Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 CrAdmitted-Finance E 103 1ST FLOOR SALDANHA BUSINESS TOWERS ALTO MAPUSA GOA | ALTO MAPUSA | GOA | +4.60% | ₹2.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.2 CrAdmitted-Finance HNO 1131 TIVIM BARDEZ GOA | TIVIM | BARDEZ | GOA | 403507 | +8.90% | ₹2.2 Cr | L2 | Admitted-Finance |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
17 Mar 2026, 5:00 pmClosed
Executive Engineer
O/o Executive Engineer Elect. Dept. DIV-XVII Mapusa
30MLD water treatment plant near ITI Pernem 33KV
2026_ED_28136_1
53(25-26)/5545 Dt06/03/2026
Open Tender
Electrical Works
90 days
near ITI Pernem
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
₹4.0 L
7 Apr 2026
10 Mar 2026
18 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
COST OF MATERIAL
Supply of XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY for 250 mtr (Double run) + 20 mtr extra
Supply of 3 WAY RMU, 33 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) IAC-AFLR 25 KA is for SF6 tank and cable work, 630 A with no darating @ 50 deg C and VCB making capacity of 62.5 KA with INGI enclosure with manual operated earthing switches in SF6 and 2 VCB with electrical closing and tripping along with disconnector and earthing switches SCADA competable. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Current transformer and numerical relay with communication in all CB module. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
Numbering of RMUs and poles with paint
Supply of GI Flat 50 x 6 mm
Supply of Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
Supply of H. S. 33KV Indoor Temination Kit for 3C 400 Sq.mm XLPE
Supply of Modem for Automatic Meter Reading (CAMR)(inclusive of labour charges
Supply of 33 KV Metering cubicle complete
Life Extension and Reliability Enhancement of 33 KV Outdoor metering cubicle i) Epsilon High dielectric strength 15 KV tape on bus bars (1.8 m) and joints in 63 mm and 25 mm widths as required ii) Epsilon G4 Elektrosafe Non-flammable coating on epoxy / ceramic insulators and CT and PT for flashover risk reduction iii) Epsilon G4 Elektrosafe Non-flammable high diaelectic strength coating on inner panel walls in high-risk segments for reducing flashover risk iv) Epsilon G 4 External surface coating for marine grade corrosion prevention
Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
Supply of cable route Markers (for entire route length) [Proposed one for every 10 mtrs]
Bricks class design 75 kg/cm2 (1st class wire cut)
warning Tape
COST OF ERECTION
Erection of XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY for 250 mtr (Double run) + 20 mtr extra
Erection of 3 WAY RMU, 33 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB : Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) IAC-AFLR 25 KA is for SF6 tank and cable work, 630 A with no darating @ 50 deg C and VCB making capacity of 62.5 KA with INGI enclosure with manual operated earthing switches in SF6 and 2 VCB with electrical closing and tripping along with disconnector and earthing switches SCADA competable. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Current transformer and numerical relay with communication in all CB module. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxiliary PT as per specification shall be provided in RMU.
Erection of GI Flat 50 x 6 mm
Erection of Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
Erection of H. S. 33KV Indoor Temination Kit for 3C 400 Sq.mm XLPE
Erection of 33 KV Metering cubicle complete
Laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
Installing of cable route Markers (for entire route length) [Proposed one for every 10 mtrs]
CIVIL WORK
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in hard rock where blasting prohibited (of size 1.3 x 0.6 x 250 Mts)
Re filling the pipeline foundation trenches plinth sides foundation etc with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by the engineer in Charge (of size 1.1 x 0.6 x 250)--118.80 Cumt --Deduct for RCC slab - [(0.6*0.25*0.05)*no of slabs]---6.26 cumtr Total refilling
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete, sand (of size 0.2x 0.6 x 250)---20 Cumtr --Deduct for 33 KV Cable ( 3.14x0.05x0.05)x total length x no. of run---3.93 Cumtr --Deduct for bricks (0.2 x 0.1x0.1)x no. of bricks---2.50 Cumtr Total Sand
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) All works upto plinth level
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns
12mm cement plaster 1:4 (1 cement : 4 fine sand)
Refilling the pipeline/ foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Transportation and carriage of materials (A) By tipper truck including loading, unloading and stacking (A) Lime, building rubbish, manure sludge, moorum excavated rock (ii) Earth (upto 5 km)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_28583.pdf
techsummary_28583.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 21.41 MB
Tendernotice_2.pdf
PDF • 5.76 MB
Tendernotice_3.pdf
PDF • 0.73 MB
BOQ_28583.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid