Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹38.7 L+₹41,463.40 (1.08%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹40.9 L+₹2.6 L (6.69%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹41.0 L+₹2.6 L (6.88%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹41.4 L+₹3.1 L (8.14%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
22 Apr 2024, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
UPGRADATION OF E/M INFRASTRUCTURE AT JAGDISH CHAND AUDITORIUM AT AF STATION PATHANKOT
2024_MES_642391_1
CWEAFJ-35/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
As Per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Pathankot
₹87,400
Yes
24 Jun 2024
14 Feb 2024
24 Apr 2024
14 Feb 2024
22 Apr 2024
8 Apr 2024
Amount
S&F installation testing and commisioning of LT electric panel board totally enclosed (Factory, Fabricated), Outdoor type double door type powder coated inside & outside made out of CRCA sheet not less than 3.15 mm thick with front opening having locking arrangement spray painting internally/externally, including internal wiring with suitable size of Aluminium strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of Aluminium bus bar of capacity 630 Amps inclulding making connections from existing system and consisting of the following:- (a) MCCB FP 630 Amp 50 KA with adjustable thermal and magnetic setting -01 No (Incomming) (b) MCCB TP 250 Amp 35 KA with adjustable thermal and magnetic setting -02 Nos (c) MCCB TP 200 Amp 25 KA with adjustable thermal and magnetic setting -02 Nos (d) MCCB TP 160 Amp 25 KA with adjustable thermal and magnetic setting-02 Nos (e) Digital Multifunctional metershowing reading of Voltage, current, PF, Frequency, KVAr, KWH of size 96 x 96mm, (f) Indicator lamp with Holder 03 Nos-One set.
Supply, installing, testing and commissioning outdoor type floor mounted Step up/down transformer, 11KV/433 Volts (at no load) AC 3 Phase 50 Hz, 315 KVA Capacity, core type, double copper wound oil immersed, Oil Natural- Air Natural (ONAN) cooled, with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with Neutral brought out on secondary side (LV Side) and having tapings at 2.5% and ± 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45°C in oil and 55°C in HV/ LV winding when measured by resistance method after continuous full load run on an ambient temp of 40°C. The transformer shall be as per IS 1180 EE Level-2 standards and shall comprise of the following:-
(a) Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nut and washers, with cable glands suitable for reception/ taking out of 03 Nos single core 300 Sq mm and one No single core 100 Sqmm, LT 1100 volts grade XLPE insulated and sheathed, heavy duty, armoured cables including joints and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel) (e) Exposive vent, Thermometer pocket on tank cover, Oil level guage, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, Air release valve plug and four Nos. plain solid vast steel detachable rollers
(f) One No 100 mm dia, dial type thermometer, vapour pressure release type having range 0-200º C with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50X6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First filling of new and unused transformer oil, IS-335 marked (Make: Savita/ Power Link) filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes.
Construction of Platform with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class "B" old size brick, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc of size 3000mm x 2500mm x 1200mm with fencing foldable upto 1.5m height, gate with locking arrangements using GI wire mesh, GI wire 4mm dia, angle iron, MS plate etc, complete all as specified and shown in drawing No. CEPZ/ TD-504
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 240 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 185 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 120 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 50 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
OCTAGONAL pole 07 mtr height, type BOP-7030 ,Top dia 70 mm,bottom dia 130mm,sheet thickness 03mm and base plate dimention 200x200x12 mm, bolt dia 4x20 dia, Pitch circle dia 200mm, Bolt length 600 mm, Procted bolt length 100 mm ,screw including all fixing arrangement as per requirement at site all as specified and directed by Engr-in-charge.
Foundation bolt of size 4x20 dia 200x600x100 mm for OCTAGONAL pole including fixing arrangement all as specified and directed.
Single arms bracket 01 mtr long for pole having 70 mm A/F for OCTAGONAL pole including fixing arrangement all as specified and directed.
Double arms bracket 01 mtr long for pole having 70 mm A/F for OCTAGONAL pole including fixing arrangement all as specified and directed.
Sleek junction box with one 06Amps SP MCB and 16 sqmm stud type connector for single arms bracket for OCTAGONAL pole including fixing arrangement all as specified and directed.
Sleek junction box with one 06Amps SP MCB and 16 sqmm stud type connector for double arms bracket for OCTAGONAL pole including fixing arrangement all as specified and directed.
LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with act and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 2 Core x 16 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 4 Core x 25 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. Notes ' : The Contractor shall take due precaution while excavation for not damaging existing Water Supply Lines, Electrical and Communication Cables etc. any damage occured to the same during excavation shall be made good by contractor without any extra cost to the department
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) for foundation of poles / stays etc complete all as specified
PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping including necessary form work finishing the cement concrete surfaces even & smooth using extra cement complete all as specified.
Disconnecting Electrical connection of HT cable from the existing transformer, and refixing the same with required nuts, bolt at new transformer all as required at site specified and directed by Engr-in-charge.
Point wiring for one light point controlled by one switch with 1.5 Sqmm PVC insulated and unsheathed FRLs copper conductor single core multi stranded flexible copper cable 1100 volts grade conforming to IS-694 using approved colour code as per IS code drawn through non metalic rigid PVC heavy duty conduit in concealed (min 20mm dia external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size for fixing of modular switches/sockets /regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as continuous earth lead wire connected to common earth and earth dolly completed all as specified and directed by Engineer-in-Charge.
Point wiring for one fan/exhaust fan point controlled by one switch and one regulator with 1.5 Sqmm PVC insulated and unsheathed FRLS copper conductor single core multi stranded flexible copper cable 1100 volts grade conforming to IS-694 using approved colour code as per IS code drawn through non metalic rigid PVC heavy duty conduit in concealed (min 20mm dia external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment including provision for fixing of Pressed steel sunken boxes of suitable size for fixing of modular switches/sockets /regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as continuous earth lead wire connected to common earth and earth dolly completed all as specified and directed by Engineer-in-Charge.
All as per Ser Item No 27.00 here-in-before but for 03 pin switch socket outlets 5A on independent board with the cable 1.50 Sqmm size complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item No 27.00 here-in-before but for 03 pin switch socket outlets 5A on same board with the cable 1.50 Sqmm size complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item No 26.00 here-in-before but but here Wiring with Copper conductor cables in PVC casing & caping complete all as specified and directed by Engineer-in-Charge.
All as per item NO.26 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size. complete all as spcified and directed by Engineer-in-Charge.
Switch piano flush type single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge.
Switch piano flush type single pole, two way 15 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge.
Socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Socket outlet 2 in 1, 3 Pin 5 & 15 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge.
Ceiling rose surface bakelite 2 to 3 terminals 65 x 50mm complete all as specified and directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:-
Servicing/overhauling the ceiling fan by throughly cleaning the bearing , shaft, stator,rotor, & applying the lubricant/grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete all as specified and directed.
All as per item no.38.01 above here in before, but re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
All as per item no.38.01 above here in before but applying two coats of synthetic enamel paint after preparation of surface complete all as specified and directed.
LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor able of suitable size from ceiling rose complete all as specified and directed.
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor able of suitable size from ceiling rose complete all as specified and directed.
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with hree core flexible copper conductor cable of suitable sizecomplete all as specified and directed.
Ceiling fans complete with blades, required down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in charge.
AC Three phase static energy meter of accuracy class 1.0 ,3 X 240 V ,50 Hz with Backlit LCD display of rating 10 - 60 A (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all as specified and directed by Engr-in charge
Air circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete with mountin arrangement complete all as specified and directed by Engr-in charge
High flow 400mm (16 inch) high speed oscillating plastic pedestal fan with aerodynamically balanced blade and three speed regulator, complete all as specified and directed.
LED flood light 70 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
LED Post top ideal to lit up, IP65 rated for garden lights 20 watts cat pt. Lpnt-20 CDL crompton all as specified and directed by Engr in charge.
LED outdoor type up-down light twilight with IP65 protection 5700k of size 10 Watt. Cat pt. LUPDN-10-CDL of crompton all as specified and directed by engr in charge.
LED step light for outdoor application IP65 rated of size 6 watt. Cat pt. LSL-6-CDL of crompton all as specified and directed by engr in charge.
Air curtain 70"X78" all as specified and directed by Engr in charge.
Air curtain sensor all as specified and directed by engr in charge.
Row indicator LED board (small size) for auditorium chair all as specified and directed by Engr in charge.
Single sided version ENTRY 3W signage SSD WBB display with right arrow with two Hrs battery backup all as specified and directed by Engr-in-charge
Single and double sided version EXIT 3W signage SSD WBB display with right arrow with two Hrs battery backup all as specified and directed by Engr-in-charge
Sheet metal enclosure VTPN MCCB DB 4 Way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 as per IEC 61439-3 suitable for flush mounting complete with 250 A copper bus bar for each phase with 2 neutral and 2 earth bus bars with cable ties for cable management for DB's when MCBs & MCCB 100 Amps (as incomer) to be used, fixed properly in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed by Engr In-Charge.
Sheet metal enclosure double door metallic for DB when MCBs to be used SPN 12 ways, 240 V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by Engr-In-Charge.
MCB Single Pole 6 to 32 Amp , rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning,complete all as specified and directed.
MCB Single Pole & Neutral 32 Amp , rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
MCCB 100 Amps, 3 Pole, 415 V, 16 KA thermal magnetic adjustable type with short circuit and overload protection complete all as directed by Engr In Charge.
Submain wiring using single core four run PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
Sub main wiring using single core two run PVC insulated, unseathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
Submain wiring using single core two run PVC insulated, unseathed stranded copper conductor cable of size 1.5 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1.5 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other ndicated situation for loop earthing etc. as required 4mm dia GI wire all as specified and directed by Engr in charge.
Bus bar chambers with MCCB factory febricated suitable for 3 Phase & neutral iron clad with 4 Nos 200 amp rated copper strips with two Nos Earthing connection bolt and one MCCB 125 Amps, 4 pole, 16KA with locking arrangement front door and back operated complete duly mounted on ground on suitable size of angle iron complete all as specified and directed by Engineer-in-charge.
Supply and install HI- wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engr-in-charge.
Supply and install vertical pack type units indoor/outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220V - 240V, 50 Hz of capacity 3.5 TR complete all as specified and directed by Engineer-in-charge.
M/S SINGH AND ASSOCIATES
commercial traders
kailu construction co
M/S SHRI RAM BUILDERS
JCC ENGINEERS PRIVATE LIMITED
M/S MULTI ENGINEERS
Bidder Name
kailu construction co
commercial traders
Ashoka Engineers
M/S SINGH AND ASSOCIATES
JCC ENGINEERS PRIVATE LIMITED
M/S MULTI ENGINEERS
M/S SHRI RAM BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .