Tender Value
₹56.6 L
EMD Value
₹1.1 L
Closing Date
15 May 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in Central/State Government department or PSUs of Central /State Government."
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
52 conditions · 1 needing a document upload
Whether the cost of earnest money deposited
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE SUBMITTED.
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Name of work:-1) Provision for one nos. of existing building including with OPL 1 renovation of toilet, Boundary wall and connecting road in OPL 1st under jurisdiction of Sr.DEN/IV/LMG 2) Provision for new administrative block office building double storied 1600 sq.mtr including CO chamber, 04 AC's chamber, meeting hall, Battalion office (8 dealing clerk with separate section for receipt and dispatch section) with record room, IPF office with record room, Quarter Master office with store room, security control room, BN quarter Guard, Armourer shop and 8 nos Room (Kote and Magazine room) for keeping Arms & Ammunition etc. under jurisdiction of Sr.DEN/II/LMG .
EL-LM-25-26-45-RT
EL-LM-25-26-45-RT
Open
Works - General
120 Days
Hojai, Assam
₹0
₹1.1 L
15 May 2026
24 Apr 2026
1 May 2026
136 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 8,23,681.76 | ||
| — | 100.00 | — | — | ||
| Supply and wiring of light point through rigid PVC casing-capping with all necessary accessories for surface wiring using 1.5 sq.mm FRLS PVC insulated copper conductor cable (1100 V grade) conforming to IS:694. The point shall be controlled by flush type 5/6 Amp switch mounted on a hard plastic moulded/modular board. The casing-capping shall be fixed on wall/ceiling with MS screws (6x40 mm) and rawl plugs at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 15,858 | |
| — | 45.00 | — | — | ||
| Supply and wiring of ceiling fan point through rigid PVC casing-capping with all necessary accessories for surface wiring using 1.5 sq.mm single core PVC insulated copper conductor cable, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 5/6 Amp switch mounted on a hard plastic moulded board, including 300 W box-type stepped electronic fan regulator. The ceiling fan connection shall be made through a ceiling rose. The casing-capping shall be fixed on the wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, complete with all connections, accessories, testing and commissioning as directed by the Engineer-in-Charge. | — | — | — | 11,369.7 | |
| — | 100.00 | — | — | ||
| Supply, fitting, fixing, connection and commissioning of 18/20 W LED indoor light fitting complete with LED tube and all accessories. The fitting shall be connected with 1.5 sq.mm PVC insulated flexible copper wire through PVC pipe/casing-capping as required at site, including all necessary connections, fixing, testing and commissioning complete as directed by the Engineer-in- Charge. | — | — | — | 31,420 | |
| — | 45.00 | — | — | ||
| Supply and fiting of ceiling fan 1200/1400 mm sweep decorative should be ISI marked conforms to IS374-1979 with latest ammendements and should be 5 star ratingSupply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. | — | — | — | 1,22,850 | |
| — | 35.00 | — | — | ||
| Supply and wiring of 5/6 Amp, 5-pin plug point through rigid PVC casing-capping with all necessary accessories for surface wiring using 1.5 sq.mm single core PVC insulated copper conductor cable, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 5/6 Amp switch mounted on a hard plastic moulded board. The casing-capping shall be fixed on the wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in- Charge. | — | — | — | 5,906.95 | |
| — | 25.00 | — | — | ||
| Supply and wiring of 15/16 Amp, 6-pin plug point through rigid PVC casing-capping with all necessary accessories for surface wiring using 4 sq.mm single core PVC insulated flexible copper conductor cable, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 15/16 Amp switch mounted on a hard plastic moulded board. The casing- capping shall be fixed on the wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 7,472 | |
| — | 12.00 | — | — | ||
| Supply and wiring of exhaust fan point through rigid PVC casing-capping with all necessary accessories for surface wiring using 1.5 sq.mm single core PVC insulated flexible copper conductor wire, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 5/6 Amp switch mounted on a hard plastic moulded board. The exhaust fan connection shall be made through a ceiling rose. The casing-capping shall be fixed on the wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 3,295.92 | |
| — | 12.00 | — | — | ||
| Supply, installation, testing and commissioning of 300 mm sweep heavy-duty exhaust fan, suitable for 230 V, 50 Hz, single-phase AC supply, complete with copper winding motor, ball bearing, powder-coated metal body/blades and protective safety guard conforming to relevant IS standards. The fan shall be firmly mounted on wall/window with suitable frame, clamps, fasteners and vibration-free arrangement. The work shall include proper electrical connection with suitable cable, earthing, fixing materials, nuts, bolts, washers and all consumables, complete as required at site and as directed by the Engineer-in-Charge. | — | — | — | 15,685.8 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of AC power point with wiring, including 16 Amp MCB and socket outlet, complete with modular plate, frame and mounting box (minimum 3 mm thickness and 50 mm inside depth). Wiring shall be carried out using 6 sq.mm single core PVC insulated FRLSH copper conductor cable through PVC concealed rigid conduit, with earth continuity by 1 sq.mm PVC insulated copper wire. The work shall include supply and fixing of all necessary accessories such as PVC bends, tees, junction boxes, fasteners, etc., proper termination, connection, earthing and testing complete. Any damaged concealed surface during installation shall be restored and painted to match the existing surface colour, as directed by the Engineer-in-Charge. | — | — | — | 1,049.48 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of 2 Ton capacity, BEE 5-Star rated Split Type Air Conditioner suitable for 230 V ±10%, 50 Hz, single phase AC supply, conforming to latest BEE and BIS standards. The unit shall consist of high wall indoor unit and outdoor unit with rotary/inverter type hermetically sealed compressor, 100% copper condenser and evaporator coils, copper refrigerant piping with nitrile rubber insulation, electronic control system, cordless remote controller, drain piping and suitable mounting arrangement. The work shall include supply and installation of copper refrigerant pipes with insulation, interconnecting control cable, condensate drain pipe, outdoor unit mounting stand/bracket with vibration isolators, proper electrical connection with earthing, gas charging (if required), testing, vacuuming and commissioning complete. All necessary accessories such as sleeves, clamps, saddles, fasteners, insulation tape, PVC conduit for control wiring etc. shall be provided by the contractor, complete as required at site and as directed by the Engineer-in-Charge. | — | — | — | 92,000 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of 6-way TPN Vertical Distribution Board (DB) with TPN MCB incomer and (6+6+6) outgoing modules, conforming to IS:8623 (Part 1 & 3) / IEC:61439 (Part 1 & 3). The DB shall be single door type, IK-08 protection, IP-43, fabricated from CRCA sheet steel and powder coated in RAL 9003 shade. The DB shall be complete with the following C-curve MCBs: 63 A TPN MCB (C-curve) - 1 No. (Incomer) 32 A DP MCB (C-curve) - 2 Nos. 16 A SP MCB (C-curve) - 3 Nos. 10 A SP MCB (C-curve) - 3 Nos. The board shall be properly concealed and fixed on the wall, including busbars, neutral link, earthing arrangement, internal wiring, glands, fasteners and all accessories. The work shall include connection, testing and commissioning complete, as required at site and as directed by the Engineer-in-Charge. | — | — | — | 24,070 | |
| — | 5.00 | — | — | ||
| Supply and erection of earthing by 50 mm GI pipe, 4 mtr long 3.6 mm thickness including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuity by 25x3mm GI strip with GI nuts bolts washer etc. including welding, earth resistance flag etc. as per Drg. No. DRG No. PCEE-ELG-DRG-2024-1-Rev-1 Dt. 28.07.2025. The GI Strip ( should be welded with the earth pipe. The pipe is provided with at tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value. The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be pre casted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement | — | — | — | 8,049 | |
| — | 300.00 | — | — | ||
| Excavation of cable trench of size 1.0 metre depth x 0.5 metre width below Ground Level (GL) in all types of soil, including dressing, leveling and preparation of trench bottom.The work shall include laying of armoured cable in the trench, providing sand cushioning, brick protection on top of cable, and refilling the trench with excavated soil in layers with proper ramming and compaction .The item also includes supply and fixing of suitable size crimping lugs for termination of armoured cable, proper jointing/termination, connection, testing and commissioning complete in all respects. All materials such as sand, bricks, lugs and other consumables shall be supplied by the contractor .Complete in all respects as per direction of Engineer-in-Charge at site. | — | — | — | 36,537 | |
| — | 300.00 | — | — | ||
| Laying, installation and commissioning of XLPE insulated, armoured aluminium conductor LT/HT power cables of different sizes, partly along the pole and partly through ground in cable trench, including proper dressing, clamping on pole and laying in trench as per standard practice. The work shall include loading, unloading and transportation of cable from Railway store to the actual work site by the contractor's own arrangement, laying, termination and testing complete as directed by the Engineer-in-Charge. | — | — | — | 12,279 | |
| — | 385.00 | — | — | ||
| Supply and drawing of main line wiring using single core 10 sq.mm PVC insulated flexible copper conductor cable, with earth continuity by 16 SWG bare copper wire, through rigid PVC casing-capping/conduit of approved quality. The casing/conduit shall be fixed on wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm. (One RM shall consist of two wires.) The work shall include supply, fixing, connection, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 31,881.85 | |
| — | 1299.00 | — | — | ||
| Supply and drawing of sub-main line wiring using single core 4 sq.mm PVC insulated flexible copper conductor cable, with earth continuity by 16 SWG bare copper wire, through rigid PVC casing-capping of approved quality. (One RM shall consist of two wires.) The casing-capping shall be fixed on wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm. The work shall include supply, fixing, connection, testing and commissioning complete, as directed by the Engineer-in-Charge. | — | — | — | 98,230.38 | |
| — | 10.00 | — | — | ||
| Supply and wiring of wall bracket fan point through rigid PVC casing-capping with all necessary accessories for surface wiring using 1.5 sq.mm single core PVC insulated flexible copper conductor wire, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 5/6 Amp switch mounted on a hard plastic moulded board. The fan connection shall be made through a ceiling rose. The casing-capping shall be fixed on the wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 2,746.6 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 300 mm sweep wall bracket fan, suitable for 230 V, 50 Hz, single phase AC supply, complete with copper winding motor, ball bearings, powder coated metal body/blades and oscillation mechanism, conforming to relevant IS standards. The fan shall be securely mounted on wall with suitable bracket, clamps, fasteners and vibration-free arrangement. The work shall include proper electrical connection, earthing, testing and commissioning, along with supply of all necessary nuts, bolts, washers, clamps and other consumables for fixing, complete as required at site and as directed by the Engineer-in-Charge. | — | — | — | 8,519 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 2 KVA inverter system complete with 2 Nos. 150 Ah tubular batteries, battery trolley/stand and all accessories. The inverter shall generally conform to IS:13314, suitable for single phase input (120-260 V AC) and single phase pure sine wave output 230 V, 50 Hz. The system shall have minimum battery capacity of 8640 VAH and provide minimum backup time of 180 minutes, depending on load conditions. The tubular batteries shall conform to IS:13369 and be complete with interconnecting cables, terminals, electrolyte and protective covers. The work shall include supply, installation, proper wiring, earthing, testing and commissioning complete as required at site. Accepted Make/Brand: Luminous / Microtek / Exide / SF Sonic. Accepted Model: Microtek 2300 Heavy Duty Sine Wave or equivalent. The system shall be supplied with minimum one-year warranty from the date of commissioning. | — | — | — | 37,500 | |
| — | 15.00 | — | — | ||
| Supply, fitting and commissioning of 9 Watt LED bulb, B22/E27 type, suitable for 230 V, 50 Hz AC supply, conforming to relevant BIS standards, complete with all accessories and proper fixing in existing holder, including testing as directed by the Engineer-in-Charge. | — | — | — | 2,250 | |
| — | 30.00 | — | — | ||
| Supply of materials and wiring for modular type mobile charging point with mobile keeping tray, through concealed/surface wiring using 1.5 sq.mm single core PVC insulated FRLSH flexible copper conductor wire through PVC rigid conduit, with earth continuity by 1 sq.mm PVC insulated flexible copper wire. The point shall consist of 3 Nos. 6 Amp modular switches and 3 Nos. 6/10 Amp, 5-pin modular sockets, mounted on good quality modular plate and frame with suitable mounting box (minimum 3 mm thickness and 50 mm inside depth). The work shall include supply and fixing of all accessories such as PVC bends, tees, junction boxes, fasteners, mobile tray, proper termination, connection, testing and commissioning complete. Any damaged concealed surface during installation shall be restored and painted to match the existing surface colour, as directed by the Engineer-in-Charge. | — | — | — | 22,053.9 | |
| — | 1.00 | — | — | ||
| Supply and wiring of chimney power point with 15/16 Amp, 6-pin plug socket through rigid PVC casing-capping with all necessary accessories for surface wiring using 4 sq.mm single core PVC insulated flexible copper conductor cable, with earth continuity by 16 SWG bare copper wire. The point shall be controlled by a flush type 15/16 Amp switch mounted on a hard plastic moulded board. The casing-capping shall be fixed on wall/ceiling with MS screws (6x40 mm) at intervals not exceeding 300 mm, including all connections, accessories, testing and commissioning complete as directed by the Engineer-in-Charge. | — | — | — | 298.88 | |
| — | 1.00 | — | — | ||
| Supply of Frost Free Double Door Refrigerator conforming to IS:17550 / latest BIS standards, having minimum gross capacity of 380 litres, with BEE 5-Star energy rating, suitable for 230 V ±10%, 50 Hz single phase AC supply. The refrigerator shall be equipped with hermetically sealed high efficiency compressor, eco-friendly refrigerant (R600a or equivalent), toughened glass shelves, large vegetable storage compartment, door lock, LED internal lighting, stabilizer free operation and automatic defrosting system. The unit shall have separate freezer and refrigerator compartments, anti-bacterial gasket, temperature control thermostat, and corrosion resistant pre- coated steel body with high density PUF insulation for better thermal efficiency. The refrigerator shall be supplied complete with all standard accessories, power cord, plug top and user manual, with minimum one-year comprehensive warranty on the product and extended warranty on compressor as per manufacturer's standard terms. | — | — | — | 44,000 | |
| — | 10.00 | — | — | ||
| Supply and testing of 6 mtr. long GI Octagonal Pole complete with foundation bolts, loop box and accessories. The pole shall be fabricated from high strength steel sheet and hot dip galvanized in single dip as per relevant IS standards to ensure corrosion protection. The pole shall be supplied with bakelite loop box fitted with 6 Amp SP MCB and 16 sq.mm stud type connector, suitable for cable termination. Technical parameters of pole shall be as follows: Height: 6 m Top Diameter (A/F): 70 mm Bottom Diameter (A/F): 130 mm Sheet Thickness: 3 mm Base Plate Size (L x B x T): 200 x 200 x 12 mm Foundation Bolts: 4 Nos. x 20 mm dia Pitch Circle Diameter (PCD): 200 mm Bolt Length: 600 mm Projected Bolt Length: 100 mm The pole shall be supplied complete with base plate, foundation bolts, nuts, washers, loop box, MCB, connectors and all necessary accessories, tested and ready for installation as directed by the Engineer-in-Charge. | — | — | — | 1,30,000 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 1 mtr long GI single arm bracket (header) made of suitable GI pipe/section, hot dip galvanized, complete with lamp holder, nuts, bolts, washers and all fixing accessories. The bracket shall be securely mounted on the pole with proper clamping arrangement, complete in all respects as directed by the Engineer-in-Charge. | — | — | — | 20,000 | |
| Supply, installation, testing and commissioning of 45 Watt LED outdoor street light luminaire, suitable for 230 V, 50 Hz AC supply, with IP66 protection, system efficacy 105 lm/W, power factor 0.95 and THD <10%. The luminaire housing shall be pressure die-cast aluminium with powder coated finish, provided with heat resistant toughened glass cover, and inbuilt surge protection of minimum 5 kV. The fitting shall be complete with driver, connecting leads and all accessories, and shall be suitable for mounting on GI bracket/pole, ensuring uniform illumination for proper visibility during night conditions. The work shall include proper fixing, connection, testing and commissioning, complete as directed by the Engineer-in-Charge at site. | — | 10.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender doc
ATTACHMENT
Specification-2-3.pdf
ATTACHMENT
GCCACS1113.03.2026.pdf
ATTACHMENT
EL-LM-25-26-45-RT-works...pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .