| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹26.5 L+₹2.3 L (9.41%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹26.7 L+₹2.5 L (10.1%)Rejected-Finance H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹27.2 L+₹2.9 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹28.0 L+₹3.7 L (15.3%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
26 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
REPAIR TO DRAIN, PLINTH PROTECTION, SUNKEN PORTION AND NAHANI TRAPS AND HARD STANDING AND PATH IN MD ACCN AND OTM IN ZONE-II AREA UNDER GE MCEME SECUNDERABAD
2022_MES_541644_1
GE/MCEME/TOK/35 OF 22-23
Open Tender
Civil Works
Item Rate
180 days
GE MCEME SECUNDERABAD
Class D Category a(I)
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹70,000
Yes
25 Oct 2022
28 Jul 2022
29 Aug 2022
28 Jul 2022
26 Aug 2022
13 Aug 2022
Amount
Demoltion of old unserviceable cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engr-in-Charge.
M & L Rendering 15mm thick in CM (1:3) on sunken concrete floor surfaces mixed with integral water proofing compound finished even & smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. Note : WPC shall be measured & paid separately
M & L for PCC 1:4:8 type D2 using 40mm using graded stone aggregate as in foundations, filling in sunken portions and mass concrete complete all as specified and as directed by Engr-in-Charge.
M&L for 25mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in (sunken floors/ WC area ) complete all as specified and as directed by Engr-in-Charge.
M&L APP based polymeric membrane minimum weighing 3.60 kg/sqm and minimum 3 mm thick reinforced with polster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaced by forced applicaion complete all as specified including removal of existing treatment complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound complete all as specified and as directed by Engr-in-Charge.
S&F in repair PVC (SWR) 100/110 mm bore single socketed pipes in any length with rubber ring joints fixed to wall height upto 12 mtr with PVC clamps complete all as specified and directed.
S&F in repair PVC (SWR) 75 mm bore single socketed pipes in any length with rubber ring joints fixed to wall height upto 12 mtr with PVC clamps complete all as specified and directed.
S&F in repairs PVC(SWR) bend/shoe for 100/110 mm dia complete all as specified and as directed by Engr-in-Charge.
S&F in repairs PVC (SWR) 75 mm dia floor trap, plain with grating including jointing with solvent cement and connecting to existing lines complete all as specified and as directed
S&F in repairs PVC (SWR) gully grap 125/110 mm setting and jointing with solvent cement and preparation of trap hole complete and connecting necessary connections all as directed by Engr-in-Charge
Dismantling of floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 25 mm thick type B1 1:2:4 (20 mm graded agg ) as in sub base complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick screed bed or bedding layer of mortar CM 1:6 for laying of floor finished complete all as specified and as directed by Engr-in-Charge.
M&L for non skid ceramic coloured dark shade tiles 7 to 8 mm thick area of each tile exc 0.060 sqm but not exc .11sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for Glazed ceramic tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of internal dia 150mm
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of internal dia 200 mm complete all as specified and as directed by Engr-in-Charge.
M&L for 150 mm internal dia of reinforcd concrete pipes class NP-2 with one coller per length of pipe complete all as specified and as directed by Engr-in-Charge.
M&L for 200 mm internal dia of reinforcd concrete pipes class NP-2 with one coller per length of pipe complete all as specified and as directed by Engr-in-Charge.
M&L for Concrete bed to 150 mm bore dia drain pipes including packing under haunching against the sides of pipes with concrete after they are laid and tested; in set in CM 1:4:8 type D-2 complete all as specified and as directed by Engr-in-Charge.
M&L for Concrete bed to 200 mm bore dia drain pipes including packing under haunching against the sides of pipes with concrete after they are laid and tested; in set in CM 1:4:8 type D-2 complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5 m deep and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engr-in-Charge.
Removing of excavated materials exc 250 m but n.exc 500 m and deposited and where directed complete all as specified and as directed by Engr-in-Charge.
Pumping out sewage water /sludge from septic tanks/soak wells/ sumps /Man holes etc of any dia by means of mechanical operated equipments /trolley mounted browsers duly taking all precautionary measures and removing sludge/water out side and away from the MD land ( working in fowl condition) complete all as specified and directed
S & F in repairs, vitreous china squatting pan, 'orissa' pattern of size 580x440mm white, with integral foot rests including concrete bedding & inc. CI 'P' trap, 100mm,complete all as specified and as directed by Engr-in-Charge.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 200/225mm dia pipe complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed.
Demolition of reinforced cement concrete of any descritpion all as directed by Engineer-in-Charge
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs etc including necessary form work and set in CM 1:6, complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately
M&L for Mild steel TMT bars 6 to 8 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
M& L for rendering 15 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces finsished even and smooth without using extra cement including taking down cement plaster complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engr-in-Charge.
M&L for 75 mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) complete all as specified and as directed by Engr-in-Charge.
M&L for 50 mm sand filling under floors or in foundations including watering and consolidation spread, rolled and consolidated to gradient and camber required complete all as specified and as directed by Engr-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed by Engr-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes complete all as specified and as directed by Engr-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) for coping or chamfered on edges complete all as specified and as directed by Engr-in-Charge.
M & L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, complete all as specified and directed by Engineer-in-Charge.
Demolition of precast concrete block masonry, built in cement mortar incl all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of old brick work of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete Type C1 1:3:6 (20 mm graded aggt) solid block masonry exc 10 cm in width and set in CM 1:6 complete all as specified and as directed by Engr-in-Charge.
M&L for old size brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM1:6 complete all as specified and as directed by Engr-in-Charge.
M& L for rendering 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finsished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
S&F in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engr-in-Charge.
S&F in repair 15mm dia brass Stop valves screwed down, high pressure, screwed both ends for iron pipe or for unions etc complete all as specified and directed.
S&F in repair 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed .
S&F in repair 15mm bore Bib taps fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed .
S&F in repair Vitreous China Urinal, Half stall type, white with push type tap all as specified excluding flushing pipe and waste pipe complete all as specified and as directed by Engr-in-Charge.
S&F in repair vitreous china EWC white including flush pipe, seat cover etc, including connection to drain (or out going pipe) and to flushing pipe anti syphonage pipes etc complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified, complete all as specified and as directed by Engineer-in-Charge. (Make : Jaguar)
S&F in repair PVC waste pipe, 40mm dia for sink, complete all as specified and as directed by Engr-in-Charge.
S & F in rep Grating doom 100mm dia of PTMT (Minimum weight 25gms), etc complete all as specified and as per directed by Engineer-in-Charge.
Taking up or down, 15mm dia bore, GI tubing, medium grade, complete all as specified and as directed by Engineer-in-Charge.
Taking up or down, 20mm dia bore, GI tubing, medium grade, complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc .
S&F in 20mm dia for high density polythelyne pipes (CPVC) of pressure rating 06 kgf/cm2 fixed complete to wall or in floors etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair sensor operated urinal half stall,with complete set complete all as specified and as directed by Engr-in-Charge. make Parryware/hindware/cera or eqivalent
Cutting chases, pinning in, making good to facings of brick/stonewall where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed by Engr-in-Charge.
M/S DIVIJA BUILDERS
G SATISH REDDY AND CO
harshraj and co
NEWS CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
M/S M.N.Reddy
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .