| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 LAccepted-Finance | 1 | Accepted-Finance The bidder has fulfilled the prerequisite formalities and stands qualified | |
| 2 | 2₹1.9 L+₹11,610 (6.60%)Accepted-Finance | 2 | Accepted-Finance The bidder has fulfilled the prerequisite formalities and stands qualified | |
| 3 | 3₹2.1 L+₹33,800 (19.2%)Accepted-Finance | 3 | Accepted-Finance The bidder has fulfilled the prerequisite formalities and stands qualified |
Tender Value
₹2.0 L
EMD Value
₹4,076
Closing Date
29 Sept 2022, 4:00 pmClosed
Executive Engineer PHE Mech. Div. South Awantipora
Executive Engineer PHE Mech. Div. South Awantipora
Providing, Installation, Testing and Commissioning of 100 KVA HT Transformer at Water Supply Scheme Vessu Manigam
2022_PHE_189535_3
JSD/PHE/MDSA/ e-NIT No. 59
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
20 days
Vessu Manigam
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Yes
Executive Engineer PHE Mech. Div. South Awantipora
₹4,076
Yes
12 Oct 2022
22 Sept 2022
30 Sept 2022
22 Sept 2022
29 Sept 2022
22 Sept 2022
Amount
Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Rating: 100 KVA Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input =11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate.
Rayees Electric Engineering Works
S T ELECTRICAL ENG WORKS PEERNAR TRAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .