Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAccepted-AOC | ₹11.1 Cr | L1 | Accepted-AOC Lowest and Reasonable Tender |
| 2 | L2₹12.2 CrRejected-Finance | ₹12.2 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹12.9 CrRejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | ₹12.9 Cr | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹9.2 L
Closing Date
9 Feb 2021, 6:00 pmClosed
CE AandN ZONE
CE AN ZONE Birchgunj Port Blair
AUGMENTATION OF INFRASTRUCTURE AT HUT BAY AND PROVISION OF OTM ACCOMODATION Tender
2020_MES_402689_1
801056/E8
Open Tender
Civil Works
750 days
HUTBAY
10 documents required · 10 mandatory
₹3,000
₹9.2 L
Yes
18 Mar 2021
12 Dec 2020
12 Feb 2021
13 Dec 2020
9 Feb 2021
25 Jan 2021
13 Dec 2020 - 19 Dec 2020
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to X are prepriced by MES under Ser No. 2.00 to 11.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for "Building / Structures” as listed in Schedule ‘A’ Part - I, inserted by MES
Lumpsum price worked out by the tenderer for "Internal Water Supply " as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for "Internal Electrification " as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for "Sewage Disposal " as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "Area Drainage" as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for "RCC Culvert" as listed in Schedule 'A' Part-VI
Lumpsum price worked out by the tenderer for "PCC Road" as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for "Security wall, Fencing and Steel gate " as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-X
Subtotal
SCH 'A' PART XI MISCELLANEOUS ITEMS NOTE: Schedule ‘A’ Part - XI is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
Internal Electrification : Supply & fix Ceiling fan, 5 star rating suitable for working of AC 230V, 50 Hz, 1200 mm sweep with electronic regulator, down rod and canopy rating and the color of milky white including anchor flusher, ceiling hookfor fixing of fan on celing complete all as specified and directed by Engr-in-charge. Make: Bajaj/Havells/CG
Supply & fix exhaust fan, 225mm sweep,sigle phase, AC 230V, 50 Hz, heavy duty,1400 rpm energy efficient smooth functioning with suitable size of louvers including fixing arrangement, opening of whole all as directed by Engr-in-charge. Make: Crompton/Bajaj/Usha
S&F LED type tube light fittings, 4 feet long, 1x20 watts, 230V, decorative ultra slim squar profile liner LED lighting fixture with extruded polycarbonate envoirement friendly, energy efficient tube light, voltage protection 160-360V, power factor >0.9 complete & prewired for LED tube complete fixed to wall/ceiling by suitable down ods, PVC round block and connection by flexible PVC cable with stranded copper conductor from ceiling rose to connector of the fitting including 1x20W LED tube complete all as specified and directed.
S&F 10 watt LED fittings with syrge protection of 2 KV with wide voltage protection 160-360V, lumen output 900lm complete & prewired for LED tube complete fixed to wall/ceiling by suitable downrods, PVC round block and connection by flexible PVC cable with stranded copper conductor from ceiling rose to connector of the fitting complete all as specified and directed. Philips Cat No-BN010C LED 20S PSU CW GR S1/Wipro/Crompton
S & F building street light LED fitting 30 W capacity including electronic driver IP 65 peotection, fixing with suitable size of brackets 1.2 mtr long bend to shape, including clamp nut and bolt, connected from ceiling rose or existing point all as specified and directed by Engr-in-Charge. Philips Cat No-BRP046LED 30CWMRS1 PSU GR /Wipro/Crompton
S & F miniature circuit breaker(RCBO/MCBs/MCCBs) of following capacity.
MCB SP 10 KA, 6 to 32Amps, 'C' curve.
MCB SPN 10 KA, 6 to 32Amps, 'C' curve.
RCBO 2 pole, 230volts, 10KA, 6 to 32 Amps.
S & F TV socket/Telephone socket complete all as specified and directed.
Security wall & Fencing: Supply and fixing punch type concertina coil of 600mm round type, 51 spirals, core wire, high tesile steel wire galvanised as specified in IS-4454 including necessary wire for fixing coil on security/compound wall Y shape MS angle as specified.
S &F PVC coated mild steel angles, flats etc(PVC Coatednot less than 0.70mm thick) as in supports for posts, struts in fencing incl. cutting tops to shape as directed, drillin holes, notching for wire, flat iron fillets, (for securing wire mesh) including all necessary drilling, bolting and similar work confirming to Fe 290Gde E-165 complete all as specified and directed.
S &F PVC coated mild steel round bars, 10mm dia (PVC Coatednot less than 0.70mm thick) as in straining bars conforming toGde-I IS-432, cut to length, bent to shape required and fixing all as specified and directed.
Supply only PVC coared GI chain link mesh of size 50 x 50mm 3.6mm dia GI wire with 1mm thick PVC coating complete all as specified.
EXTERNAL WATER SUPPLY: M &L for Construction of masonry valve chamber of size 600x600x600mm internal size, 100mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4m, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement, 3.15mm thick MS sheet cover including 50mmx50mmx6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmx6mm flat iron hold fasts, handle, hinges with locking arrangments, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to distance not exceeding 50M complete all as specified and directed.
Supply , testing and commissioning of monoblock pump set of discharge cap 4.7 Liters per second at head 44 mtrs complete, 3000 RPM, coupled with and including induction motor of 3 phase, 415 Volts, 50 Hz of suitable capacity, mounted on MS Channel/Common Base plate and fixed with suitable bolts, grouted in PCC foundation/platform, PVC insulated single core unsheathed copper conductor of 6 Sqmm size drawn in GI pipe medium grades for connecion from Starter to Motor terminal and also including the follwoing acessories/compenents :- i) Brass Foot Valve - 1 No of Size Suitable for Suction of Pump ii) Gun Metal Butterfly Gate Valve - 1 Nos Size Suitable for Devlivery of Pump iii) Gun Metal Non Return Valve - 1 Nos Size Suitable for Devlivery of Pump iv) Suction Pipe - 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) of dia as specified by Manufacturer upto a length of 9 meters including all PP-R fittings. v) Burden type pressure gauge on delivery of Pump set - 1 No vi) Interconnection of Delivery mains of pumps by providing 3 layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) of dia as specified by Manufactures including all PP-R fittings
M &L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directlry in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanized earth strip 32 x 6mm , earth plate surrounded from all sides by with 15cm thick packed layer of charcoal dust and common salt filling in alternate layer and electrode connection by using galvanized earth strip 32x6mm connected by mean of bolt, nut, chck nut & washer of galvanised iron, provision of 40mm dia GI pipe medium grade for protection of gi strip & 20mm dia GI pipe medium garde for watering arrangement and PCC (1:3:6), type C1 chamber, msfunnel, wire gauge, 50mm thick RCC 1:2:4 TMT bars on both ways including necessary excavation in any type o soil returning filling in removal of surplues soil to distance n.exc 50 mtrs complete all as shown in electrical plat no 5 of schedule part-I 2009 all as specified and directed.
Supply, installation, testing and commissioning indoor cubical wall mounted type LT motor starter panel Panel suitable for 3 phase, 4 wire, 415 volts 50 Hz supply system witj suitable size and powder coated, dust/vermin proof. The panel shall CPRI approved factory fabricated made with 2mm thick CRCA sheet for outer shell and inner shell made out of 1.6mm thick CRCA sheet, double door with front openable with locking arrangements, provision of thereaded earthing stud at bottom, inner shell shall be compartmentalized fron openable single door lockable to accommodate incoming/outgoing MCCB/MCBs, motor starter danger notice plate having conventional symbol of bone and skull be provided. Including wall mounting fastners. The panel shall consist of the following accessories:- (a) MCCB TP 40 \Amps, 415 Volts 25 KA -1 No. (b) MCB TP 32 amps, 415 Volts 10 KA - 2 Nos. (c) MCB SPN 20 Amps 230 Volts 10 KA - 1 No. (d) RYB Panel Indicators - 3 Nos. (e) DOL Starter for 7.5 HP Pump set including ON/OFF push button, Pump ON/OFF Indicator - 2 Nos. (f) Digital Voltage, Ammeter, frequency & PF meter 3 phase 440 volts including CTs - 1 No.
EXTERNAL ELECRIFICATION: Supply, install , testing and commissioning of approved OEM factory,assembled diesel generator set of totally enclosed and sound proof (with acoustic enclosure) of capacity - 100 KVA, 3 phase, 4 wire, 415 volts, 1500 RPM, AC power supply with power factor 0.8, coupled directly to alternator mounted on common base plate complete with fuel tank, battery and standared accessories and fittings, vibration pads, PCC foundation complete all as specified and directed. The genset shall conform to CPCB norms for noise and emission limits and including the following :-
(a) Alternator:- Standard design alternator rated at 100 KVA net output at site after considering all derating factors, site conditions and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 RPM, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design, insulating class H, voltage regulation +/- 1% operated voltage from no load to full load and shall be in position to generate supply with frequency regulation within +/- 3% tolerance, revolving field type. (b) DIESEL ENGINE :- Adequate capacity diesel engine suitable to above alternator, raditor water cooled, to drive independently above alternator and after considering derating as per site conditions directly coupled to alternator multicylinder,multistrocke, direct injection cold starting, 1500 RPM, with an overload cap of 10% for 1 hour in any 12 hours continuoun running complete with standard accessories all as specified and requied for safe running anf opeation with accessories shall be as under :- (i) Flywheel (ii) Air cleaner wet/dry type (iii) fuel Filter (iv) Fuel Injection system incl. injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter (vi) Lubricating oil pump (vii) Turbocharger (viii) Raditor (ix) 12 volts staring system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/generator with regulator starter motor, starter gear (x) Exhaust silencer complete with exhaust pipe of suitable dia. (xi) Microprocessor control electronic metering and module for indication of battery voltage, oil pressure, engine RPM, hour meter and protection against low oil pressure and over speed of engine including electronic governing. (xii) Battery charging system with suitable capacitybattery charger complete with necessary connecting leads etc all as directed (xiii) Radiator cooling system comprising of radiator, radiator fan belt. (xiv) Fuel Hoses (xv) Inbuilt fuel tank of 10 h\Hrs run of full load capacity of DG set. (xvi) Air intake system (xvii)Common base frame of sturdy design suitable for antivibration mounting and permament concrete foundation for mounting engine and alternator as per manufacturer's instructions. (xviii) Extension of exhaust silencer complete with exhaust pipe of suitable dia from out side canopy to out side of building /shedall covered with glass wool wrapped with aluminium foil f 28 SWG adequate to create draft for safe exhaust without without transering vibrations to buildings/walls, flxible exhaust pipe complete.
(e) Acoustic Enclusure- (i) Composite type made of CRCA sheet and structural/sheet metal base frame duly painted with air inlet louvers, including noise absorbant and fire-retardant grade acoustic insulation material, including removeable gland plate at lower level fo canopy for cable entry. (ii) The drg and specificatins of the DG set & AMF Panel shall be got approved by the contractor from the accepting officer before procurement. (iii) The DG set after installation shal be got tested at site by the rep nominated by the Accepting Officer and the records of the testing shall be signed by the Rep of Accepting Officer, GE, Engr-in-Charge and the contractor. (iv) Disel, grease, engine oil, load bank and testing equipments required for testing shall be provided by the contractor and cost of the same shall be deemed to tbe included in the contractor's qouted rates.
Supply errect and fixing pre-cast RCC pole, M-30 design mix 11m long of croos section 380mmX250mm at bottom and 150x125mm at top including reinforcement with high strenght deformed steel TMT bars and necessary form workand errecting in position all as specified and as directed. (a) The rate deemed to include the following provision also :- (i) Excavtion in any type of soil, returning filling and removal of surplus soil to a distance of 50m (ii) Foundation in PCC (1:4:8) type D-2 using 40mm graded stone aggregate. (iii) Coping in PCC (1:3:6) type C -1 using 20mm graded aggregate.
Supply and fix street light fittings in street light poles/Buildings, fittings shall be of LED type 45 watts complete with and including drivers pressure die cast aluminium housing, prewired complete. The fitting shall coform to cat No. LSTS-45-CDL-M of crompton or equivalent fron Phillips/Bajaj.
M & L for 3 core 1.5 sqmm size multistranded copper conductor PVC unsheathed 1100 volts grade and including passing through pole, copper lugs all for interconnection of cable junction box to street light fitting etc. all as directed.
S & F sheet moulidng compound (SMC) type junction/looping box for street light fitting with hinged type door of size 250x200x105mm with MCB SP 6 Amos 01 No, includingheavy duty terminal block 3 phase 4 wire system of 63 Amp capacity.
Supply and fix HDGI Octagonal pole 7 meter height having top dia 70mm and bottom dia 135mm and thickness 3mm, including heavy duty GI pile bracket with nuts & bolts 4 Nos 'J' type foundation bolts of dia 16mm and 450mm long with base plate. Note :- PCC/RCC foundation will be measured seperately under respective items.
Excavation in post holes not exceeding 0.5 cum for errection of poles, removing the excavated materials to a distance 50 meter and providing PCC bed and RCC foundation as per following including formwork. (i) PCC bed - 450mm x450mm x 100mm (ii) Rcc column - 400mm X400mm x 1300mm, M-20 Design mix, using 4 Nos 12mm dia bar
Supply & fix 150 watts high beam revolving serch light - LED, energy saving long range narrow beam, IP 66, with manually operated CS stand, suitable for mounting of serch light on railing/ Platform of watch tower or other plain surface, made of both locking arrangement at desired position. Make: kalin Cat No. CS-LRFLL25-PC 15 or equivalent in Phillips/Luker.
Supply, installation, testing and commissioning indoor cubical LT feeder distribution panel suitable for 3 phase, 4 wire, 415 volts 50 Hz supply system with suitable size and power coated, dust/vermin proof. The panel shall CPRI approved factory fabricated made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thraded earthing stud at bottom, inner shell shall be compartmemtalized front openable single door lockable, inner shell shall be completely vermin proof and to accommodate incoming /outgoing MCCB, MCBs, change over switch and TPN aluminium bus bar and extensions link of rating not less than 1.5 times the rated capacity of the respective MCBs. the TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy resin insulator. The MCCB shall be provided with copper spreader link of suitable rating. All control wires shall be with 2.5 sqmm multistranded copper conductor wire and shall be properly bunched, tied ferruled for proper indentification and crimped with suitablesize of lugs.
The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground, danger notice plate having conventional symbol of bone and skull be provided icluding PCC foundation, excavation, groting bolts.the panel shall consists of the following accessories:- Note: The layout diagram of the panel shall be got approved by the contrctor from GE before febrication. a) MCCB 4 pole 415 Volts, 35KA, 200 Amps 1 No ( Incoming) b) RYB panel indicators - 3 Nos (c) Trivector energy meter three phase four wire TVM 240 Volts, 5A class 0.5 including wiring & CT - 1 Set
Supply, installation, testing and commissioning outdoor cubical LT feeder distribution panel suitable for 3 phase, 4 wire, 415 volts 50 Hz supply system with suitable size and power coated, dust/vermin proof. The panel shall CPRI approved factory fabricated made with 2mm thick CRCA sheet for outer shell and inner shell made out of 1.6mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thraded earthing stud at bottom, inner shell shall be compartmemtalized front openable single door lockable, inner shell shall be completely vermin proof and to accommodate incoming /outgoing MCCB, MCBs, change over switch and TPN aluminium bus bar and extensions link of rating not less than 1.5 times the rated capacity of the respective MCBs. the TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy resin insulator. The MCCB shall be provided with copper spreader link of suitable rating. All control wires shall be with 2.5 sqmm multistranded copper conductor wire and shall be properly bunched, tied ferruled for proper indentification and crimped with suitablesize of lugs.
Supply, installation, testing and commissioning outdoor cubical LT feeder distribution panel suitable for 3 phase, 4 wire, 415 volts 50 Hz supply system with suitable size and power coated, dust/vermin proof. The panel shall CPRI approved factory fabricated made with 3.15mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thraded earthing stud at bottom, inner shell shall be compartmemtalized front openable single door lockable, inner shell shall be completely vermin proof and to accommodate incoming /outgoing MCCB, MCBs, change over switch and TPN aluminium bus bar and extensions link of rating not less than 1.5 times the rated capacity of the respective MCBs. the TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy resin insulator. The MCCB shall be provided with copper spreader link of suitable rating. All control wires shall be with 2.5 sqmm multistranded copper conductor wire and shall be properly bunched, tied ferruled for proper indentification and crimped with suitablesize of lugs.
M & L for Cable route indicator, conisting of cast iron round shape 200mm dia, 6mm thick with inscription casting as HT cable 11000 Volts grade and fixed with hot dipped GI angle iron of size 40x40x6mm thick 0.8 mtr long with GI nut bolts embeded to ground in route of cable with the help of PCC 1:3:6 type C-2 complete.
M & L for Cable route indicator, conisting of cast iron round shape 200mm dia, 6mm thick with inscription casting as LT cable 1100 Volts grade and fixed with hot dipped GI angle iron of size 40x40x6mm thick 0.8 mtr long with GI nut bolts embeded to ground in route of cable with the help of PCC 1:3:6 type C-2 complete.
Subtotal
SACKSON ENTERPRISES
ASHOK BISWAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid