Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹4.0 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹4.1 Cr+₹4.6 L (1.13%)Rejected-Finance | ₹4.1 Cr+₹4.6 L (1.13%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹4.6 Cr+₹59.6 L (14.7%)Rejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | ₹4.6 Cr+₹59.6 L (14.7%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹4.7 Cr+₹70.3 L (17.4%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | ₹4.7 Cr+₹70.3 L (17.4%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹4.8 Cr+₹72.0 L (17.8%)Rejected-Finance | ₹4.8 Cr+₹72.0 L (17.8%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹4.8 Cr
EMD Value
₹5.6 L
Closing Date
7 Feb 2023, 6:00 pmClosed
Chief Enngineer Pathankot Zone
HQ Chief Engineer Pathankot Zone Pathankot
PROVN OF ALT EXIT ROAD NEAR GD POST NO 3 AT BIRPUR RATNUCHAK
2022_MES_570471_1
CEPZ-19/2022-23
Open Tender
Civil Works
Lump-sum
456 days
GE (P) Jammu
All as per tender documents
7 documents required · 7 mandatory
₹2,000
GE (P) Jammu
₹5.6 L
Yes
1 Apr 2023
21 Dec 2022
15 Feb 2023
21 Dec 2022
7 Feb 2023
24 Jan 2023
Amount
Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal water supply as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Plumbing Works as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Internal Electrification Works as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Protective Works as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Site Clerance and development as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Road, Path, Culvert and PCC Hardstanding Works as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Sewage Disposal as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for AREA DRAINAGE (DRAIN TYPE ‘B’) as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Security wall/fencing and Gate as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for Summer applicances as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for Hot Water Supplyas listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for External Water Supply Works as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the contractor for External Electrifcation Works as listed in Schedule 'A' Part-XIV.
Lumpsum price worked out by the contractor for Demolition/Dismantling Work as listed in Schedule 'A' Part-XV.
INTERNAL ELECTRIFICATION :
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings including LED Bulb 10 Watt complete all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 KA, of rating 6 to 32 Amp all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA, of rating 6 to 32 Amp all as specified and directed.
M & L for earthing complete with G. L earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL with top edge of the plate not less than 1.5 m below the normal ground level connected GI wire earth lead wire 4.0 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 M, including PCC chamber PCC (1:2:4), type B1, using (20 mm graded stone aggregate), mild steel frame made out of angle iron of size 40 mm x 40 mm x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick Cl cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia light grade Gl pipe for watering, 15mm dia medium grade, Gl pipe for earth wore protection with and including alternate laver of charcoal dust and common salt. Complete all as shown in electrical plate No 3 connected to DBs all as specified and indicated including testing on completion. Note :- (i) Gl wire upto 7.5m will be measured and paid under this item only extra lead will be measured and paid separately under relative link.
S&F security LED street light, 1X20 Watt, 230 volt, energy saving and environmental friendly long life versatile pressure die cast aluminium IP – 66 road way luminary with high power LED as light source and electronic driver
S&F wall fan air, 55 m3 / min including mounting accessories.
ROAD, PATH AND CULVERT WORKS
Providing & applying 2.5mm thick road marking strips (retro- reflective) of specified shade/colour using hot thermoplastic material by fully/semi automatic thermoplastic paint applicator machine fitted with profile shoe heater, driven by experienced operator on road surface incl cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc complete as per direction of Engr-in-Charge and accordance with applicable specification complete all as specified and directed.
Solar rod having 6 LED of colour red/yellow house in plastic body cell battery and light sensor well protected in side polycarbonated sheet device protected with power coated wire mesh cage system mounted over 80 mm dia steel tube powder coated of length 900 mm having sheet footed for firm grip to ground. System workable for 8 to 10 hours
Solar cat eye having 3 LED /side of colour red/yellow to a side ( 6nos) house in tough pressure diecasted aluminium allow of size 125mm x 125mm x 25 mm with built in steam of suitable length for fixing with approxy LED solar cell battery and light sensor well protected in side under tough under cable for 2 to 3 days (night) after full charge in 8-10 hours.
Stainless steel round road delineator having reflector type red/yellow colour in plastic body protected in side polycarbonated sheet, protected with powder coated wiremesh cage system mounted as approved by Engr-in-Charge.
Reflective type cat eye having colour red/yellow to a side, casted aluminium allow of size 100X100X20mm with built in steam of suitable length for fixing with protected in side as approved by Engr-in-Charge.
Information board with ACP sheet retro reflective writing one side size 600mm x 900 mm. Made around of reflective intensive tape dully fixed on angle iron frame 40 x40x4 mm frame with aluminium sheet both side 2mm thick as required with PCC 1:4:8 type D-2 for post and PCC 1:2:4 type B-1 for platform size 5'x3' complete all as specified and directed by Engr-In-Charge.
SEWAGE DISPOSAL
M&L for septic tanks on site LLDPE Conventional type PCC bed, brick work incl sludge chamber septic tank designed to carry sewage and sludge water comprising earthwork, excavation, returning filling, disposal of surplus soil to a distance not exceeding 50 mtr in any type of of soil, PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) in foundations, 200mm thick, vent shaft connection etc complete for 10 users (1600 Ltrs capacity ) including all fittings, fixtures testing on completion approximate dimensions.
M&L for Soakage well excavation in any type of soil foundation in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregagtes), walls of honey combed masonry with toping in M25 concrete including intercepting chamber and serum chamber made of brick masonry in cement motar , RCC cover slab in M-25 inter connecting pipes of RCC complete filed with brick bats of size 1.80m x 3.00m effective depth including earthwork.
SECURITY WALL/FENCING AND GATE
S&F Concertina coil fencing with punched tape concertina coil 600mm dia, stretched to 6m length, having 50 Nos spiral turns per 6 metre length, spring core (2.59mm thick) of high tensile strength of 1620 N/Sqmm with tape (0.52 mm thick) Hot dia galvanised upto 20 microns, weight of each coil 8.50 kg and fixing the same on existing Y- shaped angle iron with 6 horizontal R.B.T (reinforced barbed tape) wire, stud tied with Gl staple and Gl clips to retain horizontal, clips shall be @ 5 Nos per 2 spiral turns approximate 125 clips per coil including necessary bolts complete all as specified and as directed.
SUMMER APPLIANCES
Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with out put voltage stabilized at 230 V with accuracy of +/-2.5 % and of capacity 01 KVA.
Supply and install Desert Cooler with steel body having 450 mm fan size with Aluminium blade ISI Marked electric driven (Single phase) having nominal air flow capacity 4000 Cum per Hour with wall thickness of sheet 1 mm and Water tank and body pillar 1.5 mm thick including prewired electric control panel with immersed pump duly ISI marked pump and Fan motor.
STANDBY DG SET
Supply, installation, commissioning and testing of Diesel engine driven Air cooled generating set of capacity 7.5 KVA, 415 volts, BHP as per manufacturer recommendation, AC supply, 50 Hz, 3 phase 4 wire, 0.8 PF at NTP, speed 1500 RPM mounted on common base frame with flexible coupling and meeting the requirement of IS-4722/BIS specification with CPCB approved acoustic enclosures fabricated out of CRCA sheets as per manufacture recommendation. Sound proofing of enclosures is done with high quality foam conforming to IS-8183 for 75 dBT 1 mtr complete including PCC foundation in all respect as per norms of OEM.(a) DIESEL ENGINE : Air cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specification, 12 volts self starting including maintenance free battery of suitable capacity, charging dynamo/ alternator, air cleaner, diesel/ oil filters, complete in all respect. The engine shall be capable of taking 10% over load for one hour for every 12 hours running confirming to the environment (PROTECTION ACT 1986) and as amended vide Gazette of India Notifications Part-II sections-III Sub Section (I) dated 12 Jul 2004. (b) FUEL TANK : In built fuel tank of adequate capacity for 12 hours running with stop cook, drain plug as per recommendation of OEM (c) ALTERNATOR : 7.5 KVA at NTP AT Jammu, 3 Phase, 50 Hz, 415 volts, AC supply, 0.8 PF at 1500 RPM, this shall be self excited screen protected and drip proof type brushless, conforming to relevant IS/BIS code as per latest manufacturing schedule. (e) CONTROL PANEL : The standard control panel shall be built in acoustic enclosures with the following accessories complete wired with suitable size of copper cable :-
(i) MCCB of suitable rating with over load and short circuit protection. (ii) Digital Ammeter. (i) Digital voltmeter. (ii) One set of indicating LED lamps RYB and fuses. (iii) Frequency meter, Hour meter, Fuel level indicator. (iv) KWH meter of suitable capacity digital type for 3 phase 415 volt AC supply and for unbalanced load. (v) Water temperature gauge, oil pressure gauge. Note : The Gen set must be affixed with label meeting the following requirement (The label shall be durable and legible) (a) Name and address of the engineer manufacturer. (b) Statement that this engine conforms to the environment (PROTECTION) (c) Type and approval certificate number. (d) Date of manufacturing of gen set. (e) Acoustic enclosure : Acoustic enclosure should be as per manufacturer recommendation. The walls of enclosures will be insulated to get 75 dba at 1 mtr sound leveled as recommended by ministry of environment and forest. The enclosure shall have following provisions (i) Fitting arrangement (ii) Point for neutral and body earthing (iii) Fuel drain (iv) Lub oil drainage (v) Air breather (vi) Easy stop push button(vii) Panel meter viewing window (viii)Tube light fitting 1x14 watt-02 Nos Note : (i) DG set should be sound proof as per latest policy. (ii) First filling of Engine oil and Fuel etc should by arranged by contractor for testing.
Material and Labour earthing complete with galvanised steel earth plate electrode 600mmx600mm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge, of the plate not less than 1.5 m below normal ground level, connected to the Galvanised Iron earth lead 32mmx6mm (Gl Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of Gl medium grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1:2:4) type B-0,reinforced with XPM (weight not less than 4 kg per sqm) and frame of angle iron 40mmx40mmx3mm dia MS bar handle made to shape, Gl light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50mtr and removal of surplus soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillars and Transformer all as specified including testing on completion all as specified and directed.
EXTERNAL WATER SUPPLY
Construction of valve pit chamber of following sizes with brick masonry, one brick thick wall in cement mortar (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation complete including necessary exc and earthwork in any type of soil, formwork, 15 mm thick cement & plaster rendering internally all around over brick work & externally upto 15 cm below normal Gl with 10 SWG thick MS sheet cover including 40mm x 40mm x 6mm MS angle frame fixed locking arrangement and painting with one coat of red oxide and two coats of black Bituminous paints of size 1200mmx1200mmx1350mm.
EXTERNAL ELECT SUPPLY
S&F Pole mounted junction box, Degree of protection IP54 fabricated out of 3mm thick MS sheet of size 300mm x 200mm x 100mm, front openable door with hinges, weather proof duly painted internally and externally over a coat of red oxide primer suitable to house and including colour coded 04 Nos aluminium bus bar of 63 Amps rating mounted on insulators, one No MCB SP 6 Amps mounted on dinrail suitable ot accommodate 02 Nos MCB SP, internally wired with suitable size of copper conductor, provision of bottom cable entry with cable glands for connecting street light fittings.
Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accommodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing MCCB, MCB and TPN Aluminium bus bars of rating not less 1.5 times the rated cap of incomer MCCB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/ epoxy insulator of conical type at an interval of not more than 500 mm throughout the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links/ interconnection shall be insulated with heat shrinkable colour coaded sleeves. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armored cable of adequate size with glands. The above panel shall be front and back openable lockable / openable by key from both side and shall have louvers and air vent gasket for natural flow of air 3mmXPLE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection, complete as specified and consisting the main Incoming MCCB FP 32 A 415 Volts 25 KA Outgoing MCB TP 16 A 415 Volts 16 kA-02 Nos On load change over switch 32 Amps 4 pole – 01 No MCB SPN 20 Amps -02 Nos MCB SPN 16 Amps -01 No Light Sensitive Timer -01 No 3 Pole Contactor 10 Amps -01 No LED Type RYB Phase Indicator – 01 Set Digital VAFPF Meter -01 No CTs – 01 Set
Material and laying Earthing complete with Gl earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 mm deep below Gl) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of Gl medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) type B0 ( using 12.5 mm graded crushed stone aggregates) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6 mm dia MS bar handle made to shape, Gl medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements funnel wire mesh and earth work in any type of soil, returning in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point / poles / distribution boards all as specified or indicated including testing on completion all as specified and directed (Pole-07 Nos, ESP-02 Nos, Guard Rest Room-02 Nos)
Material and laying earthing complete with galvanised steel earth plate electrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top prjgc, of the plate not less than 1.5m below normal ground level, connected to the Galvanised Iron earth lead 32mmx6mm (Gl strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of Gl medium grade pipe 40mm bore including provision of aggregates with 40mm thick cover of RCC (1:2:4) type B0 ( using 12.5 mm graded crushed stone aggregates), reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made ot shape, Gl medium grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplus soil to plate No 3 SSR 2009 Part-I and connecting to feeder pillars and Transformer all as specified including testing on completion all as specified and directed.(Feeder Pillar-02 Nos)
Supply , lay /passing thorough pole / pipe / fix along the walls / pillar, copper conductor cable 1100 Volts Grade of size 1.5 sqmm x 3 core, PVC insulated and FRLS PVC round sheathed complete all as specified and directed by the Engr-in-charge.
Supplying and fixing cable route indicator for LT Cable of 10 cm dia Cl plate 6mm thick embossed with raised lettering LT cable 433 Volts painted with luminous paint and mounted on angle iron 25x25x3mm and 0.6 mtr long embedded in PCC block 1:2:4 (size 30cmx15xcmx15cm) type B-1 (Using 20mm graded crushed stone aggregate) all as specified and directed by the Engr-in-Charge.
Supply and fixing Bracket made of GI pipe 40 mm dia (light grade) with attachment of suitable size of MS claims for fixing street light all as specified and directed by the Engr-in-Charge.
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 3241.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
bamral builder
M/s Khajuria Construction Co.
Mehar Enterprises
M/S BHATIA BUILDERS AND CONTRACTORS
R R CONSTRUCTION
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
Sanjay Constructions
M/s Ravinder Kapoor Engineers and Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .