Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹8.3 L+₹92,820 (12.7%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L2 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
31 Dec 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINT OF SOLAR WATER HEATING SYSTEM INCLUDING CONNECTED ITEMS AT VSN NAGPUR
2020_MES_400153_1
GE/NAG/20-21/8401/48
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹20,000
9 Mar 2021
3 Dec 2020
1 Jan 2021
3 Dec 2020
31 Dec 2020
17 Dec 2020
60 days
Amount
Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater & connected, testing commissioning and cleaning of service tank/storage tank etc. with replacing the following given in Item No 02 items including necessary electrical/water connection complete including transportation up and down complete all as specified and directed Note: The FPC panel will be measured & paid for seperately as supply only
Supply only New FPC Panels. size 2m x 1m
Taking down Damaged panel & Supply new , fixing , testing & commissioning of toughen U V glass (1Mtr x 2Mtr) and as per existing size of glass for collector complete all as specified and directed
Taking down U/S Hot water tank capacity 500 lpd & Supply and install , Testing and commissioning of solar Hot water tank 500 lpd capacity flate plate collector based on indirect transfer of heat tank duly insulated, all as specified and as directed.
Taking down U/S steel stand & and Material and Labour for fabrication steel stand for holding the panels / storage tank as required complete all as specified and directed
Taking down U/s & Supply and laying 20 mm bores of tubes 'medium grade' galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors complete all as specified and directed
Taking down U/s & Supply and laying 25 mm bores of tubes 'medium grade' galvanised with all fittings and fixed complete laid in trenches/wall and ceiling or laid in floors complete all as specified and directed
Taking down U/S pipe & Supply and fix K-Tech pipe pf 15 mm bore dia for hot water including all fittings complete all as specified and directed
M&L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as directed and specified ( SMQ Map area )
M&L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as directed and specified (OTM Area)
M&L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as directed and specified (MAP OMQ area)
M&L for descaling of collector using Fernox DS-3 cleaner chemical or OEM recommendation to clear the deposites of temporary hard ness inside of collector tubes/Flate plate collectors including braizing of leaking joint as required at site complete all as directed and specified (22 P&s)
Taking down U/S & Supply fixing , testing & commissioning of insulation for hot/cold water pipe 20/25 mm bore pipe of insulation on pipe complete all as speecified and directed
M&L for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 500 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and directed
M&L for descaling of heat exchanger inside of hot water tank after repair , testing & tank capacity 200 ltr existing tank including replacement of coldwater/hot water pipe complete all as specified and directed
Material and labour for gas welding of leaking joint in the flat panel collector complete all as specified and directed
Taking down U/S Supply and fix gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 25 mm , including taking down complete all as specified and directed
Taking down U/S Supply and fix gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm , including taking down complete all as specified and directed
Taking down U/S Supply and fix brass metal NRV ISI mark of size 20 dia complete with nuts,bolts,rubber gaskets etc including ,testing complete all as specified and directed
Taking down U/s and Supply and fix bib tap , cast copper alloy chromium coated , screwed down , screwed for iron pipe or for brass ferrule and fixed size 15 mm bore dia of pipe complete all as directed Make Jaquar/ Prayag
M & L for PCC 1:3:6 with 20 mm aggregate for making foundation for placing of rotational moulded polyethylene water storage tanks of capacity 500 Ltrs all as specified and as directed.
Taking out of defective evacuated tube from tube collector panel based on direct transforming heat of capacity 250 lpd and supply and install new evacuated tube in to the direct transfer heat solar panel complete all as specified and directed
Taking down U/S Supply and fix solar hot water hose pipe 1" (25.4) mm dia conforming to IS (444) type 2 (WP) suitable for water pressure 12kg/cm2 all as specified and as directed
M & L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in SSR part I para No. 4 to the earthing test point all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed.
M & L for earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 25x3 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part I connected to earthing test point and testing on completion. all as specified and as directed. Note:- the cast of excavation and earth work PCC pit and PCC cover with handle, funnel & watering pipe, wiremesh,charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing complete all as specified and as directed.
Testing of potable water sample collected from New Pump House or Gorewara pump house at vayusena Nagar Nagpur and testing report required from through reputed laboratory /Government lab as per BIS -10500:2012 for drinking water are required folowing test: (a) E-coil or thermo tolerant coliform bacteria
Testing of potable water sample collected from New Pump House and Gorewara pump house at vayusena Nagar Nagpur and testing report required from through reputed laboratory /Government lab as per BIS -10500:2012 for drinking water are required folowing test:Note > Testing shall be carried out monthly or as directed by Engr-in-charge Physical Test: unit (a) Temperature Centigrate (b) Turbidity NTU (C) Colour Hazen Chemical Test: Total Hardness as CaCo3 PH Scale Calcium as Ca Mg/L Magnesium as mg Mg/L Total Alkalinity as CaCo3 Mg/L Chloride as Cl Mg/L Total Dissolved Solids Mg/L Fluoride as F Mg/L Sulphate (so4) Mg/L
Supply and make liquid form and pore in chlorination plant in to the pump house i,e Gorewara and or New pump house , old pump house of Calcium based Granular Chlorination Chemical (60-70%) Chlorine Granuals in fine form of good quality Size 2-4 Mesh Appearance : White Granuals Effective Chlorine : 60-70% Make ALTOCH GP /ADITYA BIRLA Aquafit pirichlor by sree Royal seema , Purichlor all as directed in fine form of good quality. Note The cost of labour for making liquid and poring activitity of chemical shall be included in the quoted rate of items
Supply and pore bleaching powder under in under ground sump at both pump house ie. (Gorewara and New pump house) rate are deemed to included manpower for make liquid form for bleaching powder and pore to sump as regular or daily basis) at two time .
Material & Labour for Dismantling of Existing Damaged FPC Panel from solar water heater & refixing same after repaired and connected, testing commissioning and repairing of flanges, nut bolts and fixing support made otu of irn angles as pe existing size of panel and new refixing outside metalic frame around tough glass including necessary electrical/water connection complete including transportation up and down.
M/S JAINENDRA KUMAR JAIN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .