GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
MAINTENANCE OF AC PLANTS AT TECHNICAL AREA AND CERTAIN REPAIRS OF INSTALLATIONS UNDER GE(I) R AND D KANPUR.
2022_MES_512078_1
8280/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹23,600
Yes
13 May 2022
5 Mar 2022
30 Mar 2022
5 Mar 2022
28 Mar 2022
14 Mar 2022
5 Mar 2022 - 10 Mar 2022
60 days
Amount
Maintinance and servicing of central AC Plant 21 TR/Package type AC Plant 22.5 TR in a month including repair of minor spare parts and repair works, tighting of nuts, repairing unserviceable parts, and accessories, ,servicing of pump etc , Cleaning of dust from condensor unit with the help of blower and washing with water through pressure pump ,servicing of moter oiling, greasing well cleaning with petrol /CRC-226, complete all as specified and directed etc complete all as specified and directed.
M&L for Checking of leakage by charging of nitrogen gas in the refrigration system , pressure testing and rectification of leakage complete all as specified and directed.
M&L for charging refrigerant R407C in the system of Air cooled scrolled type water chiller machines including checking and rectification of leakages completeall as specified and directed.
Taking out defective microprocessor control board from the AC unit and replaced it with new microprocessor of same make as provided by authorised service enginner or from manufacture service centre and fixing the new one , same making connection complete with satisfactory working all as required and directed by Engineer in charge.Make:- SOFTHARD or as approved by GE (I).
S&F in replacementof liquid line filter (Drier)of suitable size and suitable for 4x 21TR Cap AC plant complete all as specified and directed.
S&F in replacementof pressure release valve (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.
S&F in replacement of air release valve fitted in water chiller line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.
S&F in replacement of H.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.
S&F in replacement of L.P. (safety valve) fitted in refrigrant line and suitable for 4x 21TR Cap AC plant complete all as specified and directed.
S&F in replacement of 3 pole ,400 volt 50 Hz, 40 Amp contactor,of coil voltage 230 volt complete all as specified and directed.Make - Siemence or as approved by Engr-in -charge
S&F in replacement of worn out /unserviceable copper tubing from chiller to safety kit including making proper connection complete all as specified and directed.
S&F in replacement of clothing curtain fitted between AHU and main duct complete all as specified and directed.
S&F in replacement of worn out connector backelite, 440 volt, 145 amp suitable for 16 to 50 sq mm cable complete all as specified and directed.
S&F in replacement of digital meter to measure voltage and current of two compressor fitted at 4x21 TR AC Plant complete all as specified and directed. Make -SOFT HARD ,Model No. µ-M2 VPD-S or equivalent as approved by GE.
Disconnecting the electric connection from starter and motor including taking out of electric motor of capacity 2 HP from the existing position and strip opening, cutting the burnt out winding, cleaning the starter and re-winding the same with super enameled copper winding wire of same gauge using top class of insulating material & reassembling the same and re-fixing back in its original position complete all as specified and directed.
Taking out pump of 2 HP capacity and re-fixing the same in its original position after over hauling including lath/ machine work for making housing of bearing , metaling ,welding, turing surfacing ,polishing of rotor shaft, and replacement of neck ring , bearing of required size , bushes, rubber insertion sheet , nuts, bolts and washers including necessary other items for its smooth functioning and testing complete all as specified and directed.
S&F in replacement digital panel mounted AC Amp meter ( 0 to 500/600 Volt) , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .
S&F in replacement of worn out /unserviceable pressure gauge 100 mm dia of suitable range with all necessary tubing etc to make serviceable condition fitted in water chiller line complete all as specified.
Cleaning of cooling coil and air filter of Air Handling Units installed at air conditioning plant by removing air filters and fixing back after cleaning with air blower, water and cleaning agent, cleaning of cooling coil with wire brush and air blower and water spray pump after spraying scal Gun AL or equivalent chemical suitable for aluminium fins and straightening the fins of cooling coil using suitable brush cleaning of bottom tray, drain pipe complete one coat of painting with sinthetic enamal paint after rubbing of existing surface and applying one coat of primer inside and outside complete all as directed
Repair/Replacement of MCB, 63 mps, four pole and breaking capacitry 10 KA complete as directed. Make Legrand Cat Part No:- 402466 or ABB/ seimens.
Material and labour, rewinding of Exhaust fan three phase induction motor 1.5 KW/ 2HP 415 volt 940 rpm of any make of with suitable gauge of super enameled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearings, two coats of synthetic enamel spray painting, suitable main connections from coil to terminal box, opening of motor, cutting/removing old burnt winding coils, cleaning/filing the starter slots, necessary mechinical works for shaft/bearing housing, preparing and inserting coils running/starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and fro transportation, testing at site,replacing new connection terminal plate of following sizes satisfactorily running all as specified
Supply and installed commerical multiple scroll compressor suitable for 21 Ton capacity AC Plant on existing size Danfoss model no SZ185S4RC with refrigrent R407CR134a R404A R507A thermally protected system LP side PS 25 bar TS max 54 oC to -35 oC and HP side PS 31.9 bar TS max 65 oC to -35 oC complete with compressor oil including all connection complete all as directed. Make:- DENFOS Model No. SZ185S4RC or as approved by GE (I).
Supply, fixing, connecting and testing in replacement of worn out battery by sealed lead acid battery, 12 Volt DC, 150 AH duly charged including replacement of copper connection lead of suitable size with terminal clamps complete all as specified and directed. Make - Exide/SF /Amron or as approved by GE (I).
Supply and replacement of Automatic battery charger AC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp.Make:- Elak Pvt limited model AC 04
S&F in repair pressure die cast power coated LED street light 120 watt ,complete with LEDs , driver and accessories , pre wired up to terminal block in contol gear compartment complete with GI /MS Pipe bracket of suitable size and fixing arrangement and connection with suitable copper cable complete all as specified and directed, Make : Havells cat part No LHETAXU7PA J120 or equivalent of Wipro / Philips .
Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 40 mm dia GI pipe light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part - I 2007 including testing and test point complete. (GI strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately
Routine and periodical cleaning around the area of out door of Nano & Polymer bldg,GE(i) R&d office area, P29 transformer etc by cutting and removal/uprouting of unwanted grass/bushes, small trees including surface dressing and leveling by surface excavation wherever required complete in all respect or as directed.
M/s A S Electrical
keerti trading corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .