| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.9 L+₹4.5 L (20.9%)Rejected-Finance FLAT NO S 4 DOOR NO 10 4 107 17 SRINIVASA TOWERS SRI RAMNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Not being lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
7 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE WELLINGTON
Headquarters, Commander Works Engineers, Military Engineer Services Ministry of defence Wellington, Barraks-Post, The Nilgiris, PIN 643231
MAINT AND REPAIRS TO HIGH TENSION (HT) 11 KV SYSTEM, BREAKERS, RMUS, REPSIRS/REWINDING OF DISTRIBUTION TRANSFORMERSS, DEHYDRATION/TOPPING-UP OF TRNSFORMER OIL INCLUDING ALLIED WORKS UNDER GE DSSC WELLINGTON
2022_MES_513120_1
84606/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
WELLINGTON
Class E
Category b(i)/b(ii)
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹46,000
Yes
20 May 2022
10 Mar 2022
15 Apr 2022
10 Mar 2022
7 Apr 2022
25 Mar 2022
11 Mar 2022 - 17 Mar 2022
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out/laying of UG Cables, GI Pipe etc. and getting out in hard dense soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed..
M&L Providing sand cushioning for protection of UG cable in trenches with dry (coarse) river sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 x 180 x 40 mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified & as directed.
M&L GI pipe light grade with all running fittings, laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and directed. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
All as per Item Sl No 06 here in above but of bore 80 mm complete all as specified and as directed.
M&L Boring under road manually with labour suitable for inserting upto 100 mm bore pipe at a depth of 0.75 to 1.0 m complete all as specified and as directed.
M&L Cutting the existing hard standing/PCC/WBM road at a depth not less than 60 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete including finishing the surfaces by providing 20cm thick cement concrete1:2:4, type B1 using 20 mm graded stone aggregate, finishing to a uniform smooth surface complete all as specified and as directed by the Engr-in-Charge/GE. NOTE for Item Nos 1, 8 & 9 : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the excavation/boring/road cutting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.
Supply, laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade (Earthed), of size 95 sqmm, 3 core in trenches / through GI pipe / fixed along with pole structure etc complete all as specified and as directed by the Engr-in-Charge/GE. NOTE : Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Earthing complete with Copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by the Engr-in-Charge/GE. NOTE FOR ITEM NO 15 &16 : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
M&L Laying earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified.
M&L Laying earth continuity conductor or main earthing lead of 25x3 mm copper strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Chain link fencing including line wires, any size/type of standard rails/angles, straining bolts etc. including provision of binding wires complete all as specified and as directed by the Engr-in-Charge/GE.
M&L MS angle iron post & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets for securing wire mesh conforming to Fe-290 E-165 including painting with one coat of red oxide primer & two coats of aluminium paint complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Coarse River Sand filling, levelling, watering & consolidation in 15 cm layers on the level ground surface in Sub-Stations complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Spreading & leveling stone aggregates of size 20 to 25 mm on sand filling in the Sub-Stations complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Plain Cement Concrete 1:2:4, Type B-2, using 40mm graded stone aggregate for transformer platform / plinth etc. & finishing the surface even & smooth using extra cement including necessary formwork & 15 mm thick rendering in cement mortar 1:4 complete all as specified & as directed by Engr-In-Charge.
M&L Cutting grass, bushes, creepers, weeds, unwanted plants/growths, area cleaning etc in and around Electric Supply Installations, LT Panels, Feeder Pillar Boxes or any other locations as decided by Engr-In-Charge/GE and removing rubbish off the premises complete all as specified and to the entire satisfaction of the Engr-in-charge/GE. NOTE : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia suitable for 11000 volts grade including dismantling/taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge/GE.
S&F lightening arrester non-linear metal oxide type, complete with all fittings, transmission/distribution class, discharge capacity 65 Kilo amps suitable for 11 KV out door type including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unserviceable lightening arrestor including strap bolts, nuts and washers etc. complete all as specified and as directed by the Engr-in-Charge/GE.
M&L tinned copper flexible jumper of current rating 200A/400A (as per ground requirement) of minimum 2 mtr length suitable for operating voltage 11 KV, after carefully removing the old unserviceable flexible jumpers from AB switches complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Swing out expulsion fuse, single pole (Drop Out Fuse) with fuse carrier, fuse element mounted on insulator & fitted on steel frame etc for 11000 volts of capacity 25 amps dismantling/taking down old unserviceable one complete all as specified and as directed complete.
M&L Switch air break, gang operated (GOD), out door type, triple pole, HT 11 KV, 400 Amps, vertical type with 9 insulators mounted with fixed contacts of phosphor bronze and moving contacts of copper, manually operated from ground level with operating mechanism including mild steel galvanised, medium grade, 25mm bore, single length operating rod, pad locking arrangement dismantling/taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Servicing the existing Gang operated Air Break switch, operated from ground, of any type/capacity, 11 KV, 3 Pole, including greasing or by applying petroleum jelly, replacing worn out/damaged/rusted contacts (both Male & Female), nuts, bolts, washers, etc. and providing coloured sleeves for jumper connections complete all as specified and as directed by the Engr-in-Charge/GE.
M&L ACSR conductor any size for HT 11 KV over head line including stringing and fixing on pole and binding or for making jumper connections etc. complete all as specified and as directed by the Engr-in-Charge/GE. (Note : Size/Grade/Type of ACSR conductor shall be as per site requirement & as directed by Engr-in-Charge)
M&L Breather assembly with fresh silica gel suitable for outdoor type 11/0.433 KV transformers of capacity up to 500 KVA including taking down un serviceable breather assembly from the transformer complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Temperature gauge meter suitable for outdoor type 11/0.433 KV transformers of capacity up to 500 KVA including taking down unserviceable temperature gauge meter from the transformer complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and filling in Transformers, Transformer breathers fresh silica gel, blue after carefully removing the breather unit and old silica gel and refixing the same complete all as specified and as directed by the Engr-in-Charge/GE.
Supply and filling in Transformers with Transformer oil first hand of dielectric strength not less than 60 KV at 2.5 mm Gap, conforming to IS-335 including testing of BDV of Oil complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Dehydration/Filtration of Transformer oils of Transformer/Switch gears using on load mobile stream line transformer oil filtration plant (hot oil filtration plant) at site for removing the moisture contents and carbon deposits from the oil and bringing it to the dielectric strength not less than 50 KV AT 2.5 mm Gap after filtration including testing of BDV of Oil complete all as specified and as directed by the Engr-in-Charge/GE. Note for Item Nos 35 & 36 : Necessary filling equipments/devices/clean empty drums etc. shall be arranged by the Contractor & cost of the same is deemed to be included in the unit quoted rates.
M&L Preparing old painted outer surfaces of Transformers, 11/0.433 KV including all exposed surfaces of steel items fixed with the transformer without dismantling and applying two coats of weather proof synthetic enamel paint of approved grade/shade including writing of SM/MES numbers and Capacity of Transformer complete all as specified and as directed by the Engr-in-Charge/GE for Transformers of following capacity :
100 KVA to 250 KVA
300 KVA to 500 KVA
M&L Preparing old painted surfaces and applying two coats of aluminium paint on HT Steel tubular poles of any type/size for 2-pole structure including cross arms, back plates, bracings, all exposed surfaces of steel items fixed with the pole without dismantling complete all as specified and as directed by the Engr-in-Charge/GE.
All as per item No. 38 here in above but for 4 pole structure complete all as specified and as directed.
S&F danger notice plate for HT of size 25cm x 20cm x 1.60mm size, mild steel sheet, vitreous, powder coated, letters and figures and conventional skull & bones in signal red colour and fixed with MS clamps bolts of required size complete all as specified and as directed by the Engr-in-Charge/GE.
M&L LT Bushing insulator with brass spindle, nuts, check nuts & washers etc. suitable for outdoor type 11/0.433 KV Transformers of capacity up to 500 KVA including taking down unserviceable one from the transformer complete all as specified and as directed by the Engr-in-Charge/GE.
M&L HT Bushing insulator with brass spindle, nuts, check nuts & washers etc. suitable for outdoor type 11/0.433 KV Transformers of capacity up to 500 KVA including taking down unserviceable one from the transformer complete all as specified and as directed by the Engr-in-Charge/GE.
M&L Overhauling of RMU unit of capacity up to 800A, 11 KV, 250 MVA of any make for servicing, repairs, and re-assembling complete comprising of essential/necessary services including testing and commissioning to the entire satisfaction of Engr-in-Charge/GE.
M&L Overhauling of VCB unit of capacity up to 800A, 11 KV, 250 MVA of any make/model for servicing, repairs and re-assembling complete comprising of essential/necessary services including testing and commissioning to the entire satisfaction of Engr-in-Charge/GE.
Note:- for Item Nos 43 & 44 : Subject job of Overhauling/Repair of RMU & VCB units shall comprise of the following essential/necessary services/jobs : (i) SF 6 gas pressure level to be checked. (ii) SF 6 gas filling to be carried out when the gas pressure is low. (iii) All the connected meters to be checked and calibrated if required. (iv) Checking of control wiring, Push buttons, Indication lamps, tripping coil, tightening and any other related defects to be rectified/replaced in the event of non-functioning/working. (v) Checking and calibration of connected relays. (vi) Cost of additional hardware like bolts, nuts, washers, spring washers etc. to put the RMU/VCB in 100% serviceable condition is deemed to be included in the rates quoted. (vii) The complete job of overhauling/servicing of the RMU/VCB Units is to be got done from the OEM/Sister concern/Auth channel partner only & in the presence of rep of Engr-in-Charge.
(viii) All works shall be carried out with the help of pre-planned programs so that shutdowns can be given in a systematic manner. The pre-planned program shall be submitted by the contractor in consultation with the Engr-in-Charge. Contractor shall not be able to claim any compensation if a scheduled shut down could not be given on dates planned for. (ix) Test certificate in Original duly signed by the Reps of OEM/Contr & MES after repair/overhauling is to be submitted by the contractor.
M&L Disconnection/dismantling of the under mentioned plinth/pole mounted outdoor type 11/0.433 KV Step Down Transformers of capacity 100 KVA to 500 KVA from primary/secondary side, transportation to MES Power House or workshop by crane or any other mode for carrying out the repairs, decanting transformer oil, storing the same in suitable clean containers, disconnecting the live parts, opening the top cover, dismantling bushing, lifting core assembly, checking the winding for slackness, winding burning, distortion of core winding, cleaning and drying the tank, varnishing, baking by oven heating, cleaning conservator, cooling tube including necessary leak testing, lowering of complete core assembly inside the fully cleaned transformer, after repair and testing & re-installation in original/new position, connection of cables on primary/secondary side and commissioning complete including taking out of temporary installed transformer (if any) after necessary disconnection of cables from primary/secondary side etc. complete all as specified and as directed by the Engr-In-Charge/GE of the following capacity of transformers :
Note : (i) Items/Jobs w.r.t. disconnection/dismantling of Transformer for repair/rewinding etc. shall be executed only as per the direction of Engr-In-Charge as on reqmt basis. (ii) Rate quoted is deemed to be inclusive of cost of transportation of Transformer (if any) from worksite to workshop & back. (iii) Rate quoted is deemed to be inclusive of cost of factory inspection (if any) by Engr-In-Charge/GE during currency of the work/job as part of work check/supervision. (iv) Replacement/Topping Up/Dehydration of Transformer oil, defective spares like gasket, breathers, porcelain bush with copper stud, nuts, bolts, washers, re-winding etc. shall be measured and paid separately under relavant items of Sch.
Transformer capacity 100 KVA to 250 KVA
Transformer capacity 300 KVA to 500 KVA
M&L Transformer Oil Leakage arresting by providing synthetic bonded rubberised cork gasket sheet 6 mm thick for top cover and primary / secondary bushes etc. complete all as specified and as directed by the Engr-In-Charge/GE.
Transformer capacity 100 KVA to 250 KVA
Transformer capacity 300 KVA to 500 KVA
M&L Copper wire/Copper strip for H.V. (11 KV) / L.V. (1.1 KV) coils including high quality paper insulation (DPI) complete all as specified and as directed by the Engr-In-Charge/GE.
M&L Aluminium wire/Aluminium strip for H.V. (11 KV) / L.V. (1.1 KV) coils including high quality paper insulation (DPI) complete all as specified and as directed by the Engr-In-Charge/GE. Note for Item Nos 47 & 48: (i) Items/Jobs w.r.t. re-winding of HV/LV coils/limbs shall be executed only as per the direction of Engr-In-Charge/GE as on reqmt basis. (ii) Gauge and quality of copper wire shall be got approved from Engr-In-Charge & GE prior to commencement of each work/job. (iii) Rate quoted is deemed to be inclusive of cost of factory inspection (if any) by Engr-In-Charge/GE during currency of the work/job as part of work check/supervision. (iv) IR values shall be taken after re-winding in the presence of JE E/M/Engr-In-Charge & report generated duly signed by all concerned.
M&L Transportation of Trolley Mounted/Spare 11/0.433 KV Distribution Transformer of capacity upto 500 KVA from Sub-Stn No-02 or any other location to any of the Sub-Station locations under GE DSSC or vice-versa by crane or any other mode & making HT & LT Cable Connections, temporary Earthing connections etc. including charging & testing of the Transformer complete all as specified & as directed to the entire satisfaction of Engr-In-Charge/GE.
M.V.K.ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .