2 Kg/10 Sqm) incl providing and applying Birla putty 1-2 mm thick complete all as specified and directed.
M & L for preparing new plaster surfaces of ceiling and applying two coats of distemper oil emulsion over coat of primer complete all as specified and directed.
M & L for complete removal of existing treatment of walls and applying two coats of 1st quality acrylic emulsion paint of approved manufacturer, of required shade and colour incl providing and applying Birla putty average 1.5 mm thick (not less than 1mm thick) over a coat of primer complete as per manufacturer's specification.
M & L for complete removal of existing treatment on Walls surface and finishing the walls with acrylic smooth exterior paint of required shade two coats applied @ 3.28 ltr / 10sqm over and including priming coat of exterior primer applied @ 2.2 Kg/10 Sqm) incl providing and applying Birla putty average 1.5 mm thick (not less than 1mm thick) complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified.
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe-410- W(GdeE-250) quality-A etc complete all as specified and directed.
M & L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)f orming holes, without any attachment Confirming to Fe-410- W(GdeE-250) quality-B etc complete all as specified and directed.
Providing & fixing false ceiling at all heights with semi peforated 12 mm thick micro tangular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of 12mm Size 595mm x 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS tiles tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge
Taking down of cement plaster or Removing all loose spalled concrete to the depth of sound concrete and expose the corroded rod from structural part of building incl cleaning of rust and apply a coat of Nitoprime Zincrich or equivalent to exposed surface of reinforcement and allow to dry complete all as specified .
M & L for 40 mm thick rendering in CM 1:4 two layers (20mm each layer) with using Chemical mixing properaly as per mfd instruction on the Colounm, beams, roof slabes, parapit walls and chhajas, and other structural parts of bldg and finished even and smooth without using extra cement complete all as specified and directed. (Note: Supply of Chemical Paid saperetaly)
Supply only Chemical ( Nitobond SBR of FOSROC or equivalent ) complete all as specified and directed.
M & L for concrete bed to drain pipe including packing under and hunching against the sides of pipe after they are laid and tested in PCC (1:3:6) type C-2 using 40 mm graded stone aggregate for 150 mm bore pipe complete all as specified and directed.
M & L Reinforced concrete bore of pipes 150mm dia class NP2 laid to shape in trenches and jointed in CM (1:1) complete all as specified and directed.
M & L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in foundation bed of manhole complete all as specified and directed.
M & L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in benching including weathering slightly rounded or chamfered angle etc. and necessary form work as required finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed.
M & L for precast reinforced cement concrete in (1:2:4) type B1, using 20mm graded stone aggregate as in cover slab for man holes etc ste in CM(1:4) complete all as specified and directed.
M & L TMT bar 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed.
S & F Neoprene/ EPDM rubber gasket for fixing glass panes in aluminium window fixed portion complete all as specified and directed
M & L for 50mm thick sand stone slabs in sunshade, chajja, shelves, cills, landings etc not exc 2 m in length punched dressed on face and along exposed edges self faced on other side and set and pointed in CM 1:4 complete all as specified and directed
M & L 60 mm thick M-35 Grade machine pressed precast concrete interlocking paver lock with grey cement and pigment any shape and size conforming to IS 15658-2006 over and including dry sand cushioning 30 mm thick all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked including cutting and chasing and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for one light point / fan point / exhaust fan point / bell / buzzer controlled by one 1-way switch/ bell push and making good surface as original by plastering and whitewash/ colour/ distemper etc, complete all as specified and directed. (Note : The cost of modular type Metal boxes and modular accessories like inner/outer cover plates etc will be included in quoted rate.)
All as per srl item No. 125 here in before but with point wiring for one socket outet point 5 amps on the independent board.
All as per srl item No. 125 here in before but point wiring for one socket outet point 5 amps on the Same board with other switchs complete
Material and labour for point wiring complete with 2.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked including cutting and chasing and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including FRLS PVC insulated unsheathed 2.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for 15 Amp light point and making good surface as original by plastering and whitewash/ colour/ distemper etc, complete all as directed. (Note : The cost of modular type Metal boxes and modular accessories like inner/outer cover plates etc will be included in quoted rate.)
Supply & fixing of Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing of Modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing of Modular socket 6 Amp, 2/3 pin, multipurpose shuttered type, 2 module size complete all as specified and directed.
Supply and fixing of Modular socket 16 Amp mulipurpose shuttered type, 3 module size complete all as specified and directed.
Supply and Fix calling bell AC ding dong 220 volt multi music type complete all as specified and directed.
Supply and fix Modular bell push AC 220 volt single phase complete all as specified and directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note :- All old fan shall become property of the contractor and affecting recovery as per rate mentioned in schedule of credit.
Supply and fix exhaust fan steel body 300/308mm sweep, heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery discharge 6120 CMH suitable for SP, 230/250 volts, 50Hz, AC supply with louver shulter complete all as specified and directed. Note :- (i) Unit quoted rate shall be deemed to include the cost of making suitable dia of hole in wall and finished the surfaces to match the existing schedule of finishes. (ii) Make Havells Ventil Air - DX white or equivalant in crompton / Bajaj
S & F sheet metal single pole and neutral enclosure with two pin and earth plug and socket capacity 20-32 Amps complete with one No SP MCB 20-32 Amps complete all as specified and directed by Engineer -in -Charge.
S & F in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fix in replacement of polycarbonate ceiling rose surface mounted complete all as specified and directed.
Taking down carefully MCBs at site all as per directed by engineer-in-charge
Taking down carefully MCCBs at site all as per directed by engineer-in-charge
Supply and fixing of MCB 'C' Curve, 10 kA, 6 to 32 Amp, SP with over load and short circuit protection complete all as directed.
Supply and fixing of MCB 'C' Curve, 10 kA, 40 to 63 Amp, SPN with over load and short circuit protection complete all as directed.
Taking down carefully SPN/ TPN DB materials at site all as per directed by engineer-in-charge
Supply and fixing of Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB's and isolators etc and making all necessary connections complete all as directed. Note: The cost of removing old wooden box and making good of surface as original i.e. brick work, plastering, white washing etc is included in quoted rate.
Supply and fix Verticle type TPN DB MCCB 160 Amp as incommer 4 way with three phase and single phase (TP/SP) MCB out going comprising 200 Amp insulated bus bar (Tinned electrolight copper) arrangement, shrouded neutral bar and earth bar, top and bottom removable gland plates, IP-43 protection, 440 volt 50 Htz Complete as all directed as specified by Engineer-in-Charge Note : MCCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix MCCB four pole 160 Amp rating 36 KA 415volt 50 Htz adjustable type including spreader link for both side incomer and out going Complete as all directed as specified by Engineer-in-Charge
Taking down carefully sub main wiring 4sqmm & 6sqmm with conduit at site all as per directed by engineer-in-charge Note :- The two run of 4/6 Sqmm wire and one run of 4/6 Sqmm wire will be measured as one unit.
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB Complete as all directed as specified by Engineer-in-Charge. Note : 1. The conduit and conduit accessories shall be deemed in quoted rate no extra payment will be made in this account. 2. The two run of 6 Sqmm wire and one run of 4 Sqmm wire will be measured as one unit.
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB Complete as all directed as specified by Engineer-in-Charge. Note : 1. The conduit and conduit accessories shall be deemed in quoted rate no extra payment will be made in this account. 2. The two run of 4 Sqmm wire and one run of 4 Sqmm wire will be measured as one unit.
Taking out old unserviceable earthing and M&L for new earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Taking down carefully cable of any size materials to store for keeping in safe custody for reuse at site all as per directed by engr-in-charge
Taking down carefully LT Panel of any size materials to store for keeping in safe custody for reuse at site all as per directed by engr-in-charge
Supply, laying, testing, Jointing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 185 sqmm 3 .5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed.
Supply, laying, testing, Jointing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3 .5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed.
Excavation in trenches in soft/ loose soil not exc 1.5m wide and not exceeding 1.5m in depth for laying of cable, errection of poles,stay and pipe line, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated surplus materials to a distance not exec. 50m and depositing where directed at a level not exc. 1.5m above the starting point all as specified and directed.
S & F clean dry sand as in sand cushioning to underground cable laying 8 cm thick before laying and 15 cm after laying the cable in trenches for cable cushioning and gently punned down complete all as specified and directed. Note-Only punned depth 18 cm of sand shall be measured for payment.
Material and labour for Sub class 'B' bricks laid dry, flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid complete all as specified.
Supply, installation, commissioning and testing LT panel board,conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral , outdoor type (Kiosk) with apron, of suitable size , factory made , fabricated with 3.15mm thick mild steel sheet ( Outer Body) , ISMC-75 base channels, duly powder caoted internally and externally with approved shade, rubber gasketted , hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof , complete including suitable size lugs, glands . One No brass pad lock of Harriosn/link , 50mm size, 4 levers and making connections , earth work and PCC foundation complete comprising of the followings and specified hereafter:- (i) Aluminium bus bar 400 Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick (ii) Cable alley for I/C 150 Amps and 02 outgoing feeders Incoming :- (a) MCCB 250 Amps 36 KA 4 Pole, 415V, adjustable type -01 NOS (b) Meter module digital volt and amp meter of appropriate size with accessories -01 Nos Outgoing- (a) MCCB 125 Amps 16 KA 4Pole 415V,adjustable - 02 Nos Note: Cable glands should be provided for all incoming /outgoing connections.
Supply, installation, commissioning and testing LT panel board,conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral , outdoor type (Kiosk) with apron, of suitable size , factory made , fabricated with 3.15mm thick mild steel sheet ( Outer Body) , ISMC-75 base channels, duly powder caoted internally and externally with approved shade, rubber gasketted , hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof , complete including suitable size lugs, glands . One No brass pad lock of Harriosn/link , 50mm size, 4 levers and making connections , earth work and PCC foundation complete comprising of the followings and specified hereafter:- (i) Aluminium bus bar 600 Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick (ii) Cable alley for I/C 150 Amps and 02 outgoing feeders Incoming :- (a) MCCB 350 Amps 36 KA 4 Pole, 415V, adjustable type -01 NOS (b) Meter module digital volt and amp meter of appropriate size with accessories -01 Nos Outgoing- (a) MCCB 250 Amps 36 KA 4Pole 415V,adjustable - 02 Nos Note: Cable glands should be provided for all incoming /outgoing connections.
taking out old unserviceable existing earthing system and M & L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mts deep below ground level with top edge of the plate not less than 1.50 mtr below ground level connected to galvanised strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC pit (1: 3: 6) type C-1 using 20mm graded stone aggregate, RCC cover 40 mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia , plastering 15 mm thick CM (1:6) externally upto 150 mm below ground level , GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing test results on a 3.0 mm thick painted Mild Steel earth pit marking plate (200 mm x 100 mm ) duly welded with a 450mm long 10mm dia round MS rod , fixed with the earth pit chamber by grounting complete including demolish with old pit chambers and removing of debris from the site with levelling the ground all as specified an directed by Engr-in-Charge.
Z N Enterprises
M/s NSA Engineering Corporation
POOJA ENTERPRISES
M/s DHARAM VIR GHAI
M/S Amar Enterprises
R.K.ASSOCIATES
Ashirwad Contractor and Supplier
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .