Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NOT AVAILABLE | Admitted-Finance |
| 5 | Admitted-Finance ROOM NO 997 GALI NO 3 PART NO 3 GANESH MURTHY NAGAR CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
16 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
Dr Homi Bhabha road new navy nagar colaba mumbai
REPAIRS TO EXTERNAL SERVICES LIKE DRAINS SEWAGE COMPOUND WALL HARD STANDING IN MD ACCN OF AGE BR II UNDER GE NW NOFRA
2023_MES_583180_1
8122
Open Tender
Civil Works
Item Rate
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹70,000
Yes
10 May 2023
27 Feb 2023
21 Mar 2023
27 Feb 2023
16 Mar 2023
11 Mar 2023
27 Feb 2023 - 10 Mar 2023
Amount
Note : Contractor has to attended daily complaint (of sewage) for particular day otherwise penality fo Rs 500/- per day will be leived on contractor.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Demolition brick work or stone/boulder masonary built in cement mortar and removing the rubbish outside MD land complete all as specified & directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (40 mm graded stone agg) as in foundation, filling, and mass concrete, drains, sub base, etc, complete all as specified.
M&L for brick work with sub class B brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work finished even and smooth (without using extra cement) complete as specified.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching, bed plates, coping and the like including from work and finsihing all exposed surface of concrete.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms mould, mi-tred/ stopped ends etc.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified .
Material & labour for cleaning the existing drainage/culvert including removing cover slab of any description and size carefully without damaging and clean soils, spoils, vegetation, silt etc and relaying cover slabs in same position and removing waste materials outside MD Land complete all as directed by Engineer-in-Charge. (Note: The above qty is considered for one year cleaning work will be done on quarterly basis as per plan given and regular complaint will be attended simultanously.
Cleaning and desilting of sewage lines of any size any depth by pumping out /removing liquid waste/sewage ,plugging the ends pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engr-in-Charge.
(a) for 150 mm dia pipe line
(b) for 200 mm dia pipe line
(c) for 300 mm dia pipe line
(Note: The above qty is considered for one year cleaning work will be done on quarterly basis as per plan given and regular complaint will be attended simultanously.
Cleaning & Desilting of manholes depth not exc 1.50 mtr by pumping out/removing liquid waste/sewage & plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpaulin to outside of MD land all as per existing rules and regulations of civil authorities and cleaning the manholes with fresh water etc complete all as specified and directed by Engr-in-Charge.
(Note: The above qty is considered for one year cleaning work will be done on quarterly basis as per plan given and regular complaint will be attended simultanously.
Cleaning and Desilting of manholes depth exceeding 1.50 m but not exceeding 3.00 mtr by pumping out/removing liquid waste/sewage and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside MD land all as per existing rules & regulations of civil authorities and cleaning the manholes with fresh water etc complete all as specified and directed by Engr-in-Charge.
Note: The above qty is considered for one year cleaning work will be done on quarterly basis as per plan given and regular complaint will be attended simultanously.
Cleaning the chocks/blockages in AC/CI/PVC soil waste/rain water pipe of any dia by removing cleaning eye and refixing the same after cleaning the pipe, making good damaged cement joints, dia of pipe not exc 150mm dia and including necessary scaffolding if required complete all as specified and directed.
(i) From Ground floor to 4th floor
(ii) From 5th floor to 8th floor
(iii) From 9th floor to 12th floor
iv) From 13th floor to 16th floor
Cleaning eye (oval access door) for bends , branches, etc of dia not exceeding 100mm at any floor level and refix in same position after cleaning.
Cleaning and removal of foreign material from inside the Gully trap/WC Pan, Nahani trap, Floor trap etc including removing & re-covering of RCC/CI cover and directly buried in the ground to a distance not exc. 50 m along with spreading of bleaching powder complete one or more times all as specified and directed.
M&L for Jointing only cast iron pipes and fittings AC pipes in repair with cement joints for pipes 100mm dia upto ground/stilt plus 16th floors.Complete all as specified and directed by Engineer in Charge
All as per item No. 17 above but 75mm dia & ditto
Excavation in trenches in exc 1.5m wide and n exc 1.5 in depth for foundation etc or for shaffs walls, manholes pier holes etc n exc 10 Sqm on plan and n exc 1.5m depth and getting out in hard/dense soil as specified
S&F for 150mm bore RCC pipe class NP-2 laid and jointed complete with collers including testing all as specified and directed by Engineer-in-Charge.
S&F for 200mm bore RCC pipe class NP-2 laid and jointed complete with collers including testing all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 150mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 200mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 with soil
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed by EIC.
M&L for Cutting into existing manholes for connecting new drains of internal dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, complete all as specified.
M&L for Cutting into existing manholes for connecting new drains of internal dia 200mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, complete all as specified.
Taking down Cast iron of any dia and size fixed on wall or floor including all fittings complete all as specified.
S&F 100 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall complete all as specified.
S&F 75 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall complete all as specified.
Refixing of 100mm dia cast soil waste pipe in any length after cleaning and jointed with neat cement paste fixed to wall.
Refixing of 75mm dia cast soil waste pipe in any length after cleaning and jointed with neat cement paste fixed to wall.
S&F in repair 75 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 75 mm dia branch piece single branches any radius fixed to ovel acess door and jointed with neat cement paste.
S&F in repair 100 mm dia CI branch piece single branch of any radius with ovel access door and jointed with neat cement paste.
M&L in repair cast iron Nahani trap of size 100mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F in repairs Cast iron work grade FG 150, machined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles machined each exceeding 5 Kg by weight complete all as specified and directed by Engineer in Charge.
S&F in repairs PVC (SWR) 160 mm bore pipes single socketed in any length with rubber ring joints, and fixed to wall, complete all as specified and as directed.
S&F in repairs 160 mm bore PVC (SWR) bends complete all as specified and as directed
S&F in repairs PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints,and fixed to walls, complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) bends complete all as specified and as directed.
S&F in repairs PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints,and fixed to wall , complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) bends complete all as specified and as directed.
S&F in repairs 75mm (SWR) branch piece, single (single Y) equal or unequal provided with oval access door, complete all as specified.
S&F in repairs 110mm (SWR) branch piece, single (single Y) equal or unequal provided with oval access door, complete all as specified.
S&F in repair vitreous china wash hand basin flat back of size 550x400mm including bracket, brass chromium plated waste coupling of 32 mm bore and pillar tap 15mm bore dia fancy type complete all as specified and directed.
S&F in repair 10 ltr capacity PVC syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connection to pipe complete all as specified and directed.
S&F as in repairs white vitreous china wash down water closet pan (pedestal pattern) with PVC seat cover including connection to drain pipe and flushing pipe all as specified.
S&F in repairs water closet squatting pan (Orissa pattern) 580x440mm, white with integral foot rests including connecting to trap and to flushing pipe antisyphonage pipe including making good to floor (excluding flushing cistern and flush pipe).
Supply and fixing in repairs bib tap 15 mm dia ,CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as directed.
Taking down existing cement or cement lime plaster and preparation of surfaces of walls of any description incl racking out joints backing for scrubbing down with water including rubbish out side MD land complete all as specified and directed.
M&L for rendeing 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound at the rate of 3% of cement or as per manufacturers instructions. Note: Integral water proofing compound shall be measured & paid separately)
Supply only integral water proofing compound conforming to IS-2045
M&L for rendeing 20 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats 15 mm thick and 5 mm thick coat mixed with integral water proofing compound at the rate of 3% of cement or as per manufacturers instructions, complete all as specified and directed by Engr- in Charge. Note: Integral water proofing compound shall be measured & paid separately)
Preparation of new plastered surfaces of wall and applying two coats of Acrylic Emlusion Exterior paint of required shade (Two or more coats applied @ 1.67 ltr/ 10 Sqm and including priming coat of exterior primer applied @ 2.20kg/Sqm, complete all as specified and directed.
Excavating in post holes in hard /dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for Cement concrete (1:3:6) type C-2 by using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified & directed.
S&F as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 , complete all as specified.
Supply only Chain link MS galvanisd fencing (weight n.exe 3kg/m2, any size or type, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified.
S&F in repairs barbed razor type concertina coil,9SWG hot galvanized spring tensile wire of UTS 145 to 150 N/Sqm,zinc coating 250 to300 gms/sqm, dia of coil when un-streched shall be 610 mm having minimum of coil (GI strip) 1.625 Kg/Rm, hot dip galvanised razar ribben tape of size 0.50 mm thickness,19mm wide before wraping on central core wire fixed with 1.66 mm thick GI clips (minimum 25 Nos/RM) and special nut and bolts to hold two coils together and having 50 circles and covering 6 running meter length complete all as specified and as directed.
S&F factory made RCC cover slab of size 450mm x 750mm, X 75mm thick including placing over directed locations, including reinfircement 10mm dia bars at spacing 100mm C/C both ways all complete all as specified and directed by Engineer-in-charge.
M&L for heavy duty cement concrete interlocking paver tiles 80 mm thick, M-40 grade having glossy finish (colour and pattern approved by GE) (tested as per IS 1237-1980) laid over and including 50 mm thick dry sand cushioning and voids filled with dry sand and surface compact, including compation by means of surface vibrator & removing of old broken tiles, complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement & pigments, set, jointed and pointed in neat cement slurry in floors over screed bed or bedding layer of mortar in CM (1:4) 20mm thick for laying tiles, complete all as specified. including demolition of existing tiles.
Dismantling floor, hearth or wall tiling (fixed at any portion but not backing) including cement mortar bedding and removing and removing rubbish off the premises (outside MD land) complete all as specified and directed.
M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm, as in floors etc over and including 15 mm thick cement mortar screed bed 1:6 for laying floor finishes set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white or colour cement to match compleate all as specified and directed.
M & L glazed coloured ceramic tiles 300X200X6 to 7 mm or 300x450x 6 to 7mm thick laid on vertical surfaces such as skirting/dado etc over and including 10 mm thick rendering cement mortar 1:4 as backing coat set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and directed.
M&L stone walling of squared rubble brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 all as specified.
M&L stone walling of squared rubble brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone all as specified.
M&L for raking out cement joints/ pointing of random rubble or polygonal rubble uncoursed or brought up to courses masonry built in cement mortar complete all as specified & directed.
M&L for Keyed pointing in CM 1:3 to random or polygonal rubble, uncoursed or brought upto course masonry complete all as specified & directed.
Preparation of new steel surfaces & apply two coats of synthetic enamel paint over a coat of red oxide, complete all as specified.
S&F as in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Unitech Enterprises
jkconstruction
Shivam Enterprises
vikas construction
I.J Enterprises
PRABHU ASSOCIATES
SAHU AND SAHU CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .