Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.2 Cr+₹16.0 L (5.19%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹3.2 Cr+₹16.0 L (5.19%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹3.6 Cr+₹55.8 L (18.1%)Rejected-Finance | ₹3.6 Cr+₹55.8 L (18.1%) | L3 | Rejected-Finance Not L1 |
| 4 | L4₹3.7 Cr+₹65.7 L (21.3%)Rejected-Finance | ₹3.7 Cr+₹65.7 L (21.3%) | L4 | Rejected-Finance Not L1 |
| 5 | L5₹3.9 Cr+₹81.4 L (26.4%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹3.9 Cr+₹81.4 L (26.4%) | L5 | Rejected-Finance Not L1 |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
21 Dec 2020, 6:00 pmClosed
CHIEF ENGINEER
H.Q. CHIEF ENGINEER JAIPUR ZONE POWER HOUSE ROAD JAIPUR
PROVN OF DEFICIENT E/M SERVICES IN JCOs/OR MD ACCN AT HISAR
2020_MES_364486_1
CEJZ/NIT/HSR-03 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
HISAR
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE HISAR
₹5.5 L
Yes
29 Jan 2021
28 Jul 2020
28 Dec 2020
28 Jul 2020
21 Dec 2020
16 Dec 2020
Amount
Supply, installing, testing and commissioning outdoor type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 250 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +7.5%,+5%, +2.5%, 0%, -2.5%, - 5.0%, -7.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree Celsius in oil and 45 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run. The transformer shall be confirming to IS-1180 (updated),Energy Efficiency level-III complete all as specified and directed and shall including comprise of the following :-
(i) Three Nos porcelain bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers. (ii) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out of 500 sq mm 3.5 core , LT 1100 volts grade PVC / XLPE insulated & sheathed, heavy duty, armoured cables including joint and jointing materials complete. (iii) Oil conservator with filter type drain valve and oil level gauge. (iv) De-hydrating breather with first fill of dehydrating agent (silica gel). (v) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs for complete transformer and as well as core and winding assembly, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four Nos plain solid cast steel detachable rollers. (vi) One No 100 mm dia, dial type thermometer, vapor pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (vii) Two earthing terminals on tank cover to facilitate fixing of 25 x 4 mm galvanized iron earth strip for earthing of body and one no. HV side neutral grounding earth strip. (viii) Rating plate and terminal marking plate. (ix) First filling of new and unused transformer oil, IS-335 marked (Make Savita / Power Link) filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (x) One filter valve on the upper side of tank. (xi) Arcing horns for HT side (01 No per phase) Note : (i) PCC platform for transformer, chain link fencing gate shall be measured & paid separately. (ii) Factory inspection of transformer shall be carried out by Rep of Accepting Officer, Contractor has to intimate the same well in advance, cost of same shall be deemed to be included in quoted unit rates.
Supply, installing, testing and commissioning outdoor type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 315 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +7.5%,+5%, +2.5%, 0%, -2.5%, - 5.0%, -7.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree Celsius in oil and 45 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run. The transformer shall be confirming to IS-1180 (updated),Energy Efficiency level-III complete all as specified and directed and shall including comprise of the following :-
(i) Three Nos porcelain bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers. (ii) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out of 500 sq mm 3.5 core , LT 1100 volts grade PVC / XLPE insulated & sheathed, heavy duty, armoured cables including joint and jointing materials complete. (iii) Oil conservator with filter type drain valve and oil level gauge. (iv) De-hydrating breather with first fill of dehydrating agent (silica gel). (v) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs for complete transformer and as well as core and winding assembly, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four Nos plain solid cast steel detachable rollers. (vi) One No 100 mm dia, dial type thermometer, vapor pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (vii) Two earthing terminals on tank cover to facilitate fixing of 25 x 4 mm galvanized iron earth strip for earthing of body and one no. HV side neutral grounding earth strip. (viii) Rating plate and terminal marking plate. (ix) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (x) First filling of new and unused transformer oil, IS-335 marked (Make Savita / Power Link) filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (xi) One filter valve on the upper side of tank. (xii) Arcing horns for HT side (01 No per phase) Note : (i) PCC platform for transformer, chain link fencing gate shall be measured & paid separately. (ii) Factory inspection of transformer shall be carried out by Rep of Accepting Officer, Contractor has to intimate the same well in advance, cost of same shall be deemed to be included in quoted unit rates.
Supply, laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade(Earthed) of size 120 sqmm 3 core confirming to IS-7098 Pt-II, cable laid in trenches /walls /ducts/ poles complete all as specified and directed.
Supply, laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade(Earthed) of size 95 sqmm 3 core confirming to IS-7098 Pt-II, cable laid in trenches /walls /ducts/ poles complete all as specified and directed.
M&L for brick work using old size fly ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
Material and labour for hardcore of gauge n exc 63 mm , deposited , spread and leveled in layers n exc 15 cm thick, watered and rammed to a true surface with broken stone or boulders complete all as specified and directed.
'M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, mass concrete and filling etc complete all as specified and directed.
Material & labour for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface finished fair & even without using extra cement complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate finished cement concrete surface even and smooth without using extra cement as in flooring complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface, complete all as specified and directed.
'M& L PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
S&F MS angle iron posts and struts in fencing including cutting top to shape as directed drilling holes welding and notching for wire etc and flat iron fillets for securing wire mesh including necessary drilling, bolting or riveting etc conforming to Fe-290 Gde E-165, complete all as specified and directed.
Supply only chain link MS galvanised fencing of any mesh size/dia of wire as approved by GE complete all as specified and directed.
Fixing only chain link MS galvanized fencing of any mesh size/dia of wire including line wire and fixing to any type of fencing post struts and straining bolts including provision of binding wire, complete all as specified and directed.
Supply and fixing 10 mm dia mild steel round bars(straight or cambered) bearing bars or similar items such as bars for tightening of chain link fencing complete all as specified and directed.
S&F mild steel screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut not exc 5cm long and dia of shank 5 to 10mm complete all as specified and directed.
S & F Rolled Mild Steel work as in barred iron doors or Gates of angle or other section confirming to Fe 410. Gde -E-250 ends of bars shouldered and/ or riveted, or forge into spikes, complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm width or girth not otherwise described including preparation of surfaces complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description n. exc 10cm in width or girth not otherwise described including preparation of surfaces complete all as specified and directed.
Supply, jointing & testing for cable jointing kit outdoor type cable end termination (heat shrink type) complete with jointing materials and accessories suitable for 11 KV under ground XLPE, HTcable size 70sqmm to 120 sqmm 3 core complete all as specified and directed.
Supply, errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long , 152 mm x 152 mm at top and 152 mm x 260 mm at bottom,class 9 complete all as specified & directed .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 500 sq mm 3.5 core laid in trenches /walls /floor complete all as specified & directed .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core laid in trenches /walls /floor complete all as specified & directed .
Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core including taking out the existing unserviceable LT cable from wall / floor / trench etc complete all as specified & directed .
M & L for switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type/ vertical type as reqd and MS galvanized steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia / 25 mm dia as required GI pipe medium grade for current rating upto 200 Amps 11000 volts ,12 insulators complete with locking arrangement ,MS clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
M & L for switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type/ vertical type as reqd and MS galvanized steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia / 25 mm dia as required GI pipe medium grade for current rating upto 400 Amps 11000 volts ,12 insulators complete with locking arrangement ,MS clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
Disconnecting the electric supply and opening the HT/LT electrical connections from the transformer of capacity upto 400 KVA alongwith LT panel and transporting to a new location at distance not more than 1 KM from the existing location and re-fixing the transformer and LT panel complete all as specified and directed by Engineer-in-charge
Material & labour for lightening arrestors expulsion type complete with all fittings, transmission class discharge capacity 65 Kilo Amps 11000 volts complete all as specified and directed.
M & L for earthing complete with using galvanized iron strip 25 x 4 mm as earthing lead with galvanized steel earth plate electrode size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip earth lead 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe medium grade 40 mm bore connected to main earth on pole or control board and GI pipe medium grade 20mm bore for watering funnel with wire mesh. RCC cover with frame, PCC chamber pit with PCC 1:3:6 type C-1, excavation and earth work all as shown in electrical plate No 3 of SSR Part-I, connected to earthing test point including testing on completion complete all as specified or indicated. Note : The unit rate quoted shall be deemed to be included the following :- (i) 40mm thick precast cover slab of RCC 1:2:4 type B1 using 20mm graded stone aggreegate with suitable MS handle, reinforcement in RCC cover shall be 8mm dia TMT bar @ 150mm C/C both ways. (ii) Cost of 7.5m GI pipe for protection of the earth strip including cost of 7.5m long GI earth strip from earth electrode. (iii) The concrete pit in PCC 1:3:6 type C1 using 20mm graded stone aggregate. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to pact thickness of 15cm on all sides.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5m depth but not exc 3.0m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in hard/dense soil complete all as specified and directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed.
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed.
M & L for Sand cushioning and covering with clean dry sand to underground electric cable in trenches complete all as specified and directed. Note :- Punned thickness shall be measured.
Taking out existing serviceable /unserviceable bricks over UG Cables, from trenches and stacking at site for re-use complete all as specified & directed.
Laying only old serviceable bricks over UG Cables retrieved from item srl No. 37 above.
Supply and laying un-reinforced pre cast concrete cable cover of class LV type 1 with peakflat size 250mm x 150mm x 40mm complete all as specified and directed.
Supplying and laying, un-reinforced pre cast concrete cable cover of class HVP type 1 with peak flat size 300 mm x 180 mm x 40 mm complete all as specified & directed.
Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.562 kwh per day for 45 C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 year on other spares parts including comprising following fittings:- (a) Glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16 A capacity (i) Drain Plug (j) Fusible plug fitted on the crown of water heater with operating temperature between 40 degree centigrade to 75 degree centigrade including fixing by grouting and fastener complete all as specified and directed.
M&L point wiring complete with 2.5 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through & including rigid PVC conduit with necessary conduit fittings/ accessories fixed concealed in walls/ceiling all as per ISI including sunk type pressed steel terminal boxes for mounting, fittings like switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet top covers concealed in walls etc including 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly for 3 pin 15 Amp Socket outlet point controlled by 01 No, 1 way switch on independent board complete all as specified & directed.
M & L for Socket out let flush type 3/6 pin suitable for 15 Amp plug top Multipurpose 230 V complete all as specified & directed.
M & L for Switch Piano flush type 15 amp single Pole one way 230 V complete all as specified & directed.
Supply & Fixing M.C.B. SP, 240 Volts, 6-32 Amps breaking capacity 10 KA (type B curve) complete all as specified & directed.
S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified & directed.
S&F in replacement sheet metal enclosure MCB DB 63Amp TPN 4 way with 200 Amps rated bus bar 240 Volt double door with isolated Neutral & shrouded bus bar IP protection 43 having door earthing complete all as specified and directed.
Supply and fixing MCB 63 Amp TPN Breaking capacity 16 KA complete all as specified and directed.
M & L in replacement for sub main wiring with 2 single core PVC insulated unsheathed cable 1100 V grade with FRLS PVC 6 sqmm copper cable multi stranded conductor drawn through and including ISI marked PVC conduit 25 mm dia complete ,concealed in wall / ceiling as per IS including FRLS PVC 6 sqmm copper cable PVC insulated and sheathed cable green colour as earth wire connected to earth complete all as specified and directed. Note:- Two runs of single core 6 sqmm cable, one run of earth wire 6 sqmm cable and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron medium grade 15 mm bore pipe and GI Pipe 20 mm bore medium grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-1 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as directed. Note : The unit rate quoted shall be deemed to be included the following :- (i) 40mm thick precast cover slab of RCC 1:2:4 type B1 using 20mm graded stone aggreegate with suitable MS handle, reinforcement in RCC cover shall be 8mm dia TMT bar @ 150mm C/C both ways. (ii) Cost of 7.5m GI pipe for protection of the earth wire including cost of 7.5m long GI earth wire from earth electrode. (iii) The concrete pit in PCC 1:3:6 type C1 using 20mm graded stone aggregate. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to pact thickness of 15cm on all sides.
M&L for cutting chases, pinning in existing work making good to facings as original where required and pointing in cement mortar 1.3 for concealed water tubing and making good. cutting exc 10 cm but not exc 20 cm girth in brick walls complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing or removal to store of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing or removal to store of 20 mm bore complete all as specified and directed.
M&L for GI tubing 15mm bore fixed to walls, cellings or laid in floors medium grade concealed including fittingcomplete all as specified and directed.
M&L for Gl tubing 20mm bore fixed to walls, celings or laid in floors medium grade including fitting complete all as specified and directed.
Dismanting floor, hearth or wall tiling including cement mortar bedding (but not backing), removing seviceble tiles to store and rubish off the primises complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick bedding layer in cement mortar 1.6 complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 300x450x7mm / 250x350x7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S&F in repair 15mm bore , bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, 15mm bore fixed to pipe complete all as specified and directed.
S&F in repair 15mm bore , stop valves/angle valve, fancy type.chromium plated, cast copper alloy screwed down high pressure fixed to pipe of 15mm bore complete all as specified and directed.
S&F CP brass wall mixer for mixing hot & cold water screwed down for iron pipe of size 15mm bore and fixed complete all as specified and directed.
S&F in repair single flow overhead shower with arm and wall flange fixed to 15mm dia Gl pipe complete al as specified. Make Cat Part No T9927A1 (parryware) or equivelent make as specified in apendix B.
S & F drop out fuse assembly single pole 11 KV, 25 Amps rating complete expulsion fuse element mounted on four / two pole structure complete all as specified an directed.
S & F MCB SPN 230 Volts, 32 Amp breaking capacity, 10 KA type ‘B’ curve complete all as specified an directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
M&L for Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
'S&F heavy duty PVC connection with PTMT nuts 15 mm dia and 450mm long suitable for hot & cold water connections complete all as specified and directed
Rough excavation not exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Earth filling under floors including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
R D Bansal
M/s Prem Associates
M/s Singh Engineering Corporation
Leo Air and Power Solution pvt Ltd.
Siya constructions
M K ENGINEERS CO.
VERMA BROTHERS
D K ELECTRICALS
Vijay Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .