Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | ₹3.2 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹3.4 Cr+₹23.4 L (7.41%)Rejected-Finance | ₹3.4 Cr+₹23.4 L (7.41%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.4 Cr+₹28.0 L (8.84%)Rejected-Finance 00 BARGO BARGO SENDULI BENDULI GORAKHPUR UTTAR PRADESH 273016 | GORAKHPUR | UTTAR PRADESH | 273016 | ₹3.4 Cr+₹28.0 L (8.84%) | L3 | Rejected-Finance L3 |
Tender Value
₹3.6 Cr
Closing Date
20 Oct 2021, 3:00 pmClosed
Chairman GB
3rd floor VS Bhavan
Building work including PH work / PH work
2021_DCSEM_650124_1
DCSEM/CQD/QSB/21-22/NIT/55 dated 24.09.2021
Open Tender
Civil Works - Buildings
Item Rate
365 days
Anushaktinagar
please refer tender documents
5 documents required · 5 mandatory
₹0
Exempted
15 Dec 2022
28 Sept 2021
21 Oct 2021
28 Sept 2021
20 Oct 2021
28 Sept 2021
28 Sept 2021 - 8 Oct 2021
Amount
GENERAL ABSTRACT
PART-A- UPGRADATION OF PH SERVICE LINES
PART-B-REBATE ITEMS
Description of Work / Item(s)
Amount
PART- A-(Upgradation of PH-Service-lines)
Supplying & fixing on Exposed surfaces thefollowing sizes uv-stabilized Chlorinated Poly Vinyl Chloride ( CPVC ) pipes & Fittings or ASTM pipes & fittings of specified class having thermal stability for both hot & cold water supply consisting following items of work:- i) Supplying CPVC pipes and CPVC plain / brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply conforming to IS 15778 or ASTM pipes & fittings with ISI mark / equivalent approvals as per relevant standards. ii) Laying and fixing the pipe and specials on exposed surfaces / underground, to correct line, level and plumb for water supply line, using metal straps ( On wall surfaces ) at 1.00mtr. interval or as directed by the EIC. iii) Jointing the pipes and Specials using Solvent cement conforming to IS 15225 & Teflon tape ( For threaded joints) of approved makes including cutting the pipe to required size, preperation of surfaces, necessary tools etc. all complete. iv) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. v) Testing the pipe line to a hydraulic pressure as per manufacturers cataglouge for leak proof joint or as per relavant code Pipes & Fittings SDR-11(Upto 50mmdia) as per IS 15778
15 mm n.size
20 mm n.size
25 mm n.size
32 mm n.size
40 mm n.size
50 mm n.size
63 mm n.size (as per Sch-80)
80 mm n.size (as per Sch-80)
15 mm n.size
20 mm n.size
25 mm n.size
Providing & fixing CPVC Ball Valves of' SUPREME' make suitable for hot & cold water conforming to the pipe pressure class, making water proof joints, including the costof jointing material and CPVC specials if required & testing the joints along with the pipe line etc. complete as per directions of engineer-in-charge.
Supplying & fixing following size C.P brassCoupling with approved quality C.P brass Mosquito proof jalli including providing cPVC specials, if required for fixing the coupling, jointing materials such as teflon tape etc. complete as specified & directed fo roverflow / vent pipe of water tank.
65 mm dia
50 mm dia
20 mm dia.
Providing, instaling, fixing, connecting, testing 74 micron Super Flow - Screen filter, of M/s.Jain Irrigation Systems Ltd., of following Model Nos, fitted with pressure gauge, waterdrain and emptying plug etc all as pe rspecifications, drawings and as directed by Engineer in Charge
For 80 mm dia cPVC pipe DJPSF12, Max. working pressure = 10 kg/cm², Flow rate = 25 m³/hr, Inlet/Outlet Connection = 50 mm
For 65mm dia cPVCpipe DJPSFP25SW, Max. working pressure = 10 kg/cm², Flow rate = 40 m³/hr, Inlet/Outlet Connection = 2.5"
Supplying, fabricating and fixing in position GI structural steel of angle, joists, channel, IBeam, plain / chequered plates for monorail /MS gates / supports of required size including cutting, fabricating, welding, erecting inposition including supplying & fixing embedded parts for fixing monorail /supports in concrete, including painting with two coats of approved synthetic enamel paint over a coat of zinc cromate red oxide primer all complete all as per specification and as directed by the Engineer in Charge
Using angle, sloted angles, Joists/ 'I' beam,Channel Extruded Hollow sections such as SHS, RHS etc.
Supplying & fixing following Stainless Steel (grade 304L) spool pieces of required diameter having flange on one / both sides (Table E) with flange hole, 450 mm or standard available length, providing 3D x 3D and 4 mm thick stainless steel puddle plate (minimum150mm x 150mm) welded to it where D is the outer diameter of pipe including cutting the plate to required shape and fixing in the reinforcement at the center of RCC wall / slab including cutting the form work provided for concrete at required level, height etc. Complete all as per specification and as directed by the Engineer in Charge
20 mm to 300 mm dia.
Providing & fixing stainless steel pipe handrail at main staircase & lobby, all floors &levels conforming to 304 grade of steel, ofschedule 10-S, having 300mm heightapproximately, pattern is 38mm dia.NB Pipein horizantal, 16mm dia. NB pipe in verticalall as per pattern & design in drawing including necessary S.S bend, tees, welding /nut-bolt necessary anchoring polishing andfixing in concrete/brick wall with S.S lugs,making pockets, concreting, making good thesurfaces etc. as per specifications drawingsand as directed by Engineer in Charge.
Providing GRP/FRP composite Mosquitoproof hinged cover with frame (Havingloading capacity not less than 500 Kg) of'EVERLAST' having suitable lockingarrangement for Manhole opening of watertank, fixing the cover by providing corrosionresistant studs, nuts, built-in hold fasts etc. bychasing or cutting holes and grouting withcement mortar 1:1 by adding approved waterproofing compound @ 2% by weight ofcement, all complete as per specification andas directed by Eingineer in Charge
530 mm dia.
Making flanged joints for GI/ PPR/ PVC/UPVC/ CPVC / HDPE pipes and specialsincluding providing following dia. GI/ PPR/PVC/ UPVC/ CPVC/ HDPE heavy qualityflanges with holes drilled to IS standard,making flanged joints including all jointingmalerial like appropriate collar / neck piece,SBR Gasket, M.S. bolts & nuts of suitable sizeetc complele, including testing jointshydraulically to a pressure & duration asspecified alongwith the pipeline andrectification of leaky joints if any, and makingconnection with existing /new pipeline work,all as per specifications and as directed by theEngineer-In-Charge.
40 mm dia and above upto 110mm dia with providing Double new flange of DI/GI/MS
40 mm dia and above upto 110mm dia
Supplying and fixing following size uPVCUV-Stabilised soil / waste quality pipes andfittings ( SWR ) for soil, waste, vent,antisyphonege, HVAC waste pipe and rainwater pipe lines consisting following items ofwork:- i) Providing and fixing uPVC UV-StabilisedSoil / waste pipe as per IS:13592 and IS:14735Grade-B laid in floor & on Exposed faces ofwall of Supreme make ii) Fixing the pipeline vertically by Metalclamps with rubber seal of Supreme make Cat.No. SWRMCR 1 to 6. iii) Providing and fixing uPVC cowl at the topof soil, waste water & vent pipe line .iv) Laying the pipe below floor / ground toproper slope and gradient for makingconnections of soil / waste water pipe linewith inspection chamber or Manhole,including the cost of cement mortar, cementconcrete, water proofing compound etc. v) Jointing the pipe with Solvent Cement &Rubber ring gasket with making holes in walls/ floor grooving and redoing the same andbrick support etc. Giving water-tightness testfor the pipes laid as per codal provisions.Providing Ring Joint pipes at verticals andsolvent cement jointed pipes at consealedlocations. vi) Necessary cutting to the required lengthincluding short pieces, fittings with & withoutdoor, assorted fittings such as plugs, tees,couplers, reducers, cross tees, reducing tees,elbows, bends, cleaning pipe, single & doubleY, vent cowl, gaskets, offsets, Tank / WCconnectors etc. For Soil & waste and Vent pipe lines
50 mm dia.
75 mm dia.
110 mm dia.
160 mm dia.
Providing uPVC Floor Trap / Nahani Trap offollowing size having not less than 40 mmeffective water seal, fixing the trap in positionand connecting with waste water pipe bycement solvent / as per manufacturer'srecommandation, embedding the trap incement concrete 1:2:4 to correct level andgradient, providing and fixing 200 x 200 mmsize top tile with central strainer & flat cover /flush strainer, closing the side inletes withplugs if required etc. all complete as perspecification and as directed by EIC.
Multifloor trap of 110 x 75 x 50 size of Suprememake Cat No. NSPHMTS04L / NSPHMT005Land 3 pc top tile & flush strainer, mat finish ofSupreme make Cat No.NSPHTT201L/NSPHTT200L.
Providing uPVC cleanouts of following sizesand fixing along the uPVC Waste / soil pipelines laid below the floor for inspection /choke removal including the cost of jointingmaterials.
Providing HDPE sheet flashing fabricated bywelding HDPE flexibal sheet with 160 / 110mm dia HDPE pipe about 400mm long forPVC rain water pipes, fixing with cementmortar 1:2 mixed with water proofingcompound and forming the proper shape andgrade and compound and forming the propershape and grade and finishing with inletmouth of rain water pipe, cutting RCC slab orwall if required,including the cost of bitumen,cement mortar etc. all complete as specifiedand as directed by the Engineer-in-charge.
450 x 450 mm size HDPE sheet Flashing fabricated from 8mm HDPE sheet and PN 6 grade 160 mm dia HDPE pipe
Providing and fixing Stainless steel Domemesh fabricated by welding from 2mm dia 304L grade stainless steel wire for PVC rain water pipes (sheet flashings), with 5mm x10mm L base ring of 0.5mm thickness 304L grade Stainless steel. L ring to be embaded in waterproofing & dom to be placed on it, including the cost of fixing material etc. all complete as specified and as directed by the E.I.C.
Half Spherical Dome having opening 5 to 10 mm of 160 mm ID
Providing uPVC Gully Trap of 150 X 100 mmsize with 100 mm outlet with Grating ofapproved Make, placing at correct position,embedding in cement concrete 1:2:4, 100 mmthick alround complete.
Constructing brick masonry Gully Trapchamber of following size and upto 600 mminitial depth including providing and fixinggully trap, consisting following items of work:-i) Providing square mouth uPVC gully trap ofsize 150 X 150 mm with 110 mm outlet ofApproved Make embedding in position incement concrete 1:2:4 inside the chamber.ii) 230 mm thick brick masonry in 1:4 cementmortar over 150 mm thick cement concrete1:2:4.iii) 15 mm thick plaster in cement mortar 1:3 oninternal and external surfaces, internal surfacesand top finished with a floating coat of neatcement.iv) Providing and fixing precast EVERLASTComposite (FRP/GRP) Manhole covers &frame of size 300mm x 300mm as approved byE.I.C having point loading capacity not lessthan 0.3 tonne approved, including cost ofnecessary hardware and cement concrete /mortar for fixing the frame.
Construction of 300 X 300 mm size Gully Trap chamber including Providing & fixing Gully Trap with frame & cover all complete.
50 mm dia.75 mm dia.110 mm dia.160 mm dia.Providing uPVC Floor Trap / Nahani Trap offollowing size having not less than 40 mmeffective water seal, fixing the trap in positionand connecting with waste water pipe bycement solvent / as per manufacturer'srecommandation, embedding the trap incement concrete 1:2:4 to correct level andgradient, providing and fixing 200 x 200 mmsize top tile with central strainer & flat cover /flush strainer, closing the side inletes withplugs if required etc. all complete as perspecification and as directed by EIC.Multifloor trap of 110 x 75 x 50 size of Suprememake Cat No. NSPHMTS04L / NSPHMT005Land 3 pc top tile & flush strainer, mat finish ofSupreme make Cat No.NSPHTT201L/NSPHTT200L.Providing uPVC cleanouts of following sizesand fixing along the uPVC Waste / soil pipelines laid below the floor for inspection /choke removal including the cost of jointingmaterials.110 mm75 mmProviding HDPE sheet flashing fabricated bywelding HDPE flexibal sheet with 160 / 110mm dia HDPE pipe about 400mm long forPVC rain water pipes, fixing with cementmortar 1:2 mixed with water proofingcompound and forming the proper shape andgrade and compound and forming the propershape and grade and finishing with inletmouth of rain water pipe, cutting RCC slab orwall if required,including the cost of bitumen,cement mortar etc. all complete as specifiedand as directed by the Engineer-in-charge.450 x 450 mm size HDPE sheet Flashing fabricated from 8mm HDPE sheet and PN 6 grade 160 mm dia HDPE pipeProviding and fixing Stainless steel Domemesh fabricated by welding from 2mm dia 304L grade stainless steel wire for PVC rain water pipes (sheet flashings), with 5mm x10mm L base ring of 0.5mm thickness 304L grade Stainless steel. L ring to be embaded in waterproofing & dom to be placed on it, including the cost of fixing material etc. all complete as specified and as directed by the E.I.C.Half Spherical Dome having opening 5 to 10 mm of 160 mm IDProviding uPVC Gully Trap of 150 X 100 mmsize with 100 mm outlet with Grating ofapproved Make, placing at correct position,embedding in cement concrete 1:2:4, 100 mmthick alround complete.Constructing brick masonry Gully Trapchamber of following size and upto 600 mminitial depth including providing and fixinggully trap, consisting following items of work:-i) Providing square mouth uPVC gully trap ofsize 150 X 150 mm with 110 mm outlet ofApproved Make embedding in position incement concrete 1:2:4 inside the chamber.ii) 230 mm thick brick masonry in 1:4 cementmortar over 150 mm thick cement concrete1:2:4.iii) 15 mm thick plaster in cement mortar 1:3 oninternal and external surfaces, internal surfacesand top finished with a floating coat of neatcement.iv) Providing and fixing precast EVERLASTComposite (FRP/GRP) Manhole covers &frame of size 300mm x 300mm as approved byE.I.C having point loading capacity not lessthan 0.3 tonne approved, including cost ofnecessary hardware and cement concrete /mortar for fixing the frame.Construction of 300 X 300 mm size Gully Trap chamber including Providing & fixing Gully Trap with frame & cover all complete.Construction of 300 X 300 mm size Gully Trap chamber including Providing & fixing Gully Trap with frame & cover all complete.
110 mm DN (SN 8kN/m²-SDR34)
160 mm DN (SN 8kN/m²-SDR34)
Constructing brick masonry Inspectionchambers of internal sizes 900 X 600mm atbottom and 900 X 450mm at top for an initialdepth of 600mm consisting following items ofwork. i) 230 mm thick brick masonry in cementmortar 1:2 over 150 mm thick bed in cementconcrete of grade 1:2:4 with 150 mm offsetalround, tapering the longitudinal walls to aheight of 450 mm from top of chamber cover toobtain an internal dimension of 900 X 450mmii) 20 mm thick plaster in cement mortar 1:1mixed with water proofing compound @ 2%by weight of cement on internal and externalsurfaces, internal surfaces and top finishedwith a floating coat of neat iii) Making benching and haunching in cementconcreteof grade 1:2:4 and finishing withfloating coat of neat cement.iv) Fixing frame and cover at top using cementconcrete of grade 1:2:4 (for bed block / bearingcourse and capping) and cast iron steps / footrests, all as per specification and as directed by E-in-C. Making ramp, connecting incoming &outgoing sewers & U-channel (Upto initialdepth of 600 mm between the inverts ofincoming & outgoing sewers) of height andwidth not less than the branch pipe dia. in CC1:2:4, plastering 20 mm thick in CM 1:3,finished smooth with a floating coat of neatcement all complete. NOTE:- Providing &fixing foot-rests / steps and CI / RCC /Composite frame & cover, CC of grade 1:2:4,plastering in C.M 1:2 on exposed surfaces ofbed block & capping,making smooth cementfinish etc. will be paid under relevant item.
Inspection chamber of internal sizes 900 mm X 600 mm at bottom and 900 mm X 450 mm at top for an initial depth of 600mm.
Extra over above item for depth beyond 600 mm initial depth & upto a depth of 1800 mm. all as per specification and as directed.
Providing & fixing GRP/FRP Compositeframe with Covers / Gratings of M/s Everlastor approved make, tested for load designationas per IS:1726 including the cost of 1:2:4 gradeconcrete for fixing frame, bed block (bearingcourse) and capping including necessary formwork and C.M 1:2 mortar for fixing the frame &for plastering exposed surfaces of concretebed block and capping finished smooth withfloating coat of neat cement etc., complete asper specifications, drawings and as directed bythe E.I.C.
Circular Heavy duty (Grade HD-20 load Designation as per IS:1726) frame and cover clear internal dia. 530mm
Square Heavy duty (Grade HD - 20 load designation as per IS:1726) frame and cover suitable for 300 x 300mm (Clear) valve chambers/Gully trap chambers/drop cleaningchambers etc.
Cement concrete of specified grades at all locations & depths for the following works using graded stone aggregate of 20mm. maximum size including necessary form work, machine mixing, transporting, placing in position consolidation, finishing, curing etc. complete as per specifications, drawings & as directed by the EIC.
PCC 1:2:4 in bed concrete, pedestal, encasing etc.
Providing, Casting and fixing concrete blocks of PCC 1:1.5:3 Mix concrete to support water supply lines including shuttering etc. Complete all as per specification and drawing and as directed by Engineer- in- Charge.
Supplying, fabricating and fixing in position at all floors factory made Aluminium sliding/top hung/fixed/ adjustable louvered windows & ventilators with rivet joint of specified size, made of integrated bronze anodised matt finished (15micron thick) aluminium section (extruded) , including for making exhaust fan frame work, handles of specified size etc, of approved manufactures for following types with extruded sections of Jindal / Indal / Aluminax or other approved equivalent make of approved sections with size and weights as directed for frames and shutters(including wastages if any) confirming to relevant IS specifications with all approved Bronze anodised aluminium fittings and accessories, latching fixture, 2/3 rollers with ball bearing of superior quality all as shown in the drawing including providing and fixing aluminium channel beading/glazing clips fixed with necessary bronze anodised screws, grouting the gap with sealant and including dismantling of existing window frame and shutter, glass and depositing same to dept store etc all complete generally as per drawing, specifications etc, all as directed by EIC. Note: Plate handle of 150 mm long & 6 mm thick will be considered for payment, nothing extra will be paid for other fittings & fixtures
18 mm thick machine cut and single side machine polished Baroda green marble stone for window cill in stepped form laid over 20 mm thick 1:4 cement mortar & overlapping of 20 mm shall be fixed with Araldite adhesive with best workmanship, including half round moulding & polishing of exposed face etc complete.
Upto a depth of 1.5 M. from ground level.
Brick masonry at all heights using well burntBricks from approved lots of class designation35 classification as per IS 1077-1992 and min.average compressive strngth not less than 3.50N/sq.mm ) using CM 1:6 in 230 mm walls tocorrect line, level & plumb including rakingout joints, curing, scaffolding etc. complete asper specifications, drawings and as directed byEIC for pipe supports, pedestals etc. in cementmortar 1:6 for pipe support
Providing 15 mm thick internal plasteringusing Ready mix internal plastering in CM 1:4or as per approved manufacturersspecification of approved make for pedestalspipe supports, brick walls, stone masonry,concrete surfaces etc. with floating coat of neatcement, including preparation of the surface,curing, cleaning, scaffolding complete all asper specifications and as directed at site by theEngineer-in-charge
Supplying & fixing 10 mm thick PVC integral free foam sheet in form of flush finish door shutter, manufactured by M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet) or other equivalent approved make of approved colour, solid section, extruded rigid, light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides, all edges to be smooth finish with mixture of PVC powder & solvent etc complete all as per specification and as directed by the EIC.
Providing and making cores of 65 mm / 50 mm dia. to the overhead water tank using electric operated core cutting machine and plugging of old damaged/ abandoned pipes holes with waterproofing cement mortar all complete as directed by Engineer-In-Charge.
Providng and fixing of 65 mm/ 50 mm dia pipe sleeves upto 450 mm length and making outer surface rough for scour/ outlet pipe with plug and fixing it to core made at the directed place by using polymer mortar and making the core waterproof etc. complete all as directed by the Engineer-In-Charge.
Providing following size class-I Peet / GateValve of brass or Gun metal, with Cast ironwheel, conforming to IS 778 upto 300 mmsize, fixing the Valve to pipe line includingthe cost of jointing materials, testing for leakproof joints at 10 kg / sq.cm hydraulicpressure, all complete as per specificationand as directed by EIC.
20 mm dia.
25 mm dia.
32 mm dia.
40 mm dia.
50 mm dia.
65 mm dia.
80 mm dia.
Supplying & fixing on Exposed surfaces thefollowing dia. Galvanised iron pipe ofspecified class consisting following items ofwork:- i) Supplying galvanised mild steel screwedand socketed pipe conforming to IS 1239 (part-I ) with galvanised mild steel or wroughtsteel fittings conforming to IS 1239 ( part-II) ii) Laying and fixing the pipe and specials onexposed surfaces to correct line, level andplumb for water supply line, overflow andvent using M.S. nails, rawl plugs, woodengutties and 'U' type G.I clamps having not lessthan 2 mm thick. iii) Making leak proof threaded joints usingWhite zinc, Spun yarn etc. including cuttingthe pipe, threading and the cost of jointingmaterials. iv) Cutting or making hole or chases in RCCor brick work structure such as wall, column,beam, slab, chajja, dado etc. for passing thepipe line and reinstating all the damage to itsoriginal condition. v) Testing the pipe line to a hydraulic pressure of 10 Kg / Sq.cm for leak proof joint. vi) Painting the pipe line after testing with two coats of flat oil paint of approved make and shade over a coat of approved primer. Class " C " ( Heavy quality ) G.I. pipe & fittings.
Supplying and laying below the ground orfloor, the following diameter galvanised ironpipe line of specified class, consisting thefollowing items of work:-i) Supplying galvanised mild steel screwedand socketed pipe conforming to IS 1239 (part-I ) with galvanised mild steel or wroughtsteel fittings conforming to IS 1239 ( part-II).ii) Laying pipes and specials below theground or floor for water supply / Waste linein proper level and gradient.iii) Making leak proof threaded joints usingWhite zinc, Spun yarn etc. including cuttingthe pipe, threading, the cost of jointingmaterials etc.iv) Testing the pipe line to a hydraulicpressure of 10 kg / sq.cm for leak proof joints.v) Providing & wrapping 'Pypekote' (corrossion protected tape ) of 4 mm thickincluding supplying & application of pipecoating and spiral wrapping etc. ( wrappingshould have an overlap of 15 to 20 mm )complete as per standards for corrosionprotection of pipes that are laid underground/ floor. Class " C " ( Heavy quality ) G.I. pipes & fittings.
Description of Work / Item(s)
Amount
PART- B- REBATE ITEMS
Rebate for taking away dismanteled item by the contractor……
a) GI Pipes of various dia
b) CI pipe of various dia
c) GM gate valves of various dia
d) wooden batterns
GI pipe scrap
MARUTI ENTERPRISES
ANS Constructions.com
MARUTI ENTERPRISES
ANS Constructions.com
Renjin Construction
ANS Constructions.com
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .