Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC 849 1 BADDI SHITALPUR BADDI INDUSTRIAL AREA SOLAN 173205 | SOLAN | HIMACHAL PRADESH | 173205 | ₹20.4 L | L1 | Accepted-AOC Award of Contracts being L1 |
| 2 | L2₹25.9 L+₹5.5 L (26.9%)Rejected-Finance 36 RANJEET NAGAR SHAHBAD MARKANDA NH 1 KURUKSHETRA HARYANA 136135 | KURUKSHETRA | HARYANA | 136135 | ₹25.9 L+₹5.5 L (26.9%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹27.1 L+₹6.7 L (33.0%)Rejected-Finance 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹27.1 L+₹6.7 L (33.0%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹27.7 L+₹7.3 L (35.8%)Rejected-Finance B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | ₹27.7 L+₹7.3 L (35.8%) | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Documents not complete as enlistment contractor. |
| Sl No | Description | Qty | Unit | GEO MEDIA ENGINEERING and CONSULTANCY SERVICES PRIVATE LIMITED L3 | Rishi Markandeshwar Engineering Consultant L2 | GEO DESIGNS AND RESEARCH PVT LTD L4 | Shiva Testing and Research Laboratory Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | (A) MULTISTOREY STRUCTURE.
Conducting soil investigation test at site as per relevant specification of IS-2131, IS-6403, IS-1498 & IS-2720 and submit the report as per following including shifting of equipment from one place to another place at any distance :-
(A) Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instruction of the Eng-in-charge. Refusal defined as and when 'N' value is 100 or more for 30 cm or part penetration.
(a) Conducting standard penetration test (SPT) in the bore holes at 1.00 m intervals in depth or every change of strata which ever is earlier as per IS:2131-1981or Condcuting dynamic cone penetration test (DCPT) in the bore holes at 1.00 m intervals in depth or every change of strate which ever is earlier as per IS:10042-1981 (Applicable for gravel, boulder deposit type of soil)
(i) Depth of bore hole = 15 m (for multistorey str qty 05BHs (04 in each corner & 01 in centre) in one block bldg, raft/ Mat footings)) | 5 | 15RM | 52,500 ₹2,62,500 | 50,100 ₹2,50,500 | 57,000 ₹2,85,000 | 22,890 ₹1,14,450 Lowest |
| 1.01(b) Collecting distrubed and undsturbed soil sample from the locatiion of conducting SPT/DCPT at an interval of 1.00 m depth or at change of strata whichever occurs earlier. (c ) Analysis of liquification potential for earthquake as per Zone-II of IS 1893-2016 (part-I). (d) Ground Water Table & HFL : (i) Maximum and minimum levels of ground water in the area with source of information. (ii) Ground water table observed during the investigation. (iii) Recording the ground water table if observed upto exploration depth, as per IS:6395-1973. (e) Disturbed soil samples : Following lab test to be conducted on disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- (i) Sieve analysis & Grain size distribution by Sieve analysis & hydrometer test (ii) Atterberg's limit as per IS:2720 Part-5-1985 (iii) Natural moisture content (iv) Particle size analysis test (v) Bulk density/dry density. (f) Undisturbed soil samples : Following lab test to be conducted on Un disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- | |||||||
| 1.02(i) Natural moisture content (ii) Bulk density (iii) Specific gravity (iv) Free swell index and swelling properties of soil (v) Organic matter in soil if any (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C&Ø test) as per relvant IS (viii) Harmful salt (complete investigation as already ref). (B) Submission of Six copies of ink signed test reports. The report should include the following (i) Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation. (ii) A detailed site plan showing the approx location of each bore duly numbered as per log of borehole should be enclosed with every site's soil investigation report. Location of foundation of adjacent structure, espacially those that might be impacted by the proposed construction should be indicated with details in site plan. (iii) The SBC of the soil is required to be given as per Sch 'A' Notes in tender documents, calculation of bearing capacity will be governed generally as per IS:8009 Part-1-1976, IS:2720 Part-2-1980, IS:6403-1980, IS:1904-1986 & IS:1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report. | |||||||
| 1.03(iv) Plotting of a complied sub surface profile along the depth in plan directions. (v) Photographic record of geo-explorations as well as testing shall also form part of the report.(min 04 Photographs). (vi) Every page of the Soil Investigation Report should have the Name of the Job for which Soil Investigation is being carried out. In case of multiple sites of a single Job are being investigated name of each site shall be put on each page of report pertaining to the site alongwith the name of the Job. (vii) The AGE (I) shall intimate the approximate type of construction, utilization and dimensions of proposed bldgs to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc) (viii) In case of underground building basement construction, or if requirement of temporary/permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations. Soil investigation report should be signed by M. Tech (Geotech). | |||||||
| 1.04(ix) Depending on the soil conditins found at site , the consultant will recommend if any changes in the soil strata is required to strengthen the soil like use of soil stabilization technique or any other such methods. (x) All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the soil investigation. Report should be scrutinized by GE & CWE for correctness & endorsed. Note :- Transportation of equipment/mobilization/Dematerialization of equipment, etc forsoil investigation shall be deemed to be included in quoted rates. | |||||||
| 2.00 | (B) SINGLE STOREY STRUCTURE.
Conducting soil investigation test at site as per relevant specification of IS-2131, IS-6403, IS-1498 & IS-2720 and submit the report as per following including shifting of equipment from one place to another place at any distance :-
(A) Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instruction of the Eng-in-charge. Refusal defined as and when 'N' value is 100 or more for 30 cm or part penetration.
(a) Conducting standard penetration test (SPT) in the bore holes at 1.00 m intervals in depth or every change of strata which ever is earlier as per IS:2131-1981or Condcuting dynamic cone penetration test (DCPT) in the bore holes at 1.00 m intervals in depth or every change of strate which ever is earlier as per IS:10042-1981 (Applicable for gravel, boulder deposit type of soil).
(i) Depth of bore hole = 10m (for single storey str, isolated footings) | 70 | 10RM | 35,000 ₹24,50,000 | 33,400 ₹23,38,000 | 35,500 ₹24,85,000 | 27,500 ₹19,25,000 Lowest |
| 2.01(b) Collecting distrubed and undsturbed soil sample from the locatiion of conducting SPT/DCPT at an interval of 1.00 m depth or at change of strata whichever occurs earlier. (c ) Analysis of liquification potential for earthquake as per Zone-II of IS 1893-2016 (part-I). (d) Ground Water Table & HFL : (i) Maximum and minimum levels of ground water in the area with source of information. (ii) Ground water table observed during the investigation. (iii) Recording the ground water table if observed upto exploration depth, as per IS:6395-1973. (e) Disturbed soil samples : Following lab test to be conducted on disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- (i) Sieve analysis & Grain size distribution by Sieve analysis & hydrometer test (ii) Atterberg's limit as per IS:2720 Part-5-1985 (iii) Natural moisture content (iv) Particle size analysis test (v) Bulk density/dry density. (f) Undisturbed soil samples : Following lab test to be conducted on Un disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- | |||||||
| 2.02(i) Natural moisture content (ii) Bulk density (iii) Specific gravity (iv) Free swell index and swelling properties of soil (v) Organic matter in soil if any (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C&Ø test) as per relvant IS (viii) Harmful salt (complete investigation as already ref). (B) Submission of Six copies of ink signed test reports. The report should include the following (i) Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation. (ii) A detailed site plan showing the approx location of each bore duly numbered as per log of borehole should be enclosed with every site's soil investigation report. Location of foundation of adjacent structure, espacially those that might be impacted by the proposed construction should be indicated with details in site plan. (iii) The SBC of the soil is required to be given as per Sch 'A' Notes in tender documents, calculation of bearing capacity will be governed generally as per IS:8009 Part-1-1976, IS:2720 Part-2-1980, IS:6403-1980, IS:1904-1986 & IS:1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report. | |||||||
| 2.03(iv) Plotting of a complied sub surface profile along the depth in plan directions. (v) Photographic record of geo-explorations as well as testing shall also form part of the report.(min 04 Photographs). (vi) Every page of the Soil Investigation Report should have the Name of the Job for which Soil Investigation is being carried out. In case of multiple sites of a single Job are being investigated name of each site shall be put on each page of report pertaining to the site alongwith the name of the Job. (vii) The AGE (I) shall intimate the approximate type of construction, utilization and dimensions of proposed bldgs to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc) (viii) In case of underground building basement construction, or if requirement of temporary/permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations. Soil investigation report should be signed by M. Tech (Geotech). | |||||||
| 2.04(ix) Depending on the soil conditins found at site , the consultant will recommend if any changes in the soil strata is required to strengthen the soil like use of soil stabilization technique or any other such methods. (x) All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the soil investigation. Report should be scrutinized by GE & CWE for correctness & endorsed. Note :- Transportation of equipment/mobilization/Dematerialization of equipment, etc forsoil investigation shall be deemed to be included in quoted rates. | |||||||
Tender Value
₹32.6 L
EMD Value
₹65,180
Closing Date
19 Jun 2026, 6:00 pmClosed
CWE (AF) AGRA
HQ CWE (AF) Agra
PROVN OF WORKS SERVICES FOR SOIL INVESTIGATION AT AF STATION JABALPUR UNDER AGE (I) AF SONEGAON
2026_MES_768620_1
80026-02/E8
Open Tender
Civil Works
Item Rate
90 days
AGE (I) AF Sonegaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Sonegaon
₹65,180
Yes
6 Aug 2026
29 May 2026
26 Jun 2026
29 May 2026
19 Jun 2026
12 Jun 2026
29 May 2026 - 5 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (A) MULTISTOREY STRUCTURE.
Conducting soil investigation test at site as per relevant specification of IS-2131, IS-6403, IS-1498 & IS-2720 and submit the report as per following including shifting of equipment from one place to another place at any distance :-
(A) Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instruction of the Eng-in-charge. Refusal defined as and when 'N' value is 100 or more for 30 cm or part penetration.
(a) Conducting standard penetration test (SPT) in the bore holes at 1.00 m intervals in depth or every change of strata which ever is earlier as per IS:2131-1981or Condcuting dynamic cone penetration test (DCPT) in the bore holes at 1.00 m intervals in depth or every change of strate which ever is earlier as per IS:10042-1981 (Applicable for gravel, boulder deposit type of soil)
(i) Depth of bore hole = 15 m (for multistorey str qty 05BHs (04 in each corner & 01 in centre) in one block bldg, raft/ Mat footings)) | 5 | 15RM | - | - |
| 1.01 | (b) Collecting distrubed and undsturbed soil sample from the locatiion of conducting SPT/DCPT at an interval of 1.00 m depth or at change of strata whichever occurs earlier.
(c ) Analysis of liquification potential for earthquake as per Zone-II of IS 1893-2016 (part-I).
(d) Ground Water Table & HFL :
(i) Maximum and minimum levels of ground water in the area with source of information.
(ii) Ground water table observed during the investigation.
(iii) Recording the ground water table if observed upto exploration depth, as per IS:6395-1973.
(e) Disturbed soil samples : Following lab test to be conducted on disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:-
(i) Sieve analysis & Grain size distribution by Sieve analysis & hydrometer test (ii) Atterberg's limit as per IS:2720 Part-5-1985 (iii) Natural moisture content (iv) Particle size analysis test (v) Bulk density/dry density.
(f) Undisturbed soil samples : Following lab test to be conducted on Un disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- | - | - | - | - |
| 1.02 | (i) Natural moisture content (ii) Bulk density (iii) Specific gravity (iv) Free swell index and swelling properties of soil (v) Organic matter in soil if any (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C&Ø test) as per relvant IS (viii) Harmful salt (complete investigation as already ref).
(B) Submission of Six copies of ink signed test reports. The report should include the following
(i) Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation.
(ii) A detailed site plan showing the approx location of each bore duly numbered as per log of borehole should be enclosed with every site's soil investigation report. Location of foundation of adjacent structure, espacially those that might be impacted by the proposed construction should be indicated with details in site plan.
(iii) The SBC of the soil is required to be given as per Sch 'A' Notes in tender documents, calculation of bearing capacity will be governed generally as per IS:8009 Part-1-1976, IS:2720 Part-2-1980, IS:6403-1980, IS:1904-1986 & IS:1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report. | - | - | - | - |
| 1.03 | (iv) Plotting of a complied sub surface profile along the depth in plan directions.
(v) Photographic record of geo-explorations as well as testing shall also form part of the report.(min 04 Photographs).
(vi) Every page of the Soil Investigation Report should have the Name of the Job for which Soil Investigation is being carried out. In case of multiple sites of a single Job are being investigated name of each site shall be put on each page of report pertaining to the site alongwith the name of the Job.
(vii) The AGE (I) shall intimate the approximate type of construction, utilization and dimensions of proposed bldgs to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc)
(viii) In case of underground building basement construction, or if requirement of temporary/permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations.
Soil investigation report should be signed by M. Tech (Geotech). | - | - | - | - |
| 1.04 | (ix) Depending on the soil conditins found at site , the consultant will recommend if any changes in the soil strata is required to strengthen the soil like use of soil stabilization technique or any other such methods.
(x) All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the soil investigation. Report should be scrutinized by GE & CWE for correctness & endorsed.
Note :-
Transportation of equipment/mobilization/Dematerialization of equipment, etc forsoil investigation shall be deemed to be included in quoted rates. | - | - | - | - |
| 2 | (B) SINGLE STOREY STRUCTURE.
Conducting soil investigation test at site as per relevant specification of IS-2131, IS-6403, IS-1498 & IS-2720 and submit the report as per following including shifting of equipment from one place to another place at any distance :-
(A) Drilling of 150 mm diameter bore hole in all types of soils as per depth indicated below or refusal strata which ever is earlier as per instruction of the Eng-in-charge. Refusal defined as and when 'N' value is 100 or more for 30 cm or part penetration.
(a) Conducting standard penetration test (SPT) in the bore holes at 1.00 m intervals in depth or every change of strata which ever is earlier as per IS:2131-1981or Condcuting dynamic cone penetration test (DCPT) in the bore holes at 1.00 m intervals in depth or every change of strate which ever is earlier as per IS:10042-1981 (Applicable for gravel, boulder deposit type of soil).
(i) Depth of bore hole = 10m (for single storey str, isolated footings) | 70 | 10RM | - | - |
| 2.01 | (b) Collecting distrubed and undsturbed soil sample from the locatiion of conducting SPT/DCPT at an interval of 1.00 m depth or at change of strata whichever occurs earlier.
(c ) Analysis of liquification potential for earthquake as per Zone-II of IS 1893-2016 (part-I).
(d) Ground Water Table & HFL :
(i) Maximum and minimum levels of ground water in the area with source of information.
(ii) Ground water table observed during the investigation.
(iii) Recording the ground water table if observed upto exploration depth, as per IS:6395-1973.
(e) Disturbed soil samples : Following lab test to be conducted on disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:-
(i) Sieve analysis & Grain size distribution by Sieve analysis & hydrometer test (ii) Atterberg's limit as per IS:2720 Part-5-1985 (iii) Natural moisture content (iv) Particle size analysis test (v) Bulk density/dry density.
(f) Undisturbed soil samples : Following lab test to be conducted on Un disturbed soil samples as considered necessary according to relevant specification IS-2720 and detailed result to be given in tabular form:- | - | - | - | - |
| 2.02 | (i) Natural moisture content (ii) Bulk density (iii) Specific gravity (iv) Free swell index and swelling properties of soil (v) Organic matter in soil if any (vi) Consolidation test (compressed index value) (vii) Triaxial compression test and determination of shear parameters (C&Ø test) as per relvant IS (viii) Harmful salt (complete investigation as already ref).
(B) Submission of Six copies of ink signed test reports. The report should include the following
(i) Detailed description of field investigation, soil classification and general nature of soil strata, water table, interpretation of test results, grain size distribution curves, compressive index curves, site plan etc, stress-strain modulus (by stress-strain curves from triaxial tests), foundation analysis & recommendations with supporting calculations regarding foundation system, depth of foundation.
(ii) A detailed site plan showing the approx location of each bore duly numbered as per log of borehole should be enclosed with every site's soil investigation report. Location of foundation of adjacent structure, espacially those that might be impacted by the proposed construction should be indicated with details in site plan.
(iii) The SBC of the soil is required to be given as per Sch 'A' Notes in tender documents, calculation of bearing capacity will be governed generally as per IS:8009 Part-1-1976, IS:2720 Part-2-1980, IS:6403-1980, IS:1904-1986 & IS:1080-1985 and other relevant IS codes and detailed calculations duly showing the various soil parameters/ indices shall be given in the soil report. | - | - | - | - |
| 2.03 | (iv) Plotting of a complied sub surface profile along the depth in plan directions.
(v) Photographic record of geo-explorations as well as testing shall also form part of the report.(min 04 Photographs).
(vi) Every page of the Soil Investigation Report should have the Name of the Job for which Soil Investigation is being carried out. In case of multiple sites of a single Job are being investigated name of each site shall be put on each page of report pertaining to the site alongwith the name of the Job.
(vii) The AGE (I) shall intimate the approximate type of construction, utilization and dimensions of proposed bldgs to the consultant, who based on geotechnical investigation, should recommend type of foundation (viz isolated/combined footing, raft, pile etc)
(viii) In case of underground building basement construction, or if requirement of temporary/permanent deep excavation support measures during construction of building are envisaged necessary excavation support measures to be given by the consultant based on geotechnical investigations.
Soil investigation report should be signed by M. Tech (Geotech). | - | - | - | - |
| 2.04 | (ix) Depending on the soil conditins found at site , the consultant will recommend if any changes in the soil strata is required to strengthen the soil like use of soil stabilization technique or any other such methods.
(x) All pages of the Soil Investigation Report shall be serially numbered, stamped and signed by the Agency carrying out the soil investigation. Report should be scrutinized by GE & CWE for correctness & endorsed.
Note :-
Transportation of equipment/mobilization/Dematerialization of equipment, etc forsoil investigation shall be deemed to be included in quoted rates. | - | - | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tenderdocuments.pdf
Tender Documents • 0.67 MB
BOQ_860748.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .