Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.0 L+₹7.7 L (19.7%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹48.0 L+₹8.7 L (22.1%)Rejected-Finance 110 5 BONOMALI NASKAR ROAD BEHALA PARNASHREE PARNASHREE KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹48.0 L+₹8.7 L (22.2%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.0 L+₹9.7 L (24.8%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8004/B/E8
2021_MES_489376_1
GE/ALP (8004B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE ALIPORE KOLKATA
Class D and Category b (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹90,000
Yes
31 Jan 2022
20 Nov 2021
20 Dec 2021
20 Nov 2021
18 Dec 2021
4 Dec 2021
60 days
Amount
Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Crompton Cat No LST70CLD-M or equivalant in Phillips and Panasonic.
Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Crompton Cat No LSTP120-CDL-M or equivalant in Phillips and Panasonic.
Material and labour for replacement of thermoplastic cable junction box with knockouts for cable entry upto 25 sqmm including minimum 4 terminals for terminating cables (Cat No: K 9255 of make: Hensel or equivalent in make: Sintex) including fixing arrangement by carefully cutting the bases of pole or post top lantern or other wise as indicated including taking down old one complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing Steel tubular swaged poles complet with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres long) including taking down old pole complete all as specified and directed.
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make : Panasonic Cat No PFLM11708 or equivalant in Crompton and Phillips.
Labour only for checking of unserviceable street light fitting over poles, finding of faults and repair/ replacement of unserviceable spares like lamp, holder, ignitor, ballast, connector block etc and making the light functional in all respect including necessary tools required for repair all as specified and as directed. [Note: - (i) All the spares required for repair will be measured and paid under separate item of this schedule as 'Supply only'. (ii) Necessary tools required for repair deemed to be included in the quoted rate. (iii) Cost of short pieces of copper conductor for internal wiring in between holders, ballast, ignitors and other accessories housed in the same light fitting deemed to be included in the quoted rate]
All as per Item Ser No 6 above but for post top lanterns, outdoor bracket lights and flood lights
Supply only driver for LED luminaires upto 12 watt of make: Philips, driver type: BRP020 SPARE DRIVER 10LED 700mA 240V or equivalent in Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 24 watt of make: Philips, driver type: BRP320 POT Spare LED Driver or equivalent in Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 36 watt of make: Philips, driver type: BRP409 Spare LED Driver or equivalent in Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 75 watt of make: Philips, driver type: XITANIUM 75W 0.70A 1-10V INT-Y SXT or equivalent in Bajaj/ Crompton Greaves/ Havells.
Supply only driver for LED luminaires upto 150 watt of make: Philips, driver type: SPARE DRIVER XTE 150W 700 mA NTC or equivalent in Bajaj/ Crompton Greaves/ Havells.
Material and labour LED Post Top Lantern 40 watt for 360O indirect lighting with glare free milky white side covers and IP65 grade protection Cat No: LPTO-40-CDL/M of make: Crompton Greaves or equivalent in Philips/ Bajaj/ Havells including taking out of old light fitting all as specified and as directed.
Material and labour for Cement concrete in foundations, filling and mass concrete (1:3:6), type C2 (using 40 mm graded stone aggregate).
Material and labour for Cement concrete (1:2:4). type B1 (using 20 mm graded stone aggregate) in copping roof kerbs or mud stops, rounded or chamfered on edges
Material and labour for rendering 10 mm thick with cement plaster (1:6) on fair faces of brick work or concrete surfaces
Material and labour for Micro Rex analog time switch Programmed via capacity segment power supply 230 V 50Hz 3 position over rid switch ON AUTO OFF on front panel including taking down old one complete all as specified and as directed.
Cleaning roof top of MES Installations with wire brush including removing of vegetations and deposited silt from mouth of inlet/RWP and removing debrishes to out side of MoD land complete all as specified and as directed.
Cutting of bushes and removing all grass etc and cleaning of area in and around of E/M installations with satisfaction of Engineer-in-Charge and removing from site to out side of MoD land.
Servicing of Air Circuit Breaker AC three phase 415 volt, 50 Hz, 800 Amp to 1600 Amp including taking shut down and taking out the complete assembly, cleaning of all the parts by air blower, applying suitable chemical (CRC), greasing of all moving parts, checking resistance of all the contact points and refixing the same in original position and testing complete all as specified and as directed.
Taking out of old steel tubular pole of 9 mtr height and installing the pole in other location all as specified and as directed [Note: Earth work and PCC will be measured and paid under separet item of this schedule]
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ loose soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in any type of soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil
Material and Labour for dry river Sand filling in trenches including punning down consolidation complete all as specified and directed.
Material and Labour for tubes, 'medium grade', galvanised, with all fittings, laid in trenches for cable/ earth lead protection of the following sizes: -
(a) 80 mm dia nominal bore
(b) 50 mm dia nominal bore
(c) 40 mm dia nominal bore
Material and labour for brick protection of cables in trenches with old size sub-class 'B' bricks
Relaying of old useful bricks as retrieved during taking out of old LT UG cable all as specified and as directed.
Material and labour for cutting of existing bituminous metal road for laying of cables including demolition of road surface, excavation from bottom level of road upto a depth of 0.55 m from road surface and returning filling of excavated earth and making good the road surface with PCC type C2 (1:3:6) with 40 mm graded stone aggregate upto a depth of 10 cm from road surface and removing of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil all as specified and as directed. [Note: Laying of cable/ protection pipe will be measured and paid under separate item of this schedule]
Taking out of old LT UG cable 1100 volts grade all as specified and as directed for the following size of cables :-
(a) 400 sqmm 3.5 core and above
(b) 240 sqmm 3.5 core
(c) 185 sqmm 3.5 core
(d) 95 to 120 sqmm 3.5 core
(e) 50 sqmm 3.5 core
(f) 25 to 35 sqmm 3.5 core
(g) 10 to 16 sqmm 2/4 core
Supply and Laying XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade all as specified and as directed for the following size of cables: -
(a) 400 sqmm 3.5 core
(b) 240 sqmm 3.5 core
(c) 185 sqmm 3.5 core
(d) 120 sqmm 3.5 core
(e) 95 sqmm 3.5 core
(f) 50 sqmm 3.5 core
(g) 35 sqmm 3.5 core
(h) 25 sqmm 3.5 core
(j) 16 sqmm 4 core
(k) 10 sqmm 2 core
Material and labour for MCCB 4 pole, 415 V, 100 Amp, 36 kA Cat No: CM 9791900K20G of make: L&T or equivalent make as per list of make including taking out of old one all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 125 Amp, 36 kA Cat No: CM 9068100L00G of make: L&T or equivalent make as per list of make including taking out of old one all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 160 Amp, 25 kA Cat No: CM9063800NO including Spreader terminals Cat No: CM92007OOOO of make: L&T or equivalent in Legrand/ Schneider/ ABB including taking out of old one all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 250 Amp, 36kA Cat No: CM92151OOOOX1 of make: L&T or equivalent make as per list of make including taking out of old one all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 400 Amp, 36kA Cat No: CM93003OOOOX1 of make: L&T or equivalent make as per list of make including taking out of old one all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 63 Amp, 25 kA Cat No: Cat No:CM91712OOHOOG of make: L&T or equivalent in Legrand/ Schnieder/ ABB including taking out of old one all as specified and as directed.
Material and labour for MCCB Spreader Terminals 2 Pole Cat No: Cat No:CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB including taking out of old one all as specified and as directed.
Material and labour for MCCB Spreader Terminals 3 Pole Cat No: Cat No:CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB including taking out of old one all as specified and as directed.
Material and labour for MCCB Spreader Terminals 4 Pole Cat No: Cat No:CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB including taking out of old one all as specified and as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 90 sqmm
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
M & L for Mild steel plates, chequered, 5mm thick or over in thickness in available sizes for use as duct covers as per existing size including taking out of old one all as specified and as directed.
Repair and maintenance of LT distribution panel after taking proper shutdown including cleaning of enclosure with dry cloth and cleaning of contact points with suitable electrical contact cleaning agent and clean dry cloth, checking of tightness of all the contact points, replacement of defective/ burnt out lugs and bolts & nuts and reporting of major defects if any found during maintenence all as specified and as directed for the following: -
(a) LT panel with Incoming ACB upto 1600 Amp 1 No and outgoing MCCBs upto 630 Amp 4 pole upto 8 Nos and Change over if any
(b) LT panel with Incoming MCCB upto 800 Amp 1 No and outgoing MCCBs upto 400 Amp 4 pole upto 8 Nos, all MCBs, Change over if any
(c) LT feeder pillar box with Incoming MCCB upto 400 Amp 1 No and outgoing MCCBs upto 250 Amp 4 pole upto 8 Nos and all MCBs
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 32x6mm galvanised iron strip including taking out of old strip all as specified and as directed.
Material and Labour for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw including taking out of old one all as specified and as directed.
Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4), type B1 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia M.S. round bar including necessary earth work in excavation, in soft/loose soil returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
All as per item No 48 above but with GI wire of 4mm dia as earthing lead
S&F cable Iugs,aluminum tubular as per following :
(a) 240 sqmm
(b) 185 sqmm
( c) 120 sqmm
(d) 95 sqmm
(e) 70 Sqmm
(f) 50 Sq mm
(g) 35 sqmm
(h) 25 sqmm
(j) 16 sqmm
Material and labour for Painting of LT Pole after preparation of old painted surface and painting with one coat of aluminium paint for the entire pole and yellow and black colour synthetic enamel paint in 2 Nos alternate layers of 32 mm high at the bottom of each pole including taking proper precautionary measure for disconnecting electric supply all as specified and as directed.
Material and labour for Painting of pipes of Post Top Lanterns after preparation of old painted surface and painting with one coat of synthetic enamel paint of approved colour including taking proper precautionary measure for disconnecting electric supply all as specified and as directed.
Material and labour for Painting of LT Panel after preparation of old painted surface and painting with two coats synthetic enamel paint With spray painting of approved colour including taking proper precautionary measure for disconnecting electric supply all as specified and as directed.
MS AP CONSTRUTION AND CO
S B ENTERPRISE
Tirupati Buildcon Pvt. Ltd.
KWALITY CONSTRUCTION
EASTERN REFRIGERATION AND ELECTRICAL CO
ELECTRO FREEZE
JAIN CONSTRUCTION AND ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .