Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.1 LAccepted-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L-1 | Accepted-AOC Deposited performance security money | |
| 2 | Rejected-Technical AT KARGALI BAZAR PO BERMO DIST BOKARO PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Not Evaluated | |
| 3 | Rejected-Technical AT BALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical Not Evaluated |
Tender Value
₹18.5 L
EMD Value
₹23,100
Closing Date
5 Mar 2024, 11:00 amClosed
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand
Repairing and reorganization of cabling system for comprehensive outdoor illumination system of IWSP including reorganization n repairing of valves with painting n numbering along with cable jointing for leakage free n safe electrical supply for trou
2024_CCL_302241_5
SO(EnM)/e-tender/23-24/34
Open Tender
Electrical and Maintenance Works
Item Rate
18 days
IWSP
As per NIT
2 documents required · 2 mandatory
₹23,100
26 Jul 2024
23 Feb 2024
6 Mar 2024
23 Feb 2024
5 Mar 2024
24 Feb 2024
23 Feb 2024 - 1 Mar 2024
Amount
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ‘’C’’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole & neutral.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). : 2 + 4 way/ 6 way, double door.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and re-filling the trench etc. as required, but excluding sand cushioning and protective covering. : upto 35sq.mm
Dismantling of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct from ground including excavation and re-filling the trench etc. as required, but excluding sand cushioning and protective covering. : upto 35sq.mm
Supplying and fixing of following sizes of medium class PVC conduit, along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. : 40 mm
Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 2 x 2.5 sq.mm
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 2 x16 sq.mm
Supply and fixing of bend pipe.
Clamp
Supply and fixing nut & bolts.
Fitting and fixing of light.
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand).
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement : 4 fine sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) for cable.
Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand).
Carriage of materials by mechanical transport including loading, unloading and stacking : Earth as per lead upto 1KM.
12mm cement plaster of mix 1:6 (1 cement : 6 fine sand).
Total impact of GST for the purpose of CTC
M/S UPENDRA ELECTRICAL
M/S A N TRADERS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_313217.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .