Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC WARD NO 20 BIRLA HOUSE JEDERUA KALA DISTT GWALIOR M P 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.8 L+₹81,250 (3.13%)Rejected-Finance 197 C P COLONY MORAR GWALIOR GWALIOR MADHYA PRADESH 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF ADM AREA GWALIOR
AIR FORCE STATION GWALIOR
IMPROVEMENT TO DSC LIVING IN BILLET P 585 INCLUDING RECREATION ROOM AT AF STATION GWALIOR
2021_MES_489478_2
8169/E8
Open Tender
Civil Works
Item Rate
180 days
AIR FORCE STATION GWALIOR
Class E and above and category a(i)
8 documents required · 8 mandatory
₹500
GE AF ADM AREA GWALIOR
₹49,000
Yes
23 Feb 2022
4 Jan 2022
26 Jan 2022
4 Jan 2022
24 Jan 2022
11 Jan 2022
4 Jan 2022 - 8 Jan 2022
60 days
Amount
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area not exceeding 1.50 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
S&F pressed steel frames made out of 1.25mm thick mild steel sheets for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, of size 125x60mm complete all as specified and as directed:- Note : 10mm deformed bar shall be provided in bottom portion in each frame. The rate for the same is included in rate quoted against this item.
S&F 35mm thick factory made plain framed, panelled shutters (two panel) of IInd class hard wood rail and styles with lock rail and panel of 9 mm BWP commercial ply. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified.
S&F 35mm thick factory made second class hard wood glazed and skeltron door shutter open rebated and prepared to receive glass or gauge etc divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters as specified in SSR Part-I (2009) section 8 clause 8.24 (a).
S&f side hung shutter made out of 1.25 mm thick pressed steel frame steel window with profile 100x40 mm sheet welded with double shutter double leaf of rolled Z steel section as per IS 1038 including suitable peg stay made out of mild steel, box type hinges 02 Nos in each shutter, MS tower bolt of size 100 mm with plate-02 Nos in each shutter, MS handle of size 125 mm 01 NO in each shutter welded to frame and MS square shape guard bars of size 12 mm welded to frame @ 150 mm C/C both way over and including MS flat of size 30x5 mm all around the frame complete all as specified and directed.
S&f top hung shutter made out of 1.25 mm thick pressed steel frame steel ventilator with profile 100x40 mm sheet welded with double shutter of rolled Z steel section as per IS 1038 including suitable peg stay made out of mild steel, box type hinges 02 Nos in each shutter, MS tower bolt of size 100 mm with plate-02 Nos in each shutter, MS handle of size 125 mm 01 NO in each shutter welded to frame and MS square shape guard bars of size 12 mm welded to frame @ 150 mm C/C both way over and including MS flat of size 30x5 mm all around the frame complete all as specified and directed.
M&L for two coats of synthetic enamel paint over and including a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified
M&L for preparation of old painted surface of wood and wooden based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surface of steel material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S&F butt hinge, medium weight, cold rolled and fixed of size 100 mm complete all as specified and directed.
S&F anodised aluminium barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F anodised aluminium handles fabricated type of size 150mm complete all as specified and directed.
S&F anodised aluminium sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of size 300 mm complete all as specified and directed.
S&F galvanised steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or stainless steel wire staples etc. in wooden door / window, completed all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 3 mm thick figured glass, pin headed type and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed.
Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level and removing the debris to a distance not exc 2.5 Km from the starting point. Complete all as specified and directed.
Taking down old cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as directed.
M&L for 25 mm thick PCC, 1:2:4 Mix, Type B0 (Using 12.50 mm graded stone aggregate) as in sub base of floor cement complete all as specified and directed.
M&L for mirror polished machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
Description same all as per item No 22 above but, as in skirting/dado over and including 10mm thick rendering in cement mortar (1:3) complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface on wall in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces on walls and applying two coats of oil emulsion distemper over and including a thin layer of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed.
M&L for complete removal of existing treatment of old surface of wall including cornices surfaces by rubbing/sanding and applying two coats of distemper oil emulsion over and incluing one coat of primer and thin layer of JK/ Birla white wall care putty to obtain the desired/ true surface of wall complete all as specified and directed.
M&L for two coats of white wash on old ceiling surfaces including preparation of surfaces complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing the debris to a distance not exc 2.5 Km from the starting point complete all as specified and directed.
M& L for brushing neat cement slurry with 3.0kg of cement per sq. Metre on old concrete surfaces complete all as specified and directed.
M&L for PCC 1:2:4 mix, type B1 (using 20 mm graded stone agg) as in lavelling course to maintain true roof slope, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick screed bed or bedding layer in CM (1:3) mixed with water proofing compound as per manufacturers instructions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only WPC integral water proofing compound complete all as specified and directed.
M&L for roof treatment with APP based polymeric membrane, 3mm thick (minimum), weighting 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.2 kg per Sqm over a coat of bituminous primer @ 0.3 litre per sqm surface, application of APP modified membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. One coat of aluminum paint @0.10 Kg/Sqm over the APP Modified Membrane shall be provided complete all as specified and directed.
M&L for cutting out cracks to ‘V’ section in existing roof or terracing, cleaning out, wetting and filling solidly a hot mixture of bitumen and dry sand in proportion of 1:1 by weight complete all as specified and as directed
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Disconnecting existing water storage tanks of capacity exc. 500 Ltr but n. exc 1000 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
Disconnecting existing water storage tanks of capacity exc. 250 Ltr but n. exc 500 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
Taking up or down 15mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Re-fixing of old steel GI tubing, 15mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed.
Re-fixing of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed.
S&F GI tubing 15 mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
S&F GI tubing 20 mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of size 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of size 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of size 110mm bore complete all as specified and as directed.
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab/Grandlay Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Asian/Jindal, Make of Laminated Sheet:-/Hylam/National)
All as per item No 49 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
All as per item No 49 hereinbefore but point wiring for one 5 pin socket outlet, on same board .
All as per item No 49 hereinbefore but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white/ ivory finish complete all as specified. (Make :- Anchor(Panta)/ Cona/ Leader)
M&L for socket outlet 2 in 1, 5 pin, 6 Amps, 240 volts flush type white/ ivory finish complete all as specified.Make :- Anchor(Panta) , Cona , Leader
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
S&F for switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt . Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified. (Make-Havell's Cat Part No LUMILINEBS20WLED865SPCWH/Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL)
S&F Street/ Security light fittings, 1X35 Watt, new generation energy saving & enviromental friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LED as light sourcewith acrylic cover suitable for pipe of dia 40 mm (maximum) with and including GI bracket made out of 40 mm dia light grade GI pipe of length 1.20 including necessary nuts, bolts washers and wire of suitable lenght for connection complete all as specified and directed. Make: Havells/ CG/ Surya
S&F LED mirror light decorative box type fitting, 10 watt, 2 feet, pre-wired with LED tube complete and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted three core cable including all accessories and fixing the fitting on round PVC block on wall etc complete all as specified and director. Make: Havells/ Surya/ CG
Dismantling & Taking out MCB DBs any size , any type and capacity and remove materials from site of works. Complete all as directed.
S&F for sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires. Complete all as specified. (Make;ABB,Schneider,Legrand, havells)
S&F in repair factory made epoxy powder coated distribution board TP&N, 4 (Way) (VTPN MCB DB) with metal door (IP-43 Protection), fabricated from minimum 1.60 mm CRCA sheet and fixed flush to wall and suitable for universal mounting with and including 200 Amp copper bush bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removablr gland plates with knokouts including provision for housing MCCB in the incomimg and MCBs in outgoing complete all as specified and directed. (Make:ABB,Schneider,Legrand, Havells) Note: Old existing MCCB DBs VTPN any type as retrived from site shall be deposited in MES store yard.
Dismantling & Taking out MCB's/ Isolatotrs and metal clade box of any size complete all as specified and directed.
S&F for MCB single pole 6 to 32 Amps, "B" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider/Havells)
S&F for MCB Single pole and neutral 40 to 63 Amps 10 KA, 'B' series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider/Havells )
S&F MCCB, 3 Pole, 125 Amp, 50 Hz, 415Volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having type DPX 160 fixed in distribution board complete all as specified and directed. Make: Legrand/Siemens/ABB/Havells
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiring with any type of conduit. (Make of Cable/wire:- : Havells /Finolex/Polycab/Grandlay Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering/Asian/ Jindal Make of Laminated Sheet:-/Hylam/National)
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as specified. (Make:ABB/Schneider/Legrand)
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed. Note: Earth strip and protection pipe upto and including 7.5m deemed included in unit rate quoted by the contractor.
S&F LED bracket type light complete with high diffuser 3 Watt 220 Volts, AC decorative type complete all specified and directed. Make: Havells/ Surya/CG
NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
lodhi builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .