GARRISON ENGINEER
GE (SOUTH) UDHAMPUR
REPAIR TO JOINERY ROOF FLOORING PLASTERING SANITARY FITTINGS AND ALLIED SERVICES AT CERTAIN MD/OTM ACCN AREA OF DEPOT AND OTHERS UNDER AGE BR I GE SOUTH UDHAMPUR
2022_MES_499608_1
GE/S(U)-70/2021-22
Open Tender
Civil Works
Works
330 days
GE (SOUTH) UDHAMPUR
As per Tender documents
9 documents required · 9 mandatory
₹500
GE (SOUTH) UDHAMPUR
₹70,000
19 Mar 2022
5 Jan 2022
3 Feb 2022
5 Jan 2022
2 Feb 2022
19 Jan 2022
5 Jan 2022 - 15 Jan 2022
Amount
Demolition of cement concrete in ground floor and pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed.
Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor), beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed.
Dismantling asbestos corrugated or semi corrugated sheets as in roof covering including ridge etc complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members complete all as specified and directed.
Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise specified complete all as specified and directed.
Demolition of and breaking up of AC rain water pipes any dia fixed in any position complete all as specified and directed.
Taking up or down steel tubing 15 mm bore including cleaning for refixing or removal to store complete all as specified and directed.
All as per ser item No 9 above but 20 mm Bore complete all as specified and directed.
Dismantling water tank of capacity exceeding 250 ltrs but not exceeding 500 ltrs complete all as specified and directed.
All as per ser item No 11 above but exceeding 500 ltrs but not exceeding 1000 ltrs complete all as specified and directed.
Brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 bricks complete all as specified and directed.
All as per ser item No 13 above but except bricks complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed.
Random rubble masonry built in cement mortar 1:6, uncoursed, well bonded, bedded and solidly hearted complete all as specified and directed.
All as per ser item No 16 above but except stones complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channel and drain beds including all necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channels cement concrete using extra cement including forms, mould, mitred/ stopped ends etc. complete all as specified and directed.
Rendering 15 mm thick in two layer (10 + 5 mm) on brick work or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed. (Water proofing compound to be measured and paid for separately).
10 mm thick rendering on fair faces of brick works in cement mortar 1:6 finished even and smooth without using extra cement in cement mortar complete all as specified and directed.
05 mm thick rendering on fair faces of concrete such as chajjas/ceiling finished even and smooth without using extra cement in cement mortar 1:3 complete all as specified and directed. Note : Rate quoted by contractor deemed to be included for plastering chajjas to up to height of 10 mtrs.
PCC 75 mm thick 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection laid in alternate pannels finished even and smooth without using extra cement complete all as specified and directed.
75 thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in sub base for laying floor finishes complete all as specified and directed.
15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
10 mm thick rendering on fair faces of brick work in cement mortar 1:4 finished rough for receiving tiles as in dado complete all as specified and directed.
7 mm to 8 mm thick non skid coloured ceramic tiles in floor (area of each tile exceeding 0.11 and not exceeding 0.18 sqm) etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments complete all as specified and directed.
All as per ser item No 29 above but in vertical surfaces complete all as specified and directed.
Coloured double charged Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of existing surfaces. complete all as specified and directed. Note : The contractor shall have no claim on difference what so ever on shade/colour of tile.
Coloured double charged Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.42sqm but not exceeding 1.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of existing surfaces complete all as specified and directed. Note : The contractor shall have no claim on difference what so ever on shade/colour of tile.
All as per ser item No 31 above but in vertical surfaces complete all as specified and directed.
Coloured durastone heavy duty vitrified tiles 10 mm thick Sq/rectangular tiles area of each tile not exceeding 0.36 Sqm as in floors set and jointed in neat cement slurry and pointed in clooured cement to match the surface complete all as specified and directed. Note : The contractor shall have no claim on difference what so ever on shade /colour of tile.
All as per ser item No 34 above but in vertical surfaces complete all as specified and directed.
Cement concrete rich coloured chequered tiles machine pressed with imported pigment smooth finish of size (300 mm x 300 mm or any size as approved 20 to 25 mm) thick set and jointed with neat cement slurry complete all as specified and directed.
15 mm to 18 mm thick granite stone slab as in shelves/vertical surfaces/platforms set and jointed in neat cement slurry, pointed in colored cement to match the shade including rubbing of moulding etc, complete all as specified and directed.
(300 mm x 600 mm x 7 mm/300 mm x 450 mm x 7 mm or 8 mm thick) coloured glazed ceramic tiles set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments in vertical surfaces complete all as specified and directed. Note : Contractor shall have no claim on colour or shade what so ever on this account.
Sand cushioning under floors including watering and consolidation complete all as specified and directed.
Coloured machine pressed/vibro mechanically floated interlocking paver block any shape and size confirming to IS - 15658-2006 of 60 mm thickness, M-35 grade, with topping of cement mixed with imported pigment colour and shape shall be approved and complete all as specified and directed by Engr-in-Charge. Make : ULTRA/ MODERN/RUCHI/ISI Marked.
Machine pressed (factory made) plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), kerb stone of any size, laid in trenches on edges of roads joints fitted in CM 1:4 including excavation in any type of soil, PCC bed, returning filling and removal of surplus soil to a distance not exceeding 50 m from the starting point complete all as specified and directed.
Rolled section/tubular section as in main and cross beams, purlins, rafters, posts where connected to common rafter and running rails etc confirming to Fe-410-W complete all as specified and directed.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work,incl locking arrangement for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified.
S&F Hard Drawn steel wire fabric cut to length bent to shape required and tying,welding to the angle iron frame etc complete all as specified and directed.
AC designer composite ceiling board 4 to 6 mm thick in 600 x 600 mm panel confirming to IS-14682 type-B category-3 including GI frame, holdfast & suspenders complete all as specified and directed by Engineer-in-Charge. Make : Everest
Pre painted galvalume aluminium zinc coating GI based corrugated sheets 0.60 mm thick of any colour having tensile strenght of 550/MPa as in roof covering, cladding to wall fixed with self taping screws complete all as specified and directed.
All as per ser item No 46 above but plain sheets as in ridges complete all as specified and directed.
6 mm thick asbestos cement corrugated sheets as in roof covering fixed with L or J hooks complete all as specified and directed.
All as per ser item No 45 above except sheets complete all as specified and directed.
6 mm thick 2 piece serrated ridge for corrugated or semi corrugated sheets fixed with L or J hooks complete all as specified and directed.
Roughing surfaces of old concrete by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tar felt and brushing neat cement slurry @3kg/Sqm mixed with water proofing compound including 20mm thick screeding in CM (1:4) finished even and smooth mixed with water proofing compound complete all as specified and directed. (WPC shall be measured and paid separatley) Note : No extra cost shall be paid to contractor in r/o any removal of existing roof treatment.
Priming surfaces with bituminous primer confirming to IS-3384 @ 0.40kg/sqm, after drying of primer applying a coat of hot blown bitumen confirming to IS-702 @ 1.20 kg/sqm and layin polymeric water proofing membrane, five layerd with centre core of 90 micron high molecular density polythelene film (minimum weight 3.5 kg per sqm) with end over laps not less than 150 mm and side lap 75 mm complete all as specified and directed for sunken floor treatment or painting with solar reflective paint for roof surfaces.
Providing cement concrete in steps, seismic and other similar bands, parapat concrete etc and railings up to 60 cm in hieght, coping, kneeless apex stones, bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and directed.
Supply only (LW+) water proofing liquid solution of Dr fixit/sikka or equivalent make complete all as specified and directed.
MS drapery rod powder coated including brackets and necessary fitting "as in repair" complete all as specified and directed by Engr-in-Charge.
110 mm bore PVC (SWR) pipe single socketed, in any length with rubber joints fixed to walls complete all as specified and directed.
110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
15 mm bore medium grade galvanished iron water tubing with all fittings and fixed complete to walls or laid in trenches complete all as specified and directed.
All as per ser item No 58 above but 20 mm bore complete all as specified and directed.
500 ltrs capacity rotational moulded polythene water storage tanks cylndrical with closed top hoisted and fixed in position complete all as specified and directed.
All as per ser item No 60 above but 1000 ltrs capacity complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including cast iron P trap, bore of pipe 100 mm and provision of concrete bedding "as in repair" complete all as specified and directed.
Vitreous China wash down water closet pan pedestal pattern, white (excluding fixing bolts, flushing cistern and flush pipe) with P or S trap but including plastic water closet seal, seat cover, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including connection to drain and flush pipe fixed as in repair complete all as specified and directed.
Single piece EWC of size 360 x 680 x 750 mm Make : Jaquar or equivalent including flushing cistern with Soft close seat cover, including trap and necessary fittings in repair complete all as specified and directed.
Single Lever Basin Mixer without Popup waste and 450 mm Long Braided Hoses, Make : Jaquar or equivalent including necessary fittings complete all as specified and directed.
Bib Tap, fancy type, cast copper alloy chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm in repair complete all as specified and directed.
Stop valves of 15 mm bore, but fancy type, chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions including necessary fitting as required at site as in repair complete all as specified and directed by Engr-in-Charge.
Glass shelf with chromium plated guard rails as in repair complete all as specified and directed. Make : Jaquar, Cat Part No AQN -7771.
Health faucet (ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook with all accessories all as approved and fixed as in repairs complete all as specified and directed. Make : Jaguar ALD-CHR-593N
Soap dish as in repair complete all as specified and directed. Make : Jaquar Cat Part No : AQN-7731.
Towel ring square with round flange as in repair complete all as specified and directed. Make : Jaquar Cat Part No : ACN-1121N.
Toilet paper holder as in repair complete all as specified and directed. Make : Jaquar Cat Part No : CAN-1151N.
Corner glass shelf with chromium plated rails incl brackets as in repair complete all as specified and directed. Make : Jaquar, Cat Part No : ACN 1173.
PVC waste pipe 32 mm bore with cup and washers "as in repair" complete all as specified and directed.
Chromium plated 32 mm bore size full threaded with 80 mm height including all necessry washers "as in repair" complete all as specified and directed.
15 mm bore bib taps cast copper alloy with capstan head chromium plated screwed down screwed for iron pipe or brass ferrule "as in repair" complete all as specified and directed.
Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15 mm-90 gms/20 mm-125 gms) in repair complete all as specified and directed.
15 mm bore pillar tap cast copper alloy with capstan head chromium plated screwed down under high pressure with or without lettered hot or cold with long shank and fly nuts screwed for iron pipe complete all as specified and directed.
Concealed stop valve cast copper alloy fancy type chromium plated long shunk and cup screwed down high pressure with crutch or butterly handle screwed both ends for iron pipe or for unions "as in repair" complete all as specified and directed.
15 mm bore angle valve, cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed "as in repair" complete all as specified and directed.
Brass CP shower rose 125 mm size "as in repair" complete all as specified and directed.
20 mm bore brass float valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule "as in repair" complete all as specified and directed.
75 mm bore cast iron floor trap with grating including jointing to waster pipe fixed in cement concrete type B-1 1:2:4 "as in repair" complete all as specified and directed.
75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches "as in repair" complete all as specified and directed.
Sand cast iron 'P' or S trap 100 mm bore for Ind type w/c complete all as specified and directed.
Vitreous China urinal half stall type white including CP spreader, waster pipe etc. "as in repair" complete all as specified and directed.
PVC flushing cistern 10 ltrs capacity with complete in let ball valve as in repair complete all as specified and directed. Make : Perryware/CERA.
Vitreous china wash hand basin flat back size 580 mm x 450 mm excluding taps, waste, chain, plug and porcelain stopper including brackets "as in repair" complete all as specified and directed.
S&F in repair PVC connection 15mm bore with PTMT nuts of length 450mm complete all as specified and directed
Complete removal of existing treatment and applying 1mm thick wall care putty on wall complete all as specified and directed.
Two coats of oil bound distamper on new surfaces over a coat of primer on internal walls complete all as specified and directed.
Two coats cement base paint on newly plastered surfaces including preparation of surfaces on external walls complete all as specified and directed.
Three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces complete all as specified and directed.
Two coats of synthetic enamel paint on new steel surfaces including preparation over a coat of red oxide zinc chrome primer complete all as specified and directed.
Two coats of synthetic enamel paint on new wooden surfaces including preparation over a coat of pink primer complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick surface horizontal or sloping, fair finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking of shutter off shutters from frame) 1.5 sqm and not exceeding 4 sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 101 above but not exceeding 1.5 sqm complete all as specified and directed.
Taking down shutters of any description exceeding 1 square metre but not exceeding 2 square metre each complete all as specified and directed.
All as per ser item No 102 above but not exceeding 1 sqm each complete all as specified and directed.
Factory made PVC door frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube suitable for opening as per site condition complete all as specified and directed and shown on page No 160 of SSR Part-II.
Powder coated Anodised Aluminium frames for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
Powder coated aluminium anodised window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary jointing cleat glazing clips, rubber packing, anodised aluminium snap beading screws etc. complete all as specified and directed.
Powder coated aluminium grill/guard bars to aluminium window complete all as specified and directed.
35 mm thick plain framed II nd class hard wood panelled factory made shutters (two panel or more panel) with lock rail and panel of 12 mm thick BWP commercial ply with size of rail and stiles as per IS 1003 (part-1) kin seasoned and chemically pressure treated complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling, of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed in drawing on Srl page No 156 of SSR 2010 part-II.
35 mm thick plain factory made second class hard wood skeleton shutters, four paneled, open rebated and prepared to receive glass, guage etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered bead for securing glass etc with size of member of shutters complete all as specified and directed in clause 8.24 (a) of SSR Part-I kin seasoned and chemically pressure treated.
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed.
10-12 mm thick frame less Swing Toughened Glass Door (single/double shutter), with etched design openable in both direction and including fixing clips, glass fins, stainless steel handles length exceeding 60 mm 02 Nos on each shutter including floor spring (Make : Hetich or equivalent), floor locks and all accessories complete all as specified and directed by Engr-in-Charge. Make : Saint Gobain or its equivalent. Note : Door size as per site requirement.
All as per ser item No 110 above but 30 mm thick and divided into squares with plain chamfered or rounded mitred and rebated sash bars, any number with stiles and rails complete all as specified and directed in SSR part I section 8 clause 8.24 (b)
35 mm th flush shutters, premium quality, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Powder coated aluminium anodised door shutter shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary jointing cleat glazing clips, rubber packing, anodised aluminium snap beading screws etc. complete all as specified and directed. (Thickness or powder coating not less than 50 micron)
Aluminium body heavy duty double action floor spring suitable for glass shutter at both side rotable complete all as specified and directed.
Aluminium door closer hydraulically regulated universal type, suitable for door shutters complete all as specified and directed.
18/19 mm thick pre-laminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
12 mm thick plywood grade BWR, type BB fixed with screw to timber frame work including dismantling complete all as specified and directed. Make : Green Ply/Kit Ply
0.90 mm thick decorative choice of lamination type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufactureres insturctions complete all as specified and directed.
1.50 mm thick decorative choice of lamination type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufactureres insturctions complete all as specified and directed.
Prelaminated particle board 18/19 mm thick exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination as in kitchen cabinets/shutters fixed with screws to timber framework as in repairs complete all as specified and directed.
All as per ser item No 122 above but 12 mm thick complete all as specified and directed.
Continuous (Paino) hinges, stainless steel bright finish or electro-galvanized width of flap 30 mm (when open) complete all as specified and directed.
40 mm dia, cupboard knob fixed with nut, screw and washer of powder coated aluminium bright finished fixed in repairs complete all as specified and directed.
Hasp and staple size 100 mm powder coated with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames exceeding 1.5 sqm, glazed with putty or fixed with beads complete all as specified and directed. Note : Glass will be measured and paid for separately.
3 mm thick sheet glass, ordinary quality and glazing with wooden beading not exceeding 0.5 Sqm in each pane complete all as specified and directed.
3 mm thick figured glass, pin head type and glazing with wooden beading, not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Aluminium alloy wire cloth, 0.45 mm nominal dia of wire & average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
Aluminium alloy wire cloth, 0.45 mm nominal dia of wire & average width of aperture 1.40 mm and fixed with aluminium wire staples as in repair complete all as specified and directed.
Butt hinges 75 mm sizes, extruded aluminium alloy with galvanised mild steel hinge pin anodised, type C-21 complete all as specified and directed.
All as per ser item No 132 above but 100 mm size, type B-21 complete all as specified and directed.
All as per ser item No 132 above but 125 mm size complete all as specified and directed.
Aluminum alloy powder coated sliding door bolt 300 mm long and not less than 12 mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed.
All as per ser item No 136 here in before but 150 mm long complete all as specified and directed.
All as per ser item No 136 here in before but 75 mm long complete all as specified and directed.
Extruded aluminum alloy handles, fabricated type and powder coated, 100 mm size complete all as specified and directed.
All as per ser item No 139 here in before but 75 mm complete all as specified and directed.
Aluminium alloy, anodised, 200 mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruted sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Floor door stopper of aluminum alloy body and tongue, anodised with hard drawn steel spring and vulcanised rubber piece fixed in floor, over all length of cover plate 140 mm complete all as specified and directed.
Mortice locks Brass vertical type size 100 mm 4 levers brass chromium plated with keys in duplicate as in repair complete all as specified and directed.
Pressed steel frames size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete as specified supplied and fixed as in repair complete all as specified and directed.
Description all as per ser item No 144 but frame size 105 mm x 60 mm complete all as specified and directed.
Mild steel articles such as bands, straps, supports or stays for rain water, hold fasts etc. confirming to Fe 290 Gde-E-165 complete all as specified and directed.
Preparing surfaces of wood and wood based material new of any description and girth not otherwise described and treated with tar or coal tar black paint complete all as specified and directed.
Extra over rates of block board or veneered particle board for external teak wood lipping 6 mm thick fixed with nails in 19 mm thick board complete all as specified and directed.
All as per ser item No 148 above but 12 mm thick board complete all as specified and directed.
One coat of synthetic enamel paint on old wooden surfaces of any description over 10cm width or girth including preparation of surfaces all as specified and directed.
One coat of synthetic enamel paint on old steel surfaces of any description over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed. Note : (i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per ser item No 152 as above here in before but without glazing bar complete all as specified and directed. Note : (i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately
Post anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Post anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
Plain, aluminium sheeting 0.56 mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip, construction joints and straight flashing (length and girth as fixed) in repair complete all as specified and directed.
MODI CONSTRCUTION COMPANY
SODHI TRADING CORPORATION
SINGH CONST CO
RAMAN CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .