For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate Interlocking or AFTC or SSDAC or MSDAC.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure-V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: Extension of Up reception line (line No. 16) at Barakar Station Yard.
10-SDSTE-ASN-2026-27
10-SDSTE-ASN-2026-27
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹2.2 L
1 Jun 2026
6 May 2026
18 May 2026
156 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 36,05,600.4 | ||
| — | 1.00 | — | — | ||
| Supply of AC LED alpha or numeric route indicator for 1 19/A-R routes with complete housing with white LED as per specification IRS: S 66/84 Amdt.1 or latest and Drg. No. SA 23761(Adv.) or Latest. Lamp proving compatible with normal bulb type multi lamp route indicators. Input operating voltage 110V AC+/- 25%. Uniform intensity over entire operating range. Inspection: Consignee | — | — | — | 53,756 | |
| — | 2.00 | — | — | ||
| Supply of Stencil type route indicator 2 way as per RDSO Drg. No. SA-21281 and Spec. No. IRS-S-66/84 Amdt-1 or Latest. Inspection: Consignee | — | — | — | 26,866 | |
| — | 4.00 | — | — | ||
| Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete DRG. NO. SA- 23080/ADV/ALT-1. RDSO SPEC. NO. IRS-S-10/78. Inspection: consignee. | — | — | — | 10,052 | |
| — | 4.00 | — | — | ||
| Supply of position light shunt signal unit (without lenses, lamps) with Base Post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Inspection: Consignee. Note- Signal unit should be compatible to 'LED' type. | — | — | — | 27,128 | |
| — | 4.00 | — | — | ||
| Casting, concreting and curing of foundation for independent Shunt signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanized bolts & nuts with washers, cement, sand, stone chips, etc. As per DRG. NO SK/5/95/NKG. | — | — | — | 16,348 | |
| — | 4.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of independent shunt signal, LED unit as per technical specification and Eastern railway practice. | — | — | — | 2,008 | |
| — | 4.00 | — | — | ||
| Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post and as per standard practice. Inspection: consignee | — | — | — | 1,492 | |
| — | 15.00 | — | — | ||
| Supply of Shunt signal aspect LED signals , 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No. RDSO/SPN/153/2023 Revision: 5.0 or latest. Inspection: RDSO | — | — | — | 85,125 | |
| — | 7.00 | — | — | ||
| Supply of Electric Point machine IRS type 220 mm throw, high thrust (AC immunity 160V AC), non-trailable to operate on 110V, DC complete with Lock and Detector slides, Cable Termination Box and clamp lock confirming to IRS: S 24/2002 & Assy. Drg. No. RDSO-S/11000 & For Motor IRS: S 37/82. . Inspection: RDSO. | — | — | — | 9,18,155 | |
| — | 7.00 | — | — | ||
| Supply of GI bend pipe, 'B' class, 50mm dia. for cable entry in point machines, along with required fixing arrangements as per standard practice on Eastern Railway. Inspection: Consignee. | — | — | — | 18,291 | |
| — | 7.00 | — | — | ||
| Installation, wiring and testing of point machine. This includes Drilling of holes in stock/tongue rail, Gauge tie plates, M.S. Plate, installation of point machine on M.S. Plate fixed on sleepers insulating M.S.Plate from GTP and rearranging, refixing of existing electrical point detector if any. This work includes fixing of Point JB, Ground connections complete in all respect including smithy work, welding work. This also includes dismantling of existing point machine with its fittings if any and fixing of new point machine. This includes wiring and termination of cables/wires of point machine & point JB and necessary lettering. This also includes adjustment &testing as per technical specifications. M.S. plates, Nuts & bolts, Washers, spring washers, angle etc. of suitable size required for this purpose are to be supplied by the contractor. The work will be executed as per instruction of Rly. Site engineer. This work also includes dismantling of old point machine with ground connection and re installation of new point machine with ground connection, if required at site. Note: Point machine with ground connection, insulation materials & point JB, cable/wire will be supplied by Rly | — | — | — | 72,849 | |
| — | 7.00 | — | — | ||
| Shifting/re-locating/opening & refitting during Engineering work, fixing, wiring, testing of existing MSDAC DP as per direction of site engineer of Railway. This includes excavation of trenches for fixing of Tx/Rx cable, foundation etc. if required and re-erection of same DP. Note: 01 no. DP includes its Track device alongwith accessories. Any Rail connect/Track device accessories like nut & bolt, insulation etc. and damage during shifting has to be supplied by the contractor | — | — | — | 18,284 | |
| — | 1.00 | — | — | ||
| Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents for alteration work. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD), RFID plan/diagram. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways, then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation and supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75- micron polyester film for station in Auto CAD. 6 (Six) sets photo copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, | — | — | — | 58,797 | |
| — | 500.00 | — | — | ||
| Supply of 1 x 35 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 694:2010 or latest, 276 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn. No.IRS: S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO | — | — | — | 88,500 | |
| — | 1.00 | — | — | ||
| Supply of PVC insulated Railway Signalling multicore Indoor Cable 60 core (0.6mm dia) conforming to IRS:76/89(Amd3) or latest. Inspection: RDSO | — | — | — | 1,51,032 | |
| — | 100.00 | — | — | ||
| Supply of GI pipe with threaded collar of 100 mm nominal bore as per Specification No. IS:1239, medium grade, perforated of required length. Inspection : Consignee | — | — | — | 76,200 | |
| — | 100.00 | — | — | ||
| Laying, Fixing, installation of GI pipe with threaded collar of 100 mm nominal bore perforated of required length on bridge, below road/LXing/ track, on wall or at other site and laying of signalling cable/rod through it with supply of necessary materials as required for execution of this work. The work to be done as per instruction of Rly. site engineer. | — | — | — | 9,800 | |
| — | 250.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type. Inspection: Consignee | — | — | — | 1,69,750 | |
| — | 500.00 | — | — | ||
| Laying of half round RCC pipe after laying the cables in the trenches (cable laying is covered separately). | — | — | — | 11,000 | |
| — | 20.00 | — | — | ||
| Supply and fixing of RCC Cable Route Marker as per ER Drawing No. SI- S&T/1/2024(Sheet-1) and ER technical policy circular no. 108. Inspection of supply: Consignee. | — | — | — | 11,304.4 | |
| — | 5.00 | — | — | ||
| Supply of full size apparatus case(Large) (as per DRAWING NO.RDSO/S-11500. This includes supply of location box (GKP type)with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg .No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: Consignee | — | — | — | 69,580 | |
| — | 5.00 | — | — | ||
| Casting, concreting, curing and plastering of concrete foundation for full size location box (GKP type)with Cement, sand, Stone Chips in the ratio 1:3:6 and erection of full size apparatus case(location box) as per Drg. NO.S&T/C-6/98(NKG). All materials required for this purpose including holding down bolts, nuts, washer, concreting materials etc. are to be supplied by the contractor. Materials to be inspected by Rly. Site Engineer and the work will be executed as per instruction of Rly. site engineer. Note:-location boxes to be painted with anti corrosive paints ( Asian paint/Berger/Shalimar) as per IS:-9862- 1981, one and half feet from the bottom, on all surfaces-both inside and outside. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. | — | — | — | 17,660 | |
| — | 5.00 | — | — | ||
| Fixing of slotted angle, Bakelite strip, hylam sheet, fixing and wiring of terminals, relays, fuse with base etc. and fixing of shelves in Full size steel Apparatus cases(location box) with termination, dressing & bunching of cables/wires, earthling of cables and wiring with necessary lettering as required including supply of wires, slotted angles, ferrules for marking, misc. materials as required per location box. All materials except relay, terminal strips, bakelite strip, fuses with base, charger, D type resistance, B type choke, SSDAC equipment, surge arrester, battery and hardwood shelves to be supplied by the contractor. Wires to be procured from RDSO approved firm and to be inspected by RDSO. This includes sand filling and plastering over sand filling. NOTE: All locations to be provided with lamp/holder, switch for lighting as desired by Site Engineer. This should include all Terminations of Cable complete. Cable conductors are to be terminated with proper lugs and required bussbar and other terminals to be supplied by the contractor. | — | — | — | 24,150 | |
| — | 4.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size),fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 11,128 | |
| — | 200.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 Ver. 3.0 with latest amendment. The colour will be decided by Engineer - in -Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3).Inspection: RDSO | — | — | — | 11,000 | |
| — | 20.00 | — | — | ||
| Supply of end plate 2.5 mm / 0.91 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 200 | |
| — | 20.00 | — | — | ||
| Supply of end stopper 10mm/0.0394 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 200 | |
| — | 10.00 | — | — | ||
| Supply of steel Carrier Rails of size 35mm x 7.5mm, 1mm/0.039in thickness unslotted type for placing disconnect type terminals. .Inspection: Consignee | — | — | — | 1,090 | |
| — | 4.00 | — | — | ||
| Supply of Track feed Battery Charger having normally closed (NC) potential free contact for failure alarm as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO | — | — | — | 19,576 | |
| — | 12.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell of capacity 2V/ 80 AH, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO | — | — | — | 42,888 | |
| — | 5.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161- 66/M or latest. Inspection: RDSO | — | — | — | 855 | |
| — | 5.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn. No.IRS: S-65/83 (Amdt. 1) or latest. Inspection: RDSO. | — | — | — | 25,755 | |
| — | 10.00 | — | — | ||
| Supply & installation of 'C' class surge protection ( indication type)arrangement at feed end DC Track Ckt Specn no. As follows: - voltage 230 V AC rated voltage 350V AC DIS. CAP 10KA TO 20 KA TIME 100 MILI second protection 1.2V degree protection IP.20 TEC-61643-1. Inspection: by consignee. | — | — | — | 13,460 | |
| — | 10.00 | — | — | ||
| Supply & installation of polymer positive temperature coefficient device (PPTC) resettable fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHEM, BOURNS, LITTLE FUSE, FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs.". Inspection: Consignee. | — | — | — | 790 | |
| — | 20.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) made from FRP material including brass bolts and hylum board sheet with terminals etc. The technical specifications are as follows:(a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertically two for each FRP angle) HDPE pipe , cable etc.(b) Each TLJB shall have two Bakelite terminal block fitted horizontally : each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied.(c) HDPE pipe of size 32/35mm , 380 mm long along with two nuts for fixing on the TLJB hole .(d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanized nuts and bolts. The TLJB and the angles for stump should come along with holes on them for fixing using galvanized nuts and bolts of adequate strength to be supplied along with TLJB. Inspection: Consignee | — | — | — | 71,280 | |
| — | 4.00 | — | — | ||
| Installation, wiring, testing & commissioning of track circuit involving points & crossings as per track circuiting plan, track battery charging and installation including drilling 9/32" hole on rails; fixing of bonding(double) with 8 SWG soft GI wire, insulation of stretcher bars (leading & following), gauge / crossing tie plates involving cutting and riveting/welding of angle clit, split stretcher bars, fixing of track lead junction box, rail connector with GI wire, track jumpering (double) with supporting arrangement for holding termination of track lead wires, including series jumpers, jumper wire terminals, track feed set(track chargers, resistance, fuses, battery etc.) As per approved IYD for point zone track circuit. Note: - battery charging solution to be supplied by the | — | — | — | 13,392 | |
| — | 5.00 | — | — | ||
| Supply of hard wood shelves of size 950 x 400 x 25 MM for full size location box. for keeping equipment's and batteries in the full size location box with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee | — | — | — | 2,815 | |
| — | 4.00 | — | — | ||
| Supply of Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:939A & 966(Appendix F2) and RDSO Spec No. IRS:S-34 & S-23 with latest amdt. The interlocking code for this unit shall be "FGHKX". Inspection authority: - RDSO | — | — | — | 15,260 | |
| — | 10.00 | — | — | ||
| Supply of Earth Electrodes mild steel galvanized , light class , as per Specification No. IS:1239(Part-I)-1979 and as per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.25. Earth electrode pipe should be 3 mm thick, 50 mm dia. and perforated ( staggered) with 5 mm dia holes 2 nos. per 305 mm length alongwith supply of CI threaded cap, nuts, bolts, other materials as mentioned in Drg. No. SI/TYP/0097 . Earth electrode pipe to be galvanised after drilling and fabrication. Inspection: Consignee. | — | — | — | 14,960 | |
| — | 10.00 | — | — | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends Inspection :consig | — | — | — | 9,110 | |
| — | 10.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or cable for apparatus cases, signal post & other equipment as per guideline mentioned in PCSTE/ER'S DRG. NO. SI/TYP/0097 with provision of alternate layers of charcoal /coal and salt . Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. As per requirement MS flat may be joined by welding to increase length or to be cut & drill hole to shorten the length. All hardware and other miscellaneous materials required for installation to be supplied by the contractor | — | — | — | 11,610 | |
| — | 10.00 | — | — | ||
| Provision of cement concrete enclosure of size 450 mm x 450 mm x 300 mm and 75 mm thick for earth electrodes as per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.25. This includes supply of all materials by the contractor duly inspected by consignee. | — | — | — | 5,710 | |
| — | 5.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn. No. IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO | — | — | — | 38,345 | |
| — | 200.00 | — | — | ||
| Supply of 6 WAY PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST and DRG.NO.23756, ALT-3 or latest. Inspection: RDSO. | — | — | — | 97,000 | |
| — | 10.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee | — | — | — | 53,700 | |
| — | 100.00 | — | — | ||
| Supply of non-deteriorating(2A/6A/10A/16A) type, cylindrical (IRS-S-78/92) [quantity on basis of fuse rating will be fixed by Rly. Engineer before supply].Inspection: RDSO | — | — | — | 6,100 | |
| — | 10.00 | — | — | ||
| Supply of fuse block (PBT) to spec.no.IRS-S- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 23748 with fuse inserts cartridge, non-deteriorating type to spec.IRS-S-78/92 with latest amendment. Inspection: -RDSO. | — | — | — | 1,780 | |
| — | 10.00 | — | — | ||
| Cement concrete work for miscellaneous items/purpose in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm. Aggregate, cement & sand etc. to be supplied by the contractor for this work | — | — | — | 35,960 | |
| — | 2.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right-hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | — | — | 25,772 | |
| — | 8.00 | — | — | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | — | — | 23,216 | |
| — | 2.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain or similar of reputed company. Inspection Consignee | — | — | — | 34,326 | |
| — | 8.00 | — | — | ||
| Supply of Professional AC/DC clamp meter 3 ¾ digit, true RMS measurement, For Measurement of DC/AC currents up to 1000A, Voltage up to 600V, resistance up to 40 M and frequency up to 1 MHz with set of leads & carrying case. Model - DCM 39A or equivalent/ higher make Fluke. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 2,30,016 | |
| — | 5.00 | — | — | ||
| Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 - 49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement Model - DECT-2 or equivalent / higher version make Fluke. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 4,74,800 | |
| — | 4.00 | — | — | ||
| Supply of Insulation tester 100V, 100 M.Ohm with lead cables, Analog Display, metal body & hand driven. Make: Waco/Nippen/Fluke/Motwane or similar reputed company. Inspection: Consignee | — | — | — | 12,080 | |
| — | 8.00 | — | — | ||
| Supply of Digital Multimeter of Fluke 287 Industrial or Similar/ superior True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 3,52,512 | |
| — | 7.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | — | — | 74,02,462.25 | ||
| — | 7.00 | — | — | ||
| Supply of Point JB made of FRP material ( FRP material specification RDSO/SPN/151/1997 or latest) fitted with 18 nos. 1-way terminal block confirming to IRS-S-75/2006 or latest, DRG. NO. SA-23741A with 3 no. of 40 mm bore G I PIPE 600 mm long and 02 FRP angles of size 40x40x6 mm pultruded with provision for fixing of angles as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources. Inspection-Consignee. | — | — | — | 61,528.74 | |
| — | 20.00 | — | — | ||
| Supply of RFID tags as per RDSO/SPN/196/2020 version 4.0 or latest. inspection: RDSO. | — | — | — | 1,73,682.8 | |
| — | 20.00 | — | — | ||
| Installation, programming, verification and commissioning of RFID tags at stations and block sections | — | — | — | 61,942.4 | |
| — | 20.00 | — | — | ||
| Supply of underground, unscreened, PVC insulated, PVC inner sheathed armoured and PVC outer jacket railway signalling cable with high conductivity copper conductor of size 12 core x 1.5 sq mm as per Specn. No. IRS:S-63/2014( Rev.4.0) or latest. Inspection : RDSO | — | — | — | 53,09,952.8 | |
| — | 1.00 | — | — | ||
| Supply of Underground Railway Jelly filled Telecom 6- Quad Cable(0.9 mm Dia) for Signalling And Telecom. Installation, as per Spec. No. IRS:TC-30/2005 (Ver.-1) (Amd. 5) or latest. Inspection: RDSO. | — | — | — | 3,12,936 | |
| — | 4.00 | — | — | ||
| Excavation of trench as per cable route plan in all kinds of soil (1.2 mtr. Depth and 0.3 mtr. to 0.6 mtr width at bottom) and refilling of the trench without bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. Note:- Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in a span of 100 M or shorter lengths if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment. Prior permission should be taken from field Officer before laying of cable if the depth of trenching is less than 1.2 mtr. and duly mentioning location, length etc. in site register. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. For all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. | — | — | — | 5,33,117.64 | |
| — | 21.00 | — | — | ||
| Laying of S&T cable of various core sizes as per cable route and cable core plan approved by Railway and meggering of all main & Tail cables. The work to be done as per instruction of Rly. site engineer. Note: All materials (except cable) required for the execution of the work shall be supplied by the contractor. | — | — | — | 1,86,689.37 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
TenderDocument_SnT1.pdf
ATTACHMENT
GCC Correction Slip
ATTACHMENT
GCC Correction Slip 2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf GCC Correction Slip 3456
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
AllAnnexure.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
Spec_search_light.pdf
ATTACHMENT
Cable_cut_HQ_JPO_94.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .