| 1 | L-1₹30.2 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.8 L+₹1.4 L (4.42%)Rejected-Finance | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹32.9 L+₹1.5 L (4.67%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹34.5 L+₹3.1 L (9.89%)Rejected-Finance | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹35.1 L+₹3.7 L (11.8%)Rejected-Finance R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
15 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS, C/O 56 APO
SPECIAL REPAIR TO BLDG NO P 104 AT KHUNMOH GRN UNDER GE 861 EWS
2023_MES_581024_1
GE 861 EWS-71/2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹92,000
Yes
1 Apr 2023
14 Feb 2023
22 Mar 2023
14 Feb 2023
15 Mar 2023
1 Mar 2023
Amount
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specified and directed.
Demolition wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets & snap grid frame etc, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar, complete all as specified and directed..
Dismantling water tanks of any description exc 250 Ltrs not exc. 500 Ltrs capacity and removing to storecomplete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
5mm thick rendering on fair faces as in ceiling/landing etc. of brick work or concrete surfaces in CM 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
25mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
75mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
Non-skid coloured joint free ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Non-skid coloured joint free ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Glazed ceramic coloured tiles 450mm x 300mm x 7-8mm thick, designer & pattern(dark & light shade combination) as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed.
Chequered coloured cement concrete tiles of size 200 x 200 x 25mm thick, glossy finished, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
18-20mm thick machine cut granite (of any type) tiles, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
18-20mm thick machine cut granite (of any type) tiles in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and 10mm thick backing coat in cement mortar 1:3, complete all as specified and directed.
Machine cut kota stone slab flooring 18-20mm thick of size not less than 0.30sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. NOTE: Single piece tiles will be placed on the surface of stair case tread area.
Machine cut kota stone slab 18-20mm thick in riser of steps, riser of staircase, skirting, dado and pillar laid over cement screed and jointed and including 10mm thick backing coat in cement mortar 1:3 to receive, complete all as specified and directed. NOTE: Single piece tiles will be placed on the surface of stair case riser area.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including one shop coat of red oxide primer, complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
Pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., supplied and fixed, complete all as specified and directed.
Pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., supplied and fixed, complete all as specified and directed.
Pressed steel shutter (cupboard shutter), 1mm thick including pressed steel frame of 1.25mm thick sheet, 12mm dia MS rod for locking 02 Nos of chromium plated handle and 01 godrej pattern lock including two coats of spray painting over a shop coat of primer (overall size not less than 1.95sqm and not exc. 2.10sqm), complete all as specified and directed.
Factory made steel windows/ventilators (box type) with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of red oxide primer and making good disturbed surfaces of walls, complete all as specified and directed. NOTES: (a) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide primer on steel windows and nothing shall be extra paid in this account. (b) Detail of box window shall be given on drawing No. TD/2013/01 sheet No. 1/3 to 3/3. (c) Glass panel/wire gauze shall be measured and paid separately.
Factory made steel windows/ventilators (box type) with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat of red oxide primer and making good disturbed surfaces of walls, complete all as specified and directed. NOTES: (a) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide primer on steel windows and nothing shall be extra paid in this account. (b) Detail of box window shall be given on drawing No. TD/2013/01 sheet No. 1/3 to 3/3. (c) Glass panel/wire gauze shall be measured and paid separately.
Anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including Hangers 6 mm dia MS rod (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed.
10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false celing grid made of aluminim GI/MS as per specification and drawing, complete all as specified and directed.
S&F in repair 2nd class hardwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plaind steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall and eave boards fixed with self tapping screws, complete all as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
200mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
4mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
4mm thick figured glass pin headed type and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S & F in repair 300mm long mild steel ordinary rat tail rod pattern, springs including roller and roller plate fixed, complete all as specified and directed.
S & F in repairs stainless steel curtain rod 25mm dia, fancy type, SS bracket, knobs, rings @ 10cm c/c etc., all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm & fixed with stainless steel wire staples, complete all as specified and directed.
Steel water tubing, 15mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
All as per the description of item No. 51 here-in- before but except tubing.
Steel water tubing, 20mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
All as per the description of item No. 53 here-in- before but except tubing.
Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball, complete all as specified and directed.
S&F in repairs vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, jointing to flush pipe including lime concrete bedding and all joint making good to the floor, complete all as specified and directed.
S&F in repair grating doom 125 mm dia with waste hole of PTMT (minimum weight not less 40grms), complete all as specified and directed.
S & F in repair for 125mm size brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm dia or union, complete all as specified.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets (fixed in repair), complete all as specified and directed.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repair 15mm bore bib tap, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S&F in repair 15 mm bore brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixeds, complete all as specified and directed.
S & F in repair 15mm bore stop valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repairs towel Rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and directed.
S&F in repairs 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
S&F in repairs 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
110mm bore dia PVC (SWR) bends, complete all as specified and directed.
75mm bore dia PVC (SWR) bends, complete all as specified and directed.
Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore pipe, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying two coats of cement base paint, complete all as specified and directed.
Preparation of new plastered surfaces of wall to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation of old surfaces of walls, plastered or unplastered including brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil bound distemper over a coat of primer and 3mm thick wall care putty on wall, complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of old painted wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint to match the existing surface, complete all as specified and directed.
Preparation of old decorated CGI sheet surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint (camoflauge pattern) complete all as specified.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
Complete removal of existing treatment of ceiling and applying two coats of white wash, complete all as specified and directed.
Preparation of old surfaces of ceiling, plastered or unplastered including brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying two coats of white wash, complete all as specified and directed.
M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed:- (i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-1. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound sika plastocreat plus or equivalent make in Fosroc/ Thremax as approved by GE @ 0.2% by wt of cement consumed. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc/ Thremax as approved by GE. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc/ Thremax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement: Sika Fab-1 or equivalent. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc/Thremax as approved by GE @ 0.2% by wt of cement consumed. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. (viii) The sunken floor shall be filled with lean concrete 1:7:12. Note:- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Concealed point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-84 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-84 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No-84 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Bell push, flush type, 6 Amp, complete all as specified and directed.
Call bell , ding dong AC single phase, 230 volts 50 Hz including wooden/ PVC board of suitable size, connecting and testing, complete all as specified and directed.
Stepped type electronic fan regulator flush type, AC 230 volts, duly ISI marked including connector on the existing sheet etc. as reqd., complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
LED lamp 7 W, pin type, complete all as specified and directed.
S&F in repair new generation wall/surface mounted 18W LED batten fitting, 4 feet, surface mounted provides high quality economic energy saving lighting complete with all accessories, internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S&F in repair new generation wall/surface mounted 10W LED batten fitting, 4 feet, surface mounted provides high quality economic energy saving lighting complete with all accessories, internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 & IK-09 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "B" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 10sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 10sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 95 sqmm nominal cross section 3.50 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
S&F in repair 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 sqmm nominal cross section 4.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Supply and laying in repairs 40mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Supply, fabrication, installation, testing & commissioning of LT feeder piller panel, outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, 3 phase 4 wire 50 Hz AC, front & back openable doors having copper bus bar of capacity 300 amps for phases anf 150 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc including taking out old feeder pillar panel, complete all as directed and suitable to accommodate the following switch gears and meters:- (a) MCCB 4 Pole, 200 Amps, 25 KA, thermal magnetic - 01 Nos (Incoming) (b) MCCB 4 Pole, 63 Amps, 16 KA, thermal magnetic - 05 Nos (Out going) (c) Volt meter , digital type ,0 - 500V - 1 No (d) Ammeter, digital type with CT's - 1 No (e) Indication lamps (R,Y,B) LED type - 1 set
Supply and fabricate, installation, connection and commissioning of junction box, fabricated with 2.0mm thick made of CRCA sheet, powder coated , CPRI Approved, front door openable including earth bars, cement spill protected cable ties, blanking plates, copper bus bar 200 Amp rating with colour coded heat shrinkable sleeve TPN complete including taking down out old unsv junction box and suitable to accommodate the following accessories:- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 16 KA - 01 No (Incoming) (b) MCB, SPN 40 Amps, 10 KA - 06 No. (Outgoing) (c) MCB, SP 6 Amps, 10 KA - 02 No. (Outgoing) (d) Multifunction Meter- 1 No. (e) Phase indication LED lamps (R,Y,B) - 1 set. (f) Copper bus bar 200 Amps rating with colour coded heat shrinkable sleeve TPN- 01 set. NOTE:- (i) Junction box shall be flush in staircase wall & at adequate height. (ii) Cement work, plaster work & painting with existing colour is inclusive of rate and nothing extra will be paid.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in the ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc. as required having size 4mm galvanised iron or steel wire, complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 25x4mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long copper strip of size 25x4mm with protection pipe of 20mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by -24.0%(Minus) (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M/S SMYLE AND CO
M/S SHEIKH FEROOZ AHMAD
M/S A Q ENTERPRISES
M/S LATIF AHMAD BABA CONSTRUCTION
M/S Hilal Builders
SAMEER CONSTRUCTIONS
FIRDOUS AHMAD BABA
M/S Tajamul Ah Buchh
M/S RASHID CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .